Manual XP
Right choice for ultimate yield
LSIS strives to maximize customers' profit in gratitude of choosing us for your partner.
Human Machine Interface
XGT Panel
User’s Manual
Read this manual carefully before
installing, wiring, operating, servicing
or inspecting this equipment.
Keep this manual within easy reach
for quick reference.
XGT Panel Series
http://eng.lsis.biz
XP30-BTE
XP30-BTA
XP30-TTE
XP30-TTA
XP40-TTE
XP40-TTA
XP50-TTE
XP50-TTA
XP70-TTA
XP80-TTA
XP90-TTA
Safety Precautions
1 |
Before using the product…
To use the product safely and effectively, please read this instruction manual thoroughly before use.
► Please keep to the safety precaution, for it is to prevent accidents and potential danger from
occurring.
► Safety precaution is classified into ‘Warning’ and ‘Caution’ and their meanings are as follows.
Violating the instruction may result in serious personal injury or death.
Violating the instruction may result in slight personal injury or product
damage.
► The indicated illustrations on the product and in the manual have the following meanings.
Be cautious, for danger may be present.
Be cautious, for there is a possibility of an electric shock.
► After reading the instruction manual, keep it handy for quick reference.
Warning
Caution
Safety Precautions
2 |
Design Precautions
Design Precautions
Installation Precautions
Install a safety circuit external to the HMI to protect the whole control system in case of
external power supply trouble.
Serious trouble may occur to the entire system due to erroneous output/operation of the HMI.
Warning
In/output signal or communication cable should be at least 100mm apart from
High-voltage/power wires.
Otherwise, it may cause erroneous output/operation.
Use the HMI in an environment that meets the general specification contained in this
manual or datasheet.
Otherwise, it could result in electric shock, fire, erroneous operation or deterioration.
In case of much vibration in the installed environment, be sure to insulate the HMI from
direct vibration.
Otherwise, it could result in electric shock, fire or erroneous operation.
Be sure not to let foreign substances such as conductive debris inside the product.
Otherwise, it could result in electric shock, fire or erroneous operation.
Caution
Caution
Safety Precautions
3 |
Wiring Precautions
Be sure to turn off the HMI and external power before wiring.
Otherwise, it may result in an electric shock or damage to the product.
Wire correctly by checking each of the product’s rated voltage and terminal layout.
Otherwise, it may result in fire, electric shock or erroneous operation.
Tighten terminal screws with specified torque when wiring.
If terminal screws are loose, it may result in short circuits, fire or erroneous operation.
Use the exclusive HMI 3-type grounding for the FG terminal.
If not grounded, it may result in erroneous operation.
Be sure not to let any foreign substances such as wiring debris inside the module.
Such debris may cause fire, damage or erroneous operation.
Caution
Warning
Safety Precautions
4 |
Startup and Maintenance Precautions
Disposal Precaution
Do not touch the terminals while power is on.
Otherwise, it may cause electric shock or erroneous operation.
Turn off the PLC and external power when cleaning or tightening the terminal.
Otherwise, it may cause electric shock or erroneous operation.
Do not charge, disassemble, heat, short circuit, solder, etc. the battery.
Mishandling the battery may cause overheating, crack, fire and may result in injury or fire.
Do not disassemble PCB from the product case or modify the product.
Otherwise, it may result in fire, electric shock or erroneous operation.
Use cellular phone or walky-talky at least 30cm away from the PLC.
Otherwise, it may result in erroneous operation.
When disposing of this product or battery, treat it as industrial waste.
Otherwise, it may cause poisonous pollution or explosion.
Warning
Caution
Caution
Revision History
Revision History
Version Date Contents Revised location
V1.0 ‘07.4 First Edition -
V2.0 ’09.10 1. Initial screen changed (horizontal bar -> square box type)
2. Menu name of initial screen changed
(Download From USB -> Storage Download)
3. Selecting one project file among many project files is available
4. Sending project file by CF card is available
5. File backup function by external storage equipment added
6. Format of backup file is changed into CSV format
7. New module XP80-TTA/AC added
8. Project upload function by external storage equipment added
9. Update function by external storage equipment added
10. XP30-BTE interface added
11. Figure and name of each part for XP30-BTE added
12. Specification of XP30-BTE added
13. Aux diagnosis function added
14. Dimension of XP30-BTE added
15. Specification of XP90-TTA/AC, XP70/80-TTA/DC added
16. Dimension of XP90-TTA/AC, XP70/80-TTA/DC added
17. PLC communication setting option in device menu added
18. Multi-Touch function in environment setting added
CH4, CH5, CH6, CH8
CH7.1
CH7
CH7
CH9
CH9
CH3, CH12, APP2
CH7
CH7
CH1
CH2
CH3
CH5
APP2
CH3, CH10
APP2
CH6.7
CH4.1
V2.1 ’10.06 1. XP30-TTE/DC added
2. Clear Data function in Environment Setting added
CH2.1, CH3.2, CH10
CH4.7
V2.2 ’11. 06 1. XP50-TTE/DC added CH2.1, CH3.2, CH10
V2.3 ’12. 06 1. XP40-TTE(TTA)/DC added
2. Important User Information added
(about protection sheet and using ferrite core)
3. CE Standard Certification updated
CH2,CH3.2,CH5,CH10
CH10.1, CH10.2
CH12.1
※ The number of User’s manual is indicated the right side of the back cover.
ⓒLS Industrial Systems Co., Ltd 2006 All Rights Reserved.
Contents
8 |
Chapter. 1 General Introduction ..................................................................................... 1-1~1-6
1.1 Usage of User Manual ................................................................................................................................................. 1-1
1.2 Feature .......................................................................................................................................................................... 1-2
1.3 Terminology ................................................................................................................................................................... 1-6
Chapter. 2 System Configuration ..................................................................................... 2-1~2-6
2.1 Name and Function of Each Part ................................................................................................................................ 2-1
2.2 System Configuration ................................................................................................................................................... 2-5
Chapter. 3 Standard Specification ................................................................................. 3-1~3-7
3.1 General Standards ........................................................................................................................................................ 3-1
3.2 Function Standards ....................................................................................................................................................... 3-3
Chapter. 4 System Configuration .................................................................................. 4-1~4-6
4.1 Touch Calibration .......................................................................................................................................................... 4-1
4.2 Backlight Setting ........................................................................................................................................................... 4-2
4.3 Date Time Setting ......................................................................................................................................................... 4-3
4.4 PC Connection Setting ................................................................................................................................................. 4-3
4.5 Ethernet Setting ............................................................................................................................................................ 4-4
4.6 Contrast Setting (only for XP30-BTA/DC) ................................................................................................................... 4-5
4.7 Environment Setting ..................................................................................................................................................... 4-5
Chapter. 5 Diagnostics .................................................................................................... 5-1~5-6
5.1 Screen Diagnosis ......................................................................................................................................................... 5-1
5.2 Touch Diagnosis ........................................................................................................................................................... 5-2
5.3 Backup Memory Diagnosis .......................................................................................................................................... 5-2
5.4 Flash Memory Diagnosis Function .............................................................................................................................. 5-3
5.5 CF Card Diagnosis ....................................................................................................................................................... 5-3
5.6 Serial Communication Diagnosis ................................................................................................................................. 5-4
5.7 LED Diagnosis .............................................................................................................................................................. 5-6
5.8 Aux Diagnosis ............................................................................................................................................................... 5-6
Chapter. 6 Viewing Information of PLC Connection Status ..................................... 6-1~6-8
Contents
9 |
6.1 Connection Information ................................................................................................................................................ 6-2
6.2 PLC Information ............................................................................................................................................................ 6-3
6.3 History of PLC Error .................................................................................................................................................... 6-4
6.4 History of PLC Mode Conversion .............................................................................................................................. 6-5
6.5 History of PLC Power ................................................................................................................................................. 6-6
6.6 History of PLC System ............................................................................................................................................... 6-7
6.7 PLC Communication Configuration Settings ............................................................................................................ 6-8
Chapter. 7 Storage Function................................................................................................... 7-3
7.1 General Introduction ................................................................................................................................................... 7-1
7.2 Downloading Project through the Storage Equipment ............................................................................................... 7-2
7.3 Uploading Project through the Storage Equipment .................................................................................................... 7-2
7.4 Updating the Device through Storage Equipment ...................................................................................................... 7-3
Chapter. 8 XGT Panel S/W Update ......................................................................................... 8-1
8.1 General Introduction ................................................................................................................................................... 8-1
Chapter. 9 File Backup through External Storage Equipment .......................................... 9-5
9.1 Path Structure in case of File Backup .......................................................................................................................... 9-1
9.2 Operation setting when there is no Space for Backup................................................................................................ 9-3
9.3 Monitoring Connection Status of External Storage Equipment .................................................................................. 9-4
Chapter. 10 Installation and Wiring .......................................................................... 10-1~10-10
10.1 Installation ................................................................................................................................................................. 10-1
10.1.1 Installation environment ................................................................................................................................. 10-1
10.1.2 Notice in handling ........................................................................................................................................... 10-2
10.1.3 Notice in installing the panel .......................................................................................................................... 10-2
10.2 Wiring ........................................................................................................................................................................ 10-6
10.2.1 Power wiring ................................................................................................................................................... 10-6
10.2.2 Ground wiring ............................................................................................................................................... 10-10
Chapter. 11 Maintenance ............................................................................................. 11-1~11-3
11.1 Maintenance............................................................................................................................................................... 11-1
11.2 Daily Maintenance ..................................................................................................................................................... 11-1
11.3 Periodical Maintenance ............................................................................................................................................. 11-2
Contents
10 |
Chapter. 12 EMC Standard Certification ................................................................. 12-1~12-2
12.1 Requirement for EMC Standard Certification ........................................................................................................ 12-1
12.1.1 CE standard certification .............................................................................................................................. 12-1
12.1.2 MIC standard certification ............................................................................................................................ 12-2
12.2 Requirement for Low Voltage Command Suitability ............................................................................................... 12-2
12.2.1 Standard applied for XGT Panel ................................................................................................................... 12-2
12.2.2 Selection of XGT Panel ............................................................................................................................... 12-2
Appendix 1. Troubleshooting ..................................................... Appendix1-1~Appendix1-18
1. Type of Problem .............................................................................................................................................. Appendix 1-1
2. Problem when Starting ................................................................................................................................... Appendix 1-1
3. Reaction Problem when touching .................................................................................................................. Appendix 1-2
4. Display Problem of Figure and Object ........................................................................................................... Appendix 1-2
5. Communication Problem ................................................................................................................................Appendix 1-5
6. CF/USB Removal of Memory Card ............................................................................................................... Appendix 1-6
7. Error Message during Execution of Program ................................................................................................ Appendix 1-7
Appendix 2. Dimension ............................................................... Appendix 2-1~ Appendix 2-4
Chapter 1. General Introduction
1-1
Chapter 1. General Introduction
1.1 Usage of User Manual
This manual provides information of each product’s specification, usage and so on. This is necessary to use XGT Panel for medium
and large HMI system.
The user manual’s configuration is as follows.
Sequence | Category | Contents |
Chapter 1 | General Introduction | It describes this manual’s configuration, product’s feature and term. |
Chapter 2 | System Configuration | It describes feature and system configuration of each XGT Panel. |
Chapter 3 | Standard Specification | It describes XGT Panel’s general and function specification. |
Chapter 4 | System Configuration | It describes XGT Panel’s system configuration. |
Chapter 5 | Diagnostics | It describes XGT Panel’s self-diagnosis. |
Chapter 6 | Viewing information of PLC Connection Status |
It describes the way on connection status information of PLC which is connected with XGT Panel. |
Chapter 7 | Transmission of Project from USB Storage Device |
It describes the way to execute the project by using USB storage device. |
Chapter 8 | XGT Panel S/W Update | It describes the way to update engine at XGT Panel. |
Chapter 9 | Backup files by using Storage Devices |
It describes the way to backup recipe, logging and etc. files by using storage devices. |
Chapter 10 | Installation and Wiring | It describes an installation, wiring and caution for reliability of PLC system. |
Chapter 11 | Maintenance | It describes inspection category and method for long normal operation of PLC system. |
Chapter 12 | EMC Standard | It describes system configuration for EMC standard. |
Appendix 1 | Troubleshooting | It describes a variety of error contents and measure. |
Appendix 2 | Dimension | It describes the dimension of XGT Panel. |
Appendix 3 | Warranty and Environment Policy |
- |
Remark
This manual doesn’t describe connection with XP-Builder and PLC. For their own function, Please refer to the related
manuals.
Chapter 1. General Introduction
1-2 |
1.2 Feature
XGT Panel has the following features.
(1) | Diverse external interface (a) It maximizes custom’s use by providing diverse external interface including USB, CF card and Ethernet. |
(b) It can be connected with control device such as PLC, INVERTER.
• It can be connected by RS-232C, RS-422/485, Ethernet (10/100 BASE-T).
Ethernet
Open network
• Inverter
• Inverter
CF card
Memory Interface
Logging data
Image/font data
Expansion connector
USB host Etc.
Printer Tool port (RS-232C): XP-Builder
USB Storage
Device
Keyboard,
Mouse
Communication
Module
Chapter 1. General Introduction
1-3
(c) XP30-BTE(TTE), economic type, is not supportedfor Ethernet, expansion connector and CF card.
(2) Based on Windows CE
(a) Adoption of Microsoft Company’s Windows CE
• Windows CE 5.0
(b) Advantage
• It provides stable software capacity by using Microsoft Company’s platform.
• It can process diverse function simultaneously.
• It provides diverse interface including Ethernet, USB, and CF card.
• The user interface including mouse and keyboard can be connected.
• It has high flexibility like computer software.
• Fast reaction is available when adding new equipment.
•Wide data sharing and management with upper system is available. (Later)
(3) Improvement of project transmission time
(a) It provides Ethernet which is faster than RS-232C.
(b) It provides the transmission function from USB storage device.
(4) High quality screen
(a) It provides the high quality screen and clearness by high quality LCD.
Download
Upload
Data change
RS232C
RS422/RS485
Terminal Block Type
Battery Cover
USB Port
Chapter 1. General Introduction
1-4 |
• It adopts TFT LCD which supports the 65,536 colors. (XP30-BTE/DC and XP30-BTA/DC adopts STN Mono LCD.)
(b) It provides diverse graphic type.
• It is available to express precisely and actually.
• It provides the simple moving function with GIF support.
(5) Analog touch Panel
(a) It adopts analog (resistor film method) Touch Panel.
• Visibility is improved without the grids.
(b) It provides high touch resolution.
• It can control Touch Panel precisely.
(6) Multilingual and diverse font
(a) It supports the multilingual function.
• It transmits the Windows/User font used in computer to XGT Panel.
• Additional language development is not necessary.
• Multilingual language is an advantage of Windows CE.
(b) It can express four kinds of language simultaneously.
• It can express 8 kinds of language simultaneously.
• Language switching is available by using special switch during operation.
(c) It can provide the various fonts.
• Various expressions are available by using the Windows/User font.
• Font size and type can be adjusted freely.
Chapter 1. General Introduction
1-5
(7) Advanced function
(a) Alarm function
• The History alarm can be classified alarm group and alarm list and selected alarm can be expressed byalarm search.
• The Flow alarm indicates current or the latest alarm at the bottom of screen.
• The System alarm indicates the important problems from operation.
(b) Logging function
• It provides conditional logging according to device condition and continuous periodic logging which operates periodically
according to time and device status.
• It provides 255Kbyte areas for backup.
• Backup into CF card or USB storage device is available.
• Backup data’s type is stored in Excel, it is easyto use.
(c) Recipe function
• It provides READ/WRITE function.
• A recipe provides Max. 100 DWORDs and 16 blocks.
• Backup into the CF card or USB storage device is available.
• Backup data’s type is stored in Excel, it is easyto use.
(d) Scheduler function
• It can be set up to Max. 32.
(e) Print function
• It provides a Screen/Alarm print function.
• It can be printed by USB printer.
(f) Script function
• It provides more flexible function by user Script.
• It can be diversely applied to such as including Global/Object/Screen indication and so on.
(8) Stable product suitable for international standards
(a) CE, KC standard acquisition
(b) UL(cUL) standard acquisition
Chapter 1. General Introduction
1-6 |
1.3 Terminology
It describes terms used in this manual.
Term | Definition | Example |
Module | A standard element that has a specified function which configures the system. Devices such as I/O board, which inserted onto the mother board or base unit. |
Ex.) CPU module Power module, I/O module |
Unit | A single module or group of modules that perform an independent operation as a part of PLC system. |
Ex.) Basic unit, Extension unit |
PLC system | System consisted of PLC and peripheral device which can be controlled by user program. |
- |
XP-Builder | Software used to write and edit the project. | - |
Cnet module | Computer Link | - |
FEnet module | Fast Ethernet Network | - |
RTC | Abbreviation of ‘Real Time Clock’. It is used to call general IC that contains clock function. |
- |
Chapter 2. System Configuration
2-1 |
Chapter 2. System Configuration
Here describes the feature of XGT Panel and system configuration.
2.1 Name and Function of Each Part
1. XP30-BTA, XP30/50/70/80-TTA
Number | Name | Description |
① | Front view | 1) Analog touch panel: User touch input 2) LCD: screen indication |
Chapter 2. System Configuration
2-2 |
Number | Name | Description |
② | LED Status | Indicates operation status of device |
Green | Normal RUN status (monitoring, downloading the project data) Initializing the status when booting (HMI does not operate) |
|
Red | Error occurs (communication error, project data error) |
|
③ | Panel fixed part | XGT Panel is fixed at panel by bracket. |
④ | CF card interface | 1) Logging/recipe/screen data backup 2) Upgrade of windows CE is available. |
⑤ | Power connection terminal | It consists of power input and FG terminal. |
⑥ | USB interface | It consists of 2 ports. 1) USB memory connection: logging/recipe/screen data backup 2) USB memory connection: project data transmission/backup 3) User interface connection: use of mouse/keyboard 4) Printer connection: printing is available |
⑦ | Extension port | Extension module installation |
⑧ | Reset switch | Hardware reset switch |
⑨ | TOOL interface | RS-232C interface 1) project data transmission 2) logging/recipe/alarm/screen data backup 3) machine software upgrade |
⑩ | Setting switch | Device setting switch |
No.1 | Reserved | |
No.2 | A setting | Normal operation (default) |
B setting | When upgrading Windows CE | |
No.3 | A setting | Watchdog On (default) |
B setting | Watchdog Off | |
No.4 | A setting | RS-422/485 Terminal Switch On (120Ω) |
B setting | RS-422/485 Terminal Switch Off (120Ω) | |
⑪ | Extension module fixation hall | Extension module fixation hall |
⑫ | RS-422/485 connector | RS-422/485: PLC/control machine communication |
⑬ | RS-232C connector | RS-232C: PLC/control machine communication |
⑭ | Ethernet terminal | Ethernet: 10Base-T / 100Base-TX 1) Project data transmission 2) logging/recipe/alarm/screen data backup 3) machine software upgrade 4) PLC/control machine communication |
⑮ | FG terminal | FG terminal hole for extension module |
Remark
(1) For details about communication connection, please refer to the communication user manual.
(2) For details about installation, please refer tothe Chapter 10
Chapter 2. System Configuration
2-3 |
When you use the XGT Panel, the prevention tape is installed to prevent battery discharge.
If you remove this prevention tape, backup is available.
In order to remove tape, pull tape downward like the following figure.
2. XP30-BTE, XP30-TTE, XP50-TTE, XP40-TTA(TTE)
Prevention
tape
⑫ ⑪
Chapter 2. System Configuration
2-4 |
Number | Name | Description |
① | Front view | 1) Analog touch panel: User touch input 2) LCD: screen display |
② | LED Status | Indicates operation status of module. |
Green | Normal RUN status (monitoring, downloading the project data) Initializing mode when booting (HMI does not Ready) |
|
Red | Error occurs (communication error, project data error) |
|
③ | Panel fixed part | XGT Panel is fixed at panel by bracket. |
④ | Power terminal cover |
Prevention from electric shock |
⑤ | USB interface | 1) USB memory connection: logging/recipe/screen data backup 2) USB memory connection: project data transmission/backup 3) User interface connection: use of mouse/keyboard 4) Printer connection: printing is available |
⑥ | Communication interface |
RS-232C, RS-422/485: For communication with controller (PLC) |
⑦ | Reset switch | Hardware reset switch |
⑧ | Battery cover | Open or close when replacing the battery |
⑨ | Tool interface | RS-232C interface 1) Project data transmission 2) Logging/recipe/alarm/screen data backup 3) Machine software upgrade |
⑩ | Setting switch | Module setting switch |
No.1 | Reserved | |
No.2 | A setting | Normal operation (default) |
B setting | When upgrading Windows CE | |
No.3 | A setting | Watchdog On (default) |
B setting | Watchdog Off | |
No.4 | A setting | RS-422/485 Terminal Switch On (120Ω) |
B setting | RS-422/485 Terminal Switch Off (120Ω) | |
⑪ | Power terminal | It consists of power input and FG terminal |
⑫ | Ethernet terminal | Ethernet: 10Base-T / 100Base-TX 1) Project data transmission 2) logging/recipe/alarm/screen data backup 3) machine software upgrade 4) PLC/control machine communication ※ Supported on XP40-TTA |
Chapter 2. System Configuration
2-5 |
2.2 System Configuration
In order to use XGT Panel, write project data at the XP-Builder and transmit it to the XGT Panel.
XGT Panel can be basically connected through RS-232C.
Maximum communication speed is 115,200 [bps].
RS-232C communication speed is not fast so it takes long time to transmit project data into XGT Panel.
Project data can be quickly transmitted through Ethernet.
When LAN system is configured like the following figure, you can use it easily and effectively.
In case that LAN system is not configured, it provides 1:1 connection. (LAN cable should be cross cable.)
LAN
Ethernet
Chapter 2. System Configuration
2-6 |
When communication is not available to transmit project data, USB storage device is available
For details, please refer to the Chapter.7 and XP-Builder user manual.
Remark
1) We recommend Ethernet more than RS-232C.
2) For the Ethernet cable manufacture, please referto the communication manual.
3) For the project transmission method, please refer to the XP-Builder manual.
4) Ethernet is not supported on XP30-BTE, XP30-TTE, XP50-TTE and XP40-TTE.
Chapter 3. Standard Specification
3-1 |
Chapter 3. Standard Specification
3.1 General Standards
XGT Panel’s general standard is as follows.
No. | Category | Standard | Related standard | |
1 | Ambient operating temperature |
0℃∼+50℃ | - | |
2 | Storage temperature |
-20℃∼+60℃ | - | |
3 | Operating humidity |
10∼85%RH, non-condensing. | - | |
4 | Storage humidity |
10∼85%RH, non-condensing. | - | |
5 | Vibration resistance |
Occasional vibration | count | - |
Frequency | Acceleration | Amplitude | 10 times for each X, Y, Z axis |
IEC 61131-2 |
5 ≤ f < 9㎐ | - | 3.5 mm | ||
9 ≤ f ≤ 150㎐ | 9.8㎨ | - | ||
Continuous vibration | ||||
Frequency | Acceleration | Amplitude | ||
5 ≤ f < 9㎐ | - | 1.75 mm | ||
9 ≤ f ≤ 150㎐ | 4.9㎨ | - | ||
6 | Shock endurance |
* Maximum shock acceleration: 147㎨ (15G) * Duration time: 11㎳ * Pulse wave: half sine pulse (3 shocks per axis, on X, Y, Z axis) |
IEC 61131-2 | |
7 | Noise Immunity |
Square wave Impulse noise |
AC: ±1,500V DC: ±1,000V |
LSIS Standard |
Electrostatic discharge Immunity |
±6 kV (Discharge by contact) | IEC 61131-2 IEC 61000-4-2 |
||
Radiated electromagnetic field noise |
80 ~ 1000 MHz, 10 V/m | IEC 61131-2 IEC 61000-4-3 |
||
Fast transient & Burst noise |
Category | Power module | Communication interface |
IEC 61131-2 IEC 61000-4-4 |
Voltage | 2 kV | 1 kV | ||
8 | Environment | Free from corrosive gases and excessive dust | - | |
9 | Operating height |
Up to 2,000m (6,562 ft) | - | |
10 | Pollution degree | Less than 2 | - | |
11 | Cooling method | Air-cooling | - |
Chapter 3. Standard Specification
3-2 |
Remark | |
(1) IEC(Intern : Internat standa (2) Pollution d : As an in general tempor (3) Radiated (All others |
ational Electro technical Commission) ional private group facilitating international cooperation of electric/electronic standardization, issuing international rds and operating the compliance evaluation systems. egree dex representing the pollution degree of an environment to determine the insulation of a device, pollution degree 2 ly means the status generating non-conductive contamination. However, it also contains the status generating rily conduction due to condensation. electromagnetic field noise for XP30-BTE(TTE) is 80 ~ 1000MHz, 10 V/m are same as shown on the table) |
(1) General Specification for XP40-TTA(TTE)
No. | Category | Standard | Related standard | |
1 | Operating Temperature |
0℃∼+50℃ | - | |
2 | Storage Temperature |
-20℃∼+60℃ | - | |
3 | Operating Humidity |
10∼85%RH, non-condensing. | - | |
4 | Storage Humidity |
10∼85%RH, non-condensing. | - | |
5 | Vibration Resistance |
Occasional vibration | count | - |
Frequency | Acceleration | Frequency | 10 times for each X, Y, Z axis |
IEC 61131-2 |
5 ≤ f < 9㎐ | - | 5 ≤ f < 9㎐ | ||
9 ≤ f ≤ 150㎐ | 9.8㎨(1G) | 9 ≤ f ≤ 150㎐ | ||
Continuous vibration | ||||
Frequency | Acceleration | Frequency | ||
5 ≤ f < 9㎐ | - | 5 ≤ f < 9㎐ | ||
9 ≤ f ≤ 150㎐ | 4.9㎨(0.5G) | 9 ≤ f ≤ 150㎐ | ||
6 | Shock Endurance |
* Maximum shock acceleration: 147㎨ (15G) * Duration time: 11㎳ * Pulse wave: half sine pulse (3 shocks per axis, on X, Y, Z axis) |
IEC 61131-2 | |
7 | Noise Immunity |
Square wave Impulse noise |
DC: ±800V | - |
Electrostatic discharge Immunity |
±4kV (Contact discharge) | IEC61000-4-2 | ||
Radiated electromagnetic field noise |
80 ~ 1,000 MHz, 10 V/m | IEC61131-2 IEC61000-4-3 |
||
Fast transient & Burst noise |
Category | Power module | Communication interface |
IEC61131-2 IEC61000-4-4 |
Voltage | 2 kV | 1 kV | ||
8 | Environment | Free from corrosive gases and excessive dust | - | |
9 | Operating height |
Up to 2,000m (6,562 ft) | - | |
10 | Pollution degree |
2 or less | - |
Chapter 3. Standard Specification
3-3 |
11 | Cooling method |
Air-cooling | - |
3.2 Function Standards
XGT Panel’s function standard is as follows.
1. DC type
(1) 5.7 Inches Models
Item | XP30-TTE/DC | XP30-BTE/DC | XP30-BTA/DC | XP30-TTA/DC |
Display type | TFT LCD | STN mono LCD | TFT Color LCD | |
Screen size | 14 ㎝ (5.7”) | |||
Display Resolution | 320 x 240 pixel | |||
Color indication | 256 Colors | 8 step Gray Scale | 65,000 Colors | |
Indication degree | Left/Right: 80 deg. Upper: 70 deg. Lower: 70 deg |
Left/Right: 45 deg. Upper: 20 deg. Lower: 40 deg |
Left/Right: 80 deg. Upper: 70 deg. Lower: 70 deg. |
|
Backlight | LED Type | |||
Backlight duration | 50,000 hours | |||
Contrast | - | Adjust through touch/parameter | - | |
Brightness | 600cd/㎡ | 230cd/㎡ | 600cd/㎡ | |
Touch panel | 4 – Line type, analog | |||
Sound Output | Magnetic buzzer | |||
Process | ARM920T (32bit RISC), 200MHz | |||
Graphic accelerator | Hardware Accelerator | |||
Memory | Flash | 16MB | 32MB | |
Operating RAM | 32MB | 64MB | ||
Backup RAM | 128KB | 512KB | ||
Backup data | Date/Hour data and Logging/Alarm/Recipe data | |||
Battery duration | Approx. 3 years (Operating ambient temperature of 25℃) | |||
Ethernet | - | 1 Channel, IEEE802.3, 10Base-T/100Base-TX | ||
USB Host | 1 Channel | 2 Channels, USB 2.0 (printer, USB memory stick driver is available) |
||
RS-232C | Terminal Block | 2 Channels | ||
RS-422/485 | Terminal Block | 1 Channel,RS-422/485 mode | ||
CF Card | - | 1 Slot (Compact Flash) | ||
Expansion module | - | Option module is available | ||
Multi-language | Up to 8 language simultaneously | |||
Animation | GIF format is available |
Chapter 3. Standard Specification
3-4 |
Item | XP30-TTE/DC | XP30-BTE/DC | XP30-BTA/DC | XP30-TTA/DC |
Recipe | available | |||
Data logging | available | |||
Script executor | available | |||
Certifications | CE, UL, KC | |||
Protection standard | IP65F | |||
Dimension (mm) | 181 x 140 x 56.5 | 181 x 140 x 66.5 | ||
Panel cut (mm) | 156 x 123.5 | 156 x 123.5 | ||
Rated voltage | DC24V (Actual Range: 19.2 ~ 28.8V) | |||
Power consumption (W) | 5 | 8.5 | ||
Weight(Kg) | 0.62 | 0.75 |
(2) 7 Inches Models
Item | XP40-TTE/DC | XP40-TTA/DC | |
Display type | TFT Color LCD | ||
Screen size | 7” (17.7㎝) | ||
Display Resolution | 800 x 480 pixel | ||
Color indication | 256 Colors | 65,536 Colors | |
Indication degree | Left/Right: 65 deg. Upper: 50 deg. Lower: 60 deg. |
||
Backlight | LED (Replaceable) | ||
Backlight duration | Above 30,000 hours | ||
Brightness | 280cd/㎡ | ||
Touch panel | Analog | ||
Sound Output | Magnetic Buzzer | ||
Process | ARM920T (32bit RISC), 200MHz | ||
Graphic accelerator | Hardware Accelerator | ||
Memory | Flash | 16MB | 32MB |
Operating RAM | 32MB | 64MB | |
Backup RAM | 128KB | 512KB | |
Backup data | Date/Hour data and Logging/Alarm/Recipe data | ||
Battery duration | Approximately 3 years (Operating ambient temperature of 25℃) | ||
Ethernet | - | 1 Channel, IEEE802.3, 10Base-T/100Base-TX | |
USB Host | 1 Channels, USB 2.0 (printer, USB memory stick driver is available) |
||
RS-232C | Terminal Block | ||
RS-422/485 | Terminal Block |
Chapter 3. Standard Specification
3-5 |
Item | XP40-TTE/DC | XP40-TTA/DC |
Multi-language | Up to 8 language simultaneously | |
Animation | GIF format is available. | |
Recipe | Available | |
Data logging | Available | |
Script executor | Available | |
Certifications | CE, UL(cUL), KC | |
Protection standard | IP65F | |
Dimension (mm) | 203.5x153.5x41.5 | |
Panel cut (mm) | 192 x 138 | |
Rated voltage | DC24V (19.2 ~ 28.8V) | |
Power consumption (W) | Less than 4.5 | Less than 5 |
Weight(Kg) | 0.80 | 0.81 |
(3) 8.4/10.4/12.1 Inches Models
Item | XP50-TTE/DC | XP50-TTA/DC | XP70-TTA/DC | XP80-TTA/DC |
Display type | TFT Color LCD | |||
Screen size | 21 ㎝(8.4”) | 26 ㎝(10.4”) | 31㎝(12.1”) | |
Display Resolution | 640 x 480 pixel | 800 x 600 pixel | ||
Color indication | 256 Color | 65,000 Color | ||
Indication degree | Left/Right: 45 deg. Upper: 20 deg. Lower: 20 deg. |
Left/Right: 65 deg. Upper: 50 deg. Lower: 60 deg. |
Left/Right: 65 deg. Upper: 45 deg. Lower: 65 deg. |
Left/Right: 65 deg. Upper: 45 deg. Lower: 75 deg. |
Backlight | CCFL (Replacement is available), Supporting automatic On/Off | |||
Backlight duration | 50,000 hr. | |||
Brightness | 200cd/㎡ | 480cd/㎡ | 430cd/㎡ | 400cd/㎡ |
Touch panel | 8 Line, analog | |||
Sound Output | Magnetic buzzer | |||
Process | ARM920T (32bit RISC), 200MHz | |||
Graphic accelerator | Hardware Accelerator | |||
Memory | Flash | 16MB | 32MB | |
Operating RAM | 32MB | 64MB | ||
Backup RAM | 128KB | 512KB | ||
Backup data | Date/Hour data and Logging/Alarm/Recipe data | |||
Battery duration | Approx. 3 years (Operating ambient temperature of 25℃) | |||
Ethernet | 1 Channel, IEEE802.3, 10Base-T/100Base-TX | |||
USB Host | 1 Channel | 2 Channels, USB 2.0 (printer, USB memory stick driver is available) | ||
RS-232C | Terminal Block | 2 Channels |
Chapter 3. Standard Specification
3-6 |
Item | XP50-TTE/DC | XP50-TTA/DC | XP70-TTA/DC | XP80-TTA/DC |
RS-422/485 | Terminal Block | 1 Channel, RS-422/485 mode | ||
CF Card | - | 1 Slot (Compact Flash) | ||
Expansion module | - | Option module is available | ||
Multi-language | Up to 8 language simultaneously | |||
Animation | GIF format is available | |||
Recipe | available | |||
Data logging | available | |||
Script executor | available | |||
Certifications | CE, UL, KC | |||
Protection standard | IP65F | |||
Dimension (mm) | 240 x 174 x 63 | 240 x 174 x 73 | 317 x 243 x 73 | |
Panel cut (mm) | 228.0 x 158.0 | 294.5 x 227.5 | ||
Rated voltage | DC24V (Actual Range: 19.2 ~ 28.8V) | |||
Power consumption(W) |
13 | 20 | 27 | 30 |
Weight(Kg) | 1.2 | 1.4 | 2.2 | 2.4 |
Remark | |
(1) Notice in c : Connecti (2) FG conne : Use ⑤F (Except (3) Preventio : There is (4) Battery op : Battery is Because b (5) LCD Back : XP40-TT Howeve replace |
onnecting with power ng AC power to the device using DC power may cause product break or fire. Be careful when connecting ction G terminal (Chapter 2.1) for FG of the device. ⑮FG (Chapter 2.1) is for FG terminal of extension card. XP30-BTE, XP30-TTE and XP50-TTE) n tape of Battery discharge prevention tape is to prevent the battery discharge. In order to use backup, remove the prevention tape. eration and duration used to reserve backup data and RTC (data/time) when power is off. attery is used when power is off, battery is not consumed when power is on. light replacement A(TTE)/DC, XP50-TTA(TTE)/DC, XP70-TTA/DC, XP80-TTA/DC, LCD backlight is replaceable. r in XP30-BTE/DC, XP30-TTE/DC, XP30-BTA/DC and XP30-TTA/DC, LCD backlight is not able because LCD and backlight is all-in-one type. |
Chapter 3. Standard Specification
3-7 |
2. AC Type
(1) 10.4/12.1/15 Inches Models
Item | XP70-TTA/AC | XP80-TTA/AC | XP90-TTA/AC |
Display type | TFT Color LCD | ||
Screen size | 26cm (10.4”) | 31cm (12.1”) | 38cm (15”) |
Display Resolution | 640 x 480 pixel | 800 x 600 pixel | 1024 x 768 pixel |
Color indication | 65,000 Color | ||
Indication degree | Left/Right: 65 deg. Upper: 45 deg. Lower : 65 deg. |
Left/Right: 65 deg. Upper: 45 deg. Lower : 75 deg. |
Left/Right: 75 deg Upper : 50 deg Lower : 60 deg |
Backlight | CCFL (Replacement is available), Supporting automatic On/Off | ||
Backlight Duration | 50,000 hr. | ||
Contrast | - | ||
Brightness | 430cd/㎡ | 400cd/㎡ | 450cd/㎡ |
Touch Panel | 8 Line, analog | ||
Sound Output | Magnetic buzzer | ||
Process | ARM920T (32bit RISC), 200MHz | ||
Graphic Accelerator | Hardware Accelerator | ||
Memory | Flash | 32MB | 64MB |
Operating Ram | 64MB | 128MB | |
Backup Ram | 512KB | ||
Backup data | Date/Hour data and Logging/Alarm/Recipe data | ||
Battery duration | Approx. 3 years (Operating ambient temperature of 25℃) | ||
Ethernet | 1Channel, IEEE802.3, 10Base-T/100Base-TX | ||
USB Host | 2 Channels, USB 2.0 (printer, USB memory stick driver is available) | ||
RS-232C | 2 Channels | ||
RS-422/485 | 1 Channel,RS-422/485 mode | ||
CF Card | 1 Slot (Compact Flash) | ||
Expansion Module | Option module is available | ||
Multi-language | Up to 4 language simultaneously | ||
Animation | GIF format is available | ||
Recipe | available | ||
Data logging | available | ||
Script executor | available | ||
Certification | CE, UL, KCC | ||
Protection standard | IP65F | ||
Dimension (mm) | 317 x 243 x 73 | 395 x 294 x 73 | |
Panel cut (mm) | 294.5 x 227.5 | 383.5 x 282.5 | |
Rated voltage | AC100~240V | ||
Power consumption (W) | 37 | 40 | 46 |
Weight (Kg) | 2.2 | 2.4 | 3.9 |
Chapter 3. Standard Specification
3-8 |
Remark | |
(1) Notice in c : If you con (2) FG conne : Use ⑤F (Except (3) Preventio : There is (4) Battery op : Battery is Because b (5) LCD Back : In XP70 |
onnecting with power nect DC power to the device using AC power, the product doesn’t work. Please be careful when connecting. ction G terminal (Chapter 2.1) for FG of the device. ⑮FG (Chapter 2.1) is for FG terminal of extension card. XP30-BTE , XP30-TTE and XP50-TTE) n tape of Battery discharge prevention tape is to prevent the battery discharge. In order to use backup, remove the prevention tape. eration and duration used to reserve backup data and RTC (data/time) when power is off. attery is used when power is off, battery is not consumed when power is on. light replacement -TTA/AC, XP80-TTA/AC, XP90-TTA/AC, LCD backlight is replaceable. |
Chapter 4. System Configuration
4-1 |
Chapter 4. System Configuration
It describes the system configuration including XGT Panel’s time setting, Ethernet connection setting, and connection with
PC and backlight.
If you press [Settings] button in XGT Panel’s basic screen, you can set XGT Panel’s environment as follows.
XGT Panel’s basic screen XGT Panel’s System Configuration screen
Chapter 4. System Configuration
4-2 |
4.1 Touch Calibration
When the location is not recognized in XGT Panel, Touch’s scale can be adjusted in XGT Panel. If you press [Touch Calibration]
button in System Configuration, the setting screen shows up. If you press five ‘+’ marks, XGT Panel’s touch location adjustment is
completed.
If you press two points simultaneously while [Allow Multi-touch] is selected, XGT Panel recognizes as if middle point between two
points is selected. If you press two points simultaneously while [Allow Multi-touch] is not selected, XGT Panel recognizes as if any
point is not selected.
Remark
(1) XGT Panel’s Touch Calibration setting is basically set. If Touch location error is big, adjusting menu with touch can be
hard through touch. In that case, You can select the Touch Calibration setting menu by USB mouse.
(2) When touch location changes in using, redo touch setting.
(3) If you don’t allow Multi-touch, sensitivity is lower than when allowing Multi-touch.
Chapter 4. System Configuration
4-3 |
4.2 Backlight Setting
If you press [Backlight Setting] button in [System Configuration] screen as follows, setting screen shows up.
Against no use for long time through XGT Panel, you can set ‘Automatically turn off backlight’ function.
Set whether you use backlight automation On/Off function or not and time, then press OK button as follows.
As above, if you input 30, the backlight automatically turns off after 30 minute later. In off status, if you touch the panel, the backlight
turns on.
Chapter 4. System Configuration
4-4 |
4.3 Date Time Setting
If you press [DateTime Setting] button in [System Configuration] as follows, you can set XGT Panel’s data and time.
Remark
You can set data/time at device information of communication dialog at the XP-Builder.
For details, please refer to the XP-Builder’s manual.
Chapter 4. System Configuration
4-5 |
4.4 PC Connection Setting
If you press [PC Conn Setting] button in [System Configuration] screen as follows, you can set RS-232C and TCP/IP’s port number
to communicate with PC.
Remark
The condition is set as the above. No other setting is required. But in case of changing RS-232C’s communication speed,
change as above.
Chapter 4. System Configuration
4-6 |
4.5 Ethernet Setting
If you press [Ethernet Setting] button in [System Configuration] screen as follows, you can change IP to use Ethernet.
You can change IP address by pressing [Set] button of each IP address, Subnet Mask and Gateway. By pressing OK button,
changed IP information is reserved.
Remark
We recommend the following method, when connecting with PC solely.
Ethernet is not supported on XP30-BTE
If you reboot after pressing [Disable] button, the device will not use Ethernet. In this case, booting speed gets faster. If you
use Ethernet again, reboot after pressing [Enable].
1) XGT Panel setting
- IP Address : 192.168.0.10
- Subnet Mask: 255.255.255.0
- Gateway : 192.168.0.1
2) PC setting
- IP Address : 192.168.0.11
- Subnet Mask: 255.255.255.0
- Gateway : 192.168.0.1
Chapter 4. System Configuration
4-7 |
4.6 Contrast Setting (only for XP30-BTA(BTE)/DC)
If you press [Contrast Setting] button on [System Configuration] screen, you can adjust mono LCD’s Contrast.
UP button increase Contrast, DOWN button decrease Contrast. Contrast value is between 0~100.
Adjustment is only available for mono type XP30-BTA/BTE
Adjustment is available during operation.
If you press the screen for 3 second, shows up. You can adjust contrast by pressing button.
Chapter 4. System Configuration
4-8 |
4.7 Environment Setting
If you press [Environment Setting] button in [System Configuration] screen as follows, you can set ‘Auto Goto Screen’ and ‘Buzzer
On/Off’.
When setting [Auto Goto Screen], XGT Panel is rebooted. Or when downloading the edit data is completed, the screen automatically
shows up. If you cancel this setting, the user should press ‘Start’ button in order to move to the screen.
If you select [Quick Start], when starting screen, screen shows promptly without showing progress bar because it doesn’t caching the
image in advance. However, if you select this option, first screen shows slowly. Especially, if there are many animation objects in
screen, it may take several seconds based on image. But fast screen switching is available since second screen switching.
If you select [Hide Mouse Cursor], mouse cursor doesn’t show after screen switching
You can set whether you use buzzer through [Buzzer On/Off] button.
If you set [Disable menu Bar], the menu bar basically provided to go out from monitoring screen to the waiting screen doesn’t show.
In this case, if you want to go out to the waiting screen, you have to use the special switch to close the monitoring screen.
If you select the image through [Set Background Image], background image of waiting screen is set as the selected image. If you
want to cancel, press [Delete Background Image]
If you select [Clear Data], all files downloaded bythe user are deleted. If connection password is set, you have to input the password.
This password is connection password needed for project download, etc. You can set that password in [Communication] [XGT
Panel Information] [Password] tap. The deleted files are user project file, web server, VNC start module, option card driver,
RAPIEnet communication setting data, XP-manager setting data and etc. Setting through Environment Setting menu of device is not
initialized.
Remark
The buzzer can be set at the machine information tap of communication conversation box.
Please refer to the XP-Builder’s manual.
Chapter 5. Diagnostics
5-1 |
Chapter 5. Diagnostics
It describes the diagnosis function for XGT Panel’s communication terminal, screen and touch function.
If you press [Diagnostics] button on the XGT Panel’s basic screen, the menu for diagnosis shows up.
5.1 Screen Diagnosis
If you press [Screen] button, screens continuously change into diverse color with buzzer. For XP30-BTA/DC product, screen
changes into 8 steps’ light. After all screen for diagnosis pass. Then, Close button shows up with white ground.
If you press Close button, the initial screen shows up.
Item | XP30-BTA(BTE) | XP30-TTA(TTE) | XP40-TTA(TTE) | XP50-TTA(TTE) | XP70-TTA | XP80-TTA | XP90-TTA |
Display | BLACK > 8 Gray steps Scale screen > WHITE |
RED > GREEN > BLUE > BLACK > WHITE |
XGT Panel’s basic screen XGT Panel’s environment setting screen
XGT Panel’s XGT Panel diagnosis screen Screen when XGT Panel’s screen diagnosis
Chapter 5. Diagnostics
5-2 |
5.2 Touch Diagnosis
If you touch the screen, the touched location is displayed as follows. If pressing the [OK] button, you can quit the screen.
If the touched location is not correct, reset the Touch setting. For detailed information, please refer to the Chapter 4. System
Configuration.
5.3 Backup Memory Diagnosis
If you press [Backup Memory] button, you can see the result of diagnosis in the result windows.
Remark
(1) If ‘NVRAM Data Access … Fail’ error is occurred, please contact with customer service center.
(2) If ‘BATTERY STATUS … BAD’ error is occurred, battery should be changed. Please contact with Customer service
center.
Chapter 5. Diagnostics
5-3 |
5.4 Flash Memory Diagnosis Function
If you press [NOR Flash] button, you can see the result of diagnosis in the result widows.
Remark
If ‘Read Disk Information Error!’ occurs, please contact with Customer service center.
5.5 CF Card Diagnosis
If you press [CF Card] button, the result of diagnosis shows up in the result windows.
Remark
If ‘Read Disk Information Error!’ occurs, please contact with Customer service center.
CF Card is not supported on XP30-BTE, XP30-TTE, XP50-TTE, XP40-TTA(TTE)
Chapter 5. Diagnostics
5-4 |
5.6 Serial Communication Diagnosis
If you press [Serial] button, you can diagnose Serial ports which is equipped at XGT Panel.
(In case of diagnosis purpose, you have to connect the loop-back terminal at each port.)
The followed feature is Loop Back terminal. In case of communication diagnosis, connect as followed feature.
The tool port terminal should be made as follows.
(Connect the No.2 and 6 pin)
Chapter 5. Diagnostics
5-5 |
The RS-232C port terminal should be made as follows
. (Connect the No.2 and 3 pin) (Connect the TX and RX)
The RS-422/485 port terminal should be made as follows.
(Connect the Pin No.4 with 8 and Pin No. 5 with 9) (Connect the TX+ with RX+ and TX- with RX-)
RSRS-232C RS-422/485
RSRS-232C RS-422/485
Chapter 5. Diagnostics
5-6 |
5.7 LED Diagnosis
If you press [LED] button, you can check whether LED is converted into designated color or not at the bottom of XGT Panel.
5.8 AUX Diagnosis
If you press [Aux Interface] button, you can check the functions of card that is currently connected.
※Not supported on following models: XP30-BTE(TTE), XP50-TTE, XP40-TTA(TTE)
Ch.6 Viewing Information of PLC Connection Status
6-1 |
Chapter 6 Viewing Information of PLC Connection Status
You can see the diverse information including XGT Panel’s and PLC’s CPU information through View PLC Connection Status
Information.
[Method]
(a) Select [PLC Information] in the menu.
(b) Select the designated PLC. The listed PLC is the same as connection number which is set at [Common - Project Property
Setting – PLC/Device settings] in XP-Builder.
(c) Press [SHOW INFO]
(d) You can check the connection information of XGT Panel, information of PLC CPU, history of error, mode conversion, PLC
power cut and system.
Remark
You can check the status of PLC connection after project data is transmitted into XGT Panel.
Ch.6 Viewing Information of PLC Connection Status
6-2 |
6.1 Connection Information
You can check the setting items for the connection with PLC such as Vender of PLC, Target device, Connection type, Connection
information and Timeout value in the XP-Builder.
Ch.6 Viewing Information of PLC Connection Status
6-3 |
6.2 PLC Information
You can check CPU type of PLC, operation mode, state, version, and scan time.
Remark
The following PLC is available for view of PLC information.
- MASTER-K CPU, FEnet, Cnet
- GLOFA-GM CPU, FEnet, Cnet
- XGK/XGB/XGI CPU, FEnet, Cnet
Ch.6 Viewing Information of PLC Connection Status
6-4 |
6.3 History of PLC Error
You can check the PLC Error History.
Remark
The following PLC is available for viewing Error History.
- MASTER-K CPU doesn’t have the Error History.
- GLOFA-GM CPU
- XGK/XGI CPU
- XGB CPU doesn’t have the Error History.
Ch.6 Viewing Information of PLC Connection Status
6-5 |
6.4 History of PLC Mode Conversion
You can check the history about our PLC’s RUN/STOP operation mode.
Remark
The following PLC is available for viewing PLC operation mode conversion history.
- MASTER-K CPU doesn’t have the history about operation mode conversion.
- GLOFA-GM CPU
- XGK/XGI CPU
- XGB CPU doesn’t have the history about operationmode conversion.
Ch.6 Viewing Information of PLC Connection Status
6-6 |
6.5 History of PLC Power
You can check the history about when PLC was turned on and off
Remark
The following PLC is available for viewing the history of when our PLC was turned off and on.
- MASTER-K CPU doesn’t have the history about when our PLC was turned on and off.
- GLOFA-GM CPU
- XGK/XGI CPU
- XGB CPU doesn’t have the history about when our PLC was turned on and off.
Ch.6 Viewing Information of PLC Connection Status
6-7 |
6.6 History of PLC System
You can check history about PLC system.
Remark
The following PLC is available for viewing historyabout system.
- MASTER-K CPU doesn’t have the history about system.
- Only GLOFA-GM CPU (GM4C) has the history about system. Other CPUs don’t have the history about system.
- XGK/XGI CPU
- XGB CPU doesn’t have the history about system.
Ch.6 Viewing Information of PLC Connection Status
6-8 |
6.7 PLC Communication Configuration Settings
You can select [Settings] button to change PLC communication settings
Remark
- For further information about the settings, please refer to the PLC user manual.
- [Program Monitor] button is activated in case of LSIS PLC Direct Driver
Chapter 7. Storage Function
7-1 |
Chapter 7 Storage Function
7.1 General Introduction
Downloading the user project made in XP-Builder from PC, uploading the project stored in the device to PC, updating the device
and etc are available through connection with XGT Panel with Serial cable or Ethernet cable generally. However, when those
connections are not available, you can use CF card, USB storage equipment
1. If you touch [Storage Function], the following dialog box shows.
2. In case of downloading the project by using CF card or USB storage equipment, touch [Project Download] button.
3. In case of transmitting the project data stored in the device to CF card or USB storage equipment, touch [Project Upload]
button.
4. In case of updating the XGT Panel with XGT Panel Software stored in CF card or USB Storage equipment, touch [XGT
Panel Update]
Chapter.7 Storage Function
7-2 |
7.2 Downloading Project through the Storage Equipment
1. If you touch [Project Download], the following dialog shows.
2. In case of selecting [USB], the directory list under the path, USB StorageXP_Project shows. In case of selecting [CF],
the directory list under the path, Storage CardXP_Project shows. In case of downloading the project by using storage
equipment, the project should be saved in the one lower directory between those two directories.
3. Select one among directory lists and touch [OK]. Then downloading will start.
7.3 Uploading Project through the Storage Equipment
1. If you touch [Project Upload], the following dialog shows.
2. In case of selecting [USB], the path, USB StorageXP_Backup, shows. In case of selecting [CF], the path, Storage
CardXP_Backup, shows. Select one between two.
3. If you touch [OK] button, project backup file is transmitted to the selected path.
4. The project backup file is saved when Download project backup file is selected when downloading the project.
If you don’t select, project backup file is not saved in the device and transmission to the storage equipment is not
available.
Chapter 7. Storage Function
7-3 |
7.4 Updating the Device through Storage Equipment
1. If you touch [Project Upload], the following dialog shows.
2. In case of selecting [USB], the directory list under the path, USB StorageXP_Project shows. In case of selecting [CF],
the directory list under the path, Storage CardXP_Project shows. In case of updating the device by using storage
equipment, the XGT Panel Software project should be saved in the one lower directory between those two directories.
3. If you touch [OK] button, the device is updated with XGT Panel Software in the designated path.
Notice
(1) Do not remove USB storage equipment or turn off the device during operation. It may cause abnormal installation of
project data.
(2) Do not remove or move the directory except CF or USB storage equipment. It may cause abnormal operation.
Chapter 8. XGT Panel S/W Update
8-1 |
Chapter 8 XGT Panel S/W Update
8.1 General Introduction
It describes the function for updating the XGT Panel software.
New function is added to XGT software, you need to update a version of XGT Panel
Please refer to the following.
[Method]
Select [Upgrade -> Update XGT Panel] on the XGT Panel’s main screen. Then XGT Panel becomes update mode. In order
to return to the main screen, touch a screen for 3 seconds.
After downloading XGT Panel software from LSIS website, make a temporary folder and save it.
Designate the folder where the software will be saved in the XP-Builder’s [XGT Panel Update] windows and update XGT
Panel by [Send] menu. For more detailed information about XP-Builder, please refer to the XP-Builder user manual.
Remark
Do not remove communication cable or turn off the device during updating. It may cause the malfunction.
Chapter 9. File Backup through External Storage Equipment
9-1 |
Chapter 9 File Backup through External Storage Equipment
Describes on management function about external storage equipment saving backup data of logging, recipe, and screen image
(1) XGT Panel can back up the logging, recipe, and screen image data at CF card or USB storage equipment according to setting
in XP-Builder.
(2) In case there is no space for backup in the designated storage equipment, it continues backup deleting previous data or stops
backup according to setting in XP-Builder
(3) Monitors attachment status of backup equipment at XP-Builder.
9.1 Path Structure in case of File Backup
Backup path structure of logging, recipe, and screen image is as follows.
Logging
YYYY.MM.BeginDay.EndDay.0
DD.BeginHour.EndHour.0 (space for one folder is full)
HH.BeginMinute.FF
Lhhmmss0.CSV
Recipe
Rhhmmss0.CSV (same as lower structure of each logging number)
DD.BeginHour.EndHour.1
DD.BeginHour. FF (There is free space for one folder)
1 (Logging Number)
2 (same as lower structure 1)
ScreenImage
Shhmmss0.BMP (same as lower structure of each logging number)
Root directory of CF or USB storage equipment
1. Path structure in case of logging backup
(1) Directory named ‘Logging’ is created under the root directory of USB/CF storage equipment
(2) The directory whose name is logging number is created under Logging directory.
(3) The directory whose name is year, month is created under Logging number directory.
(a) Includes day directory under
(b) Up to 500 day directories can be created.
(There is free space for one folder)
Chapter 9. File Backup through External Storage Equipment
9-2 |
(c) Name of year, month directory includes the firstly created day information under its directory
Ex) In case directory is created in 2010, October and includes directory since 15thunder, directory’s name is
: 2010.10.15.FF
FF at end means the directory can save more data created in 2010, October (currently, the number of lower directory
is 500 or less)
(d) In case month is changed, changes directory name to day information of last created day directory.
Ex) In case month becomes November from October and directory from 15th directory to 30th have been created in 2010,
October directory.
: 2010.10.15.30.0
(e) Though month is not changed, in case the number of day directory under year, month directory is 500 or above, directory
name is changed into name including day information of last created day directory.
Ex) In case the number of directory from first to 15th is 500 or above in the directory created in 2010, October.
: 2010.10.01.15.0
(f) In case there is the year, month directory having same start day and end day when changing directory’s name due to over
500 day directories or change of month, last digit index number increases.
Ex) In case there are three year, month directories that are having over 500 day directories created in October first and
2010 year October directory
: 2010.10.01.01.0
: 2010.10.01.01.1
: 2010.10.01.01.2
(4) Day directory is created under year, month directory
(a) Hour directory is created under day directory
(b) Day directory can have up to 500 hour directory
(c) Name of day directory includes not day information but also hour information of first created hour directory
(d) Relation between day directory and hour directory is same as relation between year month directoryand day directory.
(5) Directory whose name includes hour information is created under day directory.
(a) Hour directory includes backup file under
(b) Hour directory can include up to 500 backup file
(c) Name of time directory include not only hour information but also minute information of first created file under
(d) Relation between hour directory and backup file is same as relation between year, month directoryand day directory.
(6) Name of logging backup file includes the created hour, minute, second information.
(a) Backup file is created in CSV format.
(b) File name start with ‘L’ meaning logging and includes hour, minute, second, index information
(c) In case backup file is created at the same time in terms of second, index information at the end of file name increases.
2. Path structure in case of recipe backup
(1) Directory named ‘Recipe’ is created under USB/CF storage equipment root directory.
(2) Year, month directory is created under Recipe directory
(3) The lower directory structure is same as that of logging backup path structure.
(4) Name of recipe backup file includes the created hour, minute, second information.
(a) Backup file is created in CSV format.
(b) File name start with ‘R’ indicating recipe and includes hour, minute, second, index information.
(c) In case backup file is created at the same time in terms of second, index information at the end of file name increases.
3. Path structure in case of screen backup
(1) Directory named ‘Screen Image’ is created under USB/CF storage equipment root directory.
(2) Directory whose name is year; month is created under Screen Image directory.
Chapter 9. File Backup through External Storage Equipment
9-3 |
(3) The lower directory structure is same as that of logging.
(4) Name of screen image backup file includes hour,minute, second information.
(a) Backup file is created in bitmap format.
(b) File name starts with ‘S’ and includes hour, minute, second, index information.
(c) In case backup file is created at the same time in terms of second, index information at the end of file name increases.
Remark
(1) When changing device time, in case of changingcurrent time into after time, we guarantee the normal operation. But in
case of changing current time into early time, we don’t guarantee the normal operation. In this case, you have to delete
directory including the changed hour and its lower directory for normal operation. For example, if you change time from
December 10th to December 5th, you have to delete year, month directory created in December 10th and restart the device
(2) Sorting by project is not supported for each logging, recipe, screen image. For example, there are no.1, 2, and 3 logging
groups in the project A. And in case each logging group backups the file, 1, 2, 3 directories are created and each data is
saved under each directory. Then, in case file backup occurs in the project B having no.1, 2 logging group, backup file is
created in same directory of project A. In this case, you have to sort the backup files of project A and B based on the
created time.
9.2 Operation setting when there is no Space for Backup
You can designate in the XP-Builder whether to cancel the backup or delete the oldest backup file and execute backup when
there is no space in the storage equipment.
[Project Property Setting -> Storage Settings -> Backup Storage -> Delete old file if disk full]
1. In case of backup, deleting the oldest data
(1) In case there is no space for backup, searches the oldest year, month directory under Logging, Recipe, Screen Image. (But
in case of Logging, finds under Logging number directory. That is, when executing backup about Logging number 2, in
case there is no backup data in Logging number 2 directory and there is data only in logging number 1, data of logging
number 1 is not searched/deleted.)
(2) Searches the oldest day directory under the oldest year, month directory.
(3) Searches the oldest hour directory under the oldest day directory.
(4) Deletes the oldest backup file under the oldest hour directory
(5) Checks the space and if more space is necessary, the above steps of (1) ~ (4) are repeated and checks the space.
(6) When deleting file, in case all data in time directory are deleted, relevant hour directory is deleted.
(7) When deleting hour directory, in case all hour directories in day directory are deleted, relevanthour directory is deleted.
(8) When deleting day directory, in case all day directories in year, month directory are deleted, relevant year, month directory is
deleted.
Remark
(1) In unknown directory or file (user file or directory), searches the oldest thing among normal backup files except unknown
directory or file.
(2) In case there is nothing except user data in now searched directory, backup operation fails. XGT Panel can’t delete user
data, at this point, operation stops.
Chapter 9. File Backup through External Storage Equipment
9-4 |
9.3 Monitoring Connection Status of External Storage Equipment
XGT Panels monitors connection status about external storage equipment designated when setting backup path in XP-Builder.
The following figure is backup path specified in XP-Builder.
In order to use this monitoring function, you have to set about system alarm window
Chapter 9. File Backup through External Storage Equipment
9-5 |
In case USB storage equipment (or CF storage equipment) is removed during operation after setting the path for saving Logging
backup file as USB storage equipment (or CF storage equipment) and downloading the project into device, the designated system
alarm (HS951.0) is set. In case storage equipment is equipped again, alarm is reset.
In case USB storage equipment (or CF storage equipment) is removed during operation after setting the path for saving Recipe
backup file as USB storage equipment (or CF storage equipment) and downloading the project into device, the designated system
alarm (HS951.1) is set. In case storage equipment is equipped again, alarm is reset.
In case USB storage equipment (or CF storage equipment) is removed during operation after setting the path for saving Screen
Image backup file as USB storage equipment (or CF storage equipment) and downloading the project into device, the designated
system alarm (HS951.2) is set. In case storage equipment is equipped again, alarm is reset.
Internal address of the designated system alarm can be checked in XP-Builder as follows.
Chapter 10. Installation and Wiring
10-1 |
Chapter 10 Installation and Wiring
10.1 Installation
10.1.1 Installation environment
This machine has high reliability regardless environment. But for reliability and stability, be careful the followings
(1) Environment condition
(a) Install at the panel which can protect this machine from water and dust.
XGT Panel is designed by IP65 Standard in front parts and IP20 Standard in rear parts.
(b) Install at the place where impact and vibration is not continuously applied.
XGT Panel is designed to meet IEC standard (IEC 61131-2).
(c) Do not expose this machine to direct light.
(d) Do not install at the place where rapid temperature change can occur.
Moisture by rapid temperature change can cause malfunction and damage.
(e) This machine should be installed within 0 ~ 50°C, otherwise the screen may be changed or cause malfunction
(f) This machine should be installed within 10~85% relative-humidity.
Moisture by rapid temperature change can cause malfunction and damage.
(g) Avoid corrosive gas and burnable gas.
(2) Installation construction
(a) When doing screw’s processing or wiring construction, be careful that the remains do not enter the XGT Panel inside.
(b) Install at the place where you can easily control.
(c) Do not install with high voltage machine within same Panel.
(d) Keep distance of more than 100mm from duct for wiring and peripheral machine.
(e) Ground at the place where few noises develop.
(3) Anti-heat design of control panel
(a) In case of installing XGT Panel in the airtight panel, consider the heat by other machine as well as own heat. In case that
the air circulates through a ventilating opening or a general pan, XGT Panel system can be influenced by in-draft of dust
or gas.
(b) We recommend you to install a filter or to use an airtight heat exchanger.
Remark |
Anti-water and anti-vibration standard ► IP standard is IEC 529 standard (international anti-water grade regulation) and it can be divided into protection grade against invasion of solid matter and protection grade against invasion of water. ►In the IP65 certification, it can be divided into protection against dust (6) and water jets from all sides (5). ►IP20 is about protection against solid matter (2) whose diameter is more than 12mm and IP2 doesn’t have protection about water (0) |
10.1.2 Notice in handling
It describes the notice from opening to installation.
• Do not drop or cause heavy impact.
• Do not disassemble voluntarily. When doing this, we are not responsible for the product.
•When wiring, be careful that the remains do not enter into XGT Panel.
Chapter 10. Installation and Wiring
10-2 |
10.1.3 Notice in installing the panel
Here describes how to install XGT Panel in panel and notice.
(1) Panel cut
• Before installing the XGT Panel in panel, panel should be made with the following dimension.
Classification | X (Wide) | Y (Height) | Z (Thickness) | ||
XP30-BTE XP30-TTE XP30-BTA XP30-TTA |
156.0 | +1 | 123.5 | +1 | 1.6~9.5 |
-0 | -0 | ||||
XP40-TTA XP40-TTE |
192 | +1 | 138 | +1 | |
-0 | -0 | ||||
XP50-TTA XP50-TTE |
228.5 | +1 | 158.5 | +1 | |
-0 | -0 | ||||
XP70-TTA | 294.5 | +1 | 227.5 | +1 | |
-0 | -0 | ||||
XP80-TTA | 294.5 | +1 | 227.5 | +1 | |
-0 | -0 | ||||
XP90-TTA | 383.5 | +1 | 282.5 | +1 | |
-0 | -0 |
X
Y
Z
Unit: [mm]
Chapter 10. Installation and Wiring
10-3 |
(2) XGT Panel installation
• Keep the distance of 100 mm between XGT Panel and panel per each direction.
Remark
(1) To be affected at a minimum by the electromagnetic waves (radial noise) or heat from other controllers, it needs to keep its
distance as the above explanation.
(2) When installing, consider the power and communication cable wiring.
•When fixing the product to panel, use the anti-vibration rubber packing.
The anti-vibration rubber packing is equipped at the XGT Panel basically.
Unit: [mm]
100100 |
100100
100100
100100
100100
Anti-vibration
rubber packing
Chapter 10. Installation and Wiring
10-4 |
Remark
Because the product can be affected by dust, use the anti-vibration rubber packing.
(3) Installation location
•When installing the XGT Panel, consider screen and use of touch.
•When you don’t see within the following angle, you may not see clearly. When installing, consider angle.
Item | Angle (left and right) | Upper | Lower |
XP30-BTE | 45 deg. | 40 deg. | 20 deg. |
XP30-TTE | 80 deg. | 70 deg. | 70 deg. |
XP30-BTA | 45 deg. | 40 deg. | 20 deg. |
XP30-TTA | 80 deg. | 70 deg. | 70 deg. |
XP40-TTA(TTE) | 65 deg. | 50 deg. | 60 deg. |
XP50-TTE | 45 deg. | 20 deg. | 20 deg. |
XP50-TTA | 65 deg. | 50 deg. | 60 deg. |
XP70-TTA | 65 deg. | 45 deg. | 65 deg. |
XP80-TTA | 65 deg. | 45 deg. | 75 deg. |
XP90-TTA | 75 deg. | 50 deg. | 60 deg. |
Remark
1) Because XP30-BTA (BTE) uses STN Mono LCD, it has poorer clearness and expression angle.
2) XP30-BTA (BTE) can adjust Contrast. Adjust Contrast according to environment.
Chapter 10. Installation and Wiring
10-5 |
(4) Fixation
• Fix the XGT by using the bracket as follows. (The bracket is included in the product.)
Remark
Please remove a protective film attached to the screen when launching a product. Modification of the protective film can
cause the touch malfunction or error in input. It is recommended to use a protection sheet to protect the screen. Please
inquire for purchasing a protection sheet to the near dealerships or special agent.
(1) Protection Sheet for XP30: XPO-PS30
(2) Protection Sheet for XP40: XPO-PS40
(3) Protection Sheet for XP50: XPO-PS50
(4) Protection Sheet for XP70/80: XPO-PS70
(5) Protection Sheet for XP90: XPO-PS90
Fix through bracket
Fix through bracket
Panel
Fix through
Bracket
Fix through bracket
Chapter 10. Installation and Wiring
10-6 |
10.2 Wiring
It describes the wiring that you should know when installing the XGT Panel.
10.2.1 Power wiring
XGT Panel is divided into the DC product and the AC product.
Power | Name |
DC 24V | XP30-BTA(BTE)/DC XP30-TTA(TTE)/DC XP40-TTA(TTE)/DC XP50-TTA(TTE)/DC XP70-TTA/DC XP80-TTA/DC |
DC 12~24V | XP30-BTA/D1 XP50-TTA/D1 |
AC 100~240V | XP70-TTA/AC XP80-TTA/AC XP90-TTA/AC |
► If AC power is applied into the product for DC power, It may cause damage or fire.
Be careful of connection.
► ‘/DC’ is the product which use DC 24V, ‘/D1’ is the product which use DC 12~24V, and ‘/AC’ is the product
which use AC 100~240V. When using the product, Please check the label in the back of the product.
Warning
Chapter 10. Installation and Wiring
10-7 |
The power terminal should have the following specification.
The power cable should have the following specification.
Type | Cable specification (Unit: ㎟) |
Power and protection ground | 1.5 (AWG16) ~ 2.5 (AWG12) |
Remark
(1) Because of voltage down, we recommend the thick stranded cable (more than 2 ㎟).
(2) If possible, use the stranded cable and connect with minimum length.
(3) To easily classify the cable, use the different color’s cable respectively.
Wiring of power is as follows.
Less than
6.00mm
Less than
6.00mm
Ø3.2 Ø3.2
DC Power connection
Ground
Chapter 10. Installation and Wiring
10-8 |
Remark
(1) When the regulation of power is bigger than provision, use the constant voltage transformer.
(2) In case power has much noise, use the insulation transformer.
Separate the XGT Panel power from the I/O device and main circuit device.
Remark
(1) Separate the XGT Panel’s power from the main circuit (high voltage, large current) cable, I/O signal cable.
If possible, install with a interval of more than 100mm.
AC 100~240V 전원 입력
AC power connection
Main Power
XGT Panel power
I/O power
Main circuit power
I/O device
Main circuit device
Constant
Voltage
Transformer
100~220 V AC Power Ground
Chapter 10. Installation and Wiring
10-9 |
Against the surge and lighting, use the surge absorber as follows.
Remark
(1) Separate the surge absorber’s ground (E1) from XGT Panel’s ground (E2).
(2) Select a surge absorber so as not to exceed the maximum permissible voltage of a surge absorber even if power
voltage rises to maximum
When noise invades, use the insulation shield Trans or noise filter.
Strand input power cable with minimum length and make sure the shield Trans or noise filter is not crossed above the duct.
It is recommended to attach a ferrite core in power section when using Magnet Switches.
ex) Attach ferrite core on power section as shown in the illustration.
E2 |
XGT Panel |
E1 |
Surge absorber to prevent the lighting
Ferrite core
(CU1330B, E-TECH)
(CU1330G, E-TECH)
(ZCAT3035-1330, TDK)
Chapter 10. Installation and Wiring
10-10 |
10.2.2 Ground wiring
(1) Our XGT Panel has enough anti-noise measure, so except that there are many noises specially, the ground is
not needed. When doing ground, please refer to the followings.
(2) The ground should be the exclusive ground.
The ground should be type 3 ground (ground resistor is less than 100Ω).
(3) When not doing the exclusive ground, do common ground like figure B).
A) Exclusive ground: Best B) Common ground: Good C) Common ground: Poor
(4) Use the cable more than 2 mm2. Put the point of the ground near the XGT Panel and shorten the ground line.
Remark
(1) If the ground status is poor or connected like C), it may cause malfunction or fault of communication.
Make sure that the ground status is good.
XGT Panel |
The other devices |
XGT Panel |
XGT Panel |
The other devices |
The other devices |
Type 3 ground Type 3 ground
Chapter 11. Maintenance
11-1 |
Chapter 11 Maintenance
To keep the XGT Panel best, examine the XGT Panel.
11.1 Maintenance
Because an error may be developed by environment, the periodic maintenance is needed. You should check the following
categories once or twice every 6 months.
Maintenance category | Judgment standard | Measure | |
Power | Within the power change range (Within -15% / +10%) |
Modify the source of electric power in order to be in the fluctuation range of a permissible voltage. |
|
Environment | Operating temperature |
0 ~ + 50℃ | Modify the operating temperature and humidity to beproper. |
Operating humidity |
10 ~ 85%RH | ||
Vibration | No vibration | Use the anti-vibration rubber and make a count measure. | |
Getting loose of power terminal | There is no unwinding | Screw the unwound terminal. | |
Getting loose of communication connector |
There is no unwinding | Screw the unwound terminal. | |
Reserved part | Amount of reserved part and reservation Check the status |
Refill the insufficiency and improve the reservation. |
11.2 Daily Maintenance
Check the followings daily.
Maintenance category | Maintenance contents | Judgment standard | Measure |
Status of panel adhesion | Check the unwound screw ofthe bracket | Fixed firmly | Wind the screw |
Getting loose of power terminal | Getting loose of power terminal screw | There is no unwinding | Wind the screw |
Reduce the distance between compressed terminals. |
Keep the proper distance. | Correction | |
Status of communication connector |
Unwinding of fixed screw | There is no unwinding | Windthe screw |
Indication LED | Check the lighting | Green LED shouldbe turned on | Refer to the appendix 1. |
Chapter 11. Maintenance
11-2 |
11.3 Periodical Maintenance
Check the followings once or twice every six months and take measure.
Maintenance category | Maintenance method | Judgment standard | Measure | |
Environment | Surrounding temperature |
Measure through temperature/Hygrometer Measure of corrosive gas |
0 ~ 50°C | Modify it to meet the general standard. (environment standard in the panel) |
Surrounding humidity | 10 ~ 85%RH | |||
Surrounding pollution degree |
There is no corrosive gas. | |||
XGT Panel Status |
Unwinding, swing | Shake the XGT Panel | Fixed firmly | Wind the screw |
Dust, foreign matter adhesion |
Check by eye | There is no adhesion | - | |
Connection status |
Unwinding of screw | Wind the screw by driver | There is no unwinding. | Wind the screw |
Reduce the distance between compressed terminals. |
Check by eye | Keep the proper distance. | Correction | |
Unwinding of connector | Check by eye | There is no unwinding. | Wind the fixed screw of connector |
|
Power voltage maintenance | Check the power voltage of input terminal of power by test |
AC100~240V: AC85~ 264V DC24V: DC19.2 ~ 28.8V |
Supply power modification | |
Battery | Check when battery is exchanged and voltage drop is indicated (It is expressed by system alarm) |
• Check the total of power stoppage time and guarantee duration • There is no battery voltage drop indication |
If guarantee duration is exceeded even tough there is no battery voltage drop indication, change the battery. |
|
LCD Backlight maintenance | Checking by eye | Check theguarantee duration | When error occurs, change the backlight. |
|
Touch status |
Touch location error | Check at the Diagnostics of XGT Panel |
Appropriate touch location | Reset at the setting of XGT Panel. |
Touch pad malfunction | Checking by eye | There is no damage or scratch/pollution |
When error occurs, change touch pad. |
Chapter 11. Maintenance
11-3 |
Remark
(1) Battery exchange time is expressed by alarm. System alarm is expressed when system alarm category is set at the XP-Builder
as follows.
(2) LCD backlight’s exchange is available for only XP50-TTA, XP70-TTA, XP80-TTA, XP90-TTA. In case of XP30-BTE, XP30-
BTA, XP30-TTA, you have to exchange the LCD when error occurs or product life is finished because LCD and backlight is one
product.
Chapter 12. EMC Standard Certification
12-1 |
Chapter 12 EMC Standard Certification
12.1 Requirement for EMC Standard Certification
EMC command is regulated on “It doesn’t produce the Strong electromagnetic waves: Emission” and “It is not affected by
electromagnetic wave from external: Immunity”. The following is describing the contents to meet the EMC command when configuring
the system by using the XGT Panel. This is a summary document for the request and standard which our company has obtained
from EMC but we don't assure that all devices manufactured according to these contents are not suitable for the below standards. The
final manufacturer needs to finally judge about the fitness method or fitness judgment of EMC command.
12.1.1 CE standard certification
Applied Standards | Results | |
1. Emission | ||
Conducted Disturbance | EN61000-6-4:2007 | C |
Radiated Disturbance | EN61000-6-4:2007 | C |
Harmonic Current Emission | EN61000-3-2:2006 / A2 : 2009 | NA 주2) NT 주3) |
Voltage Change, Fluctuations and Flicker | EN61000-3-3:2008 | NA 주2) NT 주3) |
2. Immunity | ||
Electrostatic Discharge | EN61000-6-2:2005 | C |
EN61000-4-2:2009 | ||
Radio-Frequency Electromagnetic Field | EN61000-6-2:2005 | C |
EN61000-4-3:2006 / A1 : 2008 | ||
Fast Transient | EN61000-6-2:2005 | C |
EN61000-4-4:2004 | ||
Radio-Frequency Continuous Conducted | EN61000-6-2:2005 | C |
EN61000-4-6:2009 | ||
Power-Frequency Magnetic Fields | EN61000-6-2:2005 | C |
EN61000-4-8:1993 / A1 : 2001 | ||
Surges | EN61000-6-2:2005 | C |
EN61000-4-5:2006 | ||
Voltage Dips and Interruptions | EN61000-6-2:2005 | NA 주2) C 주3) |
EN61000-4-11:2004 | ||
RE1) C=Conform NC=Not Conform NT=Not Tested NA=Not Applicable RE2) Applicable to the only XP30-BTA(BTE)/DC, XP30-TTA(TTE)/DC, XP50-TTA(TTE)/DC, XP70-TTA/DC, XP80-TTA/DC XP40-TTA(TTE) RE3) Applicable to the only XP70-TTA/AC, XP80-TTA/AC, XP90-TTA/AC |
Chapter 12. EMC Standard Certification
12-2 |
Directive:
Electromagnetic Compatibility Directive 89/336/EEC amended by the Directive 93/68/EEC
12.1.2 KC standard certification
The XGT Panel acquire the electromagnetic fitness registration (KC specification) certified by wave laboratory under informationcommunication part.
A grade device
This device acquires KC for business. Be careful that.
If device is not purchased properly, exchange it to device for home.
12.2 Requirement for Low Voltage Command Suitability
It is required to get the needed Stability for the device operated at AC50~1000V, DC75~1500V’s power. The following describes
attention about installation and wiring for the suitability when using the XGT Panel. Though the following data is made by requirement
of regulation and standard, we don’t guarantee that all devices are suitable for the above command. The method to be suitable for the
EMC command and judgment of suitability should be finally made by device manufacturer himself.
12.2.1 Standard certification for XGT Panel
XGT Panel is according to the EN6100-1 (stability of device used in the measure, control laboratory).
XP70-TTA/AC, XP80-TTA/AC, XP90-TTA/AC among the XGT Panel is made to meet the above standard.
12.2.2 Selection of XGT Panel
(1) XP70-TTA/AC, XP80-TTA/AC, XP90-TTA/AC
Because the Power module whose rated input voltage is AC110/220V has danger voltage (voltage of more than 42.4V),
the product which is suitable for CE mark is having the improved insulation between internal 1 and 2.
(2) XP30-BTA(BTE)/DC, XP30-BTA/D1, XP30-TTA (TTE)/DC, XP50-TTA (TTE)/DC, XP50-TTA/D1,
XP40-TTA(TTE)/DC, XP70-TTA/DC, XP80-TTA/DC
The I/O module under DC24V exceeds the range of low voltage command target.
Appendix 1. Troubleshooting
App.1-1 |
Appendix 1 Troubleshooting
1.1.Type of Problem
It classifies problems from XGT Panel including an indicated figure, indication of the object, and problems appeared when
downloading. Refer to the following chart.
Classification of problem | Description |
Problem when starting | Malfunction when starting. ☞Please refer to the 2. Problem when starting. |
Problem when touching | In case that there is no reaction when touching. ☞Please refer to the 3. Reaction problem when touching. |
Display problem of figure and object. |
In case that the figure or object is different from when editing. ☞Please refer to the 4. Indication problem of figure and object. |
Communication problem | In case that communication is not executed properly. ☞Please refer to the 5. Communication problem. |
Error message when executing program |
In case that an error message occurs when operating the XGT Panel. ☞Please refer to the 6. Error message when executing program. |
2.2.Problem when Starting
Why does black screen show up when turning on the device?
Phenomenon: When turning on the device, black screen shows up and the booting is impossible.
<Reason>
1) Because the device is not set as a booting mode.
2) Black screen may appear because of malfunction of backlight.
<Solution>
1) Because the device is not set as a booting mode, the above problem can occur. Check whether the number 2
switch at DIP switch in the back of the device is in A direction or not.
When is LED color changed?
Check the followings.
Display color | Contents |
RED | Communication time-out or system alarm which is registered as a system alarm at the builder occurs in the HMI. (It is not recovered) |
GREEN | OS booting status, HMI’s monitoring status, HMI’s not monitoring status. (including image data, diagnosis, setting , and engine update) |
Appendix 1. Troubleshooting
App.1-2 |
3. Reaction Problem when Touching
When touching the screen it reacts in a different area or it may not react at all?
Phenomenon: When touching the screen it reacts in a different area or it may not react at all.
<Reason>
1) Touch’s Calibration setting is not proper.
2) Touch panel may be a break down.
<Solution>
1) Redo Calibration setting about touch. Refer to the [Device manual Ch.4.1 Touch Calibration].
2) It you can’t go to setting menu, connect mouse to USB port and use mouse.
Buzzer does not sound.
Phenomenon: When pressing buzzer, buzzer does not sound.
<Reason>
1) When that the switch operates but the buzzer doesn’t sound, the buzzer is set as no sound.
2) If the switch doesn’t work too, it seems that some error occurs in the touch function.
<Solution>
1) Redo environment setting for buzzer to sound. Refer to the [device manual Ch.4.7 Environment Setting].
2) After setting to use buzzer, check whether the buzzer sounds or not in the 1)’s setting windows.
Appendix 1. Troubleshooting
App.1-3 |
4. Display Problem of Figure and Object
The shape of object is not shown or the number or character value which has to be shown is not shown.
Phenomenon: The shape of object is not shown or the number or character value which has to be shown is not shown.
<Reason>
The connection with PLC connected with each project is disconnected or NAK occurs.
<Solution>
1) When the communication is executed at first, Check the cable connected with PLC is OK or not.
2) If object where the offset is set is not shown, check whether address range is exceeded or not.
3) In case that communication is not OK, when communication is abnormal, the following message shows up in the
XGT Panel.
Object type | Phenomenon |
Bit Switch | The switch is expressed but it doesn’t work. |
Word Switch | The switch is expressed but it doesn’t work. |
Change Screen Switch | The switch is expressed but it doesn’t work. |
Special Switch | The switch is expressed but it doesn’t work. |
Multi Switch | The switch is expressed but it doesn’t work. |
Bit Lamp | Image is not shown. |
Word Lamp | Image is not shown. |
N-State Lamp | Image is not shown. |
Clock | Present time is shown. |
Bit Message | Message is not shown. When designating the background image, image is shown as it is. |
Word Message | Message is not shown. When designating the background image, image is shown as it is. |
Numeric Display | The value is not shown. When designating the background image, image is shown as it is. |
Numeric input | The value is not shown. When designating the background image, image is shown as it is. |
Text Display | Character string is not shown. When designating the background image, image is shown as it is. |
Text Input | Character string is not shown. When designating the background image, image is shown as it is. |
Bit Window | The window screen set in the object is not shown. But if communication is set with other object in the same window screen, it can be shown by that object. |
Word Window | The window screen set in the object is not shown. But if communication is set with other object in the same window screen, it can be shown by that object. |
Bit Part | The part screen set in the object is not shown. But if communication is set with other object in the same part screen, it can be shown by that object. |
Word Part | The part screen set in the object is not shown. But if communication is set with other object in the same part screen, it can be shown by that object. |
Animation | Animation is not shown. |
Bar Graph | Graph is not shown. When designating the background image, image is shown as it is. |
Pie Graph | Graph is not shown. When designating the background image, image is shown as it is. |
Meter Graph | Graph is not shown. When designating the background image, image is shown as it is. |
Closed Graph | Graph is not shown. When designating the background image, image is shown as it is. |
Trend Graph | X, Y axis is shown normally but trend axis is not normally shown. When designating the background image, image is shown as it is. |
Appendix 1. Troubleshooting
App.1-4 |
Object type | Phenomenon |
History Alarm Viewer | Change doesn’t occur. When communication is abnormal, alarm occurs because it can’t know the status of alarm target device. But previous alarm data shows up as it is. |
Data list | Value is not shown. Lattice of viewing data list of object is shown as it is. |
Logging Viewer | Change doesn’t occur. When communication is normal, the recorded log data is shown normally. But, log data is shown as # when communication is abnormal. |
Navigator | Change doesn’t occur. Because it shows the group of alarm already developed, though communication is abnormal, if it has alarm data already developed, it shows the name of group where each alarm is included. |
The number indication object value is shown as # or ~.
Phenomenon: The number indication object value is shown as # or ~.
(Same phenomenon occurs at the number input device, viewing data list, and viewing logging)
<Reason>
1) This happens when digit is not correct or type is not BCD.
<Solution>
1) When the number to be expressed exceeds the number set in the object, # is expressed. In case of this, set the
digit largely and after download again, execute program again.
2) When the numeric display object is expressed as BCD type, the data whose type is not BCD is expressed as ~. In
case of this, adjust device value as BCD type.
3) This phenomenon occurs at the data list object, numeric input, numeric display device, and logging viewer.
After switching the screen, the previous screen remains for a few minute.
Phenomenon: After switching the screen, when there is no background or image in the part or number indication device,
the previous screen remains for a few minute because of change of part.
<Reason>
After switching the screen, when connection is set up multiply or communication time-out occurs, the screen of
previous part remains in some object.
<Solution>
1) It’s normal status. In case that multiple connection or communication is not good, when switching the screen, the
remains of previous screen can occur during the time-out hour.
The folded object doesn’t sequentially show up.
Phenomenon: The number under the data list shows up above data list.
<Reason>
1) The device value is expressed at the top of object screen.
<Solution>
1) It’s normal status. The folded window or part object is not included in screen, regardless of sequence of drawing,
the object changed recently is expressed at top of screen. So if possible, do not fold the object in screen.
Appendix 1. Troubleshooting
App.1-5 |
The object always shows up above the figure.
Phenomenon: I downloaded the figure above the object in XP-Builder, but the object always shows up above the figure.
<Reason>
1) In XGT Panel, The object always shows up above the figure.
<Solution>
1) It’s normal status. The object always shows up above figure in the XGT Panel.
5. Communication Problem
It seems that communication does not work.
Phenomenon: On the screen where the object is not many, communication works but when you move the screen where
the object is many, timeout occurs.
<Reason>
1) In the device setting, the communication time-out is set to be too short.
<Solution>
1) It occurs because timeout is set much smaller than sum of request time of communication data and response
time from PLC. In the device setting at the XP-Builder, after setting communication time out to be big, download
program and execute again.
It seems that communication doesn’t work.
Phenomenon: Communication doesn’t work.
<Reason>
1) Communication setting or cable may be not normal.
<Solution>
1) In case of RS-232C, check whether connection setting is normal or not in XP-Builder.
2) In case of RS-422/485, check whether station and communication connection setting is normal or not.
3) If 1), 2) is normal, do diagnosis about PLC-RS232C, PLC-RS485/422 at the Serial diagnosis screen of device
menu.
Refer to the [Device manual ch.5.6 Serial Communication Diagnosis]
4) If 3) is normal, check whether connection cable has error or not.
5) In case of Ethernet, check the port and IP setting about relative PLC.
Appendix 1. Troubleshooting
App.1-6 |
6. CF/USB Removal of Memory Card
When removing the CF/USB memory card, device is stopped for some times.
Phenomenon: This happens when doing data backup including logging, recipe.
<Reason>
1) This happens because memory card is removed when doing data backup.
<Solution>
1) If possible, when monitoring XGT Panel, do not remove the memory card and after going out to the waiting screen,
execute the removing.
2) Inescapably you have to remove it during the operation, remove when backup does not occur. If the above
phenomenon occurs, it works normally after about 10 seconds.
Appendix 1. Troubleshooting
App.1-7 |
7. Error Message during Execution of Program
In case that problems occur during execution of XGT Panel including the start of device, diagnosis of device and environment
setting, project download, monitoring of control device, and error messages occur as type of box. At this time the message
indicates the code made by 4 digit number. The front 2 number indicate code of object and work, the rear 2 number is
message number. In case that the present error message is indicated as [0101], an error message occurs when doing
diagnosis about the status of NVRAM. When an error message occurs, refer to the row’s number and sequence and find the
category of reason and measure.
Object | Error code | Occurrence location |
Error message | Reason and measure | |
Type | Address | ||||
Device diagnosis |
0x01 | 0x01 | XGT Panel | NVRAM Data Access ... FAILED! |
Failed to check whether backup memory is normal or not. If this symptom is repeated, contact the near Customer Service Center. |
0x02 | XGT Panel | BATTERY STATUS ... NOT GOOD! |
Backup data is not valid. If this symptom is repeated when turning power off and on, remove XGT Panel’s power and exchange the battery. |
||
0x03 | XGT Panel | Write Operation FAILURE! |
The built-in Flash disk has an error. Contact the near Customer Service Center. |
||
0x04 | XGT Panel | Read Disk Information Error! |
The built-in Flash disk has an error. Contact the near Customer Service Center. |
||
0x05 | XGT Panel | Write Operation FAILURE! |
Check that CF card is empty, and equip CF card and test again. If same symptom is repeated, CF card or CF card slot of XGT Panel may have a problem. |
||
0x06 | XGT Panel | Read Disk Information Error! |
Check that CF card is empty, and equip CF card and test again. If same symptom is repeated, CF card or CF card slot of XGT Panel may have a problem. |
||
Device setting | 0x02 | 0x01 | XGT Panel | Invalid timeout value. | You inputted the wrong time which is not within backlight setting time range. Input the effective time. |
0x02 | XGT Panel | Not found XGT Panel configuration file. |
There is no setting information data of XGT Panel. If this symptom is repeated when turning power off and on, contact the near Customer Service Center. |
||
0x03 | XGT Panel | Please enter an integer between 0 and 255. |
When setting IP, the values within 0~255 are effective. Input the value within the above range. |
||
Viewing device information |
0x03 | 0x01 | XGT Panel | No project in XGT Panel. | Now, there is no downloaded project so you can’t see connection information. Download the project from XP-Builder. |
XGT Panel Update |
0x04 | 0x01 | XGT Panel | Failed to Start engine. Please update engine again. |
Because of update error or Flash disk error, program can’t be executed. If you can update, redo the above procedure. If you can’t, |
Appendix 1. Troubleshooting
App.1-8 |
Object | Error code | Occurrence location |
Error message | Reason and measure | |
Type | Address | ||||
contact the near Customer Service Center. | |||||
Switch | h05 | h01 | XGT Panel | Invalid password. | There is password in the each object. When editing the project downloaded in the present device, input the designated password at the project property information. |
Number indication device/ Number input device |
0x06 | h01 | XGT Panel | Can't write Data. | Because of communication error, the value can’t be inputted. Check the communication status and input again. |
h02 | XGT Panel | No input Data. | You tried to input with no value. Input the value |
||
0x03 | XGT Panel | Exceeded the max length. |
You exceed the maximum length to input. | ||
0x04 | XGT Panel | Exceeded the minimum Value. |
You exceed the maximum value to input. | ||
0x05 | XGT Panel | Exceeded the maximum Value. |
You exceed the minimum value to input. | ||
0x06 | XGT Panel | Invalid at Input Case. | When you input the value, input can’t be done because of wrong input. Check the input condition of each object in the Builder and input again. |
||
Lamp | 0x07 | None | |||
Character indication device/ Character input device |
0x08 | None | |||
Message | 0x09 | None | |||
Clock | 0x0A | None | |||
Animation | 0x0B | None | |||
Graph | 0x0C | None | |||
Window | 0x0D | None | |||
Part | 0x0E | None | |||
History alarm | 0x0F | None | |||
Flow alarm | 0x20 | None | |||
System alarm | 0x21 | None | |||
Scheduler related |
0x22 | None | |||
Recipe related |
0x23 | None | |||
Logging related |
0x24 | None | |||
Data list | 0x25 | None | |||
Project download |
0x26 | 0x00 | XGT Panel | Abnormal send-payload. Please download project again. |
Communication status is abnormal. Check the connection of communication cable. |
Appendix 1. Troubleshooting
App.1-9 |
Object | Error code | Occurrence location |
Error message | Reason and measure |
Type | Address | |||
0x01 | XP Builder | There's not Password File. |
This message shows up when making it newly because there is no password setting file in the device. When making it newly, it is initialized with no password. |
|
0x02 | XP Builder | Failed to Create Password File. |
It make new password setting file when there is no password setting file. But downloading is stopped when it fails to make this file because of device error. If this problem is repeated, Contact the near Customer Service Center. |
|
0x03 | XP Builder | Invalid Backup Media. | Communication status is abnormal. Route information is not correct to save project data. If this problem is repeated, Contact the near Customer Service Center. |
|
0x04 | XP Builder | Failed to Create version File. |
In case that the version information file doesn’t exist in the device, that file is made newly. In case that the device has error and fails to make that file, download is stopped. If this problem is repeated, Contact the near Customer Service Center. |
|
0x05 | XP Builder | File Size Error. | There is version information file. In case that because of error of device, it fails to read version information, because the device doesn’t know version, download is stopped. If this problem is repeated, Contact the near Customer Service Center. |
|
0x06 | XP Builder | Failed to get Project ID. | In case of not reading file where project property is included, download is stopped. If this problem is repeated, Contact the near Customer Service Center. |
|
0x07 | XP Builder | Failed to read history alarm data. |
In case of not reading information about alarm history because of error of NVRAM, download is stopped. If this problem is repeated, Contact the near Customer Service Center. |
|
0x08 | XP Builder | Failed to read CF Card information. |
Project is set to store data at CF card equipped at device. By the way, now it can’t read information about CF card. Check the installation status of CF card and if it is normal, check the CF card. If this problem is repeated, contact Customer Service Center. |
Appendix 1. Troubleshooting
App.1-10 |
Object | Error code | Occurrence location |
Error message | Reason and measure | |
Type | Address | ||||
Project download |
0x26 | 0x09 | XP Builder | Failed to read USB information. |
Project is set to store data at USB storage device equipped at device. By the way, now it can’t read information about USB storage device. Check the installation status of USB storage device and if it is normal, check USB storage device. If this problem is repeated, contact Customer Service Center. |
0x0A | XP Builder | Failed to read Flash memory information. |
In case that it can’t know information about memory status, download is stopped. If this problem is repeated, contact Customer Service Center. |
||
0x0B | XP Builder | Failed to clear Temp Directory. |
In case that because of error of Flash Disk, it can’t delete the directory made temporally for download because of error of Flash Disk, download is stopped. If this problem is repeated, contact Customer Service Center. |
||
0x0C | XGT Panel | Failed to delete Font File. Please reboot XGT Panel. |
In case that it fail to delete the font file of previous project because of error of XGT Panel, download is stopped. If this problem is repeated, contact Customer Service Center. |
||
0x0D | XGT Panel | Failed to delete Image File. Please reboot XGT Panel. |
In case that it fail to delete the image file of previous project because of error of XGT Panel, download is stopped. If this problem is repeated, contact Customer Service Center. |
||
0x0E | XGT Panel | Failed to delete Sound File. Please reboot XGT Panel. |
In case that it fail to delete the sound file of previous project because of error of XGT Panel, download is stopped. If this problem is repeated, contact Customer Service Center. |
||
0x0F | XGT Panel | There's no downloaded project. It needs to download whole project |
It can’t download part or fixed part in case there is no downloaded project. In case of this, download again. If this problem is repeated, contact Customer Service Center. |
||
0x10 | XP Builder | Backup path is invalid. Please check the path that project is downloaded. |
When user change the storage location of project data including image and font, if there is not respective routine, it make newly. By the way, download is stopped in case it fails to make newly. When it is designated as CF card, it can occur in case CF card is not installed. If this problem is repeated and not referred in the above, contact Customer Service Center. |
Appendix 1. Troubleshooting
App.1-11 |
Object | Error code | Occurrence location |
Error message | Reason and measure | |
Type | Address | ||||
0x11 | XGT Panel | Failed to delete previous project archive. Please reboot XGT Panel. |
The project backup file downloaded already can be deleted because of error of XGT Panel. Reboot XGT Panel. If this problem is repeated, contact Customer Service Center. |
||
Project download |
0x26 | 0x12 | XGT Panel | Failed to delete past project data files. Please download project again. |
When downloading, the log data area in the NV-RAM is initialized in case of selecting previous project’s the monitor data deletion option. By the way, in case of failing this, downloading is stopped. If this problem is repeated, contact Customer Service Center. |
0x15 | XGT Panel | Failed to initialize LOGGING area in NV RAM. Please download project again. |
When downloading, the log data area in the NV-RAM is initialized in case of selecting previous project’s the monitor data deletion option. By the way, in case of failing this, downloading is stopped. If this problem is repeated, contact Customer Service Center. |
||
0x16 | XGT Panel | Failed to initialize RECIPE area in NV RAM. Please download project again. |
When downloading, the alarm history in the NV-RAM is initialized in case of selecting the previous project’s monitor data deletion option. By the way, in case of failing this, downloading is stopped. If this problem is repeated, contact Customer Service Center. |
||
0x17 | XGT Panel | Failed to initialize ALARM area in NV RAM. Please download project again. |
The downloaded font file is moved into original storage location but when this fails, downloading is stopped. If this symptom is repeated, contact Customer Service Center. |
||
0x18 | XGT Panel | Failed to install font files. Please download project again. |
The project data is divided into several files according to the contents but when this fails, downloading is stopped. If this symptom is repeated, contact Customer Service Center. |
||
0x19 | XGT Panel | Failed to unmarshall download file. Please download project again. |
The data divided according to the contents is moved to the original storage location but when this fails, downloading is stopped. If this symptom is repeated, contact Customer Service Center. |
||
0x1A | XGT Panel | Failed to install new project data files. Please download project again. |
The downloaded project is not installed normally because of error of the Flash Disk. Download the project again. If this symptom is repeated, contact Customer Service Center. |
||
0x1B | XGT Panel | Failed to merge data files. Please download project again. |
The downloaded project zip file is moved to the original storage location but when it fails, downloading is stopped. If this symptom is repeated, contact Customer Service Center. |
Appendix 1. Troubleshooting
App.1-12 |
Object | Error code | Occurrence location |
Error message | Reason and measure | |
Type | Address | ||||
0x1C | XGT Panel | Failed to save new project archive. Please download project again. |
There is a program to reboot engine program after downloading in the device but when it fails, this message shows up. But because the downloading is completed if you reboot engine directly, it works normally. The program name to reboot is startup.exe and it can be installed by engine upgrade function. |
||
Project download |
0x26 | 0x1D | XGT Panel | Failed to XGP Panel startup program. Please update XGT Panel Software. |
It can’t find software to reboot XGT Panel. Update the XGT Panel. |
0x1E | XGT Panel | Project data is not downloaded. Please download project again. |
The project data was not downloaded normally because of communication error. Check the connection status of communication cable and If this symptom is repeated, contact Customer Service Center. |
||
0x1F | XGT Panel/ XP-Builder |
Failed to read Version information file. Please download project again. |
There is version information file but when it can’t read file normally because of the device error, downloading is stopped because it doesn’t know version. If this symptom is repeated, contact Custom Service Center |
||
Project download from USB storage device |
0x27 | 0x51 | XGT Panel | Cannot find project data in USB Storage |
There is no USB or device status of USB is not good or project is not saved properly. |
0x52 | XGT Panel | Project information file is not in USB Storage. |
The project is not saved normally in the USB. Check whether there is XP_Project folder and [project name].inf in the USB or not. |
||
0x53 | XGT Panel | Failed to read project information file. |
It can’t read project information file because the project is not saved in the USB normally. Save the project again from XP-Builder to the USB. |
||
0x54 | XGT Panel | Device type is not matched. |
The connected device type is not same as the device type set in the project in the USB. In case of this, project can’t be downloaded into the device. Edit the project again or download according to the connected device. |
||
0x55 | XGT Panel | Cannot read user password. |
Information about the password can’t be red because of the device error. If this symptom is |
Appendix 1. Troubleshooting
App.1-13 |
Object | Error code | Occurrence location |
Error message | Reason and measure | |
Type | Address | ||||
repeated, contact Customer Service Center. | |||||
0x56 | XGT Panel | Password is not matched. |
When saving the project, the password inputted by user is not same as present connection password. Input correct password and save the project. |
||
Project download from USB storage device |
0x27 | 0x57 | XGT Panel | Cannot read XGT Panel software version. |
There is version information file but when it can’t read file normally because of the device error, downloading is stopped because it doesn’t know version. If this symptom is repeated, contact Customer Service Center. |
0x58 | XGT Panel | XGT Panel software is old version. Please update XGT Panel. |
The version of XP-Builder where project is saved is not compatible with present XGT Panel. Update the XGT Panel. |
||
0x58 | XGT Panel | XP-Builder is old version. Please update XP Builder. |
The version of XP-Builder where project is saved is not compatible with present XGT Panel. Update the XGT Panel. |
||
0x59 | XGT Panel | Cannot read download data format version. |
There is storage structure version information file. But when it can’t read this file because of the device error, downloading is stopped because it doesn’t know the version. If this symptom is repeated, contact Customer Service Center. |
||
0x5A | XGT Panel | Download data format version is not matched. Please update XGT Panel. |
Data storage type is not correct. Update XGT Panel. |
||
0x5A | XGT Panel | Download data format version is not matched. Please update XP Builder. |
Data storage type is not correct. Update the XP-Builder. |
||
0x5B | XGT Panel | Data file path is invalid. | There is no project data file at designated location. Check the connection status of USB and if there is no error, save the project to USB again. |
||
0x5C | XGT Panel | Download file name length is invalid. |
The name of project data file is not saved correctly. Save the project at the USB again. If this symptom is repeated, contact Customer Service Center. |
Appendix 1. Troubleshooting
App.1-14 |
Object | Error code | Occurrence location |
Error message | Reason and measure | |
Type | Address | ||||
0x5D | XGT Panel | Cannot find download file. |
The project data file can’t be found. Save the project data file at the USB again. When this symptom is repeated, check the USB. If there is no error, contact Customer Service Center. |
||
0x5E | XGT Panel | Download file size is invalid. |
The project data file is not saved correctly. Save the project data file at the USB again. When this symptom is repeated, check the USB. If there is no error, contact Customer Service Center. |
||
Project download from USB storage device |
0x27 | 0x5F | XGT Panel | Cannot find project backup file. |
The project backup file which should be downloaded is not downloaded because of communication error. Download again. |
0x60 | XGT Panel | Project backup file size is invalid. |
The project backup file is saved incorrectly. Save the project at the USB storage equipment again. When this symptom is repeated, check the USB storage equipment and if the USB is normal, contact Customer Service Center. |
||
0x61 | XGT Panel | Font file name length is invalid. |
The font file’s name is saved incorrectly. Save the project in the USB again. If this symptom is repeated, contact Customer Service Center. |
||
0x62 | XGT Panel | Font file is not downloaded. |
The font file which is needed for project is not saved in the USB storage equipment. Save the project in the USB. If this symptom is repeated, contact Customer Service Center. |
||
0x63 | XGT Panel | Font file size is invalid. | The font file is not saved correctly. Save the project at the USB. Save the project at the USB. If this symptom is repeated, check the USB and if the USB is normal, contact Customer Service Center. |
||
0x64 | XGT Panel | Cannot unmarshall download file. |
The data can’t be analyzed because the project data file is not saved correctly. Save the project at the USB again. If this symptom is repeated, check the USB and if the USB is normal, contact Customer Service Center. |
||
0x65 | XGT Panel | Cannot delete previous project data. |
The data of the project can’t be deleted because of device error. If this symptom is repeated, check the USB and if the USB is normal, contact Customer Service Center. |
||
0x66 | XGT Panel | Cannot move new font files. |
Downloaded font file is moved to the original storage location. But when it fails, the downloading is stopped. If this symptom is repeated, contact Customer Service Center. |
Appendix 1. Troubleshooting
App.1-15 |
Object | Error code | Occurrence location |
Error message | Reason and measure | |
Type | Address | ||||
0x67 | XGT Panel | Cannot move new project data files. |
The project data classified according to the content is moved to the original storage location. But when it fails, the downloading is stopped. If this symptom is repeated, contact Customer Service Center. |
||
0x68 | XGT Panel | Cannot move project backup file. |
The downloaded project zip data is moved to the original storage location. But when it fails, the downloading is stopped. If this symptom is repeated, contact Customer Service Center. |
||
XGT Panel booting |
0x28 | 0x01 | XGT Panel | Previous instance is not terminated. |
XGT Panel software was already started. Reboot the device. If this symptom is repeated, contact Customer Service Center. |
0x02 | XGT Panel | Start Server Fail. Restart XGT Panel |
The XGT Panel software can’t initialize the communication status normally. Check the communication status again. If this symptom is repeated when communication is normal, contact Customer Service Center. |
||
0x03 | XGT Panel | Failed to Start Echo Server. |
The XGT Panel software can’t initialize the communication status normally. Check the communication status again. If this symptom is repeated when communication is normal, contact Customer Service Center. |
||
0x04 | XGT Panel | Failed to accept connection. |
The XGT Panel software can’t initialize the communication with the XP-Builder normally. Check the communication status again. If this symptom is repeated when communication is normal, contact Customer Service Center. |
||
0x05 | XGT Panel | Failed to rename UpdateNew.exe |
In the present XGT Panel the new updated XGT Panel software’s name can not be changed. After rebooting the XGT Panel, update again. When rebooting, if you can’t start engine, delete FlashDiskLSISProductUpdateNew.exe in the XGT Panel. Then if you touch Update.exe and execute the XGT Panel, it can be update mode. Try update again. If this symptom is repeated, contact Customer Service Center |
Appendix 1. Troubleshooting
App.1-16 |
Object | Error code | Occurrence location |
Error message | Reason and measure | |
Type | Address | ||||
0x06 | XGT Panel | Failed to Delete Update.exe. |
The new module is downloaded by the XGT Panel update but the previous module is not deleted. Reboot the device. If the XGT Panel software is not started normally, touch FlashDiskLSISProductUpdate.exe in the XGT Panel. At this time, if XGT is set as update mode, update again. If this symptom is repeated, contact Customer Service Center. |
||
Communicatio n between other XP Builder XGT Panel |
0x29 | 0x30 | XGT Panel | Failed to modify password file. |
The device connection password can’t be modified because of error of Flash Disk of XGT Panel. Reboot the device. If this symptom is repeated, contact Customer Service Center. |
0x31 | XGT Panel | Password-related command transmission payload error |
It failed to set and modify password because of communication status error. If this symptom is repeated, contact Customer Service Center. |
||
0x32 | XGT Panel | There is no XGT Panel connection setting file. |
The connection setting file of XGT Panel can’t be found. |
||
0x33 | XGT Panel | Modified content can’t be saved in the XGT Panel connection setting file. |
The modified information can’t be saved at the connection setting file of XGT Panel. If this symptom is repeated, contact Customer Service Center. |
||
0x34 | XGT Panel | Failed to set the time | The XGT Panel’s time can’t be set. If this symptom is repeated, contact Customer Service Center. |
||
XGT panel S/W update |
0x30 | 0x21 | XGT Panel/ XP-Builder |
Failed to Create Initialized Module Version File. |
Because the each module version information can’t be read because of XGT Panel’s error, it failed to initialize. If this symptom is repeated, contact Customer Service Center. |
0x22 | XGT Panel/ XP-Builder |
Module version file size is invalid. |
The each module version information can’t be read because of XGT Panel’s error. If this symptom is repeated, contact Customer Service Center. |
||
0x23 | XGT Panel/ XP-Builder |
Can't Read module version file. |
The each module version information can’t be read because of XGT Panel’s error. If this symptom is repeated, contact Customer Service Center. |
Appendix 1. Troubleshooting
App.1-17 |
Object | Error code | Occurrence location |
Error message | Reason and measure | |
Type | Address | ||||
0x24 | XP-Builder | There's no file to download. |
The version information list to update is empty. Check the module folder newly designated at XP Builder and if there is no error, download XGT Panel module and try update again. If this symptom is repeated, contact Customer Service Center. |
||
0x25 | XP-Builder | Downloaded file is not Module to download. |
The wrong file which is not in the new module list of XGT Panel is downloaded. Try update of XGT Panel again. If this symptom is repeated, contact Customer Service Center. |
||
XGT panel S/W update |
0x30 | 0x26 | XGT Panel | Not enough space in flash memory. |
The space to copy new module in XGT Panel is not enough. After deleting the unnecessary file or backing up the previous file to the movable storage equipment, try update again. If this symptom is repeated after deleting, contact Customer Service Center. |
0x27 | XGT Panel | Failed to Copy module ~.dll |
The new module is not installed because of XGT Panel’s error. After rebooting the device, touch FlashDiskLSISProductUpdate.exe and set the device as update mode. Then update again. If this symptom is repeated, contact Customer Service Center. |
||
0x28 | XGT Panel | Failed to Start Engine. Please update engine again. |
To reboot the engine is not available because of wrong file which is developed by downloading wrong module or communication error. Touch FlashDiskLSISProductUpdate.exe and set the device as update mode. Then update again. If this symptom is repeated, contact Customer Service Center. |
||
0x2A | XGT Panel | Failed to write Data to Module version File. |
It is failed to record the version information during update of XGT Panel. If this symptom is repeated, contact Customer Service Center. |
Appendix 1. Troubleshooting
App.1-18 |
Object | Error code | Occurrence location |
Error message | Reason and measure | |
Type | Address | ||||
0x2B | XGT Panel | There's no downloaded file. |
To reboot the engine is not available because of wrong file which is developed by downloading wrong module or communication error. Touch FlashDiskLSISProductUpdate.exe and set the device as update mode. Then update again. If this symptom is repeated, contact Customer Service Center. |
||
0x2C | XGT Panel | (improper communication command) Current state is not authorized. |
To reboot the engine is not available because of wrong file which is developed by downloading wrong module or communication error. Touch FlashDiskLSISProductUpdate.exe and set the device as update mode. Then update again. If this symptom is repeated, contact Customer Service Center. |
||
XGT panel S/W update |
0x30 | 0x2D | XGT Panel | (improper communication command) A module to download is not listed up yet. |
To reboot the engine is not available because of wrong file which is developed by downloading wrong module or communication error. Touch FlashDiskLSISProductUpdate.exe and set the device as update mode. Then update again. If this symptom is repeated, contact Customer Service Center. |
0x2E | XGT Panel | Failed to Initialize Update program. |
XGT can’t be set as update mode because of XGT Panel error. After downloading new XGT Panel module through homepage, etc., copy UpdateNew.exe file among new module to the FlashDiskLSISProduct directory of XGT Panel through the movable storage equipment. Then reboot the XGT Panel and go update mode and update again. If this symptom is repeated, contact Customer Service Center. |
Appendix 2. Dimension
App.2-1 |
Appendix 2. Dimension (Unit: mm)
(1) XP30-BTE/DC, XP30-TTE/DC
(2) XP50-TTE/DC
Appendix 2. Dimension
App.2-2 |
(3) XP30-BTA/DC, XP30-TTA/DC
(4) XP40-TTE/DC, XP40-TTA/DC
Appendix 2. Dimension
App.2-3 |
(5) XP50-TTA/DC
(6) XP70-TTA/AC, XP70-TTA/DC
Appendix 2. Dimension
App.2-4 |
(7) XP80-TTA/AC, XP80-TTA/DC
(8) XP90-TTA/AC
Warranty and Environmental Policy
Warranty
1. Warranty Period
The product you purchased will be guaranteed for 18 months from the date of manufacturing.
2. Scope of Warranty
Any trouble or defect occurring for the above-mentioned period will be partially replaced or repaired. However, please
note the following cases will be excluded from the scope of warranty.
Any trouble attributable to unreasonable condition, environment or handling otherwise specified in themanual,
Any trouble attributable to others’ products,
If the product is modified or repaired in any other place not designated by the company,
Due to unintended purposes
Owing to the reasons unexpected at the level of the contemporary science and technology when delivered.
Not attributable to the company; for instance, natural disasters or fire
3. Since the above warranty is limited to HMI unit only, make sure to use the product considering the safety for system
configuration or applications.
Environmental Policy
LS Industrial Systems Co., Ltd supports and observes the environmental policy as below.
LS Industrial Systems considers the
environmental preservation as the preferential
management subject and every staff of LS
Industrial Systems use the reasonable
endeavors for the pleasurably environmental
preservation of the earth.
LS Industrial Systems’ PLC unit is designed
to protect the environment. For the disposal,
separate aluminum, iron and synthetic resin
(cover) from the product as they are
reusable.
Environmental Management About Disposal
■ HEAD OFFICE
LS tower, Hogye-dong, Dongan-gu, Anyang-si, Gyeonggi-do 1026-6,
Korea http://eng.lsis.biz
Tel : (82-2)2034-4870/Fax : 82-2-2034-4648 e-mail : cshwang@lsis.biz
■ LS Industrial Systems Tokyo Office _ Tokyo, Japan
Address: 16FL. Higashi-Kan. Akasaka Twin Tower 17-22,
Akasaka.Monato-ku Tokyo 107-8470. Japan
Tel : 81-3-3582-9128/Fax : 81-3-3582-2667 e-mail : jschuna@lsis.biz
■ LS Industrial Systems(ME) FZE _ Dubai, U.A.E.
Address : Jafza View Tower Lob 19, Room 205 Along Sheikh Zayed
Road Jebel Aali Free Zone Dubai, United Arab Emirates
Tel : 971-4-886-5360/Fax : 971-4-886-5361 e-mail : jungyongl@lsis.biz
■ LS Industrial Systems Shanghai Office _ Shanghai, China
Address : Room E-G. 12FL Hiamin Empire Plaza. No.726. West.
Yan'an Road Shanghai 200050. P.R. China e-mail : liyong@lsis.com.cn
Tel : 86-21-5237-9977(609)/Fax : 89-21-5237-7189
■ LS Industrial Systems Beijing Office _ Beijing, China
Address : B-Tower 17FL. Beijing Global Trade Center B/D. No. 36.
East BeisanHuan-Road. DongCheng-District. Beijing 100013. P.R. China
Tel : 86-10-5825-6027(666)/Fax : 86-10-5825-6028 e-mail : xunmj@lsis.com.cn
■ LS Industrial Systems Guangzhou Office _ Guangzhou, China
Address : Room 1403.14FL. New Poly Tower.
2 Zhongshan Liu Road.Guangzhou.P.R China
Tel : 86-20-8328-6754/Fax : 86-20-8326-6287 e-mail : chenxs@lsis.com.cn
■ LS Industrial Systems Chengdu Office _ Chengdu, China
Address : 12FL. Guodong Buiding. No.52 Jindun
Road Chengdu.610041. P.R. China
Tel : 86-28-8612-9151(9226)/Fax : 86-28-8612-9236 e-mail : comysb@lsis.biz
■ LS Industrial Systems Qingdao Office _ Qingdao, China
Address : YinHe Bldg. 402 Room No. 2P Shandong Road,
Qingdao-City,Shandong-province 266071, P.R. China
Tel : 86-532-8501-6068/Fax : 86-532-8501-6057 e-mail : wangzy@lsis.com.cn
■ LS Industrial Systems Europe B.V. , Netherlands
Address : 1st. Floor, Tupolevlaan 48, 1119NZ, Schiphol-Rijk, The Netherlands
Tel : +31 (0)20 654 1420/Fax : +31 (0)20 654 1429 e-mail : junshickp@lsis.biz
■ Wuxi LS Industrial Systems Co., Ltd _ Wuxi, China
Address : 102-A. National High & New Tech Industrial Development Area.
Wuxi. Jiangsu. 214028. P.R. China
Tel : 86-510-8534-6666/Fax : 86-510-8534-4078 e-mail : caidx@lsis.com.cn
■ Dalian LS Industrial Systems Co., Ltd. _ Dalian, China
Address : No. 15. Liaohexi 3-Road. Economic and Technical Development zone.
Dalian 116600. China
Tel : 86-411-273-7777/Fax : 86-411-8730-7560 e-mail : cuibx@lsis.com.cn
※ LS Industrial Systems constantly endeavors to improve its product so that
information in this manual is subject to change without notice.
ⓒ LS Industrial Systems Co., Ltd 2011 All Rights Reserved.
10310000867
2012. 6
LS values every single customers.
Quality and service come first at LSIS.
Always at your service, standing for our customers.
http://eng.lsis.biz