XP-Remote 2.11

Right choice for ultimate yield
LSIS strives to maximize customers' profit in gratitude of choosing us for your partner.
Human Machine Interface
XP-Remote
User’s Manual
XGT PANEL
Read this manual carefully before
installing, wiring, operating, servicing or
inspecting this equipment.
Keep this manual within easy reach for
quick reference.
http://eng.lsis.biz

2

Before using the product…
To use the product safely and effectively, please read this instruction manual thoroughly before use.
Please keep to the safety precaution, for it is to prevent accidents and potential danger from
occurring.
Safety precaution is classified into ‘Warning’ and ‘Caution’ and their meanings are as follows.
Violating the instruction may result in serious personal injury or death.
Violating the instruction may result in slight personal injury or product
damage.
The indicated illustrations on the product and in the manual have the following meanings.
Be cautious, for danger may be present.
Be cautious, for there is a possibility of an electric shock.
After reading the instruction manual, keep it handy for quick reference.
Warning
Caution

3
Design Precautions
Design Precautions
Installation Precautions
Install a safety circuit external to the HMI to protect the whole control system in case of
external power supply trouble.
Serious trouble may occur to the entire system due to erroneous output/operation of the HMI.
Warning
In/output signal or communication cable should be at least 100mm apart from
High-voltage/power wires.
Otherwise, it may cause erroneous output/operation.
Caution
Use the HMI in an environment that meets the general specification contained in this
manual or datasheet.
Otherwise, it could result in electric shock, fire, erroneous operation or deterioration.
In case of much vibration in the installed environment, be sure to insulate the HMI from
direct vibration.
Otherwise, it could result in electric shock, fire or erroneous operation.
Be sure not to let foreign substances such as conductive debris inside the product.
Otherwise, it could result in electric shock, fire or erroneous operation.
Caution

4

Wiring Precautions
Be sure to turn off the HMI and external power before wiring.
Otherwise, it may result in an electric shock or damage to the product.
Wire correctly by checking each of the product’s rated voltage and terminal layout.
Otherwise, it may result in fire, electric shock or erroneous operation.
Tighten terminal screws with specified torque when wiring.
If terminal screws are loose, it may result in short circuits, fire or erroneous operation.
Use the exclusive HMI 3-type grounding for the FG terminal.
If not grounded, it may result in erroneous operation.
Be sure not to let any foreign substances such as wiring debris inside the module.
Such debris may cause fire, damage or erroneous operation.
Caution
Warning

5
Startup and Maintenance Precautions
Disposal Precaution
Do not touch the terminals while power is on.
Otherwise, it may cause electric shock or erroneous operation.
Turn off the PLC and external power when cleaning or tightening the terminal.
Otherwise, it may cause electric shock or erroneous operation.
Do not charge, disassemble, heat, short circuit, solder, etc. the battery.
Mishandling the battery may cause overheating, crack, fire and may result in injury or fire.
Do not disassemble PCB from the product case or modify the product.
Otherwise, it may result in fire, electric shock or erroneous operation.
Use cellular phone or walky-talky at least 30cm away from the PLC.
Otherwise, it may result in erroneous operation.
When disposing of this product or battery, treat it as industrial waste.
Otherwise, it may cause poisonous pollution or explosion.
Warning
Caution
Caution

6

Revision History
Version Date Main Changes Revision Page
V 1.0 11 10 The initial edition issued-
※ The number of the User
s Manual is printed on the right side of the back cover of the Users Manual.
LSIS Co., Ltd 2010 All Rights Reserved.
7
Thank you for purchasing LSIS’s HMI.
Before using the product, please read this User’s Manual to understand the functions, performances
and installation and programming method of the product you have purchased and ensure this User’s
Manual is well distributed to the end user and the responsible person for maintenance .
The following User’s Manual is the one regarding to this product.
If needed, please, refer to the following contents of the User’s Manual and place an order.
Also, visit our homepage
http://www.lsis.biz/ and download the manual in PDF file.
List of Relevant Manuals

Manual Title Manual Contents Manual Number
XGT Panel
communication
User’s Manual
User’s Manual on XGT Panel communication describing
Circuit Diagram to connect XGT Panel products with
control devices such as PLC and inverter and their
communication setting
10310000758
XP-Builder
User’s Manual
User’s Manual on XP-Builder software describing screen
data, communication, environment setting, logging/recipe
data backup, simulator and printing function needed to
use XGT Panel products
10310000759
XGT Panel
User’s Manual
It describes dimensions, special features and system
configuration of XGT Panel series.
10310000757
XP-Manager
User’s Manual
XP-Manger is software that can support XGT Panel’s
various functions and perform data communication between
XGT panels via XP Link.
10310001110

 

8

- Table of Contents –

Chapter1 Starting ............................................................. 10 ~16

1.1 Special Features of the XP-Remote.............................................................. 10
1.2 System Requirements for Executing the XP-Remote ................................................ 11
1.3 Installation of the XP-Remote ................................................................ 12

Chapter 2 Introduction and Demonstration of the XP-Remote .................... 17 ~ 22

2.1 Introduction of the XP-Remote.................................................................. 17
2.1.1 What is the XP-Remote?................................................................... 17
2.1.2 Execution Condition of the XP-Remote .................................................... 17
2.2 Demonstration ................................................................................. 18
2.2.1 Execution of the XGT Panel Monitor ...................................................... 18
2.2.2 Monitoring with the XP-Remote............................................................ 18
2.2.3 Controlling the XGT Panel with the XP-Remote ............................................. 21

Chapter 3 The XP-Remote Configuration ......................................... 23 ~ 28

3.1 Screen Configuration .......................................................................... 23
3.2 Menu Configuration ............................................................................ 25
3.3 Toolbar Configuration ......................................................................... 27

Chapter 4 Project ........................................................... 29 ~ 37

4.1 Reconnect ..................................................................................... 29
4.1.1 Connect by Using the next Address........................................................ 29
4.1.2 Connect After Finding and Opening a Project .............................................. 31
4.1.3 Connect After Opening Recent Projects ................................................... 33
4.2 Close......................................................................................... 35
4.3 End........................................................................................... 37

Chapter 5 Online ............................................................. 38 ~ 48

5.1 Screen Sync Mode .............................................................................. 38
5.1.1 Convert Screen by the XGT Panel.......................................................... 38
5.1.2 Convert Screen on the XP-Remote.......................................................... 39
5.2 Screen Non-Sync Mode .......................................................................... 41
5.2.1 Convert Screen by the XGT Panel.......................................................... 41

9
5.2.2 Convert Screen on the XP-Remote.............................................................. 42
5.3 Obtain the Control Right ...................................................................... 44
5.4 Return the Control Right ...................................................................... 46
5.5 Obtain the Control Right From the XGT Panel .................................................... 47

Chapter 6 Screen ............................................................. 49 ~ 53

6.1 Convert to the XGT Panel’s Current Screen ..................................................... 49
6.2 Convert to the Starting Screen................................................................. 50
6.3 Convert to the Previous Screen................................................................. 51
6.4 Convert to the 1 minus Screen.................................................................. 51
6.5 Convert to the 1 plus Screen................................................................... 52
6.6 Screen Conversion Combo Box ................................................................... 53

Chapter 7 Tools .............................................................. 54 ~ 59

7.1 Adjust Screen Size ............................................................................ 54
7.2 Screen Capture ................................................................................ 55
7.3 Options....................................................................................... 56
7.3.1 Online .................................................................................. 56
7.3.2 Control ................................................................................. 58
7.3.1 General ................................................................................. 58

Chapter 8 Restriction ........................................................ 60 ~ 63

8.1 Restriction ................................................................................... 60
8.2 Difference in Movement Between XP-Remote and XGT Panel ......................................... 62

Annex 1 Problem Solving ...................................................... 64 ~ 66

Annex 1.1 Problem Types........................................................................... 64
Annex1.2 Communication Problems................................................................... 65
Annex1.3 Control Right Problems................................................................... 66

10

Chapter 1 Start
1.1 Special Features of the XP-Remote
XP-Manger is a tool to monitor and control the XGT Panel installed in the office or in the plant. The XGT
Panel can be monitored by several people at the same time.
(1) Remote monitoring of XGT Panel is available
(2) The XGT Panel can be controlled remotely in the same way as at the site.
(3) Fast monitoring and controlling is available even from a remote area.
(4) It consists of big icons to use its functions easily.
(5) It is easy to convert to a particular screen regardless of drawing contents.
(6) It can reduce uploading time when saving the project and re-starting monitoring.
LAN
11
(7) Available to monitor the XGT Panel and other screens.
(8) Multiple users can monitor one XGT Panel.
LAN
LAN

12

1.2 System Requirements for Executing the XP-Remote
(1) Personal Computer and Memory
A computer with memory of at least 512MB or higher in the CPU of Pentium 4 or higher
(2) Communication Port
Ethernet ports
(3) Hard Disc
Available area of at least 100MB or above
(4) Mouse
Mouse that can be connected with the computer
(5) Monitor
Resolution of 1024 X 768 or above
(6) Computer Operation System
Execution is available on the version of Window XP or above
13
1.3 Installation of the XP-Remote
[Installation Sequence]
(1) Execute installation files
(2) Select a language to be installed
(3) Prepare for installing the installation wizard as follows:
(4)
Starting the XP-Remote Installationis displayed as seen in the following screen. Press the
[Next] button to continue installation.

14

(5) After inputting the user information, press the Next button.
(6) Specify a folder location to install the XP-Remote. About 100MB installation space is needed for
the XP-Remote. Check if there is sufficient space in the folder subject to installation. If the

15
installation space is not sufficient, warning message will appear and proceeding to the next step
is impossible. Press the [Next] button after selecting a folder.
(7) Preparing for installation is completed. Press the Installation button to start installing.
(8) Installation progress is displayed.

16

(9) Press the End button to end installation normally.
(10) Execute the XP-Remote from the [Start] Menu or execute
Go To Directlygenerated on the 바탕
screen to start the task.

17
[Deleting Sequence]
(1) To remove the XP-Remote, select [Remove XP-Remote] from the [Start] Menu or use the Control
edition
s [Add/Delete Program] function.
(2) Select an Y
(3) Information on the installed programs is collected and those programs are deleted.

18

Chapter 2 Introduction and Demonstration of the XP-Remote
2.1 Introduction of the XP-Remote
2.1.1 What is the XP-Remote?
The user can remote monitor and control the XGT Panel by using the XP-Remote. The user can perform the
XGT Panel’s functions above with the office computer not with the site’s XGT Panel.
The user does not perform works under poor site conditions any more.
2.1.2 Execution Condition of the XP-Remote
The XP-Remote shall be satisfied the following conditions to ensure remote monitoring and controlling:
(a) XP-Builder 1.30 or above
(b) XGT Panel 1.30 or above
(c) Environment under which LAN communication is available
(d) Check the XGT Panel Setting [Settings]-[XP-Remote]-[XP-Remote]’s [Allow XP-Remote to connect]
options
LAN
19
2.2 Demonstration
The user can understand easily on overall methods to use the XP-Remote through the following demonstration
processes.
2.2.1Execution of the XGT Panel Monitor
[Sequence]
(a) Turn the XGT Panel on.
(b) Send drawings by using the XP-Builder (1.30 version or above)
(c) Check the XGT Panels button [Settings]-[XP-Remote]’s [Allow XP-Remote to connect] options.
(d) Press the XGT Panel button [Start] to start monitoring.
2.2.2 Monitoring with the XP-Remote
The XP-Remote shall be executed to monitor the XGT Panel from any remote computer.
[Sequence]
(a) Execute [XP-Remote 1.00] from the widows’ starting program
(b) Select XP-Remote Menu [Tools]-[Options]-[Online] tap.
(c) Select a network adopter with the same band with the XGT Panel’s IP band and close the dialog box
by pressing Confirm.

20

 

Note
(1) The same band with the XGT Panel’s IP band’ means that it is the same IP band if the XGT Panels IP
Address is
165.244.149.113 and the notebooks IP is 165.244.149.113

(d) Select XP-Remote Menu [Project]-[Reconnect] and input the XGT Panel’s IP Address.
(e) Press the [Connect] button to connect with the XGT Panel.

Note
(1) The following message will appear in case that communication with the XGT Panel is failed. Check
communication errors and attempt again to make a Reconnect.

21

(2) For detailed solution when communication fails, refer to Annex 1 Problem Solving.

(f) The XGT Panel’s data connected with the XP-Remote will be synchronized.
(g) The XP-Remote monitor will start.

22

2.2.3 Controlling the XGT Panel with the XP-Remote
For remote controlling with the XP-Remote, the following procedures are necessary. Basically, only
connecting with the XP-Remote does not allow remote controlling.
[Sequence]
(a) Press and hold the empty space of the XGT Panel screen about 2 seconds.
(b) Press the [Enable control by XP-Remote] button and allow the XP-Remote to control.

Note
(1) When displaying the Status Bar by pressing the XGT Panel’s empty space once again, this button is
displayed in [Disable control by XP-Remote].

(c) Press the XP-Remote Menu [Online]-[Obtain the Control Right] to obtain a control right.

Note
(1) If the control right is not obtained, the mouse cursor will have the following shape when it is moved on
the screen.
(2) If the control right is not obtained, the XP-Remote
s Status Bar will display the following icons:

(d) Press the mouse’s left button to control the XGT Panel.
Chapter 3 XP-Remote Configuration
23
3.1 Screen Configuration
The XP-Remote screen consists of the following components:
(1) Screen
[Window Description]

Item Description
Title Bar(a) Project name + XGT Panel Machine Type [XGT Panel’s IP Address] + XP-Remote is
displayed. It appears on the window’s working window.
Menu Bar(b) Basic menu for programs.

 

24

 

Tool Bar(c) Button to execute commands directly from the menu.
Screen Window(d) XGT Panel’s screen. In case of non-sync mode, different screen will be seen.
Status Bar(i) Description or movement of the currently selected file is displayed. Obtain the
Whether there is a control right or not and the entity who owns the control right
are displayed.

 

Note
(1) If a project is not saved, its project name is not displayed on the Title Bar.

(2) Status Bar
[Status Bar Description]

Item Description
Description(a) The selected menu is described and displayed.
Display(b) Possession status of the control right over the XP-Remote is displayed.
No control right
Possession of control right
Control Right
information(c)
If there is no control right, information on other node that owns the control right
is displayed.
If other XP-Remote owns the control right, the IP Address of the computer in which
the corresponding XP-Remote is executing is displayed.
If the XGT Panel own this control right, “XGT Panel’ is displayed.

3.2 Menu Configuration
The XP-Remote menu is described. For the menus with short-cut keys, their commands are implemented through
pressing short-cut keys only.
(1) Project
25

Command Description
Reconnect Close the opened project and connect with the XGT Panel again. Open a
saved project and connect with the XGT Panel.
Close Close the opened project.
Save Save the opened project.
Save as Different Name Save the opened project under a different name
Recent File List of the currently opened files is displayed
End The XP-Remote ends.

(2) Online

Command Description
Screen Sync Mode Always show the same screen with the XGT Panel.
Screen Non-Sync Mode Show different screen from the XGT Panel.
Obtain the Control Right Press the mouse’s left button and the XGT Panel’s switch to control.
Return the Control Right The control right is returned to the XGT Panel. Controlling is not
available any more.

(3) Screen

26

 

Command Description
Convert to the XGT Panel’s Current
Screen
In case of the screen in non-sync mode, convert to the XGT
Panel’s current screen.
Convert to the Starting Screen Convert to the starting project in the drawing
Convert to the Previous Screen If converting to screen has been performed before, convert to
the previous screen
Convert to the 1 minus Screen Convert to the screen that subtracts 1 from the current one
Convert to the 1 plus Screen Convert to the screen that adds 1 to the current one.

(4) Tools

Command Description
Adjust Screen Size If the XP-Remote’s screen size is already adjusted, adjust to its
original size and align it to the screen.
Screen Capture The displayed screen on the XP-Remote is captured and saved in a bitmap
file.
Options The XP-Remote’s environment settings can be changed.

(5) Help

Command Description
Help The XP-Remote Help File is executed.

27

XP-Remote information The XP-Remote’s version information and license are
displayed .

3.3 Toolbar Configuration

Command Image Description
Reconnect Close the opened project and connect with the XGT Panel again.
Open a saved project and connect with the XGT Panel.
Save Save the opened project.
Screen Sync Mode Always show the same screen with the XGT Panel.
Screen Non-Sync Mode Show different screen from the XGT Panel.
Obtain the Control
Right
Press the mouse’s left button and the XGT Panel’s switch to
control.
Return the Control
Right
The control right is returned to the XGT Panel. Controlling is
not available any more.
Convert to the
Starting Screen
Convert to the starting project in the drawing
Convert to the
Previous Screen
If converting to screen has been performed before, convert to
the previous screen
Convert to the 1
minus Screen
Convert to the screen that subtracts 1 from the current one
Convert to the 1
plus Screen
Convert to the screen that adds 1 to the current one.
Screen Capture The displayed screen on the XP-Remote is captured and saved in
a bitmap file.

(d)

28

 

Screen Combo Box The current screen number is displayed.
If the Combo Box is unfolded, the screen number list can be
seen.

Chapter 4 Project
4.1 Reconnect
The XP-Remote can move only when it is connected with the XGT Panel through Online. The following three
29
methods can be used for reconnection.
4.1.1 Connect to the Next IP Address
Connecting is available after directly inputting the XGT Panel’s IP Address. The XGT Panel’s IP Address to
be connected shall be known in advance.
Monitoring is possible by connecting with the XGT Panel with the inputted IP Address and synchronizing the
project with it.
[Sequence]
(1) Select Menu [Project]-[Reconnect]
(2) Select Option [Connect to Next IP Address]
(3) Input IP Address.
(4)
or press the [Search] button to search and select the XGT Panel on the network.
(a) (c)
d)
(b)

30

(5) Press the [Connect] button to connect with the XGT Panel.
[Dialog Box Description]

Item Description
Connect to Next IP
Address(a)
The inputted IP Address’s XGT Panel is connected. Input an accurate IP
Address.
Obtain the Control
Right(b) after
Connecting with the XGT
Panel
Obtaining the control right is attempted automatically after connecting with the
XGT Panel. If the XGT Panel does not allow the control right, that attempt might
be turned into failure.
Read NVRAM data when
starting
communication(c)
에 The saved information on logging, alarm and recipe in the XGT Panel is
converted into the latest one and synchronized with the XP-Remote.
Search(d) XGT Panels are searched and selected on the network.
Connect (e) A project is generated after connecting with the XGT Panel
XGT Panel List(f) A list of XGT Panels that respond on the network is displayed. IP Address and
status information are displayed.
Confirm(g) The selected XGT Panel’s IP Address is returned.

 

Note
(1) In case that communication with the XGT Panel is failed, the following message will appear. Check
communication errors and attempt reconnection.

(e)
(f)

31

(2) For detailed solutions in case of communication failure, refer to Annex 1 Problem Solving

4.1.2 Connect After Finding and Opening a Project
[Sequence]
(1) Select Menu [Project]-[Reconnect].
(2) Select Option [Connect After Finding and Opening a Project].
(3) Press the [Connect] button.
(4) A dialog box to find a file appears. After finding a file, press the [Open] button.
(a)
(b)

32

(5) After opening the selected file by pressing the [Open] button, connect with the XGT Panel with the
saved IP Address.
[Dialog Box Description]

Item Description
Connect After Finding
and Opening a
Project(a)
Find and open a XP-Remote file among the saved files. Find a XRT file. XRT files
are XP-Remote project files.
Connect (b) Call a dialog box to find a file.
File List(c) A XRT file list is seen in the selected folder. If there is no XRT file, no list
is displayed.
Open(d) A selected XRT file is opened. After opening, the XGT Panel is connected with
the saved IP Address.
Note
(1) When communication with the XGT Panel is failed, the following message will appear. Check communication
errors and attempt reconnection.

(c)
(d)

33

(2) For detailed solutions in case of communication failure, refer to Annex 1 Problem Solving
(3) Basically, the file list shows only XRT files and folders. When changing the file type into Alltype, all
of files in the folder can be seen.

4.1.2 Connect After Opening Recent Projects
[Sequence]
(1) Select Menu [Project]-[Reconnect]
(2) Select option [Connect After Opening Recent Projects]
(3) Select a file from the list.
(4) Press the [Connect] button and connect with the XGT Panel.
[Dialog Box Description]

Item Description
Connect After Opening Recent After opening a selected file among the list that has been opened before

(a)
(b)
(c)
(d)

34

 

Projects (a) on the XP-Remote, connect it with the XGT Panel.
Project List(b) Display the Project List that has been opened before.
View All Paths(c) Show the entire path on which files are located.
Connect (d) After opening a selected file, connect it with the XGT Panel with the
saved IP Address.

 

Note
(1) In case that communication with the XGT Panel is failed, the following message will appear. Check
communication errors and attempt reconnection.
(2)For detailed solutions in case of communication failure, refer to
Annex 1 Problem Solving.
(3) If there is no selected project, the following error message will appear.
(4) The same list with the Menu [Project]
s latest Project List is displayed.

35
4.2 Close
Close the opened project.
[Sequence]
(1) Select Menu [Project]-[Close]

36

(1) In case that any opened project is closed without being saved or the connected XGT Panel’s drawing is
revised, it checks whether to save changes or not.

37
4.3 End
Close the opened project and end the XP-Remote.
[Sequence]
(1) Select Menu [Project]-[End].
(1) In case that any opened project is closed without being saved or the connected XGT Panel’s drawing is
revised, it checks whether to save changes or not.
(2) The XP-Remote will be ended.

38

Chapter 5 Online
5.1 Screen Sync Mode
After the XP-Remote is connected with the XGT Panel, always the same screen is displayed. The same screen is
displayed with the basic screen, Global Window1 and Global Window2.
In case that a screen is converted from the XGT Panel, the XP-Remote also converts the screen.
In case that a screen is converted from the XGT Panel after the control right is obtained, the XP-Remote also
converts the screen.
[Sequence]
(1) Select Menu [Online]-[Screen Sync Mode].
(2) The same screen with the XGT Panel is displayed.

Note
(1) If the current mode is the Screen Sync Mode, Menu [Screen Sync Mode] has been already checked.
(2) In case that it is in the Screen Non-Sync Mode and a different screen from the XGT Panel is displayed, it
converts into the same screen with the XGT Panel if the Screen Sync Mode is selected.
(3) The Screen Sync Mode can be implemented regardless of owning the control right.
(4) Any window generated upon pressing any window switch or the pressure keypad screen is not synchronized.
(5) Device values are always synchronized regardless of the Screen Sync Mode.

5.1.1 Convert Screen by the XGT Panel
When a screen is converted by the XGT Panel, a screen is converted also on the XP-Remote.
39
5.1.2 Convert Screen on the XP-Remote
When the XP-Remote owns the control right, a screen is converted also on the XGT Panel as a screen is converted
on the XP-Remote.
LAN
Convert screen by the channel
number 2.
Screen sync
Screen sync
complementation

40

LAN
Screen sync
Screen sync
complementation
Convert screen by the
channel number 2.

41
5.2 Screen Non-Sync Mode
Different screen from the XGT Panel can be monitored on the XP-Remote. The basic screen, Global Window1 and
Global Window2 can be seen differently.
Even a screen is converted on the XGT Panel, the current screen is continuously displayed on the XP-Remote.
In contrary, in case that a screen is converted on the XP-Remote, the XGT Panel continuously displays the
current screen.
[Sequence]
(1) Select Menu [Online]-[Screen Sync Mode].

Note
(1) If the current screen is the Screen Non-Sync Mode, Menu [Screen Non-Sync Mode] has been already checked.
(2) The Screen Sync Mode can be implemented regardless of owning the control right.
(3) Device values are always synchronized regardless of the Screen Sync Mode.
(4) In case that the XP-Remote does not have any control right, a screen can be converted by using the screen
Conversion menu. For details, refer to
“”Chapter 6 Screenin the Users Manual.

5.2.1 Convert Screen by the XGT Panel
Even though a screen is converted by the XGT Panel, any screen is not converted on the XP-Remote.

42

5.2.2 Convert Screen on the XP-Remote
Even though a screen is converted on the XGT Remote, any screen is not converted on the XP-Panel.
LAN
Convert screen by the channel
number 2.

43
LAN
Convert screen by the
channel number 2.

44

5.3 Obtain the Control Right
At the first implementation, the XP-Remote does not own the control right. Therefore, the XGT Panel’s
switches cannot be controller. Only after a control right is obtained from the XGT Panel, they can be
controlled.
[Sequence]
(1) Press non-screen of the XGT Panel’s screen about 2 seconds.
(2) Press the [Enable control by XP-Remote] button in the dialog box at the bottom of the screen.

45

Note
(1) If Option [Allow XP-Remote to connect]is not checked in the XGT Panels Menu [Settings]-[XP-Remote] Setting
dialog box, the [Enable control by XP-Remote] button cannot be seen.
(2) The [Enable control by XP-Remote] button will be changed into the [Disable control by XP-Remote]one.

(3) Select XP-Remote Menu [Online]-[Obtain the Control Right].
(4) When the XP-Remote obtains the control right, the XGT Panel can be controlled by pressing switches.

Note
(1) If the XP-Remote obtains the control right, [Online]-[Obtain the Control Right] Menu will be inactive.

 

46

 

(2) The XGT Panels [Enable control by XP-Remote] button is changed into the [Disable control by XP-Remote].
If the XP-Remote obtains the control right, 에 Control Right icon is displayed on the Status Bar

5.4 Return the Control Right
In case that controlling is not needed any more on the XP-Remote or other XP-Remote needs the control right,
the control right shall be returned to the XGT Panel. After the control right is returned, switches cannot be
controlled from XP-Remote.
[Sequence]
(1) Select XP-Remote Menu [Online]-[Return the Control Right]
(2) The control
right is returned to the XGT Panel.

Note
(1) If the XP-Remote returns the control right, [Online]-[Return the Control Right] Menu will be inactive.

47

(2) If the XP-Remote returns the control right, the Status Bar will show No Control Right icon.

5.5 Obtain the Control Right From the XGT Panel
When the XGT Panel does not have the control right and it is urgently needed for the XGT Panel to control,
the XP-Remote’s control right can be forcefully taken. Since then, the XP-Remote loses the control right.
[Sequence]
(1) Press non-screen of the XGT Panel’s screen about 2 seconds.
(2) Press the [Disable control by XP-Remote] button in the dialog box at the bottom of the screen.

48

49
Chapter 6 Screen
Since the XP-Remote provides the Screen Conversion Tool Bar, screen conversion movement in a drawing or
converting to other screen is possible.
The screen is convertible under the following conditions:

XP-Remote Control Right
Possession
Screen Mode Available to Convert Screen
No Control Right Screen Non-Sync Mode Available
No Control Right Screen Sync Mode Not available
Control Right Screen Non-Sync Mode Available
Control Right Screen Sync Mode Available

If the XP-Remote has the control right and it is in the sync mode, the XGT Panel screen is also convertible on the
XT Panel when the screen is converted.
6.1 Convert to the XGT Panels Current Screen
If the XP-Remote is in the Screen Non-Sync Mode, it is an available function when a different screen is
displayed from the XGT Panel’s screen. It converts to the screen that the XGT Panel is currently displaying.
[Sequence]
(1) Select XP-Remote Menu [Screen]-[Convert to the XGT Panel’s Current Screen]
(2) It converts to the same screen with the XGT Panel
s current screen.

Note
(1) If the screen displays the same screen with the XGT Panel, the screen wont be converted even [Convert to
the XGT Panel’s Current Screen] Menu is selected.

 

50

6.2Convert to the Starting Screen
A designated screen in a drawing file of the XGT Panel is converted to the starting screen

Note
(1) Starting screen: The basic screen in bold font in the XP-Builder project window is the starting screen.
The starting screen is No. 1 screen in the following figure.

[Sequence]
(1) Select XP-Remote Menu [Screen]-[Convert to the Starting Screen].
(2) The starting screen is converted.

Note
(2) If the current screen is the starting screen, the screen wont be converted even [Convert to the Starting
Screen] Menu is selected.

51
6.3 Convert to the Previous Screen
This function is available if the XP-Remote has converted screens before. It converts to the previous screen.

Note
(1) Example of Converting to the Previous Screen
a. The current screen is NO. 10.
b. Convert to NO. 5 screen
c. Select the [Convert to Previous Screen] Menu
d. Convert to NO.10 screen

[Sequence]
(1) Select XP-Remote Menu [Screen]-[Convert to the Previous Screen].
(2) Converting to the previous screen is performed.

Note
(1) If the connected XGT Panel upon the start of the XP-Remote has converted screens before, it is possible to
convert to the previous screen

6.4 Convert to the 1 minus Screen
The current screen is converted to the screen that subtracts 1 from the current one.
[Sequence]
(1) Select XP-Remote Menu [Screen]-[Convert to the 1 minus Screen].

52

(2) Convert to the screen that subtracts 1 from the current one.

Note
(1) No. 0 screen is not converted.
(2) If the screen that subtracts 1 from the current one does not have any drawing, the screen is not
converted.

6.5 Convert to the 1 plus Screen
The current screen is converted to the screen that adds 1 to the current one.
[Sequence]
(1) Select XP-Remote Menu [Screen]-[Convert to the 1 plus Screen].
(2) Convert to the screen that adds 1 to the current one.

Note
(3) No. 0 screen is not converted.
(1) If the screen that adds 1 to the current one does not have any drawing, the screen is not converted.

53
6.6 Screen Conversion Combo Box
Screen Conversion Combo Box exists on the XP-Remote Tool Bar. Immediate converting to a particular screen number
is possible.
[Sequence]
(1) Select an arrow of screen number combo box to unfold the combo.
(2) A screen number list is displayed in the drawing.
(3) Select a screen number you want to move from the list.
(4) Convert to the selected screen.

Note
(1) Input a number directly in the combo box and press the Enter button to make the applicable screen
converted.
(2) If the inputted screen number does not exist in the drawing, converting is not performed.
screen number
NGis displayed as follows:

 

54

Chapter 7 Tools
7.1 Adjust Screen Size
Adjust the XP-Remote screen’s size to the XGT Panel’s screen size.
[Sequence]
(1) Select the XP-Remote Menu [Tools]-[Adjust Screen Size].
(2) Adjust the screen size to the XGT Panel screen size.

55
7.2 Screen Capture
A screen displayed on the XP-Remote is saved in a bitmap file.
[Sequence]
(1) Select XP-Remote Menu [Tools]-[Adjust Screen Size]

56

(2) A dialog box of saving as other name appears.
(3) Input a file name and press the Save button to save the file.
7.3 Options
7.3.1 Online
Settings related to online can be changed.
[Sequence]
(1) Select XP-Remote Menu [Tools]-[Options]-[Online] tap.
57
(2) Revise items and press the Confirm button.
[Dialog Box Description]

Item Description
Confirm(a) Save the changed contents and close the dialog box
Cancel(b) Close the dialog box without saving the changes
Apply(c) Apply the changes.
Time Out(d) Waiting time for response during the communication with the XGT Panel (1second ~
10seconds)
Communication
Interval(e)
Interval to collect device values on the screen (0.1second ~ 1.0 second)
1:1 Connect when
Connecting with the XGT
Panel (f)
If the selected adopter’s IP band is different from that of the XGT Panel, add
a virtual IP Address to the computer and attempt communication. But, on Windows
Vista and Windows 7, it is not supported.
Select a Network
Adopter for
communication(g)
Select a network adopter mounted on the computer. Data are sent or received via
the selected network adopter to the XGT Panel.

 

Note
(1) Select a network adopter whose IP band adopter is the same with that of the XGT Panel to reduce
communication error.

(g)
(f)
(e)
(d)
(a) (b) (c)

58

7.3.2 Control
Settings regarding to control can be changed.
[Sequence]
(1) Select XP-Remote Menu [Tools]-[Options]-[Control] tap.
(2) Revise items and press the Confirm button.
[Dialog Box Description]

Item Description
Obtain the Control
Right After connecting
with the XGT Panel (a)
After connecting with the XGT Panel, automatically attempt to obtain the control
right. For details on the control right, refer to “Chapter 5 Online” of the
User’s Manual.
Read NVRAM data when
Starting Communication
(b)
After connecting with the XGT Panel, read the XGT Panel’s NVRAM data and
synchronize alarm, logging and recipe information. If a drawing contains arm,
logging and recipe information, make sure to check options and synchronize it.
Implement Screen Script
In the Screen Non-Sync
Mode (c)
On the XP-Remote, screen script is not implemented. When this option is
selected, screen script will be implemented upon converting to the screen
synchronized with Screen Script.
Note
(1) PLC Control might be malfunctioning when any different screen script from that of the XGT Panel and that
of the XP-Remote is implemented in non-sync mode. That is why Screen Script is not used.

7.3.3 General
The XP-Remote’s general settings can be changed
[Sequence]
(a)
(b) (

59
(1) Select XP-Remote Menu [Tools]-[Options]-[General] tap.
(2) Modify items and press the Confirm button.
[Dialog Box Description]

Item Description
Path to Save Default Project
(a)
Specify a path to save a project for the first time.
Number of Displayed Recent
Projects(b)
Specify the number of displayed recent project list.
Display Dialog Box of
Reconnection When
Starting(c)
Set up whether to display a dialog box of reconnection when the XP-Remote
starts.
Adjust Screen Size After
Opening Project(d)
After the XP-Remote is connected with the XGT Panel, screen size is
automatically adjusted.

 

(a)
(b)
(c)
(d)

(a)
(b)
(c)
(d)

60

Chapter 8 Restriction
8.1 Restriction
The following functions are not available on the XP-Remote even though they are available on XGT Panel while
using the XP-Remote:

function Description
Global Script Global script in the drawing does not move.
Screen Script Screen script in the drawing does not move. But, it moves if [Options]-
[Control]의 [Implement Screen Script in the Screen Non-Sync Mode] option is
selected.
Script Function The following Script Functions do not move.
- Buzzer
- Backlight On
- SetBuzzerEnable
- ShowStatusbar
- HMIExit
- SetTime
- WriteToIO
- ReadFromIO
- PrintAlarm
- PrintScreen
Special Switch The following Special Switches do not move.
-
[History Alarm]-[Print Data]
- [Print Screen]
- [View History Alarm List]-[Delete the Selected Data]
- [View History Alarm List]-[Delete the Generation Times of All History
Alarms]
- [View History Alarm List]-[Delete the Generation Times of Selected
History Alarms]
- [View History Alarm List]-[Delete All Recovered Data]
- [View History Alarm List]-[Delete the Current Page Data]
- [Recipe]-[Search and Transmit Basic Recipes]-[Send NVRAM -> PLC]
- [Recipe]-[Search and Transmit Basic Recipes]-[Send PLC->NVRAM]
- [Recipe]-[Search and Transmit Basic Recipes]-[Send NVRAM ->
Internal Device]
- [Recipe]-[Search and Transmit Basic Recipes]-[Send Internal Device -
>NVRAM]
- [Recipe]-[Search and Transmit Basic Recipes]-[Send Internal Device -
> PLC]
- [Recipe]-[Search and Transmit Basic Recipes]-[Send IPLC -> Internal
Device]
- [Recipe]-[Search and Transmit File Recipes]-[Send Control기 -> XP]
- [Recipe]-[Search and Transmit File Recipes]-[Send XP -> Control기]
- [Memo Pad]-[Save]
- [Memo Pad]-[Delete Memo]
- [Memo Pad]-[Delete All Saved Memos]
- [Running Completed]

61

- [Execute External Program]
- [Program Monitoring]
Object The following objects are not displayed on the screen.
- Motion image player

 

62

8.2 Difference in Movement Between XP-Remote and XGT Panel
The following functions may move differently depending on the condition of using the XP-Remote:
In general, VNC is operated in such a manner as to share a mouse event / touch. But XP-Remote takes the approach that
shares the values of the XGT Panel and the device. Because of this, the screen does not remain the same, there are limitations
as follows.

function Description
PLC Device Always show the same values
INTERNAL Device HW, HX and HK device always show the same values.
The following HS devices always show the same values.
Bit Device

Address Description
HS0000.3 XGT Panel’s back light status
HS0070.0 XGT Panel’s N:1 master status
HS0051.0 ~ HS0051.2 XGT Panel’s outsourcing memory mouting
HS0100.0 XGT Panel’s VNC server movement status
HS0100.1 XGT Panel’s Web server movement status
HS0501.0 XGT Panel’s N:1 Master Holder Status
HS0503.0 XGT Panel’s VNC Interlock status
HS0504.0 XGT Panel’s allowing XP-Remote
Connection
HS0950.0 ~ HS0951.7 XGT Panel’s system alarm status
HS0952.0 ~ HS0953.F XGT Panel’s communication driver error

Word Device

Address Description
HS0001 ~ HS0002 XGT Panel’s version
HS0027 ~ HS0064 XGT Panel’s external memory size and
consumption amount
HS0071 ~ HS0073 XGT Panel’s N:1 communication information
HS0076 ~ HS0077 XGT Panel’s XP-Remote communication
information
HS0952 XGT Panel’s PLC communication timeout
HS0990 ~ HS1005 XGT Panel’s PLC communication status
information
Local Window Window, which appears upon the window switch, is not displayed on the XP
Remote even though it is displayed on the XGT Panel.
Ex) Input Tenky입력 텐키 Window
Convert Language If language conversion is not caused by devices, different languages may be
displayed on the XGT Panel and the XP-Remote.
Display the Current
Screen
If the XP-Remote is in the Screen Non-Sync Mode, different screens may be
displayed on the XGT Panel and the XP-Remote.
Global Window1, 2 If the XP-Remote is in the Screen Non-Sync Mode, different Global Windows may
be displayed.

63

Clock Object 에서 Clock Object on the XP-Remote displays computer clock.
Memo Pad Memo pad contents on the XP-Panel are not displayed on the XP-Remote.
History Alarm Viewer Since the reasons as shown below, it can be displayed in the different
History Alarm Viewer.
1.
Line down / up, and page down / up, operation of the filtering operation
is not affecting the device value. It is only intended to change the
behavior when you run the historical alarm view. Most of the special
switch operation XP-Remote side individually operated without affecting
each other. For example, if you have a history of alarm side will be
deleted from the XGT Panel alarm history data in the SRAM. The SRAM data
is deleted, but not the XP-Remote (PC) side has to be removed
2.XGT Panel / XP-Remote alarm occurs, the number of occurrences and the time
that occurs between order may be displayed differently. It is a monitoring
device reads the destination specified period of operation that made
history alarm is generated and recovered. In the case of XGT Panel it will
enable loading of the device being monitored, depending on the
controller's communication controller driver settings (monitoring cycle
alarm / timeout / retry count).
If the alarm monitoring target devices quick On / Off toggle XP side, but
the moment of alarm detection, XP-Remote side cannot get caught occur.
If an alarm occurs XGT Panel side to "A, B, C" sequence, XP-Remote side "B,
C, A" alarm may occur in the order.
Alarm / recovery time of the XGT Panel are written based on the current
time of XGT Panel, alarm generation / recovery time in the XP-Remote is
because the records based on the current time of your PC, you can have
different information displayed to each other.
Logging Trend Graph Logging that is old and deleted may be displayed in a different figure.
Logging Distribution
Graph
For logging that is old and deleted, it may be displayed in a different
figure.
Trend Graph Since the time of data collection is different, it can be displayed in a
different graph.
Real-Time Distribution
Graph
Since the time of data collection is different, it can be displayed in a
different graph.

 

알아두기
(1) If you have other problems in addition to behavior differences that are defined in the table, you must
update to the latest version of the XP-Remote.
(2) The same as the version of XP-Remote with the XGT Panel connected, or a higher version, you must be able
to operate as XGT Panel.
(3) You can check the current version of the XP-Remote from the Menu ([Help] - [XP-Remote Information]).

 

64

65
Annex 1. Problem Solving
1.1. Problem Types
This annex describes problems that might occur during the use of the XP-Remote and solution methods to
those problems. Refer to the following problems.

Problem Category Description
communication Problems Communication is not performed between the XP-Remote and the XGT Panel
☞ Refer to 1.2 communication Problems
Control Right Problems Functions related to the control right do not work well
☞ Refer to 1.3 Control Right Problems

 

66

1.2 Communication Problems
1.2.1 The XGT Panel communication connection does not work well on the XP-Remote.
Phenomenon Record When communicating, the following error messages appear:
<Cause>
More than one of the following examples is the cause of the problem.
1) The XGT Panel with an applicable IP address of the object node does not exist on the network.
2) No ethernet cable is connected with the XGT Panel.
3) The ethernet cable is not correct. It might be short cut or disconnected.
4) The network administrator blocks UDP/IP connection.
5) The object XGT Panel’s IP band is not equal to the gateway band set up on the PC.
6) The XGT Panel is not in the monitor mode.
7) The computer’s Window firewall blocks the XP-Remote communication.
8) The XGT Panel’s version is less than 1.30.
9) "XP-Remote <-> HMI <-> PLC" if the connection is active communication between the PLC and HMI
termination or due to an HMI PLC Nak error cannot be normal communication. Due to this XP-Remote cannot
communicate with the HMI properly.
<Solution>
1) Connect the ethernet cable with the object node’s XGT Panel to join it in the network.
2) Connect the XGT Panel’s ethernet cable.
3) Check the wiring status of the ethernet cable and check its movement. In case that the XGT Panel and
the PC are directly connected and they use cross cable hub, use direct cables.
4) Contact the network administrator.
5) Change the XGT Panel’s IP. Since IP Address can conflict, contact the network administrator.
6) Convert to the XGT Panel’s monitor mode.
7) Change the computer’s Window [Control edition] firewall settings to cancel the blocked items related
to the XP-Remote.
8) The XP-Remote connection is supported from the XGT Panel version 1.30 or higher. Upgrade the XGT Panel.
9) Therefore, after the communication between the "HMI <-> PLC" a normal opening, please use the XP-Remote
again.

Note

67

(1) Most of communication connection problems occur under the conditions above. If the same problem occurs
even after taking the actions above, contact LSIS customer center.

1.3 Control Right Problems
1.3.1 Switches on the screen are not pressed.
Phenomenon Record Switches or number input on the drawing screen do not pressed down.
<Cause>
1) The control right is not obtained.
<Solution>
1) Obtain the control right. For details, refer to “Chapter 5 Online” of the User’s Manual.
1.3.2 Even though the control right is obtained, it is not controlled from a certain moment.
1.3.3
Phenomenon Record After the control right is obtained, it is not controlled any more from a certain
moment.
moment. The following messages appear.
<Cause>
1) The control right is forcefully taken from the XGT Panel by pressing the [Disable control by XP-Remote]
button by somebody.
<Solution>
1) After checking if there is the control right by asking the site operator who is near the XGT Panel, and
if not, obtain it again.

68