Read all safety precautions before using this product.
After reading this manual, store it in a readily accessible
location for future reference.
Safety Precautions 400 (400V) |
The Best Choice for the Most Benefit! At LS Mecapion, we are committed to providing premium benefits to all of our customers. AC Servo User Manual L7NH Series AC SERVO DRIVE XGT Servo XDL-L7NH Series User Manual LSIS always tries its best to bring the greatest benefit to its customers. |
Introduction
iii
Introduction
Hello. Thank you for choosing LSIS XDL-L7NH Series.
This user manual describes how to use this product safely and efficiently.
Failure to comply with the guidelines outlined in this manual may cause personal injury or damage to
the product. Be sure to read this manual carefully before using this product and follow all guidelines
contained therein.
The contents of this manual are subject to change without notice.
The reproduction of part or all of the contents of this manual in any form, by any means or for
any purpose is strictly prohibited without the explicit written consent of LSIS.
LSIS retains all patents, trademarks, copyrights and other intellectual property rights to the
material in this manual. The information contained in this manual is only intended for use with
LSIS products.
Safety precautions are categorized as either Warnings or Cautions, depending on the severity
of the precaution.
Precautions | Definition |
Danger | Failure to comply with these guidelines may cause serious injury or death. |
Caution | Failure to comply with these guidelines may cause personal injury or property damage. |
Precautions listed as Cautions may also result in serious injury .
Electric Safety Precautions
Danger |
Before wiring or inspection tasks, turn off the power. Wait 15 minutes until the charge lamp goes off, and then check the voltage. Ground both the servo drive and the servo motor. Only specially trained technicians may perform wiring on this product. Install both the servo drive and servo motor before performing any wiring. Do not operate the device with wet hands. Do not open the servo drive cover during operation. Do not operate the device with the servo drive cover removed. Even if the power is off, do not remove the servo drive cover. |
Fire Safety Precautions
Caution |
Install the servo drive, the servo motor, and the regenerative resistor on non combustible materials. Disconnect the input power if the servo drive malfunctions. |
Introduction
iv
Installation Precautions
Store and operate this product under the following environmental conditions.
Environment | Conditions | |
Servo drive | Servo motor | |
Operating temp. |
0 ~ 50 ℃ | 0 ~ 40 ℃ |
Storage temp. | -20 ~ 65 ℃ | -10 ~ 60 ℃ |
Operating humidity |
Below 90% RH (no condensation) | 20~80% RH(no condensation) |
Storage humidity |
||
Altitude | 1000 m or lower | |
Spacing | When installing 1 unit: More than 40 mm at the top and bottom of the control panel More than 10 mm on the left and right sides of the control panel When installing 2 or more units: More than 100 mm at the top of the control panel More than 40 mm at the bottom of the control panel More than 30 mm on the left and right sides of the control panel More than 2 mm between units Refer to Section 2.2.1, "Wiring the Control Panel." |
|
Other | Ensure the installation location is free from dust, iron, corrosive gas, and combustible gas. Ensure the installation location is free from vibrations or the potential for hard impacts. |
Caution |
Install the product with the correct orientation. Do not drop the product or expose it to hard impact. Install this product in a location that is free from water, corrosive gas, combustible gas, or flammable materials. Install this product in a location capable of supporting the weight of this product. Do not stand on the product or place heavy objects on top of it. Always maintain the specified spacing when installing the servo drive. Ensure that there are no conductive or flammable debris inside the servo drive or the servo motor. Firmly attach the servo motor to the machine. Install the servo motor with a correctly oriented decelerator. Do not touch the rotating unit of the servo motor during operation. Do not apply excessive force when connecting the couplings to the servo motor shaft. Do not place loads on the servo motor shaft that exceed the specified amount. |
Introduction
v
Wiring Precautions
Caution |
Always use an AC 380-480 V power input for the servo drive. Always connect the servo drive to a ground terminal. Do not connect commercial power directly to the servo motor. Do not connect commercial power directly to the U, V, W output terminals of the servo drive. Connect the U, V, W output terminals of the servo drive directly to the U, V, W input terminals of the servo motor, but do not install magnetic contactors between the wires. Always use pressurized terminals with insulation tubes when connecting the servo drive power terminal. When wiring, be sure to separate the U, V, and W cables for the servo motor power and encoder cable. Always use the robot cable if the motor moves. Before you perform power line wiring, turn off the input power of the servo drive, and then wait until the charge lamp goes off completely. |
Startup Precautions
Caution |
Check the input voltage (AC 380-480 V) and power unit wiring before supplying power to the device. The servo must be in the OFF mode when you turn on the power. Before you turn on the power, check the motor's ID and the encoder pulse for XDL L7NHB □□□. Set the motor ID[0x2000], encoder type[0x2001] and the encoder pulse [0x2002] for XDL-L7NHB□□□ first after you turn on the power. After you complete the above settings, set the drive mode for the servo drive that is connected to the upper level controller in [0x6060]. Refer to Chapter 1.4 "System Configuration" to perform I/O wiring for the servo drive according to each drive mode. You can check the ON/OFF state for each input terminal of I/O at [0x60FD]. |
Handling and Operating Precautions
Caution |
Check and adjust each parameter before operation. Do not touch the rotating unit of the motor during operation. Do not touch the heat sink during operation. Be sure to attach or remove the I/O and ENCODER connectors when the power is off. Extreme change of parameters may cause system instability. |
Introduction
vi
Usage Precautions
Caution |
Install an emergency cut-off switch which immediately stops operation in an emergency. Reset the alarm when the servo is off. Be warned that the system restarts immediately if the alarm is reset while the servo is on. Use a noise filter or DC reactor to minimize electromagnetic interference. This prevents nearby electrical devices from malfunctioning due to interference. Only use approved servo drive and servo motor combinations. The electric brake on the servo motor stops operation. Do not use it for ordinary braking. The electric brake may malfunction if the brake degrades or if the mechanical structure is improper (for example, if the ball screw and servo motor are combined via the timing belt). Install an emergency stop device to ensure mechanical safety. |
Malfunction Precautions
Caution |
Install a servo motor with an electric brake or separate the brake system for use during emergencies or device malfunctions. If an alarm occurs, solve the underlying cause of the problem. After solving the problem and ensuring safe operation, deactivate the alarm and resume operation. Do not approach the machine until the problem is solved. |
Repair/Inspection Precautions
Caution |
Before performing servicing tasks, turn off the power. Wait 15 minutes until the charge lamp goes off, and then check the voltage. Enough voltage may remain in the condenser after the power is off to cause an electric shock. Only authorized personnel may repair and inspect the device or replace its parts. Do not modify this device in any way. |
General Precautions
Caution |
This user manual is subject to change due to product modification or changes in standards. If such changes occur, we issue a new user manual with a new product number. |
Product Application
Caution |
This product is not designed or manufactured for machines or systems intended to sustain human life. This product is manufactured under strict quality control conditions. Nevertheless, install safety devices if installing the device in a facility where product malfunctions may result in a major accident or a significant loss. |
Introduction
vii
EEPROM Lifespan
Caution |
The EEPROM is rewritable up to 4 million times for the purpose of recording parameter settings and other information. The servo drive may malfunction if the total number of the following tasks exceeds 4 million, depending on the lifespan of the EEPROM. EEPROM recording as a result of parameter changes EEPROM recording as a result of an alarm |
Table of Contents
viii
Table of Contents
1. Product Configuration ....................................................................................... 1-1
1.1 Product Verification.......................................................................................................... 1-1
1.2 Product Specifications ..................................................................................................... 1-2
1.3 Part Names ...................................................................................................................... 1-4
1.3.1 Servo Drive Parts ............................................................................................. 1-4
1.3.2 Servo Motor Parts............................................................................................. 1-9
1.4 System Configuration Example ..................................................................................... 1-10
2. Wiring and Connection ...................................................................................... 2-1
2.1 Installation of Servo Motor ............................................................................................... 2-1
2.1.1 Operating Environment .................................................................................... 2-1
2.1.2 Preventing Impact............................................................................................. 2-1
2.1.3 Motor Connection ............................................................................................. 2-1
2.1.4 The Load Device Connection........................................................................... 2-2
2.1.5 Cable Installation .............................................................................................. 2-2
2.2 Installation of Servo Drive ................................................................................................ 2-3
2.2.1 Installation and Usage Environment ................................................................ 2-3
2.3 Internal Block Diagram of Drive ....................................................................................... 2-4
2.3.1 XDL-L7NH Drive Block Diagram (XDL-L7NHB010U~ XDL-L7NHB035U) ...... 2-4
2.3.2 XDL-L7NH Drive Block Diagram (XDL-L7NHB050U~ XDL-L7NHB075U) ...... 2-5
2.3.3 XDL-L7NH Drive Block Diagram (XDL-L7NHB150U) ...................................... 2-6
2.4 Power Supply Wiring ....................................................................................................... 2-7
2.4.1 Power Supply Wiring Diagram ......................................................................... 2-8
2.4.2 Power Circuit Electrical Components .............................................................. 2-11
2.4.3 Regenerative Resistor Options ...................................................................... 2-17
2.5 Wiring for Input/Output Signals...................................................................................... 2-18
2.5.1 Names and Functions of Digital Input/Output Signals ................................... 2-18
2.5.2 Names and Functions of Analog Input/Output Signals .................................. 2-20
2.5.3 Examples of Connecting Input/Output Signals .............................................. 2-22
2.5.4 Examples of Connecting Input/Output Signals .............................................. 2-24
2.6 Wiring of Encoder Signal (ENCODER) .......................................................................... 2-25
2.6.1 Quadrature Encoder Signaling Unit Wiring .................................................... 2-25
2.6.2 Serial Encoder Signaling Unit Wiring ............................................................. 2-26
2.6.3 Multi-Turn Encoder Signaling Unit Wiring ...................................................... 2-28
2.6.4 Tamagawa Encoder Signaling Unit Wiring ..................................................... 2-29
2.6.5 EnDat 2.2 Encoder Signaling Unit Wiring ...................................................... 2-30
2.7 Wiring for Safety Function Signals (STO) ...................................................................... 2-31
2.7.1 Names and Functions of Safety Function Signals ......................................... 2-31
2.7.2 Example of Connecting Safety Function Signals ........................................... 2-32
2.7.3 Bypass Wiring of Safety Function Signal ....................................................... 2-33
2.8 Wiring for EtherCAT Communication Signals ................................................................ 2-34
2.8.1 Names and Functions of EtherCAT Communication Signals......................... 2-34
2.8.2 Example of Drive Connection ......................................................................... 2-35
3. EtherCAT Communication................................................................................. 3-1
3.1 Structure of CANopen over EtherCAT ............................................................................. 3-1
Table of Contents
ix
3.1.1 EtherCAT State Machine ...................................................................................3-2
3.2 Status LED ........................................................................................................................3-3
3.3 Data Type ..........................................................................................................................3-5
3.4 PDO assignment ...............................................................................................................3-5
3.5 Synchronization Using the DC (Distributed Clock) ...........................................................3-8
3.6 Emergency Messages ......................................................................................................3-9
4. CiA402 Drive Profile ........................................................................................... 4-1
4.1 State machine ...................................................................................................................4-1
4.2 Operation Modes ..............................................................................................................4-3
4.3 Position Control Modes.....................................................................................................4-5
4.3.1 Cyclic Synchronous Position Mode ...................................................................4-5
4.3.2 Profile Position Mode ........................................................................................4-8
4.4 Velocity Control Mode.....................................................................................................4-13
4.4.1 Cyclic Synchronous Velocity Mode .................................................................4-13
4.4.2 Profile Velocity Mode .......................................................................................4-16
4.5 Torque Control Modes ....................................................................................................4-19
4.5.1 Cyclic Synchronous Torque Mode ...................................................................4-19
4.5.2 Profile Torque Mode ........................................................................................4-21
4.6 Homing............................................................................................................................4-23
4.6.1 Homing Method ...............................................................................................4-24
4.7 Touch Probe Function .......................................................................................................4-2
5. Drive Application Functions.............................................................................. 5-1
5.1 Drive Front Panel ..............................................................................................................5-1
5.1.1 7-Segment for indicating servo status ...............................................................5-1
5.2 Input/Output Signals Setting .............................................................................................5-4
5.2.1 Assignment of Digital Input Signals...................................................................5-4
5.2.2 Assignment of Digital Output Signals ................................................................5-6
5.2.3 Use of User I/O ..................................................................................................5-8
5.3 Electric Gear Setup.........................................................................................................5-15
5.3.1 Electric Gear ....................................................................................................5-15
5.3.2 Example of Electric Gear Setup ......................................................................5-16
5.4 Settings Related to Speed Control .................................................................................5-17
5.4.1 Smooth Acceleration and Deceleration ...........................................................5-17
5.4.2 Servo-lock Function.........................................................................................5-18
5.4.3 Signals Related to Speed Control ...................................................................5-18
5.5 Settings Related to Position Control ...............................................................................5-19
5.5.1 Position Command Filter.................................................................................5-19
5.5.2 Signals Related to Position Control.................................................................5-21
5.6 Settings Related to Torque Control .................................................................................5-22
5.6.1 Speed Limit Function .......................................................................................5-22
5.7 Positive/Negative Limit Settings .....................................................................................5-23
5.8 Setting the Brake Output Signal Function ......................................................................5-24
5.9 Torque Limit Function .....................................................................................................5-26
5.10 Gain switching function ...................................................................................................5-29
Table of Contents
x
5.10.1 Gain group switching...................................................................................... 5-29
5.10.2 P/PI Control Switching .................................................................................... 5-31
5.11 Dynamic brake ............................................................................................................... 5-33
5.12 Regenerative resistance setting .................................................................................... 5-34
5.12.1 Use of Internal Regenerative Resistor ........................................................... 5-35
5.12.2 Use of External Regenerative Resistor .......................................................... 5-37
5.12.3 Other Considerations ..................................................................................... 5-38
5.13 Configuration of Drive Node Address (ADDR) .............................................................. 5-39
6. Safety Functions ................................................................................................ 6-1
6.1 Safe Torque Off (STO) Function ...................................................................................... 6-1
6.2 External Device Monitor (EDM) ....................................................................................... 6-4
6.3 Example of Using Safety Function .................................................................................. 6-5
6.4 How to Verify Safety Function.......................................................................................... 6-5
6.5 Precautions for Using Safety Function ............................................................................ 6-6
7. Tuning .................................................................................................................. 7-1
7.1 Auto Gain Tuning ............................................................................................................. 7-1
7.2 Manual Gain Tuning......................................................................................................... 7-2
7.2.1 Gain Tuning Sequence..................................................................................... 7-3
7.3 Vibration Control .............................................................................................................. 7-5
7.3.1 Notch Filter ....................................................................................................... 7-5
7.3.2 Adaptive Filter................................................................................................... 7-6
7.4 Analog Monitor ................................................................................................................. 7-7
8. Procedure Function ........................................................................................... 8-1
8.1 Manual JOG Operation.................................................................................................. 8-1
8.2 Programmed Jog Operation ............................................................................................ 8-2
8.3 Deleting Alarm History ..................................................................................................... 8-3
8.4 Auto Gain Tuning ............................................................................................................. 8-5
8.5 Index Pulse Search.......................................................................................................... 8-5
8.6 Absolute encoder reset .................................................................................................... 8-6
8.7 Instantaneous Maximum Torque Initialization .................................................................. 8-6
8.8 Phase current offset tuning .............................................................................................. 8-7
8.9 Software reset .................................................................................................................. 8-8
8.10 Commutation .................................................................................................................... 8-8
9. Object Dictionary ................................................................................................ 9-1
9.1 General Objects ............................................................................................................... 9-1
9.2 Manufacturer Specific Objects ....................................................................................... 9-17
9.3 CiA402 Objects .............................................................................................................. 9-68
10. Product Specifications .................................................................................... 10-1
10.1 Servo Motor ................................................................................................................... 10-1
10.1.1 Product Characteristcs................................................................................... 10-1
10.1.2 Outline Diagram ........................................................................................... 10-19
Table of Contents
xi
10.2 Servo Drive ...................................................................................................................10-29
10.2.1 Product Characteristics .................................................................................10-29
10.2.2 Outline Diagram ............................................................................................10-32
10.3 Options and Peripheral Devices ...................................................................................10-35
11. Maintenance and Inspection ......................................................................... 11-43
11.1 Maintenance and Inspection......................................................................................... 11-43
11.1.1 Precautions ................................................................................................... 11-43
11.1.2 What to Inspect ............................................................................................. 11-43
11.1.3 Replacing Parts ............................................................................................. 11-44
11.2 Diagnosing and Troubleshooting Abnormalities ........................................................... 11-45
11.2.1 Servo Motor ................................................................................................... 11-45
11.2.2 Servo Drive .................................................................................................... 11-46
12. Test Drive ........................................................................................................ 11-54
12.1 Preparation for Operation ...............................................................................................12-3
12.2 Test Drive Using TwinCAT System Manager ..................................................................12-4
12.3 Test Drive Using LSIS PLC (XGT + PN8B) ..................................................................12-12
13. Appendix ......................................................................................................... 13-19
13.1 Firmware Update ..........................................................................................................13-19
13.1.1 Use of USB OTG ...........................................................................................13-19
13.1.2 Use of FoE (File access over EtherCAT) ......................................................13-21
13.1.3 Use of Drive CM ............................................................................................13-25
1. Product Configuration
1-1
1. Product Configuration
1.1 Product Verification
1. Check the name tag to verify that the product received matches the model ordered
Does the servo drive's name plate match?
Does the servo motor's name plate match?
2. Check the product components and options.
Are the type and length of cables correct?
Does the regenerative resistor conform to the required standard?
Is the shape of the shaft correct?
Are there any abnormalities after mounting the oil seal or brake?
Are the gearbox and the gear ratios correct?
Is the encoder format correct?
3. Check the exterior of the device.
Are there any foreign substances or humidity in the device?
Is there any discoloration, contaminant, damage or disconnected wire?
Are the bolts tightly fastened to the joints?
Is there any abnormal sound or excessive friction during operation?
1. Product Configuration
1-2
1.2 Product Specifications
XDL-L7NH Series Product Type
XDL-L7 NH B 010 U AA
Input voltage |
A: 200Vac B: 400Vac |
Option |
Black: Standard Marked: Dedicated use |
Encoder U: Universal |
Series Name | Communicatio /Drive Type NH : Network typ All-in-One T |
L7 Series L7 Series |
|
n e ype |
apacity : 11.0kW : 15kW |
001 : 100W 002 : 200W 004 : 400W 008 : 750W 010 : 1kW 020 : 2kW 035 : 3.5kW 050 : 5.0kW 075 : 7.5kW |
1. Product Configuration
1-3
Servo Motor Product Format
APM – S E P 10 D E K 1 G1 03
Motor Shape
S: 실축형
H: 중공축형
B: 조립형
Servo Motor Servo Motor |
Flange Size
A: 40 Flange
B: 60 Flange
C: 80 Flange
D: 100 Flange
E: 130 Flange
F: 180 Flange
G: 220 Flange
Gearbox
Classification
03: 1/3
10: 1/10
Gearbox Spec. | 형상 |
Non-existent: No gearbox G1: For general industrial purposes G2: For general industrial purposes G3: Precise Gearbox |
Oil Seal, Brake Existence |
Non-existent: None included 1: Oil Seal attached 2: Brake attached 3: Oil Seal and Brake Non-existent: None included 1: Oil Seal attached 2: Brake attached 3: Oil Seal and Brake |
Motor
R3: 30[W]
R5: 50[W]
01: 100[W]
02: 200[W]
03: 300[W]
04: 400[W]
06: 550/600[W]
07: 650[W]
08: 750/800[W]
10: 1[kW]
15: 1.5[kW]
20: 2[kW] 35: 3.5[kW] 50: 5[kW] 75: 7.5[kW] 150: 15[kW] 220: 22[kW] 300: 30[kW] 370: 37[kW] |
A: 3000[ D: 2000 Serial BiSS( |
rpm [rpm |
Rated RPM | ||
G: 1500[rpm] M: 1000[rpm] |
||
Enc A: Inc. 1 B: Inc. 2 C: Inc. 2 D: Inc. 2 E: Inc. 3 F: Inc. 5 G: Inc. 6 N : 19bit M : 19bit Enc |
oder Ty 024[ppr] 000[ppr] 048[ppr] 500[ppr] 000[ppr] 000[ppr] 000[ppr] SingleTu MultiTur oder Typ |
p rn n e |
Quadrature(Pulse type) Communication type) |
Shaft Shape
N: Straight
K: 한쪽 둥근키(표준)
C: C Cut
D: D Cut
T: Taper R: 양쪽 둥근키
H: Hollow Shaft
Input
Blank: 200[Vac]
P: 400[Vac
Motor Shape
Input
Motor
One-sided round key
(standard)
Taper shape
Double-sided
S: Real Axis
H: Hollow Shaft
B: Assembly
1. Product Configuration
1-4
1.3 Part Names
1.3.1 Servo Drive Parts
XDL-L7NH Drive (1KW)
CHARGE lamp
This turns on when the main circuit power is on.
DC reactor connector (PO, PI)
These terminals connect to the DC reactor to
suppress high-frequency power.
-If the DC reactor is not used, be sure to shortcircuit this connector.
Regenerative resistance connector (B+, B, BI)
These terminals connect to the external regenerative resistor.
-For basic installations : Short-circuit B and BI terminals.
-For external resistor installations : Install to B+ and B terminals.
Control power terminals (C1 and C2)
These terminals connect to the control power input.
Servo motor connection terminals (U,V,W)
These terminals connect to the main circuit cable
(power cable) of the servo motor.
Ground terminal
It is a ground terminal to prevent electric shock.
Connector for analog monitors
It is a connector for checking the analog output
signal.
Node address setting switch
This switch is to set the node address of the drive.
You can set the node addresses from 0 to 99.
USB connector (USB)
This connector is to communicate with a PC.
EtherCAT communication input port (ECAT IN)
EtherCAT communication output port (ECAT
OUT)
Safety connector (STO)
This connector connects safety devices.
-If a safety device is not used, be sure to install the
safety jump connector before use.
Input/output signal connector (I/O)
This connector is for sequence input/output signals.
Encoder connector (ENCODER)
This connector connects to the encoder
installed in the servo motor.
Display
It shows drive status, alarms, etc.
Status LED
It indicates the current state of EtherCAT
communication.
Main power connectors (L1, L2, and L3)
These terminals connect to the main circuit power
input.
1. Product Configuration
1-5
XDL-L7NH Drive (2KW, 3.5KW)
CHARGE lamp
This turns on when the main circuit
power is on.
Display
It shows drive status, alarms, etc.
Status LED
It indicates the current state of
EtherCAT communication.
Main power connectors
(L1, L2, and L3)
These terminals connect to the main
circuit power input.
DC reactor connector (PO, PI)
These terminals connect to the DC
reactor to suppress high-frequency
power.
-If the DC reactor is not used, be sure to
short-circuit this connector.
Regenerative resistance connector
(B+, B, BI)
These terminals connect to the external
regenerative resistor.
-For basic installations : Short-circuit B
and BI terminals.
-For external resistor installations:
Install to B+ and B terminals.
Control power terminals (C1 and C2)
These terminals connect to the control power
input.
Servo motor connection terminals (U,V,W)
These terminals connect to the main circuit cable
(power cable) of the servo motor.
Ground terminal
It is a ground terminal to prevent electric
shock.
Connector for analog monitors
It is a connector for checking the analog output
signal.
Node address setting switch
This switch is to set the node address of the
drive.
Y h d dd f 0
USB connector (USB)
This connector is to communicate with a PC.
EtherCAT communication input port (ECAT IN)
EtherCAT communication output port
(ECAT OUT)
Safety connector (STO)
This connector connects safety devices.
-If a safety device is not used, be sure to install
the safety jump connector before use.
Input/output signal connector (I/O)
This connector is for sequence input/output
signals.
Encoder connector (ENCODER)
This connector connects to the encoder
installed in the servo motor.
1. Product Configuration
1-6
XDL-L7NH Drive (5KW)
CHARGE lamp
This turns on when the main circuit power
is on.
Display
It shows drive status, alarms,
etc.
Status LED
It indicates the current state of
EtherCAT communication.
Main power connectors (L1, L2, and L3)
These terminals connect to the main circuit
power input.
DC reactor connector (PO, PI)
These terminals connect to the DC reactor
to suppress high-frequency power.
-If the DC reactor is not used, be sure to
short-circuit this connector.
Regenerative resistance connector (B+, B)
These terminals connect to the external
regenerative resistor.
-For basic installations : Short-circuit B+ and B
terminals.
-For external resistor installations : After
attaching internal resistor wiring to the internal
resistor fixing hole “NC” of the case, connect
the external resistor to B+ and B terminals.
Control power terminals (C1 and C2)
These terminals connect to the control
power input.
Servo motor connection terminals (U,V,W)
These terminals connect to the main circuit
cable (power cable) of the servo motor.
Ground terminal
It is a ground terminal to prevent electric
shock.
Connector for analog monitors
It is a connector for checking the analog
output signal.
Node address setting switch
This switch is to set the node address of the
drive. You can set the node addresses from 0
to 99.
USB connector (USB)
This connector is to communicate with a PC.
EtherCAT communication input port
(ECAT IN)
EtherCAT communication output port
(ECAT OUT)
Safety connector (STO)
This connector connects safety devices.
-If a safety device is not used, be sure to
install the safety jump connector before use.
Input/output signal connector (I/O)
This connector is for sequence
input/output signals.
Encoder connector (ENCODER)
This connector connects to the encoder
installed in the servo motor.
* It is not a connector for
connection (N)
1. Product Configuration
1-7
XDL-L7NH Drive (7.5KW)
CHARGE lamp
This turns on when the main
circuit power is on.
Display
It shows drive status,
alarms, etc.
Status LED
It indicates the current state of
EtherCAT communication.
Main power connectors (L1, L2,
and L3)
These terminals connect to the
main circuit power input.
DC reactor connector (PO, PI)
These terminals connect to the DC reactor to
suppress high-frequency power.
-If the DC reactor is not used, be sure to short-circuit
this connector. Regenerative resistance connector (B+, B)
These terminals connect to the external regenerative resistor.
-For basic installations : Short-circuit B+ and B terminals. -For external resistor installations : After attaching internal resistor |
* NC |
wiring to the internal resistor fixing hole “NC” of the case, connect
the external resistor to B+ and B terminals.
Control power terminals (C1 and C2)
These terminals connect to the control
power input.
Ground terminal
It is a ground terminal to prevent electric shock.
Connector for analog monitors
It is a connector for checking the analog
output signal.
Node address setting switch
This switch is to set the node address of
the drive. You can set the node addresses
from 0 to 99.
USB connector (USB)
This connector is to communicate with a
PC.
EtherCAT communication input port
(ECAT IN)
EtherCAT communication output port
(ECAT OUT)
Safety connector (STO)
This connector connects safety
devices.
-If a safety device is not used, be sure
to install the safety jump connector
before use.
Input/output signal connector (I/O)
This connector is for sequence
input/output signals.
Encoder (ENCODER) |
connector |
This connector connects to the
encoder installed in the servo
t
* It is not a connector
for connection (N)
Servo motor connection terminals
(U,V,W)
These terminals connect to the main
circuit cable (power cable) of the servo
motor.
1. Product Configuration
1-8
XDL-L7NH Drive (15KW)
CHARGE lamp
This turns on when the
main circuit power is on.
Display
It shows drive status,
alarms, etc.
Status LED
It indicates the current state of
EtherCAT communication.
Main power connectors (L1,
L2, and L3)
These terminals connect to the
main circuit power input.
DC reactor connector (PO, PI)
These terminals connect to the DC reactor to
suppress high-frequency power.
-If the DC reactor is not used, be sure to shortcircuit this connector.
Regenerative resistance connector (B+, B)
These terminals connect to the external
regenerative resistor.
-Install external regenerative resistance
Control power terminals
(C1 and C2)
These terminals connect to
the control power input.
Ground terminal
It is a ground terminal to prevent electric shock.
Connector for analog monitors
It is a connector for checking the analog
output signal.
Node address setting switch
This switch is to set the node address of the
drive. You can set the node addresses from 0
to 99.
USB connector (USB)
This connector is to communicate with a PC.
EtherCAT communication input port
(ECAT IN)
EtherCAT communication output port
(ECAT OUT)
Safety connector (STO)
This connector connects safety devices.
-If a safety device is not used, be sure to
install the safety jump connector before use.
Input/output signal connector (I/O)
This connector input/output signals. |
is for sequence |
Encoder connector (ENCODER)
This connector connects to the encoder
installed in the servo motor.
Z |
* It is not a connector for
connection (N)
Servo (U,V,W) |
motor connection terminals |
These terminals connect to the main circuit
cable (power cable) of the servo motor.
1. Product Configuration
1-9
1.3.2 Servo Motor Parts
80 Flange or below
130 Flange or higher
1. Product Configuration
1-10
1.4 System Configuration Example
The figure below shows an example of system configuration using this drive.
미니 USB
케이블
U S B
미니 USB
젠더
미니 USB
케이블
ADDR 0 5 0 5 |
Node 주소 설정 스위치
상위 장치
XGT |
전원
삼상 AC380V
R S T
배선용 차단기
전원라인을 보호하기
위하여 사용합니다.
과전류가 흐르면
회로를 OFF합니다.
노이즈 필터
전원라인으로부터의
외부 노이즈를
막습니다.
전자 접촉기 서보전원을 ON / OFF로 합니다. Electromagnetic contactor It turns servo power ON / OFF. |
안전 기기
3M
10314
3M 10314 모터 케이블 Motor cable |
1.기본 장착 사용 시
- 단락(B, BI)
2.외부 저항 장착 시
- 장착(B, B+)
회생 저항 연결
DC 리액터 연결
-미사용 시 단락(PO, PI)
1. 안전기능 을
사용하지 않을 경우 :
안전점프 커넥터 설치
2. 안전기능을 사용
할 경우 :
NOT | HOME |
POT
안전 케이블
엔코더 케이블
I/O Cable
EtherCAT 통신케이블
서보모터
서보 드라이브 Servo Drive |
아날로그 모니터 케이블 Analog monitor cable |
오실로스코프
DAQ
Oscilloscope
Power
Three-phase AC380V
Upper device
Molded case circuit
breaker
It is used to protect
power line.
It turns the circuit OFF
if overcurrent flows.
Noise filter
It protects power line
from external noise. Node address setting switch
EtherCAT communication cable
Connect a
regenerative resistor.
1.When using basic
installations
-Short-circuit (B, BI)
2.When installing
external resistance
-Install it (B, B+)
DC reactor connection
-Short-circuit if not used
(PO, PI)
Safety cable
1.If the safety function
is not used : Install the
safety jump connector.
2.If the safety
function is used
Mini USB
cable
Mini USB
cable
Mini USB
adaptor
Safety device
Encoder cable
Servo Motor
2. Wiring and Connection
2-1
2. Wiring and Connection
2.1 Installation of Servo Motor
2.1.1 Operating Environment
Item | Requirements | Notes |
Ambient temperature |
0 ∼ 40[℃] | Consult with our technical support temperatures in the installation environment are outside this range. team to customize the product if |
Ambient humidity |
80% RH or lower | Do not operate this device in an environment with steam. |
External vibration |
Vibration acceleration 19.6 ㎨ or below on both the X and Y axis. |
Excessive vibrations reduce the lifespan of the bearings. |
2.1.2 Preventing Impact
Impact to the motor during installation or handling may damage the encoder.
2.1.3 Motor Connection
If the motor is directly connected to commercial power, it may be burned. Be sure to connect with
the specified drive before using it.
Connect the ground terminals of the motor to either of the two ground terminals inside the drive,
and attach the remaining terminal to the type-3 ground.
Connect the U, V, and W terminals of the motor in the same way as the U, V, and W terminals of
the drive.
Ensure that the pins on the motor connector are securely attached.
In order to protect against moisture or condensation in the motor, make sure that insulation
resistance is 10 ㏁ (500 V) or higher before installation.
Caution
U – U
V - V
W – W
- F.G
2. Wiring and Connection
2-2
2.1.4 The Load Device Connection
For coupling connections: Ensure that the motor shaft and load shaft are aligned within the tolerance
range.
For pulley connections:
Flange | Lateral Load | Axial Load | Notes | ||
N | kgf | N | kgf | ||
40 | 148 | 15 | 39 | 4 | Nr: 30 ㎜ or below Lateral load Axial load |
60 | 206 | 21 | 69 | 7 | |
80 | 255 | 26 | 98 | 10 | |
130 | 725 | 74 | 362 | 37 | |
180 | 1548 | 158 | 519 | 53 | |
220 | 1850 | 189 | 781 | 90 |
2.1.5 Cable Installation
For vertical installations, make sure that no oil or water flows into the connecting parts.
Do not apply pressure to or damage the cables. Use robot cables to prevent swaying when the
motor moves.
Load
shaft
Motor
shaft
0.03 ㎜ or below (peak to peak)
0.03 ㎜ |
or below (peak to peak)
2. Wiring and Connection
2-3
2.2 Installation of Servo Drive
2.2.1 Installation and Usage Environment
Item | Environmental conditions |
Notes |
Ambient temperature |
0∼50[℃] | Caution Install a cooling fan on the control panel to maintain an appropriate temperature. |
Ambient humidity |
90% RH or lower | Caution Condensation or moisture may develop inside the drive during prolonged periods of inactivity and damage it. Remove all moisture before operating the drive after a prolonged period of inactivity. |
External vibration |
Vibration acceleration 4.9 ㎨ or lower |
Excessive vibration reduces the lifespan of the machine and may cause malfunctions. |
Ambient conditions |
Do not expose the device to direct sunlight. Do not expose the device to corrosive or combustible gases. Do not expose the device to oil or dust. Ensure that the device receives sufficient ventilation. |
2. Wiring and Connection
2-4
2.3 Internal Block Diagram of Drive
2.3.1 XDL-L7NH Drive Block Diagram
(XDL-L7NHB010U~ XDL-L7NHB035U)
아날로그 출력 연결
Diode
L3
AC380~480V
3상 전원 입력
L1
L2
Lamp
Chage
써미스터
입력
P/C 절연 I/F
입/출력 연결(I/O)
디지털입력
(8점) (4점)
디지털출력
POWER 회로 접속
SC검출회로
PWM신호
MCU / FPGA
구동회로
회생제동
엔코더
검출회로
U,V전류
구동회로
DB
ENCODER
M
IGBT
회생저항
W
전류 센서
U V
B B+ BI
E
PO PI
검출회로
IGBT온도
검출회로
C1
C2
SMPS
T1 T2
써미스터
Relay
구동회로
단상 전원 입력
AC380V~480V
USB
USB 통신
ECAT IN/OUT
USB OTG FS
Quadrature
검출회로
내부온도
써미스터
제어전원결상
검출회로 검출회로
주전원결상
(2점)
안전기능입력
안전기기 연결(STO)
ESC
A/D 변환 BiSS-C
TAMAGAWA
EnDat
(2점)
아날로그출력
Main 제어
DC전압
(1점)
안전기능출력
DC전압
EtherCAT
통신
U,V전류
0 1
2
3 4
5 6
8 9
7
x10
2
3 4
5 6
8 9
7
x1
0 1
주1) 주2)
주3)
(1점)
아날로그 입력
Note 1) If using a DC reactor, connect the PO and PI pins.
Note 2) If using an external regenerative resistor, remove the B and BI short-circuit pins and
connect the B+ and B pins.
Note 3) XDL-L7NHB010U~ XDL-L7NHB035U Model is cooled by a DC 24 V cooling fan.
Note 1) Note 2)
010 : Thermistor Note 3)
035 : Resistor
3-phase power Input
Regenerative Current sensor
Resistor
Thermistor
Thermistor
Control Power Phase
Loss Detection Circuit
Main Power Phase
Loss Detection
Circuit
Internal
Temperature
Detection Circuit driving circuit
DC Voltage
Detection Circuit
Regenerative
Brake Drive
Circuit
IGBT Temperature
Detection Circuit
PWM Signal SC
Detection Circuit
U and V Current
Detection Circuit
DB Drive Circuit
Single-phase power Input
Main Control POWER circuit connection
U,V Current
DC Voltage
EtherCAT
Communication
USB
communication
A/D Conversion
Encoder Input
P/C Insulation I/F
Safety Function Input
(2 Points)
Safety Function Output
(1 Point)
Digital input
(8 points)
Digital Output
(4 points)
Analog Input (1 Point) Analog output
(2 points)
Safety device connection (STO) Input/output connection (I/O) Analog output connection
2. Wiring and Connection
2-5
2.3.2 XDL-L7NH Drive Block Diagram
(XDL-L7NHB050U~ XDL-L7NHB075U)
아날로그 출력 연결 입력 P/C 절연 I/F 입/출력 연결(I/O) 디지털입력 (8점) (4점) 디지털출력 POWER 회로 접속 MCU / FPGA 엔코더 ENCODER C1 C2 SMPS 입력 USB USB 통신 ECAT IN/OUT USB OTG FS Quadrature (2점) 안전기능입력 안전기기 연결(STO) ESC A/D 변환 BiSS-C TAMAGAWA EnDat (2점) 아날로그출력 Main 제어 (1점) 안전기능출력 DC전압 EtherCAT 통신 U,V전류 0 1 2 3 4 5 6 8 9 7 x10 2 3 4 5 6 8 9 7 x1 0 1 (1점) 아날로그 입력 P/C Insulation I/F Safety Function Input (2 Points) Safety Function Output (1 Point) Digital input (8 points) Digital Output (4 points) Analog Input (1 Point) Analog output (2 points) Safety device connection (STO) Input/output connection (I/O) Analog output connection U,V Current DC Voltage EtherCAT Communication USB communication A/D Conversion Encoder Input Main Control POWER circuit connection Input |
||||||||
Diode L3 C380~480V 3상 전원 입력 L1 L2 써미스터 제어전원결상 검출회로 검출회로 주전원결상 3-phase power Input Thermistor Control Power Phase Loss Detection Circuit Main Power Phase Loss Detection Circuit |
Lamp Chage 써미스터 PO 주1) 주5) Note 4) Resistor |
M 전류 센서 U 주6) Note 6) Current sensor |
||||||
SC검출회로 PWM신호 PWM Signal SC Detection Circuit |
구동회로 회생제동 Regenerative Brake Drive Circuit |
검출회로 U,V전류 U and V Current Detection Circuit |
구동회로 DB DB Drive Circuit |
검출회로 DC전압 DC Voltage Detection Circuit |
IGBT온도 검출회로 IGBT Temperatur Detection Circui |
Relay 구동회로 driving circuit |
검출회로 내부온도 Internal Temperature Detection Circuit |
e t |
IGBT
회생저항
W
V
B B+
E
PI
T1 T2
써미스터
단상 전원 AC380V~480V
Note 4) If using a DC reactor, connect the PO and PI pins.
Note 5) If the external regenerative resistor is used, after attaching internal resistor wiring to the
internal resistor fixing hole “NC” of the case, connect the external regenerative resistor to
B+ and B terminals.
Note 6) XDL-L7NHB050U ~ XDL-L7NHB075U models are cooled by a DC 24 V cooling fan.
Note 5)
Regenerative
Resistor
Thermistor
Single-phase power
2. Wiring and Connection
2-6
2.3.3 XDL-L7NH Drive Block Diagram (XDL-L7NHB150U)
1
2
3 4
6
8 9
7
2
3 4
6
8 9
7 1
Note 7) If using a DC reactor, connect the PO and PI pins.
Note 8) XDL-L7NHB150U model has no internal regenerative resistance. The external regenerative
resistance is used. When attaching the resistance, connect it to B+ and B terminals.
Note 9) XDL-L7NHB150U Model is cooled by a DC 24 V cooling fan.
Note 7) Note 8)
Note 9)
Resistor
3-phase power Input
Current sensor
Regenerative
Resistor
Thermistor
Thermistor
Control Power Phase
Loss Detection Circuit
Main Power Phase
Loss Detection
Circuit
Internal
Temperature
Detection Circuit driving circuit
DC Voltage
Detection Circuit
Regenerative
Brake Drive
Circuit
IGBT Temperature
Detection Circuit
PWM Signal SC
Detection Circuit
U and V Current
Detection Circuit
DB Drive Circuit
Single-phase Input
Main Control POWER circuit connection
U,V Current DC
Voltage
EtherCAT
Communication
USB
communication
A/D Conversion
Encoder Input
P/C Insulation I/F
Safety Function
Input (2 Points)
Safety Function
Output (1 Point)
Digital input
(8 points)
Digital Output
(4 points)
Analog (1 Point) |
Input |
Analog output
(2 points)
Safety device connection (STO) Input/output connection (I/O) Analog output connection
External
regenerative
resistor
2. Wiring and Connection
2-7
2.4 Power Supply Wiring
Ensure that the input power voltage is within the acceptable range.
Caution |
Overvoltages can damage the drive. |
If commercial power is connected to U, V, W terminals of Drive, they may be damaged. Be sure to
connect power to L1, L2, L3 terminals.
Connect short-circuit pins to the B and BI terminals. For external regenerative resistors, remove the
short-circuit pins and use standard resistors for the B+ and B terminals.
Model | Resistance | Standard Capacity |
* Notes |
XDL-L7NHB010U | 100[Ω] | Built-in 100 W | Caution For information about resistance during regenerative capacity expansion, refer to Section 2.4.3, "Regenerative Resistor Options.” |
XDL-L7NHB020U | 40[Ω] | Built-in 150 W | |
XDL-L7NHB035U | |||
XDL-L7NHB050U | 27[Ω] | Built-in 120 W | |
XDL-L7NHB075U | 27[Ω] | Built-in 240 W | |
XDL-L7NHB150U | 13.4[Ω] | External 2000 W |
Configure the system so that the main power (L1, L2, L3) is supplied after the control power (C1,
C2). (Refer to section 2.4.1, “Power Supply Wiring Diagram.”)
High voltages may remain in the device for sometime even after the main power is disconnected.
Please be careful.
Warnings |
After disconnecting the main power, ensure that the charge lamp is off before you start wiring. Failure to do so may result in electric shock. |
Always ground the device over the shortest possible distance. Long ground wires are susceptible to
noise which may cause the device to malfunction.
2. Wiring and Connection
2-8
2.4.1 Power Supply Wiring Diagram
Power Supply Wiring Diagram(XDL-L7NHB010U~ XDL-L7NHB035U)
UVW L1 L2 L3 C1 C2 B+ B BI 17 18 I/O PO PI |
1Ry 1SK 1MC |
RA Alarm Alarm+ 1Ry |
|
E 엔코더 Encoder |
|
외부 주2) Note 2) |
RA
1MC |
NF |
+2
4V
R S T 서보드라이브
AC 380~480[V]
Main
OFF
Main
ON
회생저항
주1)
DC 리액터
Note 1) It takes approximately one to two seconds until alarm signal is output after you turn on the
main power. Accordingly, push and hold the main power ON switch for at least two seconds.
Note 2) Short-circuit B and BI terminals before use, because XDL-L7NHB010U(100[W], 100[Ω]) and
XDL-L7NHB020U~ XDL-L7NHB035U(150[W], 40[Ω]) have internal regenerative resistance. If the
regenerative capacity is high because of frequent acceleration and deceleration, open the
short-circuit pins (B , BI) and connect an external regenerative resistor to B and B+.
Note 3) Remove approximately 7-10 ㎜ of the sheathing from the cables for the main circuit
power and attach crimp terminals. (Refer to Section 2.4.2, "Power Circuit Electrical
Components.”)
Note 4) Use a (-) flathead screwdriver to connect or remove the main circuit power unit wiring.
Note 1)
Servo Drive
DC reactor
External
regenerative
resistor
2. Wiring and Connection
2-9
Power Supply Wiring Diagram(XDL-L7NHB050U~ XDL-L7NHB075U)
Power Supply Wiring Diagram(XDL-L7NHB150U)
Note 1)
Servo Drive
DC reactor
Encoder
Note 6)External
regenerative
resistor
Note 1)
Servo Drive
DC reactor
Encoder
Note 7) External
regenerative
resistor
2. Wiring and Connection
2-10
Note 5) It takes approximately one to two seconds until alarm signal is output after you turn on the
main power. Accordingly, push and hold the main power ON switch for at least two seconds.
Note 6) Short-circuit B and BI terminals before use, because XDL-L7NHB050U(120[W], 27[Ω]),
XDL-L7NHB075U(240[W], 27[Ω]) have internal regenerative resistance. If the regenerative
capacity is high because of frequent acceleration and deceleration, attach the short-circuit
pins (B+, B) to NC terminal and connect an external regenerative resistor to B+ and B
before use.
Note 7) By default, use external regenerative resistance for XDL-L7NHB150U(2000[W], 13.4[Ω]), and
connect the resistance to B+ and B terminals before use.
Note 8) For the cables for the main circuit and control power unit, you must use crimp terminals
(XDL-L7NHB050U, XDL-L7NHB075U : GP110028_KET, XDL-L7NHB150U : GP110732_KET)
compliant with electrical components.
(Refer to Section 2.4.2, "Power Circuit Electrical Components.”)
XDL-L7NHB050U, XDL-L7NHB075U and XDL-L7NHB150U use terminal block, so use (+) and (-)
screwdrivers to connect or remove the terminals.
2. Wiring and Connection
2-11
2.4.2 Power Circuit Electrical Components
Name | XDL L7NHB010U |
XDL L7NHB020U |
XDL L7NHB035U |
XDL L7NHB050U |
XDL L7NHB075U |
XDL L7NHB150U |
MCCB | 30A Frame 10A (ABE33b/10) |
30A Frame 20A (ABE33b/20) |
30A Frame 30A (ABE33b/30) |
30A Frame 30A (ABE33b/30) |
50A Frame 50A (ABE53b/50) |
|
Noise Filter (NF) | TB6- B010LBEI (10A) |
TB6- B020NBDC (20A) |
TB6- B030NBDC (30A) |
TB6- B040A (40A) |
TB6- B060LA (60A) |
|
DC reactor | 10[A] | 20[A] | 30[A] | 30[A] | 50[A] | |
MC | 9A / 550V (GM□-12) |
18A / 550V (GM□-22) |
26A / 550V (GM□-40) |
26A / 550V (GM□-40) |
38A / 550V (GM□-50) |
|
Wire Note 1) |
L1, L2 ,L3, PO, PI, N B+, B, U, V, W |
AWG14 (2.08 ㎟) | AWG10 (5.5 ㎟) |
AWG10 (5.5 ㎟) |
AWG8 (8.0 ㎟) |
|
C1, C2 | AWG14 (2.08 ㎟) | |||||
Crimp terminal | UA-F4010, SEOIL (10mm Strip & Twist) |
GP110028 KET |
GP110028 KET |
GP110732 KET |
||
Regenerative Resistor (Default) |
100[W] 100Ω |
150[W] 40Ω | 120[W] 27Ω | 240[W] 27Ω | ||
Connector (Default) |
BLZ 7.62HP/3/180LR SN OR BX SO BLZ 7.62HP/11/180LR SN OR BX SO |
Note 1) When you select a wire, please use 600V, PVC-insulated wire.
To comply with UL(CSA) standards, use UL-certified wire (heat resistant temperature 75℃ or
above).
To comply with other standards, use proper wires that meet applicable standards.
For other special specifications, use wires equivalent or superior to those in this section.
2. Wiring and Connection
2-12
XDL-L7NHB010U
XDL-L7NHB020U / XDL-L7NHB035U
Wire strip
7~10[mm]
Weidmuller
SD 0.6x3.5x100
M4 : 1.2[N*m]
M4 : 1.2[N*m]
Weldmuller
SD 0.6x3.5x100
Wire strip
7~10[mm]
2. Wiring and Connection
2-13
For information on wiring to BLZ 7.62HP Series connector, refer to the above procedures.
1) Insert electric wire into insert hole with upper locking screw loosened, and use applicable flathead (-) driver
for each model to fully tighten screw to 0.4-0.5 N·m.
2) Otherwise, insufficient torque of locking screw may cause vibration-induced disconnection, system
malfunction and contact-induced fire accident.
3) After you connect a wire to connector, place the connector as closely to servo drive as possible and use
both locking hooks to fully lock it.
4) Use FG locking screw of M4 size (shown in bottom of product) to tighten it to 1.2 N·m.
5) Insufficient torque of locking screw may cause FG contact failure and even malfunctioning drive.
6) Recommended (-) driver: Use Weidmuller flathead driver (SD 0.6×3.5×100).
2. Wiring and Connection
2-14
XDL-L7NHB050U
1) Otherwise, insufficient torque of locking screw may cause vibration-induced disconnection, system malfunction
and contact-induced fire accident.
2) Use FG locking screw of M4 size (shown in bottom of product) to tighten it to 1.2 N·m.
TB1
L1 | L2 | L3 | B+ | B | U | V | W | FG | FG |
TB2
N | PO | P1 |
TB3
C1 | C2 |
Terminal screw: M4
Tightening torque: 1.2 N·m
Terminal screw: M4
Tightening torque: 1.2 N·m
Terminal screw: M4
Tightening torque: 1.2 N·m
TB3
TB2
TB1
NC : Internal Regenerative Resistor
Screw for Fixing Lead Terminal
Terminal signal
2. Wiring and Connection
2-15
XDL-L7NHB075U
1) Otherwise, insufficient torque of locking screw may cause vibration-induced disconnection, system malfunction
and contact-induced fire accident.
2) Use FG locking screw of M4 size (shown in bottom of product) to tighten it to 1.2 N·m.
Terminal signal
Terminal screw
Tightening torque
Terminal screw
Tightening torque
Terminal screw
Tightening torque
TB2
TB3
TB1
NC : Internal Regenerative Resistor
Screw for Fixing Lead Terminal
2. Wiring and Connection
2-16
XDL-L7NHB150U
1) Otherwise, insufficient torque of locking screw may cause vibration-induced disconnection, system malfunction
and contact-induced fire accident.
2) Use FG locking screw of M4 size (shown in bottom of product) to tighten it to 1.2 N·m.
TB1
L1 | L2 | L3 | N | PO | PI | B+ | B | U | V | W |
TB2
C1 | C2 |
FG
Terminal screw: M5
Tightening torque: 3.24 N·m
Terminal screw: M4
Tightening torque: 1.2 N·m
Terminal screw: M5
Tightening torque: 3.24 N·m
TB2
TB1
Terminal signal
2. Wiring and Connection
2-17
2.4.3 Regenerative Resistor Options
Category | Product Name |
Name | Applicable Drive |
Specifications |
Resistance | Braking resistance |
IRV300-82Ω 82[Ω] (300W) |
XDL L7NHB010U |
|
Resistance | Braking resistance |
IRV600- 140Ω 70Ω] (600W *2P) - Making under review |
XDL L7NHB020U / XDL L7NHB035U (2P) |
|
Resistance | Braking resistance |
IRV600-75Ω 25[Ω] (600W *3P) |
XDL L7NHB050U / XDL L7NHB075U (3P) |
|
Resistance | Braking resistance |
IRM2000- 13.4Ω 13.4[Ω] (2000W) |
XDL L7NHB150U |
2. Wiring and Connection
2-18
2.5 Wiring for Input/Output Signals
I/O Connector Specification : 10120-3000PE (3M)
Analog Monitoring Connector Specification : DF-11-4DS-2C (HIROSE)
2.5.1 Names and Functions of Digital Input/Output
Signals
Names and Functions of Digital Input Signals (I/O Connector)
Pin Number |
name | assignment | Details | Function |
6 | +24V | DC 24V | DC 24V INPUT |
COMMON |
11 | DI1 | POT | Forward (CCW) prohibited |
The actuator stops the servo motor to prevent it from moving beyond the motion range in forward direction. |
12 | DI2 | NOT | Reverse (CW) prohibited |
The actuator stops the servo motor to prevent it from moving beyond the motion range in reverse direction. |
7 | DI3 | HOME | Origin sensor | Connects the origin sensor to return to the origin. |
8 | DI4 | STOP | Servo stop | Stops the servo motor when the contact is on. |
2. Wiring and Connection
2-19
13 | DI5 | PCON | P control action |
When the contact is on, it converts the mode from PI control to P control. |
14 | DI6 | GAIN2 | Switch from Gain 1 to 2 |
When the contact is on, it switches the speed control gain 1 the gain 2 |
9 | DI7 | PCL | Forward torque limit |
When the contact is on, the forward torque limit function is activated. |
10 | DI8 | NCL | Negative torque limit |
When the contact is on, the negative torque limit function is activated. |
** PROBE1 | Touch probe 1 |
The probe signal to rapidly store the position value (1) |
||
** PROBE2 | Touch probe 2 |
The probe signal to rapidly store the position value (2) |
||
** EMG | Emergency stop |
Emergency stop when the contact is on. | ||
** ARST | Alarm reset | Resets the servo alarm. | ||
** LVSF1 | Vibration Suppression Filter 1 |
Depending on the Vibration Suppression Filter function setting(0x2515), using filter 1 signal |
||
** LVSF2 | Vibration Suppression Filter 2 |
Depending on the Vibration Suppression Filter function setting(0x2515), using filter 2 signal |
||
** SVON | Servo On | Servo On |
Note 1) **Signals not assigned by default as factory setting. The assignment may be changed by
parameter setting. For more information, refer to 「5.2 Input/Output Signals Setting.」
Note 2) Wiring can be also done by using COMMON (DC 24 V) of the input signal as the GND.
Names and Functions of Digital Output Signals
Pin Number |
Name | assignment | Details | Function |
1 | DO1+ | BRAKE+ | Brake | Outputs brake control signal. |
2 | DO1- | BRAKE- | ||
17 | DO2+ | ALARM+ | Servo alarm | Outputs signal when alarm occurs. |
18 | DO2- | ALARM- | ||
3 | DO3+ | RDY+ | Servo ready | This signal is output when the main power is established and the preparations for servo operation are complete. |
4 | DO3- | RDY- | ||
19 | DO4+ | ZSPD+ | Zero speed reached |
Outputs a signal when the current speed drops below the zero speed. |
20 | DO4- | ZSPD- | ||
** INPOS1 | Position reached 1 |
Outputs signal when having reached the command position (1) |
2. Wiring and Connection
2-20
** TLMT | Torque Limit | Outputs signal when the torque is limited. |
** VLMT | Speed limit | Outputs signal when the speed is limited. |
** INSPD | Speed reached |
Outputs signal upon reaching the command speed. |
** WARN | Servo warning |
Outputs signal when a warning occurs. |
** TGON | Rotation detection |
Outputs signal when the servo motor is rotating above the set value. |
** INPOS2 | Position reached 2 |
Outputs signal when having reached the command position (2) |
** Unassigned signals. The assignment may be changed by parameter setting. For more
information, refer to 「5.2 Input/Output Signals Setting.」
2.5.2 Names and Functions of Analog Input/Output
Signals
Names and Functions of Analog Input Signals (I/O Connector)
Pin Number |
Name | Details | Function |
15 | A-TLMT | Analog torque limit | It applies -10~+10V between A-TMLT(AI1) and AGND to limit motor output torque. Relationship between input voltage and limit torque depends on the value of [0x221C]. |
5 | AGND | AGND (0V) | Analog ground |
Names and Functions of Analog Output Signals (Analog Monitoring
Connector)
Pin Number |
Name | Details | Function |
1 | AMON1 | Analog Monitor 1 | Analog monitor output (-10V ~ +10) |
2 | AMON2 | Analog Monitor 2 | Analog monitor output (-10V ~ +10) |
3 | AGND | AGND (0V) | Analog ground |
4 | AGND | AGND (0V) | Analog ground |
Note 1) You can change the output variables to be monitored with analog monitor output by parameter
setting.
For more information, refer to 「5.2.3 Analog Monitor.」
2. Wiring and Connection
2-21
2. Wiring and Connection
2-22
2.5.3 Examples of Connecting Input/Output Signals
Examples of Connecting Digital Input Signals
Caution |
1. The input contact can be set to the contact A or the contact B, based on the characteristics of individual signal. 2. Each input contact can be assigned to 15 functions. 3. For more information on signal assignment and contact change of the input contact, refer to 5.2 Input/Output Signals Setting. 4. The rated voltage is DC 12 V to DC 24 V. R1 : 3.3KΩ, R2 : 680Ω Servo Drive Internal Circuit |
Example of Connecting Digital Output Signals
Caution |
1. The output contact can be set to the contact A or the contact B, based on the characteristics of individual signal. 2. Each output contact can be assigned to 11 output functions. 3. For more information on signal assignment and contact change of the output contact, refer to 5.2 Input/Output Signals Setting. 4. Overvoltages or overcurrents may damage the device because it uses an internal transistor switch. 5. The rated voltage and current are DC 24 V ± 10% and 120 [㎃]. |
Internal
Circuit
2. Wiring and Connection
2-23
Note 1) For DO1~ DO4 output signals, the GND24 terminal is separated.
Example of Connecting Analog Output Signals
Caution |
1. For more information on settings and scale adjustment of monitoring signals, refer to 5.2.3 Assignment of Analog output signals. 2. The range of analog output signals is -10V to 10V. 3. The resolution of analog output signal is 12 bits. 4. The maximum load current allowed is 2.5 [mA]. 5. The stabilization time is 15 [us]. Servo Drive |
Servo Drive
Internal
Circuit
Internal
Circuit
2. Wiring and Connection
2-24
2.5.4 Examples of Connecting Input/Output Signals
Note 1) The input signals DI1 - DI8 and output signals DO1 - DO4 are the factory default signals.
Digital Input | Digital Output |
Analog Input Safe function input |
Analog torque
limit
Safety function output
Analog Output
2. Wiring and Connection
2-25
2.6 Wiring of Encoder Signal (ENCODER)
ENCODER Connector Specification: 10114-3000VE (3M)
2.6.1 Quadrature Encoder Signaling Unit Wiring
APCS-EAS Cable
Encoder |
Servo Motor Servo Drive
2. Wiring and Connection
2-26
APCS-EBS Cable
2.6.2 Serial Encoder Signaling Unit Wiring
APCS-ECS Cable
Servo Motor Servo Drive
Encoder |
Servo Motor Servo Drive
Encoder |
2. Wiring and Connection
2-27
APCS-EDS Cable
APCS-EES Cable
Servo Motor
Encoder |
Servo Drive
Servo Motor
Encoder |
Servo Drive
2. Wiring and Connection
2-28
2.6.3 Multi-Turn Encoder Signaling Unit Wiring
APCS-ECS1 Cable
APCS-EDS1 Cable
Servo Motor
Encoder |
Servo Drive
Servo Motor
Encoder |
Servo Drive
2. Wiring and Connection
2-29
APCS-EES1 Cable
2.6.4 Tamagawa Encoder Signaling Unit Wiring
Servo Motor
Encoder |
Servo Drive
Servo Motor
Encoder |
Servo Drive
2. Wiring and Connection
2-30
2.6.5 EnDat 2.2 Encoder Signaling Unit Wiring
Servo Motor
Encoder |
Servo Drive
2. Wiring and Connection
2-31
2.7 Wiring for Safety Function Signals (STO)
2069577-1(Tyco Electronics)
2.7.1 Names and Functions of Safety Function Signals
Pin Number |
name | Function |
1 | +12V | For bypass wiring |
2 | -12V | |
3 | STO1- | DC 24 V GND |
4 | STO1+ | Blocks the current (torque) applied to the motor when the signal is off. |
5 | STO2- | DC 24 V GND |
6 | STO2+ | Blocks the current (torque) applied to the motor when the signal is off. |
7 | EDM+ | Monitor output signal for checking the status of safety function input signal |
8 | EDM- |
2 1
4 3
6 5
8 7
2. Wiring and Connection
2-32
2.7.2 Example of Connecting Safety Function Signals
Caution |
1. The rated voltage is DC 12 V to DC 24 V. 2. With the contacts of STO1 and STO2 off, the motor output current is blocked. 24 V power |
Safety Module
Driving signal
Blocking
Blocking
2. Wiring and Connection
2-33
2.7.3 Bypass Wiring of Safety Function Signal
This drive provides the Mini I/O Bypass connector which has Bypass wiring to be used for the
convenience of the user when the STO function is not used. To use the Bypass function, connect the
Mini I/O Plug connector as follows.
If you connect +12V to STO2-, -12V to STO1+ and STO1- to STO2+ for wiring of the Mini I/O Plug
connector, you can bypass the safety function signal. Never use this power (+12V,-12V) except for this
purpose.
Mini I/O By-pass Connector
1971153-1(Tyco Electronics)
Mini I/O Plug Connector
2069577-1(Tyco Electronics)
2. Wiring and Connection
2-34
2.8 Wiring for EtherCAT Communication Signals
2.8.1 Names and Functions of EtherCAT
Communication Signals
EtherCAT IN and EtherCAT OUT Connector
Pin Number |
Signal Name | Line color |
1 | TX/RX0 + | White/Orange |
2 | TX/RX0 - | Orange |
3 | TX/RX1+ | White/Green |
4 | TX/RX2 - | Blue |
5 | TX/RX2 + | White/Blue |
6 | TX/RX1 - | Green |
7 | TX/RX3 + | White/Brown |
8 | TX/RX3 - | Brown |
Plate | Shield |
Note 1) EtherCAT only uses signals from No. 1, 2, 3, and 6.
2. Wiring and Connection
2-35
2.8.2 Example of Drive Connection
The following figure shows the connection between a master and slave using EtherCAT communication.
This is an example of a connection by topology of basic line type.
For an environment with much noise, install ferrite core at both ends of the EtherCAT cable.
3. EtherCAT Communication
3-1
3. EtherCAT Communication
EtherCAT stands for Ethernet for Control Automation Technology. It is a communication method for
masters and slaves which uses Real-Time Ethernet, developed by the German company BECKHOff
and managed by the EtherCAT Technology Group (ETG).
The basic concept of the EtherCAT communication is that, when a DataFrame sent from a master
passes through a slave, the slave inputs the received data to the DataFrame as soon as it receives the
data.
EtherCAT uses a standard Ethernet frame compliant with IEEE802.3. Based on the Ethernet of
100BASE-TX, therefore, the cable can be extended up to 100 m, and up to 65,535 nodes can be
connected. In addition to this, when using a separate Ethernet switch, you can interconnect it to
common TCP/IP.
3.1 Structure of CANopen over EtherCAT
This drive supports a CiA 402 drive profile. The Object Dictionary in the application layer includes
application data and PDO (Process Data Object) mapping information from the process data interface
and application data.
The PDO can be freely mapped, and the content of the process data is defined by PDO mapping.
The data mapped to the PDO is periodically exchanged (read and written) between an upper level
controller and a slave by process data communication; the mailbox communication is not performed
periodically; and all of the parameters defined in the Object Dictionary are accessible.
3. EtherCAT Communication
3-2
3.1.1 EtherCAT State Machine
The EtherCAT drive has 5 states as above, and a state transition is done by an upper level controller
(master).
State | Details |
Boot | A state for firmware update. Only mailbox communication using the FoE (File access over EtherCAT) protocol is available. The drive can transit to the Boot state only when in the Init state. |
Init | Initializes the communication state. Unable to perform mailbox or process data communication. |
Pre-Operational | Mailbox communication is possible. |
Safe Operational |
Mailbox communication is possible and PDO can be transmitted. PDO can not be received. The process data of the drive can be passed to an upper level controller. |
Operational | Mailbox communication is possible and PDO can be transmitted and received. The process data can be properly exchanged between the drive and the upper level controller, so the drive can be normally operated. |
3. EtherCAT Communication
3-3
3.2 Status LED
The LEDs on the EtherCAT ports of this drive indicate the states of the EtherCAT communications and
errors, as shown in the following figure. There are 3 green LEDs, which are L/A0, L/A1, and RUN, and
1 red ERR LED.
L/A0, L/A1 (Link Activity) LED
The L/A0 LED and L/A1 LED indicate the status of the EtherCAT IN and EtherCAT OUT communication
ports, respectively. The following table outlines what each LED state indicates.
LED status | Description |
OFF | Not connected for communication. |
Flickering | Connected, and communication is enabled. |
ON | Connected, but communication is disabled. |
L/A 0 L/A 1 RUN 0 1 2 3 4 5 6 8 9 7 2 3 4 5 6 8 9 7 0 1 |
ERR x10 x1 |
3. EtherCAT Communication
3-4
RUN LED
The RUN LED indicates in which status the drive is in the EtherCAT State Machine.
LED status | Description |
OFF | The drive is in the Init state. |
Blinking | The drive is in the Pre-Operational state. |
Single Flash | The drive is in the Safe-Operational state. |
ON | The drive is in the Operational state. |
ERR LED
The ERR LED indicates the error status of the EtherCAT communication. The following table outlines
what each LED state indicates:
LED status | Description |
OFF | Indicates normal state of the EtherCAT communication without any error. |
Blinking | Indicates that the drive has received a command from the EtherCAT master, instructing it to perform a setting which is not feasible in the present state or to perform an impossible state transition. |
Single Flash | A DC PLL Sync error occurred. |
Double Flash | A Sync Manager Watchdog error occurred. |
ON | A servo alarm of the drive occurred. |
3. EtherCAT Communication
3-5
3.3 Data Type
The following table outlines the type and range of the data types used in this manual.
Codes | Description | Range |
SINT | Signed 8bit | -128 ~127 |
USINT | Unsigned 8bit | 0 ~ 255 |
INT | Signed 16bit | -32768 ~ 32767 |
UINT | Unsigned 16bit | 0 ~ 65535 |
DINT | Signed 32bit | -2147483648 ~ 2147483647 |
UDINT | Unsigned 32bit | 0 ~ 4294967295 |
FP32 | Float 32bit | Single precision floating point |
STRING | String Value |
3.4 PDO assignment
The EtherCAT uses the Process Data Object (PDO) to perform real-time data transfers. There are two
types of PDOs: RxPDO receives data transferred from the upper level controller, and TxPDO sends the
data from the drive to the upper level controller.
This drive uses the objects of 0x1600 to 0x1603 and 0x1A00 to 0x1A03 to assign the RxPDO and the
TxPDO, respectively. Up to 10 objects can be assigned to each PDO. You can check the PDO
assignment attribute of each object to see if it can be assigned to the PDO.
The diagram below shows the PDO assignment:
This is an example when assigning the Controlword and the Target Position with the RxPDO (0x1600).
Index | SubIndex | Name | Data Type |
0x6040 | 0x00 | Controlword | UINT |
0x607A | 0x00 | Target Position | DINT |
The setting values of the RxPDO (0x1600) are as follows:
Upper level controller |
Servo Drive |
3. EtherCAT Communication
3-6
SubIndex | Setting values | ||
0 | 0x02 (2 values assigned) | ||
Bit 31~16(Index) | Bit 15~8(Sub index) | Bit 7~0(Bit size) | |
1 | 0x6040 | 0x00 | 0x10 |
2 | 0x607A | 0x00 | 0x20 |
This is an example to assign the Statusword, the Actual Position Value, and the Actual Velocity Value
with the TxPDO (0x1A00).
Index | SubIndex | Name | Data Type |
0x6041 | 0x00 | Statusword | UINT |
0x6064 | 0x00 | Actual Position Value | DINT |
0x606C | 0x00 | Velocity Actual Value | DINT |
The setting values of the TxPDO (0x1A00) are as follows:
SubIndex | Setting values | ||
0 | 0x03 (3 values assigned) | ||
Bit 31~16(Index) | Bit 15~8(Sub index) | Bit 7~0(Bit size) | |
1 | 0x6041 | 0x00 | 0x10 |
2 | 0x6064 | 0x00 | 0x20 |
3 | 0x606C | 0x00 | 0x20 |
The Sync Manager can be composed of multiple PDOs. The Sync Manager PDO Assign Object
(RxPDO:0x1C12, TxPDO:0x1C13) indicates the relationship between the SyncManager and the PDO.
The following figure shows an example of the SyncManager PDO mapping:
3. EtherCAT Communication
3-7
PDO Mapping
The following tables list the PDO mappings set by default. These settings are defined in the EtherCAT
Slave Information file (XML file).
1st PDO Mapping:
2nd PDO Mapping:
3rd PDO Mapping:
4th PDO Mapping:
Target torque | Target position |
Modes of Operation |
Touch Probe Function |
|||||
Actual code value |
Position actual value |
Following error actual value |
Digital input | Operation Mode Display |
Command Speed |
Drive speed | Touch probe status | Touch probe 1 positive position value |
Touch probe 1 positive position value |
Position actual value |
Following error actual value |
Touch probe status |
Digital input |
Target | Touch Probe Function | Digital output |
Touch probe 1 positive position value |
Position actual value |
Touch probe status |
Digital input |
Touch Probe Function |
Digital output | Target velocity |
Touch probe 1 positive position value |
Position actual value |
Touch probe status |
Digital input |
Touch Probe Function |
Digital output Digital output |
Target torque |
3. EtherCAT Communication
3-8
3.5 Synchronization Using the DC (Distributed
Clock)
The Distributed Clock (DC) synchronizes EtherCAT communication. The master and slave share a
reference clock (system time) for synchronization, and the slave synchronizes its applications with the
Sync0 event generated by the reference clock.
The following synchronization modes exist in this drive. You can change the mode with the sync control
register.
(1) Free-run Mode:
In free-run mode, it operates each cycle independent of the communication cycle and master cycle.
(2) DC Synchronous Mode:
DC Synchronous mode, the Sync0 event from the EtherCAT master synchronizes the drive. Please use
this mode for more precise synchronous control
3. EtherCAT Communication
3-9
3.6 Emergency Messages
Emergency messages are passed to the master via mailbox communication when a servo alarm
occurs in the drive. Emergency messages may not be sent in the event of communication failure.
Emergency messages consist of 8-byte data.
Byte | 0 | 1 | 2 | 3 | 4 | 5 | 6 | 7 |
Details | Emergency error code (0xFF00) |
Error Register (0x1001) |
Reserved | Unique field for each manufacturer | ||||
Servo alarm code | Reserved |
4. CiA402 Drive Profile
4-1
4. CiA402 Drive Profile
4.1 State machine
State | Description |
Not ready to switch on | Reset is in progress by control power on. |
Switch on disabled | Initialization completed, but the main power cannot be turned on. |
Ready to switch on | The main power can be turned on and the drive function is disabled. |
Switched on | The main power is turned on and the drive function is disabled. |
Operation enabled | The drive function is enabled, and the servo is on. |
Quick Stop active | Quick stop function is in operation. |
Fault reaction active | A servo alarm occurred, causing a relevant sequence to be processed. |
Fault | Servo alarm is activated. |
Additional state State to be changed by the slave State which can be checked by the master |
The control power is on; the
main power can be turned on.
The control and main powers are on;
torque cannot be applied to the motor.
Torque can be applied to the motor.
4. CiA402 Drive Profile
4-2
State Machine Control Commands
Switching states of the State Machine can be done through combinations of Controlword (0x6040) bits
setting, as described in the table below:
Command | bits of the Controlword (0x6040) | State Machine switching |
||||
Bit 7 | Bit 3 | Bit 2 | Bit 1 | Bit 0 | ||
Shutdown | x | x | 1 | 1 | 0 | 2, 6, 8 |
Switch on | x | 0 | 1 | 1 | 1 | 3 |
Switch on + Enable operation |
x | 1 | 1 | 1 | 1 | 3 + 4 |
Disable voltage | x | x | x | 0 | x | 7, 9, 10,12 |
Quick stop | x | x | 0 | 1 | x | 7, 10,11 |
Disable operation | x | 0 | 1 | 1 | 1 | 5 |
Enable operation | x | 1 | 1 | 1 | 1 | 4, 16 |
Fault reset | 0 → 1 | x | x | x | x | 15 |
Statusword Bit Names (0x6041)
You can check the state of the State Machine through bit combinations of the Statusword (0x6041), as
described in the table below:
Command | bits of the Statusword (0x6041) | ||||||
Bit 6 | Bit 5 | Bit 4 | Bit 3 | Bit 2 | Bit 1 | Bit 0 | |
Not ready to switch on | 0 | 0 | x | 0 | 0 | 0 | 0 |
Switch on disabled | 1 | 1 | x | 0 | 0 | 0 | 0 |
Ready to switch on | 0 | 1 | x | 0 | 0 | 0 | 1 |
Switched on | 0 | 1 | x | 0 | 0 | 1 | 1 |
Operation enabled | 0 | 1 | x | 0 | 1 | 1 | 1 |
Fault reaction active | 0 | 1 | x | 1 | 1 | 1 | 1 |
Fault | 0 | 1 | x | 1 | 0 | 0 | 0 |
Bit No. | Data Description | Note |
0 | Ready to switch on | For more information, refer to 9.3 CiA402 Objects. |
1 | Switched on | |
2 | Operation enabled | |
3 | Fault | |
4 | Voltage enabled | |
5 | Quick stop |
4. CiA402 Drive Profile
4-3
6 | Switched on disabled |
7 | Warning |
8 | - |
9 | Remote |
10 | Target reached |
11 | Internal limit active |
12 | Operation mode specific |
13 | |
14 | Torque limit active |
15 | Drive specific |
4.2 Operation Modes
This drive supports the following operation modes (0x6060):
Profile Position Mode(PP)
Homing Mode(HM)
Profile Velocity Mode(PV)
Profile Torque Mode(PT)
Cyclic Synchronous Position Mode(CSP)
Cyclic Synchronous Velocity Mode(CSV)
Cyclic Synchronous Torque Mode(CST)
Drive functions supported for each mode are listed in the table below:
Function | Operation Modes | |||
CSP PP |
CSV PV |
CST PT |
HM | |
Electric Gear | O | O | O | O |
Speed feedforward |
O | X | X | OX |
Torque feedforward |
O | O | X | O |
Position command filter |
O | X | X | OX |
Real-time gain adjustment |
O | O | O | O |
Notch filter | O | O | O | O |
Disturbance observer |
O | O | X | O |
4. CiA402 Drive Profile
4-4
Note 1) For the HM mode, the control mode is internally switched; thus, the function of speed feedforward
and/or position command filter may be applied or not, depending on the operation condition.
Related Objects
Index | Sub Index |
Name | Variable type | Accessibility | assignment PDO | Unit |
0x6060 | - | Modes of Operation | SNIT | RW | Yes | - |
0x6061 | - | Modes of Operation Display | SNIT | RO | Yes | - |
0x6502 | - | Supported Drive Modes | UDINT | RO | No | - |
4. CiA402 Drive Profile
4-5
4.3 Position Control Modes
4.3.1 Cyclic Synchronous Position Mode
The Cyclic Synchronous Position (CSP) mode receives the target position (0x607A), renewed at every
PDO update cycle, from the upper level controller, to control the position.
In this mode, the controller is able to calculate the velocity offset (0x60B1) and the torque offset
(0x60B2) corresponding the speed and torque feedforwards respectively, and pass them to the drive.
The block diagram of the CSP mode is as follows:
4. CiA402 Drive Profile
4-6
Related Objects
Index | Sub Index |
Name | Variable type | Accessibility | assignment PDO | Unit |
0x6040 | - | Controlword | UINT | RW | Yes | - |
0x6041 | - | Statusword | UINT | RO | Yes | - |
0x607A | - | Target Position | DINT | RW | Yes | UU |
0x607D | - | Software Position Limit | - | - | - | - |
0 | Number of entries | USINT | RO | No | - | |
1 | Min position limit | DINT | RW | No | UU | |
2 | Max position limit | DINT | RW | No | UU | |
0x6084 | - | Profile Deceleration | UDINT | RW | No | UU/s2 |
0x6085 | - | Quick Stop Deceleration | UDINT | RW | No | UU/s2 |
0x60B0 | - | Position Offset | DINT | RW | Yes | UU |
0x60B1 | - | Velocity Offset | DINT | RW | Yes | UU/s |
0x60B2 | - | Torque Offset | INT | RW | Yes | 0.1% |
0x6062 | - | Position Demand Value | DINT | RO | Yes | UU |
0x60FC | - | Position Demand Internal Value | DINT | RO | Yes | pulse |
0x606C | - | Velocity Actual Value | DINT | RO | Yes | UU/s |
0x606D | - | Velocity Window | UINT | RW | No | UU/s |
0x606E | - | Velocity Window Time | UINT | RW | No | ms |
0x6077 | - | Torque Actual Value | INT | RO | Yes | 0.1% |
0x606C | - | Velocity Actual Value | DINT | RO | Yes | UU/s |
0x6064 | - | Position Actual Value | DINT | RO | Yes | UU |
0x6063 | - | Position Actual Internal Value | DINT | RO | Yes | pulse |
4. CiA402 Drive Profile
4-7
Internal Block Diagram of CSP Mode
4. CiA402 Drive Profile
4-8
4.3.2 Profile Position Mode
Unlike the CSP mode receiving the target position, renewed at every PDO update cycle, from the upper
level controller, in the Profile Position (PP) mode, the drive generates a position profile internally to
operate up to the target position (0x607A) using the profile velocity (0x6081), acceleration (0x6083),
and deceleration (0x6084).
The block diagram of the PP mode is as follows:
Related Objects
Index | Sub Index |
Name | Variable type | Accessibility | assignment PDO | Unit |
0x6040 | - | Controlword | UINT | RW | Yes | - |
0x6041 | - | Statusword | UINT | RO | Yes | - |
0x607A | - | Target Position | DINT | RW | Yes | UU |
0x607D | - | Software Position Limit | - | - | - | - |
0 | Number of entries | USINT | RO | No | - | |
1 | Min position limit | DINT | RW | No | UU |
4. CiA402 Drive Profile
4-9
2 | Max position limit | DINT | RW | No | UU | |
0x607F | - | Maximum Profile Velocity | UDINT | RW | Yes | UU/s |
0x6081 | - | Profile Velocity | UDINT | RW | No | UU/s |
0x6083 | - | Profile Acceleration | UDINT | RW | No | UU/s2 |
0x6084 | - | Profile Deceleration | UDINT | RW | No | UU/s2 |
0x6085 | - | Quick Stop Deceleration | UDINT | RW | No | UU/s2 |
0x60B1 | - | Velocity Offset | DINT | RW | Yes | UU/s |
0x60B2 | - | Torque Offset | INT | RW | Yes | 0.1% |
0x6062 | - | Position Demand Value | DINT | RO | Yes | UU |
0x60FC | - | Position Demand Internal Value | DINT | RO | Yes | pulse |
0x606C | - | Velocity Actual Value | DINT | RO | Yes | UU/s |
0x606D | - | Velocity Window | UINT | RW | No | UU/s |
0x606E | - | Velocity Window Time | UINT | RW | No | ms |
0x6077 | - | Torque Actual Value | INT | RO | Yes | 0.1% |
0x606C | - | Velocity Actual Value | DINT | RO | Yes | UU/s |
0x6064 | - | Position Actual Value | DINT | RO | Yes | UU |
0x6063 | - | Position Actual Internal Value | DINT | RO | Yes | pulse |
4. CiA402 Drive Profile
4-10
Internal Block Diagram of PP Mode
4. CiA402 Drive Profile
4-11
You can use the following three position commands in Profile Position Mode:
Single set point
After reaching the target position, the drive sends a completion signal to the upper level controller
and receives a new command.
Change immediately
After receiving a new position command while driving to the target position, it drives to the new
position regardless of the existing target position.
Set of Set point
After receiving a new position command while driving to the target position, it subsequently drives
to the new target position after driving to the existing target position.
The three methods mentioned above can be set by a combination of the New setpoint bit (Controlword,
0x6040.4), the Change set immediately bit (Controlword, 0x6040.5), and the Change setpoint bit
(Controlword, 0x6040.9).
Single Set Point Driving Procedure
(1) Specify the target position (0x607A).
(2) Set the New setpoint bit to 1 and the Change set immediately bit to 0 to request the position
operation.
(3) The drive notifies the operator of its arrival at the target position with the Target reached bit
(Statusword, 0x6041.10). The drive can suspend where it is or perform a new position operation if
it receives the New set point bit.
4. CiA402 Drive Profile
4-12
Change Immediately Driving Procedure
(1) Specify the target position (0x607A).
(2) Set the New setpoint bit to 1 and the Change set immediately bit to 1 to request the position
operation.
(3) You can begin a new position operation (New setpoint) regardless of the previous target position.
The drive immediately moves to the new position.
(4) The drive notifies the operator of its arrival at the target position with the Target reached bit
(Statusword, 0x6041.10).
Set of Set Point Driving Procedure
(1) Specify the target position (0x607A).
(2) Set the New setpoint bit to 1 and the Change of Set point bit to 1 to request the position operation.
(3) After reaching the previous target position, the drive begins to move to the new position (New
setpoint).
(4) The drive notifies the operator of its arrival at the target position with the Target reached bit
(Statusword, 0x6041.10).
4. CiA402 Drive Profile
4-13
4.4 Velocity Control Mode
4.4.1 Cyclic Synchronous Velocity Mode
The Cyclic Synchronous Velocity (CSV) mode receives the target velocity (0x60FF), renewed at every
PDO update cycle, from the upper level controller, to control the velocity.
This mode allows the upper level controller to calculate the torque offset (0x60B2) corresponding the
torque feedforward and pass it to the drive.
The block diagram of the CSV mode is as follows:
Related Objects
Index | Sub Index |
Name | Variable type | Accessibility | assignment PDO | Unit |
0x6040 | - | Controlword | UINT | RW | Yes | - |
0x6041 | - | Statusword | UINT | RO | Yes | - |
0x60FF | - | Target Velocity | DINT | RW | Yes | UU/s |
0x6084 | - | Profile Deceleration | UDINT | RW | No | UU/s2 |
0x6085 | - | Quick Stop Deceleration | UDINT | RW | No | UU/s2 |
0x60B1 | - | Velocity Offset | DINT | RW | Yes | UU/s |
0x60B2 | - | Torque Offset | INT | RW | Yes | 0.1% |
0x606B | - | Velocity Demand Value | DINT | RO | Yes | UU |
0x606C | - | Velocity Actual Value | DINT | RO | Yes | UU/s |
4. CiA402 Drive Profile
4-14
0x606D | - | Velocity Window | UINT | RW | No | UU/s |
0x606E | - | Velocity Window Time | UINT | RW | No | ms |
0x6077 | - | Torque Actual Value | INT | RO | Yes | 0.1% |
0x606C | - | Velocity Actual Value | DINT | RO | Yes | UU/s |
0x6064 | - | Position Actual Value | DINT | RO | Yes | UU |
0x6063 | - | Position Actual Internal Value | DINT | RO | Yes | pulse |
4. CiA402 Drive Profile
4-15
Internal Block Diagram of CSV Mode
0x60B1
Velocity Offset
[UU/s]
0x6085
Quick Stop Dec.
[UU/s^2]
Interpolate Velocity Command |
0x606B
Velocity Demand
Value [UU/s]
Processing Acc./Dec. Speed Command |
Acc. Time 0x2301
Dec. Time 0x2302
0x605A
Quick Stop
Option Code
Gear Ratio
Inverse
0x60BB or 0x60BD
Touch Probe 1/2
Negative Edge
Position Value[UU]
Gear Ratio |
0x6091:01
0x6091:02
Motor
Shaft
0x60BA or 0x60BC
Touch Probe 1/2
Positive Edge
Position Value[UU]
0x6064
Position Actual
Value [UU]
0x6063
Position Internal
Actual Value [pulse]
0x60FF
Target Velocity
[UU/s]
S-curve Time 0x2303
Torque Feed-Forward |
P/PI Gain Conversion |
Gain
Filter
0x210E
0x210F
Speed Control 0x2106 1 2 0x2107 |
0x2102
0x2103
P Gain I Gain
0x2114 0x2115 P/PI Mode Torque Speed 0x2116 Acc. 0x2117 Following 0x2118 Error |
Disturbance Observer |
Gain
Filter
0x2512
0x2513
Speed Feedback Filter |
Gear Ratio |
Inverse 0x606C Velocity Actual Value [UU/s] |
Time 0x210B
Notch Filter 0x2507 0x250A 3 4 0x2508 0x250B 0x2504 2 0x2505 0x2509 0x250C 0x2506 |
0x2501
1 0x2502
0x2503
Frequency Width Depth
Adaptive Filter 0x2500
function Select
Torque Command Filter 0x2104 0x2108 1 2 |
Torque Limit Select Positive Negative Max. 0x2110 0x60E0 0x60E1 0x6072 |
0x6074 Torque Demand Value [0.1%] |
Ext. Positive
Ext. Negative
Velocity Calulation |
Current Control |
Gain 0x2514
0x6077
Torque Actual
Value [0.1%]
Positon
Calulation
0x2111
0x2112
Gain Conversion
0x2119
0x211A
Mode
Time1
Time2 0x211B
Waiting 0x211C
Time1
Waiting 0x211D
Time2
Servo-Lock Function |
Select 0x2311
0x60B2
Torque Offset
[0.1%]
Velocity Limit Function |
4. CiA402 Drive Profile
4-16
4.4.2 Profile Velocity Mode
Unlike the CSV mode receiving the target velocity, renewed at every PDO update cycle, from the upper
level controller, in the Profile Velocity (PV) mode, the drive generates a velocity profile internally up to
the target velocity (0x60FF) using the profile acceleration (0x6083) and deceleration (0x6084), in order
to control its velocity.
At this moment, the max. profile velocity (0x607F) limits the maximum velocity.
The block diagram of the PV mode is as follows:
4. CiA402 Drive Profile
4-17
Related Objects
Index | Sub Index |
Name | Variable type | Accessibility | assignment PDO | Unit |
0x6040 | - | Controlword | UINT | RW | Yes | - |
0x6041 | - | Statusword | UINT | RO | Yes | - |
0x60FF | - | Target Velocity | DINT | RW | Yes | UU/s |
0x607F | - | Maximum Profile Velocity | UDINT | RW | Yes | UU/s |
0x6083 | - | Profile Acceleration | UDINT | RW | No | UU/s2 |
0x6084 | - | Profile Deceleration | UDINT | RW | No | UU/s2 |
0x6085 | - | Quick Stop Deceleration | UDINT | RW | No | UU/s2 |
0x605A | - | Quick Stop Option Code | INT | RW | No | - |
0x60B1 | - | Velocity Offset | DINT | RW | Yes | UU/s |
0x60B2 | - | Torque Offset | INT | RW | Yes | 0.1% |
0x606B | - | Velocity Demand Value | DINT | RO | Yes | UU/s |
0x606C | - | Velocity Actual Value | DINT | RO | Yes | UU/s |
0x606D | - | Velocity Window | UINT | RW | No | UU/s |
0x606E | - | Velocity Window Time | UINT | RW | No | ms |
0x6077 | - | Torque Actual Value | INT | RO | Yes | 0.1% |
0x606C | - | Velocity Actual Value | DINT | RO | Yes | UU/s |
0x6064 | - | Position Actual Value | DINT | RO | Yes | UU |
0x6063 | - | Position Actual Internal Value | DINT | RO | Yes | pulse |
4. CiA402 Drive Profile
4-18
Internal Block Diagram of PV Mode
4. CiA402 Drive Profile
4-19
4.5 Torque Control Modes
4.5.1 Cyclic Synchronous Torque Mode
The Cyclic Synchronous Torque (CST) mode receives the target torque (0x6071), renewed at every
PDO update cycle, from the upper level controller, to control the torque.
This mode allows the upper level controller to calculate the torque offset (0x60B2) corresponding the
torque feedforward and pass it to the drive.
The block diagram of the CST mode is as follows:
Related Objects
Index | Sub Index |
Name | Variable type | Accessibility | assignment PDO | Unit |
0x6040 | - | Controlword | UINT | RW | Yes | - |
0x6041 | - | Statusword | UINT | RO | Yes | - |
0x6071 | - | Target Velocity | INT | RW | Yes | 0.1% |
0x6072 | - | Maximum Torque | UINT | RW | Yes | 0.1% |
0x607F | - | Maximum Profile Velocity | UDINT | RW | Yes | UU/s |
0x60E0 | - | Positive Torque Limit Value | UINT | RW | Yes | 0.1% |
0x60E1 | - | Negative Torque Limit Value | UINT | RW | Yes | 0.1% |
0x60B2 | - | Torque Offset | INT | RW | Yes | 0.1% |
4. CiA402 Drive Profile
4-20
0x6074 | - | Torque Demand Value | INT | RO | Yes | 0.1% |
0x606C | - | Velocity Actual Value | DINT | RO | Yes | UU/s |
0x606D | - | Velocity Window | UINT | RW | No | UU/s |
0x606E | - | Velocity Window Time | UINT | RW | No | ms |
0x6077 | - | Torque Actual Value | INT | RO | Yes | 0.1% |
0x606C | - | Velocity Actual Value | DINT | RO | Yes | UU/s |
0x6064 | - | Position Actual Value | DINT | RO | Yes | UU |
0x6063 | - | Position Actual Internal Value | DINT | RO | Yes | pulse |
Internal Block Diagram of CST Mode
4. CiA402 Drive Profile
4-21
4.5.2 Profile Torque Mode
Unlike the CST mode receiving the target torque, renewed at every PDO update cycle, from the upper
level controller, in the Profile Torque (PT) mode, the drive generates a torque profile internally up to the
target torque (0x6071) by the torque slope (0x6087), in order to control its torque.
At this moment, the torque applied to the motor is limited depending on the Positive/Negative Torque
Limit Value (0x60E0 and 0x60E1) and the Maximum Torque (0x6072) based on its driving direction.
The block diagram of the PT mode is as follows:
Related Objects
Index | Sub Index |
Name | Variable type | Accessibility | assignment PDO | Unit |
0x6040 | - | Controlword | UINT | RW | Yes | - |
0x6041 | - | Statusword | UINT | RO | Yes | - |
0x6071 | - | Target Velocity | INT | RW | Yes | 0.1% |
0x6072 | - | Maximum Torque | UINT | RW | Yes | 0.1% |
0x607F | - | Maximum Profile Velocity | UDINT | RW | Yes | UU/s |
0x6087 | - | Torque Slope | UDINT | RW | Yes | 0.1%/s |
0x60E0 | - | Positive Torque Limit Value | UINT | RW | Yes | 0.1% |
0x60E1 | - | Negative Torque Limit Value | UINT | RW | Yes | 0.1% |
0x60B2 | - | Torque Offset | INT | RW | Yes | 0.1% |
0x6074 | - | Torque Demand Value | INT | RO | Yes | 0.1% |
0x606C | - | Velocity Actual Value | DINT | RO | Yes | UU/s |
0x606D | - | Velocity Window | UINT | RW | No | UU/s |
4. CiA402 Drive Profile
4-22
0x606E | - | Velocity Window Time | UINT | RW | No | ms |
0x6077 | - | Torque Actual Value | INT | RO | Yes | 0.1% |
0x606C | - | Velocity Actual Value | DINT | RO | Yes | UU/s |
0x6064 | - | Position Actual Value | DINT | RO | Yes | UU |
0x6063 | - | Position Actual Internal Value | DINT | RO | Yes | pulse |
Internal Block Diagram of PT Mode
4. CiA402 Drive Profile
4-23
4.6 Homing
This drive provides its own homing function. The figure below represents the relationship between the
input and output parameters for the homing mode. You can specify the speed, acceleration, offset, and
homing method.
As shown in the figure below, you can set the offset between the home position and the zero position of
the machine using the home offset. The zero position indicates a point whose Actual Position Value
(0x6064) is zero (0).
Homing Method
Homing Speeds
Homing Acceleration
Home Offset
Position demand internal value (0x60 or position demand value (0x6062) |
4. CiA402 Drive Profile
4-24
4.6.1 Homing Method
The drive supports the following homing methods (0x6098):
Homing Method (0x6098) |
Details |
1 | The drive returns to the home position with the negative limit switch (NOT) and the Index (Z) pulse while driving in the reverse direction. |
2 | The drive returns to the home position with the positive limit switch (POT) and the Index (Z) pulse while driving in the forward direction. |
7,8,9,10 | The drive returns to the home position with the home switch (HOME) and the Index (Z) pulse while driving in the forward direction. When the positive limit switch (POT) is input during homing, the drive will switch its driving direction. |
11,12,13,14 | The drive returns to the home position with the home switch (HOME) and the Index (Z) pulse while driving in the reverse direction. When the negative limit switch (NOT) is input during homing, the drive will switch its driving direction. |
24 | The drive returns to the home position with the home switch (HOME) while driving in the forward direction. When the positive limit switch (POT) is input during homing, the drive will switch its driving direction. |
28 | The drive returns to the home position with the home switch (HOME) while driving in the reverse direction. When the negative limit switch (NOT) is input during homing, the drive will switch its driving direction. |
33 | The drive returns to the home position with the Index (Z) pulse while driving in the reverse direction. |
34 | The drive returns to the home position with the Index (Z) pulse while driving in the forward direction. |
35 | Sets the current position as the origin. |
-1 | The drive returns to the home position with the negative stopper and the Index (Z) pulse while driving in the reverse direction. |
-2 | The drive returns to the home position with the positive stopper and the Index (Z) pulse while driving in the forward direction. |
-3 | The drive only returns to the home position with the negative stopper while driving in the reverse direction. |
-4 | The drive only returns to the home position with the positive stopper while driving in the forward direction. |
-5 | During reverse operation, the motor is returned to the orign by Home switch |
-6 | During foward operation, the motor is returned to the orign by Home switch |
4. CiA402 Drive Profile
4-25
Related Objects
Index | Sub Index |
Name | Variable type | Accessibility | assignment PDO | Unit |
0x6040 | - | Controlword | UNIT | RW | Yes | - |
0x6041 | - | Statusword | UINT | RO | Yes | - |
0x607C | - | Home Offset | DINT | RW | No | UU |
0x6098 | - | Homing Method | SINT | RW | Yes | - |
0x6099 | - | Homing Speed | - | - | - | - |
0 | Number of entries | USINT | RO | No | - | |
1 | Speed during search for switch | UDINT | RW | Yes | UU/s | |
2 | Speed during search for zero | UDINT | RW | Yes | UU/s | |
0x609A | - | Homing Acceleration | UDINT | RW | Yes | UU/s2 |
4. CiA402 Drive Profile
4-26
Homing Methods 1 and 2
For homing using the Homing Method 1, the velocity profile according to the sequence is as follows.
See the details below:
(A) The initial driving direction is reverse (CW), and the drive operates at the Switch Search Speed.
(B) When the negative limit switch (NOT) is turned on, the drive switches its direction to the forward direction (CCW),
decelerating to the Zero Search Speed.
(C) While operating at the Zero Search Speed, the drive detects the first index pulse to move to the index position (Home).
Reverse (CW) Forward (CCW)
4. CiA402 Drive Profile
4-27
Methods 7, 8, 9, and 10
For homing using the Homing Method 7, the velocity profile according to the sequence is as follows.
The sequence depends on the relationship between the load position and the Home switch at homing,
which is categorized into three cases as below. For more information, see the details below:
(1) At the start of homing, when the Home switch is OFF and the limit is not met during
operation
(A) The initial driving direction is forward (CCW), and the drive operates at the Switch Search Speed.
(B) When the Positive Home Switch is turned on, the drive will decelerate to the Zero Search Speed, and then switches its
direction to the reverse direction (CW).
(C) While operating at the Zero Search Speed, the drive detects the first index pulse to move to the index position (Home).
(2) At the start of homing, when the Home switch is ON
Reverse (CW) Forward (CCW)
4. CiA402 Drive Profile
4-28
(A) Since the Home signal is on, the drive will operate at the Switch Search Speed in the direction of the Positive Home
Switch (CCW). It might not reach the Switch Search Speed depending on the start position of homing.
(B) When the Home switch is turned off, the drive will decelerate to Zero Search Speed, and then continue to operate.
(C) While operating at the Zero Search Speed, the drive detects the first index pulse to move to the index position (Home).
(3) At the start of homing, when the Home switch is OFF and the limit is met during
operation
(A) The initial driving direction is forward (CCW), and the drive operates at the Switch Search Speed.
(B) When the positive limit switch (POT) is turned on, the drive will decelerate down to stop, and then operate at the Switch
Search Speed in the reverse direction (CW).
(C) When the Positive Home switch is turned off, the drive will decelerate to Zero Search Speed, and then continue to
operate.
(D) While operating at the Zero Search Speed, the drive detects the first index pulse to move to the index position (Home).
The methods from 8 to 10 are nearly identical to the method 7 in terms of the homing sequence. The only differences are the
initial driving direction and Home switch polarity.
The Positive Home Switch is determined by the initial driving direction. A Home switch which is
encountered in the initial driving direction becomes the Positive Home Switch.
4. CiA402 Drive Profile
4-29
Methods 11, 12, 13, and 14
For homing using the Homing Method 14, the velocity profile according to the sequence is as follows.
The sequence depends on the relationship between the load position and the Home switch at homing,
which is categorized into three cases as below. For more information, see the details below:
Initial driving direction: Forward (CCW)
Initial driving direction: Reverse (CCW)
Reverse (CW) Forward (CW)
4. CiA402 Drive Profile
4-30
(1) At the start of homing, when the Home switch is OFF and the limit is not met during
operation
(A) The initial driving direction is reverse (CW), and the drive operates at the Switch Search Speed.
(B) When the Negative Home switch is turned off, the drive will decelerate to Zero Search Speed, and then continue to
operate.
(C) While operating at the Zero Search Speed, the drive detects the first index pulse to move to the index position (Home).
(2) At the start of homing, when the Home switch is ON
(A) Since the Home signal is on, the drive will operate at the Switch Search Speed in the direction of the Negative Home
Switch (CW). It might not reach the Switch Search Speed depending on the start position of homing.
(B) When the Home switch is turned off, the drive will decelerate to Zero Search Speed, and then continue to operate.
(C) While operating at the Zero Search Speed, the drive detects the first index pulse to move to the index position (Home).
4. CiA402 Drive Profile
4-31
(3) At the start of homing, when the Home switch is OFF and the limit is met during
operation
(A) The initial driving direction is reverse (CW), and the drive operates at the Switch Search Speed.
(B) When the negative limit switch (NOT) is turned on, the drive will decelerate down to stop, and then operate at the Switch
Search Speed in the forward direction (CCW).
(C) When the Negative Home Switch is turned on, the drive will decelerate to the Zero Search Speed, and then switches its
direction to the reverse direction (CW).
(D) While operating at the Zero Search Speed, the drive detects the first index pulse to move to the index position (Home).
The methods from 11 to 13 are nearly identical to the method 14 in terms of the homing sequence. The only differences are
the initial driving direction and Home switch polarity.
Method 24
The initial driving direction is forward (CCW), and a point where the Positive Home Switch is turned on becomes the Home
position.
Reverse (CW) Forward (CCW)
4. CiA402 Drive Profile
4-32
Method 28
The initial driving direction is reverse (CW), and a point where the Positive Home Switch is turned on becomes the Home position.
Method 33 and 34
The initial driving direction is reverse (CW) for the method 33, and forward (CCW) for the method 34. The drive detects the index
pulse at the Zero Search Speed.
Reverse (CW) Forward (CCW)
Reverse (CW) Forward (CCW)
4. CiA402 Drive Profile
4-33
Method 35
The current position at startup of homing operation becomes the Home position. This method is used to change the current
position to the origin depending on demand of the upper level controller.
Homing methods -1, -2, -3 and -4 are supported by this drive besides the standard ones. They can be
used if the Home switch is not used separately.
Method -1 and -2
Homing method -1 and -2 perform homing by using the Stopper and Index (Z) Pulse. The velocity
profile according to sequence is as follows. For more information, see the details below:
Reverse (CW) Forward (CCW)
Reverse (CW) Forward (CCW)
4. CiA402 Drive Profile
4-34
(A) The initial driving direction is reverse (CW), and the drive operates at the Switch Search Speed.
(B) (B) When the drive hits the negative stopper, it will stand by according to the torque limit value (0x2409) and the time
setting value (0x240A) at the time of homing using stopper before direction switch.
(C) While operating at the Zero Search Speed, the drive detects the first index pulse to move to the index position (Home).
(A) The initial driving direction is forward (CCW), and the drive operates at the Switch Search Speed.
(B) When the drive hits the positive stopper, it will stand by according to the torque limit value (0x2409) and the time setting
value (0x240A) at the time of homing using stopper before direction switch.
(C) While operating at the Zero Search Speed, the drive detects the first index pulse to move to the index position (Home).
Torque setting Time setting |
Torque setting |
Time setting |
4. CiA402 Drive Profile
4-35
Method -3 and -4
Homing method -3 and -4 only perform homing by using the Stopper. The velocity profile according to
sequence is as follows. For more information, see the details below:
(A) The initial driving direction is reverse (CW), and the drive operates at the Switch Search Speed.
(B) (B) When the drive hits the negative stopper, it will stand by according to the torque limit value (0x2409) and the time
setting value (0x240A) at the time of homing using stopper before homing is complete.
(A) The initial driving direction is forward (CCW), and the drive operates at the Switch Search Speed.
(B) When the drive hits the positive stopper, it will stand by according to the torque limit value (0x2409) and the time setting
value (0x240A) at the time of homing using stopper before homing is complete.
Reverse (CW) Forward (CCW)
Torque setting Time setting |
Homing complete |
Torque setting Homing complete |
Time setting |
4. CiA402 Drive Profile
4-36
Methods -5, -6
ㅜ
Homing Methods -5, -6 uses only Home switch to return to origin. The speed profile of each
sequence is as follows. When limit switch is detected, Homing is stopped. Please see the
explanations below for further details.
(1) Cases where the home witch is off when homing begins, and the limit is not met in the process
(A) The initial direction is reverse (CW). The motor operates at the switch search speed.
(B) When the positive home switch is on, the motor decelerates and stops. Then, home is
Completed
4. CiA402 Drive Profile
4-1
(2) Cases where the home witch is off when homing begins, and the limit is met in the process
Speed
Negative Limit switch ON Homing Error generated |
(A) (B) |
Homing Method
Time
Switch search speed
(0x6099:01)
(A) The initial direction is reverse (CW). The motor operates at the switch search speed.
(B) When the negative limit switch is on, Homing Error is generated. And then the motor
decelerated and stops
(A) The initial direction is forward (CCW). The motor operates at the switch search speed.
(B) When the positive home switch is on, the motor decelerates and stops. Then, home is
Completed
4. CiA402 Drive Profile
4-2
4.7 Touch Probe Function
Touch probe is a function to rapidly capture the position value of the encoder with external input
(PROBE 1 and 2) signals or the Index (Z) pulse of the encoder.
Example of Touch Probe
Wafer mapper system of wafer transfer robot (WTR)
In the case that wafers are piled up on a wafer stack, the presence of wafer can be determined by
scanning the stack once using mapping sensor. At this moment, any unnecessary movement of robot
can be prevented by use of the value of wafer loading position captured rapidly.
The position value of the encoder (Actual Position Value, 0x6064) is latched by the following trigger
events according to the setting value. At the same time, 2 channel inputs can be latched independently
at the positive/negative edges.
Triggered by the touch probe 1 (I/O, PROBE1)
Triggered by the touch probe 2 (I/O, PROBE2)
Triggered by the encoder Index (Z) pulse
Touch Probe function
Touch Probe status |
Touch Probe 1 Rising Edge Position Value |
Touch Probe 2 Rising Edge Position Value |
Touch Probe 2 Falling Edge Position Value |
Touch Probe 1 Falling Edge Position Value |
4. CiA402 Drive Profile
4-3
Related Objects
Index | Sub Index |
Name | Variable type | Accessibility | assignment PDO | Unit |
0x60B8 | - | Touch Probe Function | UINT | RW | Yes | - |
0x60B9 | - | Touch Probe Status | UINT | RO | Yes | - |
0x60BA | - | Touch Probe 1 Positive Edge Position Value | DINT | RO | Yes | UU |
0x60BB | - | Touch Probe 1 Negative Edge Position Value | DINT | RO | Yes | UU |
0x60BC | - | Touch Probe 2 Positive Edge Position Value | DINT | RO | Yes | UU |
0x60BD | - | Touch Probe 2 Negative Edge Position Value | DINT | RO | Yes | UU |
Touch Probe Timing Diagram
Single Trigger Mode (0x60B8.1=0, 0x60B8.9=0):
To reset the bits 1, 2, 9, and 10 of the touch probe status (0x60B9) in the single trigger mode, set the
corresponding bits (4, 5, 12, and 13) of the touch probe function (0x60B8) to 0.
4. CiA402 Drive Profile
4-4
Continuous Trigger Mode (0x60B8.1=1, 0x60B8.9=1):
In the continuous trigger mode, the bits 6, 7, 14, and 15 of the touch probe status (0x60B9) are toggled
(0 1 or 1 0) every time the corresponding input/edge is input.
Index Pulse Trigger Mode (0x60B8.2=1, 0x60B8.10=1):
5. Drive Application Functions
5-1
5. Drive Application Functions
5.1 Drive Front Panel
L/A 0 L/A 1 RUN ERR 0 1 2 3 4 5 6 8 9 7 x10 2 3 4 5 6 8 9 7 x1 0 1 |
노드 ID 설정 스위치 Node ID setting switch |
아날로그 모니터 출력 커넥터
서보 상태 표시 용 7-Segment
EtherCAT 통신 상태 및 에러 표시 LED
5.1.1 7-Segment for indicating servo status
7-Segment for indicating servo status consists of 5 digits as shown below, in the order of Digit1Digit5
from right to left:
DIGIT5 DIGIT4 DIGIT3 DIGIT2 DIGIT1
Three digits from Digits 3 to 1 of the 7 -Segment represents the drive status as described below if no
servo alarm occurs. In case of servo warning, they will indicate the warning status first, rather than
other ones.
Display of Digit 3 - Digit 1 | Status details |
STO connector not connected | Positive limit sensor input |
Servo OFF | Negative limit sensor input |
Analog monitor output connector
7-Segment for indicating servo status
LED for indicating EtherCAT communication state and error
5. Drive Application Functions
5-2
Servo ON | Servo warning W10 occurred (code: 10) |
Digit4 indicates the current operation status and servo ready status.
Digit5 indicates the status of the EtherCAT State Machine or of the current control mode and servo ON.
If the status of the EtherCAT State Machine is prior to the operation state (communication setup process): A preparation status, where a servo operation is not available, indicating that the EtherCAT communication is in progress. |
||
Init state | Pre-Operational state | Safe-Operational state |
If the status of the EtherCAT State Machine is the operation state (operation ready): A status, where a servo operation is available, indicating the operation mode and status. |
||
Position control modes: CSP, PP, and IP | Speed control modes: CSV and PV | Torque control modes: CST and PT |
Homing mode | (ON: Servo OFF, ON: Servo ON) |
In case of servo alarm, the Digits 5-1 blink and are displayed as below. The Digit 2 and the Digit 1
represent the alarm code. The servo alarm is displayed first, rather than other states.
TGON signal indication
(OFF: stop, ON: rotating)
For position control: INPOS1 signal indication
For speed control: INSPD signal indication
For torque control: OFF
For position control: Position command input in progress
For speed control: Speed command input in progress
For torque control: Torque command input in progress
Servo Ready Status Display
5. Drive Application Functions
5-3
Ex. 1) Limit signal input | Ex. 2) Servo warning triggered |
Positive limit input INPOS1, servo ready Position control mode, servo ON |
W01 (main power phase loss) + W40 (low voltage warning) occurred INSPD, speed command input in progress, servo ready Speed control mode, servo ON |
An example of alarm status output
5. Drive Application Functions
5-4
5.2 Input/Output Signals Setting
5.2.1 Assignment of Digital Input Signals
You can set the digital input signal function and input signal level of the I/O connector. You can
arbitrarily assign up to 8 input functions out of 12 functions, as shown in the figure below, to the digital
input signals 1-8 for use:
Related Objects
Index | Sub Index |
Name | Variable type |
Accessibility | PDO assignment |
Unit |
0x2200 | - | Digital Input Signal 1 Selection | UINT | RW | - | |
0x2201 | - | Digital Input Signal 2 Selection | UINT | RW | - | |
0x2202 | - | Digital Input Signal 3 Selection | UINT | RW | - | |
0x2203 | - | Digital Input Signal 4 Selection | UINT | RW | - | |
0x2204 | - | Digital Input Signal 5 Selection | UINT | RW | - | |
0x2205 | - | Digital Input Signal 6 Selection | UINT | RW | - | |
0x2206 | - | Digital Input Signal 7 Selection | UINT | RW | - | |
0x2207 | - | Digital Input Signal 8 Selection | UINT | RW | - |
Set the digital input signal function and input signal level of the I/O connector. Select signals to assign
with bits 7 - 0, and set the signal level to the bit 15.
Digital Input |
Assignable
Digital input 1~8 setting
Assigned function | Details |
Forward (CCW) rotation prohibited | |
Reverse (CW) rotation prohibited | |
Origin sensor | |
Servo stop | |
P control action | |
Switching of the gain 1 and gain 2 | |
Positive torque limit | |
Negative torque limit | |
Touch probe 1 | |
Touch probe 2 | |
Emergency stop | |
Alarm reset |
5. Drive Application Functions
5-5
Contact A: The default status is 0 (Low). Input 1
(High) to actuate it (Active High).
Contact B: The default status is 1 (High). Input
0 (Low) to actuate it (Active Low).
Example of Assigning Digital Input Signals
The following table shows an example of assigning input signals. Verify the setting values from 0x2200
to 0x2207.
DI#1 | DI#2 | DI#3 | DI#4 | DI#5 | DI#6 | DI#7 | DI#8 |
POT (Contact A) |
NOT (Contact A) |
HOME (Contact A) |
STOP (Contact A) |
PCON (Contact A) |
GAIN2 (Contact A) |
PROBE1 (Contact A) |
ARST (Contact A) |
Bit | Setting details |
15 | Signal input level settings (0: contact A, 1: contact B) |
14~8 | Reserved |
7~0 | Assign input signal. |
Setting values |
Assignable input signals |
0x00 | Not assigned |
0x01 | POT |
0x02 | NOT |
0x03 | HOME |
0x04 | STOP |
0x05 | PCON |
0x06 | GAIN2 |
0x07 | PCL |
0x08 | NCL |
0x09 | PROBE1 |
0x0A | PROBE2 |
0x0B | EMG |
0x0C | ARST |
Details | Assignable | Contact |
Forward (CCW) rotation prohibited | ||
Reverse (CW) rotation prohibited | ||
Origin sensor | ||
Servo stop | ||
P control action | ||
Switching of the gain 1 and gain 2 | ||
Positive torque limit | ||
Negative torque limit | ||
Touch probe 1 | ||
Touch probe 2 | ||
Emergency stop | ||
Alarm reset |
(Contact A) | ||||
(Pin Number) | Setting parameter |
Bit | Setting values | Details |
(Contact A) | ||||
(Contact B) | ||||
(Contact B) | ||||
(Contact A) | ||||
(Contact A) | ||||
(Contact A) | ||||
(Contact A) |
5. Drive Application Functions
5-6
5.2.2 Assignment of Digital Output Signals
You can set the digital output signal function and output signal level of the I/O connector. You can
arbitrarily assign up to 4 output functions out of 11 functions, as shown in the figure below, to the digital
output signals 1-4 for use:
Related Objects
Index | Sub Index |
Name | Variable type | Accessibility | assignment PDO | Unit |
0x2210 | - | Digital Output Signal 1 Selection | UINT | RW | - | |
0x2211 | - | Digital Output Signal 2 Selection | UINT | RW | - | |
0x2212 | - | Digital Output Signal 3 Selection | UINT | RW | - | |
0x2213 | - | Digital Output Signal 4 Selection | UINT | RW | - |
Assigns the digital output signal 1 function and set the output signal level of the I/O connector. Select
signals to assign with bits 7 - 0, and set the signal level to the bit 15.
Digital Output | Assignable Digital input 1~4 setting |
Assigned function Details
Brake
Alarm
Servo ready
Zero speed reached
Position reached 1
Torque Limit
Speed limit
Speed reached
Warning
Rotation detection output
Position reached 2
Servo Drive
5. Drive Application Functions
5-7
Examples of Assigning Digital Output Signals
The following table shows examples of assigning output signals. Verify the setting values from 0x2210
to 0x2213.
DO#1 | DO#2 | DO#3 | DO#4 |
BRAKE (Contact B) |
ALARM (Contact B) |
RDY (Contact A) |
INPOS1 (Contact A) |
Bit | Setting details |
15 | Signal output level settings (0: contact A, 1: contact B) |
14~8 | Reserved |
7~0 | Assign output signal |
Setting values | Assignable output signal |
0x00 | Not assigned |
0x01 | BRAKE |
0x02 | ALARM |
0x03 | RDY |
0x04 | ZSPD |
0x05 | INPOS1 |
0x06 | TLMT |
0x07 | VLMT |
0x08 | INSPD |
0x09 | WARN |
0x0A | TGON |
0x0B | INPOS2 |
(Contact A) | ||||
(Pin Number) | Setting parameter |
Bit | Setting values | Details |
(Contact B) | ||||
(Contact B) | ||||
(Contact A) |
Contact | Assigned function | Details |
Brake | ||
Alarm | ||
Servo ready | ||
Zero speed reached | ||
Position reached 1 | ||
Torque Limit | ||
Speed limit | ||
Speed reached | ||
Warning | ||
Rotation detection output | ||
Position reached 2 |
5. Drive Application Functions
5-8
5.2.3 Assignment of Analog Output Signals
Providing 2 channels of Analog monitor to adjust drive gains or to monintor state parameter
Retated objects
Index | Sub Index |
Name | Variable type | Accessibility | assignment PDO | Unit |
0x2220 | - | Analog Monitor Output Mode) | UINT | RW | No | - |
0x2221 | - | Analog Monitor Channel 1 Select | UINT | RW | No | - |
0x2222 | - | Analog Monitor Channel 2 Select | UINT | RW | No | - |
0x2223 | - | Analog Monitor Channel 1 Offset | DINT | RW | No | - |
0x2224 | - | Analog Monitor Channel 2 Offset | DINT | RW | No | - |
0x2225 | - | Analog Monitor Channel 1 Scale | UDINT | RW | No | - |
0x2226 | - | Analog Monitor Channel 2 Scale | UDINT | RW | No | - |
5. Drive Application Functions
5-9
Analog monitor output mode (0x2220)
Analog monitor output range is -10~+10V. If setting value is 1, output value is positive value only.
ut
Analog monitor channel 1 setting (0x2221)
Setting the parmeters to monitor through Analog monitor output channel 1
Th voltage is calculated as follow when analog monitor is output
Channel 1 output voltage [V] = [Monitoring signal value(0x2221) – Offset(0x2203)] / Scale(0x2205)
Channel 1 output voltage [V] = [Monitoring signal value (0x2222) – Offset(0x2204)] / Scale(0x2206)
Setting example
The following shows an example of monitoring ripple during 1000 rpm operation of speed feedback
signal
5. Drive Application Functions
5-10
5. Drive Application Functions
5-11
5.2.4 Use of User I/O
User I/O means that some of I/Os provided by the drive are used for individual purpose of the user, in
addition to the purpose of controlling the drive itself. All contacts provided by the input/output
connector(I/O) can be used as User I/O.
If only a few user I/Os are needed, you can wire the drive with the I/O connector rather than a separate
I/O module, reducing the cost.
This drive is available with up to 8 points for input signals and 4 points for output signals as the user I/O.
How to Set User Input
1) Set the function of digital input port to be used as the user input to "Not assigned (setting value of
0)." (Refer to Assignment of Input Signals.)
2) Read the values of the corresponding bits (0x60FD.16-23) from the digital input (0x60FD), in order
to use them as the user input.
Upper Level Controller
Digital Input |
Not assigned |
Servo Drive
5. Drive Application Functions
5-12
Related Objects
Index | Sub Index |
Name | Variable type | Accessibility | assignment PDO | Unit |
0x60FD | - | Digital Inputs | UDINT | RO | Yes | - |
Bit | Description |
0 | NOT (negative limit switch) |
1 | POT (positive limit switch) |
2 | HOME (origin sensor input) |
3 to 15 | Reserved |
16 | DI #1(I/O pin 11), 0:Open, 1:Close |
17 | DI #2(I/O pin 12), 0:Open, 1:Close |
18 | DI #3(I/O pin 7), 0:Open, 1:Close |
19 | DI #4(I/O pin 8), 0:Open, 1:Close |
20 | DI #5(I/O pin 13), 0:Open, 1:Close |
21 | DI #6(I/O pin 14), 0:Open, 1:Close |
22 | DI #7(I/O pin 9), 0:Open, 1:Close |
23 | DI #8(I/O pin 10), 0:Open, 1:Close |
24~30 | Reserved |
31 | STO(Safe Torque Off), 0:Close, 1:Open |
5. Drive Application Functions
5-13
How to Set User Output
1) Set the function of digital output port to be used as the user output to "Not assigned (setting value
of 0)." (Refer to Assignment of Output Signals.)
2) Set the bits (bits 16-19) corresponding to the port used as the user output for the bit mask
(0x60FE:02) to Forced Output Enabled (setting value: 1).
3) Using physical outputs (0x60FE:01), set the value corresponding to the user output for the relevant
port (bits 16-19) to 0 or 1.
Digital Output |
Not assigned |
Not assigned |
Servo Drive
Upper Level Controller
5. Drive Application Functions
5-14
Related Objects
Index | Sub Index |
Name | Variable type | Accessibility | assignment PDO | Unit |
0x60FE | - | Digital Outputs | - | - | - | - |
0 | Number of entries | USINT | RO | No | ||
1 | Physical outputs | UDINT | RW | Yes | - | |
2 | Bit mask | UDINT | RW | No | - |
They indicate the status of digital outputs.
Description of physical outputs
Bit | Description |
0 to 15 | Reserved |
16 | Forced output (0: OFF, 1: ON) of DO #1 (I/O pins 1 and 2) Provided that the relevant bit mask (0x60FE:02.16) is set to 1. |
17 | Forced output (0: OFF, 1: ON) of DO #2 (I/O pins 17 and 18) Provided that the relevant bit mask (0x60FE:02.17) is set to 1. |
18 | Forced output (0: OFF, 1: ON) of DO #3 (I/O pins 3 and 4) Provided that the relevant bit mask (0x60FE:02.18) is set to 1. |
19 | Forced output (0: OFF, 1: ON) of DO #4 (I/O pins 19 and 20) Provided that the relevant bit mask (0x60FE:02.19) is set to 1. |
20 to 23 | Reserved |
24 | Output status of DO #1 (0: OFF, 1: ON) |
25 | Output status of DO #2 (0: OFF, 1: ON) |
26 | Output status of DO #3 (0: OFF, 1: ON) |
27 | Output status of DO #4 (0: OFF, 1: ON) |
28 to 31 | Reserved |
Description of bit mask
Bit | Description |
0 to 15 | Reserved |
16 | Forced output setting (0: Disable, 1: Enable) of DO #1 (I/O pins 1 and 2) |
17 | Forced output setting (0: Disable, 1: Enable) of DO #2 (I/O pins 17 and 18) |
18 | Forced output setting (0:Disable, 1:Enable) of DO #3 (I/O pins 3 and 4) |
19 | Forced output setting (0:Disable, 1:Enable) of DO #4 (I/O pins 19 and 20) |
20 to 31 | Reserved |
5. Drive Application Functions
5-15
5.3 Electric Gear Setup
5.3.1 Electric Gear
This function sets the electric gear when you want to drive a motor by so-called user unit, the minimum
unit in which the user intends to give a command.
When using the electric gear function of the drive, you cannot utilize the highest resolution of the
encoder; thus, in case the upper level controller has the function, please use it if possible.
Set the gear ratio within the range of 1000-1/1000.
Typically, electric gears are used in the following situations:
(1) When Driving Loads Based on User Unit
- You can command the driving based on the user unit, regardless of the encoder (motor) type. For
the ball screw type of encoder with a pitch of 10 mm, the comparison is given below for 12 mm of
movement:
(A) 5000 ppr encoder | (B) 19-bit (524288 ppr) encoder | |
If the electric gear is not used |
5000*12/10 = 6000 | 524288*12/10=629145.6 |
Different command should be given depending on the encoder (motor) used for the same distance movement. |
||
For a command given in the minimum user unit of 1 um (0.001 mm) |
(A) 5000 ppr encoder
(B) 19-bit encoder
5. Drive Application Functions
5-16
Electric gear settings |
Motor Revolutions =5000 Shaft Revolutions = 10000 |
Motor Revolutions =524288 Shaft Revolutions = 10000 |
If the electric gear is used |
Can move through the same command of 12000 (12 mm= 12000 * 1 um), regardless of the encoder (motor) used. |
(2) When Driving High-Resolution Encoder at High Speed but Output Frequency of Upper Level
Controller or Input Frequency of Drive is Limited
- The output frequency of a general high-speed line drive pulse output unit is approximately 500
Kpps, while the allowed input frequency of the drive is approximately 1-4 Mpps. For this reason,
when driving a high-resolution encoder at high speed, be sure to use an electric gear for proper
driving due to the limitations of the output frequency of the upper level controller and the input
frequency of the drive. However, because there is no such limitations for a communication-type
drive (EtherCAT) like this drive, you do not have to use an electric gear.
5.3.2 Example of Electric Gear Setup
Ball Screw Load
Apparatus specification | Pitch: 10 mm, Reduction gear ratio: 1/1 |
User Unit | 1um(0.001mm) |
Encoder specification | 19-bit (524288 PPR) |
Amount of load movement/revolution |
10[mm] = 10000[User Unit] |
Electric gear settings | Motor Revolutions : 524288 Shaft Revolutions : 10000 |
Turntable Load
Apparatus specification | Reduction gear ratio: 100/1 |
User Unit | 0.001° |
5. Drive Application Functions
5-17
Encoder specification | 19-bit (524288 PPR) |
Amount of load movement/revolution |
360/100/0.001=3600 |
Electric gear settings | Motor Revolutions : 524288 Shaft Revolutions : 3600 |
Belt + Pulley System
Apparatus specification | Reduction gear ratio: 10/1, Pulley diameter: 100 mm |
User Unit | 1um(0.001mm) |
Encoder specification | 19-bit (524288 PPR) |
Amount of load movement/revolution |
PI*100/10/0.001=31416 |
Electric gear settings | Motor Revolutions : 524288 Shaft Revolutions : 31416 |
5.4 Settings Related to Speed Control
5.4.1 Smooth Acceleration and Deceleration
For smoother acceleration and deceleration during speed control, you can generate an
acceleration/deceleration profile with trapezoidal and S-curved shapes for driving. At this moment, Scurve operation is enabled by setting the speed command S-curve time to a value of 1 [ms] or more.
The speed command acceleration/deceleration time (0x2301 and 0x2302) is the time needed to
accelerate the drive from zero speed to the rated speed or to decelerate it from the rated speed to zero
speed.
속도
시간 Time |
모터 정격속도 Rated motor speed |
속도명령
가속시간(0x2301)
속도명령
감속시간(0x2302)
You can calculate the actual acceleration/deceleration time as below:
Acceleration time = speed command / rated speed x speed command acceleration time (0x2301)
Speed command
acceleration time (0x2301)
Speed command
deceleration time (0x2302)
Speed
5. Drive Application Functions
5-18
Deceleration time = speed command / rated speed x speed command deceleration time (0x2302)
As shown in the figure below, you can generate an S-curve shaped acceleration/deceleration profile for
driving by setting the speed command S-curve time (0x2303) at a value of 1 or more. Make sure to
verify the relationship between the acceleration/deceleration time and S-curve time.
속도
시간 Time |
|
Speed command S curve time (0x2303) |
Speed Command |
Speed command S curve time (0x2303) |
5.4.2 Servo-lock Function
During the speed control operation, the servo position will not be locked even when 0 is entered for a
speed command. This is due to the characteristic of speed control; at this moment, you can lock the
servo position by enabling the servo-lock function (0x2311).
Setting values | Setting details |
0 | Servo-lock function disabled |
1 | Servo-lock function enabled |
Using the servo-lock function, the position is internally controlled relative to the position at the time of
inputting 0 as a speed command. If you input a speed command other than 0, the speed control will be
switched to the normal mode.
5.4.3 Signals Related to Speed Control
As shown in the figure below, when the value of speed feedback is not more than the ZSPD output
range (0x2404), a ZSPD (zero speed) signal will be output; and when it is not less than the TGON
output range (0x2405), a TGON (motor rotation) signal will be output.
Speed
Acceleration time Deceleration time
5. Drive Application Functions
5-19
In addition, if the difference between the command and the speed feedback (i.e., speed error) is not
more than the INSPD output range (0x2406), an INSPD (speed match) signal will be output.
Related Objects
Index | Sub Index |
Name | Variable type | Accessibility | assignment PDO | Unit |
0x2404 | - | ZSPD Output Range | UINT | RW | Yes | rpm |
0x2405 | - | TGON Output Range | UINT | RW | Yes | rpm |
0x2406 | - | INSPD Output Range | UINT | RW | Yes | rpm |
5.5 Settings Related to Position Control
5.5.1 Position Command Filter
This section describes how to operate the drive more smoothly by applying a filter to a position
command. For the purpose of filtering, you can set position command filter time constant (0x2109)
using the primary low pass filter and position command average filter time constant (0x210A) using the
moving average.
You can use a position command filter if:
(1) If the electric gear ratio is 10 times or above
(2) the acceleration/deceleration profile cannot be generated from the upper level controller.
ZSPD output range
Speed
Time |
Motor velocity
TGON output range
5. Drive Application Functions
5-20
Speed
Time |
Command before filterin Command after filtering |
t velocity
t velocity
63%
velocity
7%
0x2109 0x2109
Position command filter using position command filter time constant (0x2109)
Speed
Time |
0x210A 0x210A |
Speed
Time |
Command befo Command after |
f
e
Command before filt
Command after filte
0x210A 0x210A
Position command filter using position command average filter time constant (0x210A)
Related Objects
Index | Sub Index |
Name | Variable type | Accessibility | assignment PDO | Unit |
0x2109 | - | Position Command Filter Time Constant | UINT | RW | Yes | 0.1ms |
0x210A | - | Position Command Average Filter Time Constant |
UINT | RW | Yes | 0.1ms |
Target velocity
*63%
Target velocity
*37%
Target velocity
Command before filtering
Command after filtering
Command before filtering
Command after filtering
5. Drive Application Functions
5-21
5.5.2 Signals Related to Position Control
As shown in the figure below, if the value of position error (i.e., the difference between the position
command value input by the upper level controller and the position feedback value) is not more than
the INPOS1 output range (0x2401), and is maintained for the INPOS1 output time (0x2402), the
INPOS1 (position completed 1) signal will be output, provided that the position command is not
renewed.
At this moment, if the position error value is not more than the INPOS2 output range (0x2403), the
INPOS2 (position completed 2) signal will be output, regardless of whether the position command has
been renewed or not.
Related Objects
Index | Sub Index |
Name | Variable type | Accessibility | assignment PDO | Unit |
0x2401 | - | INPOS1 Output Range | UINT | RW | Yes | UU |
0x2402 | - | INPOS1 Output Time | UINT | RW | Yes | ms |
0x2403 | - | INPOS2 Output Range | UINT | RW | Yes | UU |
INPOS1 (for output time = 0) | Time |
Time command |
Start time of renewing position |
Command Feedback |
Speed
End time of
renewing position
Positional Error
INPOS1/2
output
range
5. Drive Application Functions
5-22
5.6 Settings Related to Torque Control
5.6.1 Speed Limit Function
In the torque control mode, the torque command input from the upper level controller controls the
torque, but does not control the speed; thus, the apparatus might be damaged due to exceedingly
increased speed by an excessive torque command. To address this problem, this drive provides a
function that limits motor speed based on the parameters set during torque control.
You can limit the speed using the maximum speed or the speed limit value (0x230E) according to the
value of the speed limit function setting (0x230D), as described below. With the output value of VLMT
(speed limit), you can verify if the speed is limited.
Setting values | Setting details |
0 | Limited by speed limit value (0x230E) |
1 | Limited by the maximum motor speed |
Related Objects
Index | Sub Index |
Name | Variable type | Accessibility | assignment PDO | Unit |
0x230D | - | Speed Limit Function Select | UINT | RW | No | - |
0x230E | - | Speed Limit Value | UINT | RW | Yes | rpm |
5. Drive Application Functions
5-23
5.7 Positive/Negative Limit Settings
This function is to safely operate the drive within the movable range of the apparatus using the
positive/negative limit signals of the drive. Be sure to connect and set the limit switch for safe operation.
For more information about the settings, refer to 5.2.1 Assignment of Digital Input Signals.
If the positive/negative limit signals are input, the motor will stop according to the emergency stop
setting (0x2013).
Setting values | Description |
0 | The motor will stop according to the method set in the dynamic brake control mode (0x2012). It will stop using the dynamic brake, and then maintain the torque command at 0. |
1 | Decelerates to stop using the emergency stop torque (0x2113). |
Related Objects
Index | Sub Index |
Name | Variable type | Accessibility | assignment PDO | Unit |
0x2012 | - | Dynamic Brake Control Mode | UINT | RW | No | - |
0x2013 | - | Emergency Stop Configuration | UINT | RW | No | - |
0x2113 | - | Emergency Stop Torque | UINT | RW | Yes | - |
(Default value)
(Default value)
5. Drive Application Functions
5-24
5.8 Setting the Brake Output Signal Function
If the motor stops due to servo OFF or servo alarm during rotation, you can set the speed (0x2407) and
delay time (0x2408) for brake signal output, in order to configure the output timing.
The brake signal will be output if the motor rotation speed goes below the set speed (0x2407) or the
output delay time (0x2408) has elapsed after the servo OFF command.
Timing diagram for signal output by the brake output speed (0x2407)
회전속도
서보ON/OFF
브레이크
신호
서보OFF 또는 알람발생 (0x240 (0x2407) |
브레이크 출력 지연시간 Brake output delay time |
(0x2408)
브레이크 출력 속도
Timing diagram for signal output by the brake output delay time (0x2408)
Set the time to delay until the actual PWM output goes off when the servo is turned off or a servo alarm
occurs.
When using a motor with a brake installed on the vertical axis, you can output the brake signal first,
and then turn off the PWM after this set time, in order to prevent it from running down along the axis.
Brake signal
Brake output speed
(0x2407) |
Rotation
speed
Servo
ON/OFF
Servo OFF or alarm occurred
Brake output delay time
(0x2408)
Rotation
speed
Servo ON/OFF
Brake signal
Servo OFF or alarm occurred
(0x2408)
Brake output speed
5. Drive Application Functions
5-25
중력방향
Motor |
부하 Load |
(1) If Brake Signal Outputs First Before PWM Output Turns off
You can output the brake signal first before the PWM output is turned off, preventing the drop along the
vertical axis due to the gravity.
중력방향
Motor |
부하 Load |
(2) If PWM Output Turns off First Before Brake Signal Outputs
The PWM output is turned off first before the brake signal output, allowing the drop along the vertical
axis due to the gravity.
Gravity
direction
PWM output
Servo
ON/OFF
Brake signal
Servo OFF or
alarm occurred
PWM OFF delay time (0x2411) |
Time when the PWM output
is turned off
PWM output
Servo
ON/OFF
Brake signal
Servo OFF or
alarm occurred
PWM OFF dela time (0x2411) |
y |
Time when the PWM output
is turned off
Gravity
direction
5. Drive Application Functions
5-26
5.9 Torque Limit Function
You can limit the drive output torque to protect the machine. It can be set by the torque limit function
(0x2110). The setting unit of torque limit value is 0.1%.
Description of Torque Limit Function Setting (0x2110)
Limit function | Description |
Internal torque limit 1 (set value 0) |
Limits the torque using positive/negative torque limit value according to the driving direction; the maximum value is limited by the maximum torque (0x6072). - Forward: 0x60E0, Reverse: 0x60E1 Torque input Forward torque limit Negative torque limit Maximum torque |
Internal torque limit 2 (set value 1) |
Limits the torque only by the maximum torque (0x6072) regardless of the driving direction. Maximum torque Torque input |
External torque limit (set value 2) |
Limits the torque using external positive/negative torque limit value according to the driving direction. - Forward: 0x2111, Reverse: 0x2112 Forward torque limit Negative torque limit Torque input |
5. Drive Application Functions
5-27
Internal and external torque limits (set value 3) |
Limits the torque using internal and external torque limit value according to the driving direction and the torque limit signal. - Forward: 0x60E0(if PCL signal is not input), 0x2111(if PCL signal is input) - Reverse: 0x60E1(if NCL signal is not input), 0x2112(if NCL signal is input) Torque input Forward torque limit Negative torque limit External forward torque limit External negative torque limit |
Analog torque limit (set value 4) |
Torque input Torque Ref. I/O connecter Torque is limited as inputting voltage in Pin5,15 - Restricted by torque limited value which in put as analog. - Restriced normal direction / reverse direction torque regardless of +/ - of analog voltage. - Refer offset(0x221C) and then scale(0x221C) of analog torque limitation. |
5. Drive Application Functions
5-28
Related Objects
Index | Sub Index |
Name | Variable type | Accessibility | assignment PDO | Unit |
0x2110 | - | Torque Limit Function Select | UINT | RW | Yes | - |
0x2111 | - | External Positive Torque Limit Value | UINT | RW | Yes | 0.1% |
0x2112 | - | External Negative Torque Limit Value | UINT | RW | Yes | 0.1% |
0x6072 | - | Maximum Torque | UINT | RW | Yes | 0.1% |
0x60E0 | - | Positive Torque Limit Value | UNIT | RW | Yes | 0.1% |
0x60E1 | - | Negative Torque Limit Value | UINT | RW | Yes | 0.1% |
Maximum torque
Forward torque
limit
Negative torque
limit
External forward
torque limit
External negative
torque limit
5. Drive Application Functions
5-29
5.10 Gain switching function
5.10.1 Gain group switching
GAIN2 센서 입력
게인 그룹2 사용 게인 그룹1 사용
This function is to switch between the gain groups 1 and 2, as one of gain adjustment methods. You
can reduce the time required for positioning through switching gains.
A gain group consists of position loop gain, speed loop gain, speed loop integral time constant, and
torque command filter time constant. The gain switching function (0x2119) can be set as follows:
Description of Gain Switching Function (0x2119)
Setting values | Setting details |
0 | Only the gain group 1 is used. |
1 | Only the gain group 2 is used. |
2 | Gain is switched according to the GAIN2 input status. - 0: Use gain group 1 - 1: Use gain group 2 |
3 | Reserved |
4 | Reserved |
5 | Reserved |
6 | Gain is switched according to the ZSPD output status. - 0: Use gain group 1 - 1: Use gain group 2 |
7 | Gain is switched according to the INPOS1 output status. - 0: Use gain group 1 - 1: Use gain group 2 |
GAIN2 sensor input
Use gain group 2 Use gain group 1
5. Drive Application Functions
5-30
Waiting time and switching time for gain switching is as follows:
Gain group 1 Gain switching time 1 (0x211A)
Gain switching waiting time 1 (0x211C)
Gain switching time 2 (0x211B)
Gain switching waiting time 2 (0x211D)
Gain group 2
Position loop gain 1 (0x2101)
Speed loop gain 1 (0x2102)
Speed loop integral time constant 1 (x2103)
Torque command filter time constant 1 (0x2104)
Position loop gain 2 (0x2105)
Speed loop gain 2 (0x2106)
Speed loop integral time constant 2 (x2107)
Torque command filter time constant 2 (0x2108)
Related Objects
Index | Sub Index |
Name | Variable type | Accessibility | assignment PDO | Unit |
0x2119 | - | Gain Conversion Mode | UINT | RW | Yes | - |
0x211A | - | Gain Conversion Time 1 | UINT | RW | Yes | ms |
0x211B | - | Gain Conversion Time 2 | UINT | RW | Yes | ms |
0x211C | - | Gain Conversion Waiting Time 1 | UINT | RW | Yes | ms |
0x211D | - | Gain Conversion Waiting Time 2 | UINT | RW | Yes | ms |
Gain | Gain switching condition is met |
switching con Gain group |
Gain group 2 |
Gain group 1 |
dition is not met
Waiting time 1 Switching time 1 Waiting time 2 Switching time 2
5. Drive Application Functions
5-31
5.10.2 P/PI Control Switching
PI control uses both proportional (P) and integral (I) gains of the speed controller, while P control uses
only proportional gain.
The proportional gain determines the responsiveness of the entire controller, and the integral gain is
used to eliminate an error in the steady state. Too high of an integral gain will result in an overshoot
during acceleration or deceleration.
The PI/P control switching functions are used to switch between the PI and P controls under the
condition of the parameters within the servo (such as torque, speed, acceleration, and position
deviation); specifically, they are used under the following situations:
Speed control: To suppress any overshoot or undershoot during acceleration/deceleration.
Position control: To suppress undershoot during positioning, resulting in a reduced positioning time.
You can accomplish similar effect by setting the acceleration/deceleration of the upper level controller,
the soft start of the servo drive, the position command filter, or etc.
You can configure these settings in the P/PI control switching mode (0x2114). Please see the details
below: Switching to P control by PCON input takes precedence over this setting.
Setting values | Setting details |
0 | Always uses the PI control. |
1 | Switches to the P control if the command torque is larger than the P control switching torque (0x2115). |
2 | Switches to the P control if the command speed is larger than the P control switching speed (0x2116). |
3 | Switches to the P control if the acceleration command is larger than the P control switching acceleration (0x2117). |
4 | Switches to the P control if the position error is larger than the P control switching position error (0x2118). |
Positioning time
Speed
Time
Overshoot Motor speed Speed Command |
Undershoot
5. Drive Application Functions
5-32
Related Objects
Index | Sub Index |
Name | Variable type | Accessibility | assignment PDO | Unit |
0x2114 | - | P/PI Control Conversion Mode | UINT | RW | Yes | - |
0x2115 | - | P Control Switch Torque | UINT | RW | Yes | 0.1% |
0x2116 | - | P Control Switch Speed | UINT | RW | Yes | rpm |
0x2117 | - | P Control Switch Acceleration | UINT | RW | Yes | rpm/s |
0x2118 | - | P Control Switch Following Error | UINT | RW | Yes | pulse |
Example of P/PI Switching by Torque Command
When always using the PI Control rather than P/PI control switching for speed control, the integral term
of acceleration/deceleration error is accumulated, resulting in an overshoot and an extended
positioning time. At this moment, you can reduce the overshoot and the positioning time using an
appropriate P/PI switching mode. The figure below shows an example of switching mode by torque
command:
Torque Command time |
Time |
Overshoot When using P control |
T |
Overshoot When using PI/P control switching |
T |
Speed Speed
Speed
P control P control P control P control P control
Positioning
Positioning
time
5. Drive Application Functions
5-33
5.11 Dynamic brake
What is Dynamic Brake?
Dynamic brake electrically short-circuits the phase of the servo motor to stop it rapidly.
Circuits related to the dynamic brake are integrated into the drive.
The drive short-circuits only two phases or all of three phases depending on the model type.
You can set various stop modes, as shown below, in dynamic brake control mode settings [0x2012]:
회전속도 서보ON/OFF 다이나믹 브레이크 Setting value: 0 Hold the dynamic brake after stopping the motor using the brake Servo ON/OFF Rotation speed Dynamic brake |
회전속도 서보ON/OFF 다이나믹 브레이크 Setting value: 1 Release the dynamic brake after stopping the motor using the brake Servo ON/OFF Rotation speed Dynamic brake |
회전속도 서보ON/OFF 다이나믹 브레이크 Servo ON/OFF Rotation speed Dynamic brake |
회전속도 서보ON/OFF 다이나믹 브레이크 Servo ON/OFF Rotation speed Dynamic brake |
Drive
Servo Motor
5. Drive Application Functions
5-34
Setting value: 2 Release the dynamic brake after free run stop |
Setting value: 3 Hold the dynamic brake after free-run stop |
Related Objects
Index | Sub Index |
Name | Variable type | Accessibility | assignment PDO | Unit |
0x2012 | - | Dynamic Brake Control Mode | UINT | RW | No | - |
0x2013 | - | Emergency Stop Configuration | UINT | RW | No | - |
5.12 Regenerative resistance setting
Regeneration refers to a phenomenon where the kinetic energy of the motor is converted to electric
energy and input into the drive because of driving a load with large inertia or sudden deceleration. At
this moment, regenerative resistor is used to suppress the rise of the drive's internal voltage (VDC) due
to the regeneration and prevent the drive burnout.
Servo Drive
Sudden deceleration
Load with large
inertia
Motor |
Electric energy Kinetic energy |
Voltage
rise
5. Drive Application Functions
5-35
Related Objects
Index | Sub Index |
Name | Variable type | Accessibility | assignment PDO | Unit |
0x2009 | - | Regeneration Brake Resistor Configuration | UINT | RW | No | - |
0x200A | - | Regeneration Brake Resistor Derating Factor | UINT | RW | No | % |
0x200B | - | Regeneration Brake Resistor Value | UINT | RW | No | Ω |
0x200C | - | Regeneration Brake Resistor Capacity | UINT | RW | No | Watt |
5.12.1 Use of Internal Regenerative Resistor
This drive essentially has internal regenerative resistor depending on its capacity. The integrated
regenerative resistors depending on the drive capacity are as follows:
Drive Capacity | Internal resistance value | Internal resistor capacity |
1kW | 100[Ω] | 100[W] |
2kW/3.5kW | 40[Ω] | 150[W] |
5kW | 27[Ω] | 120[W] |
7.5KW | 27[Ω] | 240[W] |
Note) By default, 15KW uses external resistance (13.4[Ω], 2000[W])
When using the regenerative resistor installed in the drive, make sure to observe the order below for
configuration:
1. Wire the regenerative resistor.
- Check to see if the terminals B and BI are short-circuited (short-circuited at factory setup, 3.5 kW
or less).
Note) For 5KW and 7.5KW, check if B+ and B terminals are short-circuited. They are shorted before
shipped.
Intern regen resist |
al erative ance |
Wiring method when using internal
regenerative resistor
5. Drive Application Functions
5-36
2. Set regenerative resistance (0x2009)
- Configure to use the regenerative resistor integrated into the drive (0x2009 = 0).
- Basically, the resistor is attached on the rear of the drive heat sink.
- Initial value: 0
3. Check internal regenerative resistance value and capacity
- Check the internal regenerative resistance value (0x200B).
- Check the regenerative resistor capacity (0x200C).
- 1 KW or less: Basically, the resistor is installed on the rear of the drive heat sink (see the figure
below).
- 7.5 KW or less: It is basically installed inside the drive.
- 15 KW or more: Internal regenerative resistance is not installed
Internal regenerative resistor
installed on the rear of drive,
1 kW or less
5. Drive Application Functions
5-37
5.12.2 Use of External Regenerative Resistor
When using the external regenerative resistor considering the driving condition, make sure to observe
the order below for configuration:
1. Wire the external regenerative resistor.
- Remove the short circuit at B and BI terminals and connect the external regenerative resistance
to B and B+ terminals (for 3.5KW or less)
- Remove the internal regenerative resistance at B+ and B terminals and connect the external
regenerative resistance to B+ and B terminals (for 5KW and 7.5KW)
- Connect the standard external regenerative resistance to B+ and B terminals (for 15KW)
2. Set regenerative resistance (0x2009)
- Configure to use the regenerative resistor installed separately outside the drive (0x2009=1).
- Set if a regenerative resistance is connected of a capacity which is larger than that of the internal
regenerative resistance.
3. Set regenerative resistance value (0x200B)
- Configure the regenerative resistance of a resistor installed separately outside the drive in the
unit of [Ω].
- Be sure to configure it when you have set the regenerative resistor (0x2009) to 1.
- Initial value: 0
4. Set the regenerative resistor capacity (0x200C).
Wiring method when using external
regenerative resistor
External
regenerative
resistor
External
regenerative
resistor
5. Drive Application Functions
5-38
- Configure the capacity of a regenerative resistor installed separately outside the drive in the unit
of [W].
- Be sure to configure it when you have set the regenerative resistor (0x2009) to 1.
- Initial value: 0
5. Set the maximum capacity and allowed time of the regenerative resistance (0x200D, 0x200E)
- Set the maximum capacity and use time at the capacity by using the data sheet of the externally
installed regenerative resistance
- If there are no specific values, set the maximum capacity and allowed time to 5 times the
regenerative resistance capacity setting (0x200C) and 5000[ms], respectively (It may differ
according to general regenerative resistance specification or individual resistors).
- Be sure to configure it when you have set the regenerative resistor (0x2009) to 1.
LSIS provides the following regenerative resistors as options for the purpose of external regenerative
resistor (see the specifications as well):
Drive Capacity | Resistance | Resistor capacity | Model name |
1KW | 82[Ω] | 300[W] | IRV300-82Ω |
2KW/3.5KW | 70[Ω] | 600[W]*2P | IRV600-140Ω |
5KW | 25[Ω] | 600[W]*3P | IRV600-75Ω |
7.5KW | 25[Ω] | 600[W]*3P | IRV600-75Ω |
15KW | 13.4[Ω] | 2000[W] | IRM2000-13.4Ω |
5.12.3 Other Considerations
With the considerations of the ambient environment and heat radiation condition for installing the drive,
you can configure the regenerative resistor derating factor (0x200A). In case that the heat radiation
condition is poor, please use a derated resistor (less than the capacity).
When it is derated for use (setting the value not larger than 100), the less the set value, the earlier the
regeneration overload alarm (AL-23) is triggered.
When you intend to set the derating factor to 100% or higher, be sure to fully consider the heat
radiation condition of the drive installed.
5. Drive Application Functions
5-39
5.13 Configuration of Drive Node Address (ADDR)
Configure the drive node address. You can verify the set address in the node ID (0x2003). The value of
the node setting switch is read just once when the power is turned on. Any set value modified
subsequently will be in effect only when the power is turned on again.
As this drive consists of two rotary switches configurable to 0~9 as below, 0~99 node addresses can be
set. The following example shows an address set to 48:
Perform rotary switch operation for node ID setting only when drive power is not applied.
0 1
2
3
4 5
6
8 9
7
x10
2
3 4
5 6
8 9
7
x1
0 1
Note) For more information about how the master reads the node address of the EtherCAT drive, refer
to 18.4.1 Requesting ID in the document titled "ETG.1020 EtherCAT Protocol Enhancements."
6. Safety Functions
6-1
6. Safety Functions
This servo drive has built-in safe torque off (STO) function to reduce the risk while using the machine
by protecting people around the machine against dangerous operation of its movable parts. Especially,
this function can be used to prevent dangerous operation of the machine's movable parts when you
need to perform tasks such as maintenance in a danger zone.
6.1 Safe Torque Off (STO) Function
The safe torque off function blocks motor current according to the input signal transferred from a safety
device connected to the connector (STO), such as safety controller and safety sensor, to stop the
motor.
Safe torque off operation state according to STO input contact
Signal Name | Function | |||
STO1 | ON | ON | OFF | OFF |
STO2 | ON | OFF | ON | OFF |
Operation state | Normal state | STO state | STO state | STO state |
Electric characteristics
STO1 and STO2
Item | Characteristic value |
Internal impedance | 3.3 ㏀ |
Voltage input range | DC 12V ~ DC 24V |
Maximum delay time | 1 ms or less |
EDM
Item | Characteristic value |
Maximum allowed voltage | DC 30V |
Maximum current | DC 120mA |
Maximum delay time | 1 ms or less |
6. Safety Functions
6-2
Timing diagram for STO operation
Note 1) If at least one of STO1 and 2 is turned off, the drive state is switched to the STO state.
Note 2) The dynamic brake operates according to the dynamic brake control mode setting (0x2012).
Note3) Whichever the earlier time, out of points of time until the value becomes less than the set value of
the brake output delay time (0x2408) or that of the brake output speed (0x2407) , will be applied.
PWM Off Delay Time[0x2011] setting + 3[ms](DB Hold time) Brake engaged |
STO state |
DB engaged (Operated by DB Control Mode[0x2012] setting) |
Servo ON/OFF
ervo ON | Servo OFF |
Normal state
Motor supplied
with power
EDM output
Dynamic brake relay
Brake output
Brake disengaged
DB disengaged
6. Safety Functions
6-3
Timing diagram for STO recovery
Note 1) Be sure to recover the input signals of STO1 and 2 to ON at the servo OFF state. It is not
necessary to reset alarm separately since the "STO state" is not an alarm state.
Note 2) The dynamic brake operates according to the dynamic brake control mode setting (0x2012) for the
STO state, the alarming state, and the servo OFF state.
After the servo is turned on, it operates according to normal servo ON/OFF timing. |
Normal state |
Brake maintained |
DB engaged |
Servo ON/OFF
ervo OFF | Servo ON |
STO state
Motor supplied with
power
EDM output
Dynamic brake relay
Brake output
6. Safety Functions
6-4
6.2 External Device Monitor (EDM)
Monitor output signal is to monitor the state of safety input signal with an external device.
Connect it to the terminal for external device monitor of safety device such as safety controller or safety
sensor.
Failure detection through EDM signal
You can detect failure of the safety input circuit and the EDM output circuit by monitoring the following 4
signal states from the external device.
In case of failure, there are two possible cases:
The EDM output signal is not turned on even when both the STO1 and 2 are off.
The EDM output signal is turned on even when one or both of the STO1 and 2 are on.
Signal Name | Function | |||
STO1 | ON | ON | OFF | OFF |
STO2 | ON | OFF | ON | OFF |
EDM | OFF | OFF | OFF | ON |
6. Safety Functions
6-5
6.3 Example of Using Safety Function
6.4 How to Verify Safety Function
In case that the servo drive was replaced prior to the device startup or during maintenance, make sure
to check the details below:
When STO1 and STO2 signals are turned OFF, check if the drive is in STO status (Bit 31 of digital
input (0x60FD) is 1).
Make sure that the EDM signal is off during general operation by checking the input indicator for
feedback circuit of the connected device.
Safety unit Blocking
Driving signal
Blocking
EDM output
6. Safety Functions
6-6
6.5 Precautions for Using Safety Function
When using the STO function, be sure to carry out risk assessment for the device to check if the
safety requirements of the system are met.
There may be risks even if the STO function works.
At the STO state, the motor is operated by an external force; thus, if the load needs to be
maintained, arrange a separate measure such as external mechanical brake. The brake of the
servo system is dedicated for maintaining the load; thus, be careful not to use it to brake the motor.
If no external force exists and free-run stop is configured in the dynamic brake control mode setting
(0x2012), note that the braking distance of load will be extended.
The purpose of the STO function is not to block the servo drive power or electrically insulate the
drive. That is why you have to disconnect the servo drive power before carrying out the
maintenance of any sub-drive.
7. Tuning
7-1
7. Tuning
The drive is set to the torque control, the speed control, or the position control mode for use, depending
on the method to connect with the upper level controller. This drive is structured so that the position
control is located at the outermost while the current control at the innermost, forming a cascade style
control structure. Depending on the operation mode of the drive, you can tune the operation by setting
the gain-related parameters of the torque controller, the speed controller, and the position controller, to
satisfy your purpose.
7.1 Off-line Auto Gain Tuning
Use the command generated by the drive itself to automatically set the gain according to the load
condition. The following gain-related parameters will be changed:
Inertia ratio, position loop gain, speed loop gain, speed integral time constant, torque command
filter time constant, notch filter 3 frequency, and notch filter 4 frequency.
The entire gain is set higher or lower depending on the system rigidity setting (0x250E) during gain
tuning. Set the appropriate value depending on the rigidity of the load.
As shown in the figure below, sinusoidal-type command is generated in the forward or reverse direction
according to the offline gain tuning direction (0x2510) setting. You can set the movement distance for
tuning with the offline gain tuning distance (0x2511). The larger the setting value is, the longer the
movement distance becomes. Set the distance appropriately for the case. Make sure to secure enough
distance (more than one revolution of motor) prior to gain tuning.
Encoder
Moving
distance
Position
command
Speed
command
Torque
command
Voltage
command
Power
circuit
Current feedback
Position feedback
Position
control
operation
Speed
control
operation
Torque
control
operation
Motor
Tuning direction = 0
(positive) Tuning direction = 1
(negative)
Offline gain tuning
distance (0x2511)
Time |
Response
Command
7. Tuning
7-2
Related Objects
Index | Sub Index |
Name | Variable type | Accessibility | assignment PDO | Unit |
0x250E | System Rigidity for Gain Tuning | UINT | RW | No | - | |
0x2510 | - | Off-line Gain Tuning Direction | UINT | RW | No | - |
0x2511 | Off-line Gain Tuning Distance | UINT | RW | No | - |
7.2 On-line Auto Gain Tuning
Does not use the off-line auto gain tuning command generated by itself(XDL-L7NH Drive) and While
operating under the command form host device, it sets parameters related gain automatically base on
general rule and the rigidity set by user.
inertia, position loop gain, speed loop gain, speed integral time, torque command filter time
constant
During online tuning, it refers 20 steps of value of gain table by rigidity. The result of tuning is reflected
regulary and changed gain is stored in EEPROM every two minutes.
When intertia estimating, estimated result reflected quickly or slowly by set adaption speed value. The
setting rigidity parameters can determine the overall responsiveness of system.
7. Tuning
7-3
In the following cases, it may be inaccurate to estimate the inertia when online auto tuning.
When a change of the load is too heavy
When rigidity of load is too weak or too heavy backlash system.
When the load is too small(less than 3 times) or too heavy (more than 20 times)
When acceleration and deceleration is too small for sufficient acceleration and deceleration
torque(less than 10% of the rated).
When the speed of revolution is too slow(less than 10% of the rated).
When friction torque is too large.
If the above conditions or on-line auto tuning system doesn’t operate well, please run an off-line gain
tuning.
7.3 Manual Gain Tuning
7.3.1 Gain Tuning Sequence
For a cascade-type controller, tune the gain of the speed controller located at an inner position first,
and then tune the gain of the position controller located at an outer position.
In other words, tune the gains in the order of proportional gain integral gain feedforward gain.
The role of each individual gain is as follows:
- Proportional gain: Determines the controller BW.
- Integral gain: Determines error of steady-state, and generates an overshoot.
- Feedforward gain: Enhances the system lag characteristic.
- Differential gain: Plays a role of damper for the system (not provided)
Speed Controller Tuning
(1) Inertia ratio setting
- Use automatic inertia estimation function or carry out manual setting.
(2) Proportional gain setting
- Monitor torque and noise before any vibration occurs.
(3) Integral gain setting
- Monitor the speed overshoot and the steady-state error.
- You can use the P/PI switching mode if you want to increase the integral gain but overshoot occurs.
- For this drive, the integral gain is set to the integral time constant.
(4) Speed command filter and speed feedback filter setting
7. Tuning
7-4
Position Controller Tuning
(1) Proportional gain setting
- Monitor torque, positional error, and noise before any vibration occurs.
(2) Feedforward setting
- Positional error monitoring
- Able to set the feedforward filter.
- Set the filter if you want to increase the feedforward value but noise occurs.
- You can set the feedforward value from 0% to 100%, which is the ratio of the position command
value being entered currently and the deviation.
(3) Able to set the position command filter
- You can smooth a position command.
7. Tuning
7-5
7.4 Vibration Control
7.4.1 Notch Filter
Notch filter is a sort of band stop filter to eliminate specific frequency component. You can use a notch
filter to eliminate the resonant frequency component of an apparatus, resulting in avoiding vibration
while setting a higher gain.
This drive provides notch filters with 4 steps in total, and you can set the frequency, width, and depth
for each filter. You can use one or two notch filters as adaptive filter, setting the frequency and the width
automatically through real-time frequency analysis (FFT).
Related Objects
Index | Sub Index |
Name | Variable type | Accessibility | assignment PDO | Unit |
0x2501 | - | Notch Filter 1 Frequency | UINT | RW | No | Hz |
0x2502 | - | Notch Filter 1 Width | UINT | RW | No | - |
0x2503 | - | Notch Filter 1 Depth | UINT | RW | No | - |
0x2504 | - | Notch Filter 2 Frequency | UINT | RW | No | Hz |
0x2505 | - | Notch Filter 2 Width | UINT | RW | No | - |
0x2506 | - | Notch Filter 2 Depth | UINT | RW | No | - |
0x2507 | - | Notch Filter 3 Frequency | UINT | RW | No | Hz |
0x2508 | - | Notch Filter 3 Width | UINT | RW | No | - |
0x2509 | - | Notch Filter 3 Depth | UINT | RW | No | - |
0x250A | - | Notch Filter 4 Frequency | UINT | RW | No | Hz |
0x250B | - | Notch Filter 4 Width | UINT | RW | No | - |
0x250C | - | Notch Filter 4 Depth | UINT | RW | No | - |
Frequency
Amplitude
Depth |
Width |
7. Tuning
7-6
7.4.2 Adaptive Filter
Adaptive filter analyzes the real-time frequency of vibration frequency, generated from the load during
the drive operation, through the speed feedback signal, and configures a notch filter automatically to
reduce vibration.
It can detect the vibration frequency through frequency analysis to automatically configure one or two
notch filters. On this occasion, the frequency and its width are automatically set and the setting value
for the depth is used as it is.
Related Objects
Index | Sub Index |
Name | Variable type | Accessibility | assignment PDO | Unit |
0x2500 | - | Adaptive Filter Function Setting | UINT | RW | No | - |
Adaptive Filter Function Setting (0x2500)
Setting values | Setting details |
0 | Adaptive filter is not used. |
1 | Only one adaptive filter is used. You can check the settings configured automatically in the Notch Filter 4 Settings (0x250A and 0x250B). |
2 | Only two adaptive filters are used. You can check the settings configured automatically in the Notch Filter 3 (0x2507 and 0x2508) and 4 Settings (0x250A and 0x250B). |
3~5 | Reserved |
7. Tuning
7-7
7.4.3 Vibration Control (Damping) Filter
Vibration control (damping) filter is to decrease vibration occurring in the load.
Measuring vibration frequency occurring in the load throuth the external sensor, and using
measured value as the object data for vibration control (damping) filter. XDL-L7NH has two
vibration control (damping) filter in total. Reagarding each filter, It’s available to set up the
frequency and volume of decreasing vibration.
XDL-L7NH controls frequency from 1[Hz] to 100[Hz] coming from load or total system. This
function is only available on position control mode.
Rerated object
Index | Sub Index |
Name | Variable type | Acceessibility | assignment PDO | Unit |
0x2515 | - | Vibration Suppression Filter Configuration | UINT | RW | No | - |
0x2516 | - | Vibration Suppression Filter 1 Frequency | UINT | RW | No | 0.1[Hz] |
0x2517 | - | Vibration Suppression Filter 1 Damping | UINT | RW | No | - |
0x2518 | - | Vibration Suppression Filter 2 Frequency | UINT | RW | No | 0.1[Hz] |
0x2519 | - | Vibration Suppression Filter 2 Damping | UINT | RW | No | - |
Vibration Suppression Filter Configuration (0x2515)
7. Tuning
7-8
Setting Value | Setting Details |
0 | Not using Vibration control (damping) filter |
1 | Applying Vibration control (damping) filter 1,2 |
2 | Applying Vibration control (damping) filter 1,2 according to LVSF1, LVSF2 digital input. |
7.5 Analog Monitor
Two channels of analog monitor outputs are provided to adjust drive gain or monitor internal status
variables.
Related Objects
Index | Sub Index |
Name | Variable type | Accessibility | assignment PDO | Unit |
0x2220 | - | Analog Monitor Output Mode | UINT | RW | No | - |
Analog Output |
Digital Input |
Digital Output
7. Tuning
7-9
0x2221 | - | Analog Monitor Channel 1 Setting | UINT | RW | No | - |
0x2222 | - | Analog Monitor Channel 2 Setting | UINT | RW | No | - |
0x2223 | - | Analog Monitor Channel 1 Offset | DINT | RW | No | - |
0x2224 | - | Analog Monitor Channel 2 Offset | DINT | RW | No | - |
0x2225 | - | Analog Monitor Channel 1 Scale | UDINT | RW | No | - |
0x2226 | - | Analog Monitor Channel 2 Scale | UDINT | RW | No | - |
Analog Monitor Output Mode (0x2220) Setting
The output range of analog monitor is from -10 V to +10 V. If the setting is 1, take the absolute value of
the output to make the output value only be positive.
Analog Monitor Channel 1 Setting (0x2221)
Configure the monitoring variables to be output to the analog monitor output channel 1.
Setting values | Displayed item | Unit |
0 | Speed feedback | rpm |
1 | Speed command | rpm |
2 | Speed error | rpm |
3 | Torque feedback | % |
4 | Torque command | % |
5 | Positional Error | pulse |
6 | Accumulated Operation Overload | % |
Analog output
voltage
Setting values | Settings | Description |
Output as negative/positive values |
||
Output only positive values |
Analog output |
voltage
7. Tuning
7-10
7 | DC link voltage | V |
8 | Accumulated Regeneration Overload | % |
9 | Encoder single-turn data | pulse |
10 | Inertia ratio | % |
11 | Full-Closed positional error | UU |
12 | Drive temperature 1 | °C |
13 | Drive temperature 2 | °C |
14 | Encoder temperature 1 | °C |
The voltage is calculated as below during the analog monitor output:
Channel 1 output voltage [V] = [Monitoring signal value (0x2221) – Offset (0x2203)] / Scale (0x2205)
Channel 2 output voltage [V] = [Monitoring signal value (0x2222) – Offset (0x2204)] / Scale (0x2206)
Setting Example
The following shows an example of monitoring ripple during 1000 rpm operation of speed feedback
signal:
신호 5배 확대
모니터링
출력 오프셋: 1000 rpm
출력 스케일: 500rpm/V
출력 오프셋: 0 rpm
출력 스케일: 500rpm/V
출력 오프셋: 1000 rpm
출력 스케일: 100rpm/V
Monitor signals by
magnifying them 5
times
Output offset
Output scale
Output offset
Output scale
Output offset
Output scale
8. Procedure Function
8-1
8. Procedure Function
Procedure function is an auxiliary function provided by the drive as described below. It can be executed
by procedure command code (0x2700) and procedure command factor (0x2701). It can be activated
using servo setting tool.
Procedure command | Codes | Details |
Manual JOG | 0x0001 | Manual JOG operation |
Program JOG | 0x0002 | Programs JOG operation |
Alarm History Reset | 0x0003 | Alarm history reset |
Off-Line Auto-Tuning | 0x0004 | Offline auto-tuning |
Index Pulse Search | 0x0005 | Phase Z position search |
Absolute Encoder Reset | 0x0006 | Absolute encoder reset |
Max. Load Torque Clear | 0x0007 | Resets instantaneous maximum operation overload (0x2604) value |
Calibrate Phase Current Offset | 0x0008 | Phase current offset tuning |
Software Reset | 0x0009 | Software reset |
Commutation | 0x000A | Commutation |
8.1 Manual JOG Operation
Jog operation is a function to verify the servo motor operation by the speed control, without an upper
level controller.
Before starting the jog operation, make sure that:
the main power is turned on;
the STO (Safe Torque Off) connector is connected;
no alarms go off;
the servo is turned off;
the operation speed is set with the consideration of the apparatus state.
Related Objects
Index | Sub Index |
Name | Variable type | Accessibility | assignment PDO | Unit |
0x2300 | - | Jog Operation Speed | INT | RW | No | rpm |
0x2301 | - | Speed Command Acceleration Time | UINT | RW | No | ms |
0x2302 | - | Speed Command Deceleration Time | UINT | RW | No | ms |
0x2303 | - | Speed Command S-curve Time | UINT | RW | No | ms |
8. Procedure Function
8-2
8.2 Programmed Jog Operation
Programmed jog operation is a function to verify the servo motor operation by the speed control at
preset operation speed and time, without an upper level controller.
Before starting the jog operation, make sure that:
the main power is turned on;
the STO (Safe Torque Off) connector is connected;
no alarms go off;
the servo is turned off;
the speed and time settings are set with the consideration of the state and operation range of the
apparatus.
Reverse
Motor speed |
Motor speed |
Speed
Motor speed
Time
Zero speed Forward Zero speed Zero speed Forward
8. Procedure Function
8-3
Related Objects
Index | Sub Index |
Name | Variable type |
Accessibility | PDO assignment |
Unit |
0x2304 | - | Programmed Jog Operation Speed 1 (Program Jog Operation Speed 1) |
INT | RW | No | rpm |
0x2305 | - | Programmed Jog Operation Speed 2 (Program Jog Operation Speed 2) |
INT | RW | No | rpm |
0x2306 | - | Programmed Jog Operation Speed 3 (Program Jog Operation Speed 3) |
INT | RW | No | rpm |
0x2307 | - | Programmed Jog Operation Speed 4 (Program Jog Operation Speed 4) |
INT | RW | No | rpm |
0x2308 | - | Programmed Jog Operation Time 1 (Program Jog Operation Time 1) |
UINT | RW | No | ms |
0x2309 | - | Programmed Jog Operation Time 2 (Program Jog Operation Time 2) |
UINT | RW | No | ms |
0x230A | - | Programmed Jog Operation Time 3 (Program Jog Operation Time 3) |
UINT | RW | No | ms |
0x230B | - | Programmed Jog Operation Time 4 (Program Jog Operation Time 4) |
UINT | RW | No | ms |
8.3 Deleting Alarm History
This function deletes all of the alarm code history stored in the drive. Alarm history items are stored
chronologically starting with the latest alarm up to 16 recent alarms.
You can check them as below (0x2702:01 - 16). The latest alarm is listed in 0x2702:01.
8. Procedure Function
8-4
Related Objects
Index | Sub Index |
Name | Variable type | Accessibility | assignment PDO | Unit |
0x2702 | - | Servo Alarm History (Servo Alarm History) |
- | - | - | - |
1 | Alarm code 1 (Newest) (Alarm code 1(Newest)) |
STRING | RO | No | - | |
2 | Alarm code 2 (Alarm code 2) |
STRING | RO | No | - | |
3 | Alarm code 3 (Alarm code 3) |
STRING | RO | No | - | |
4 | Alarm code 4 (Alarm code 4) |
STRING | RO | No | - | |
5 | Alarm code 5 (Alarm code 5) |
STRING | RO | No | - | |
6 | Alarm code 6 (Alarm code 6) |
STRING | RO | No | - | |
7 | Alarm code 7 (Alarm code 7) |
STRING | RO | No | - | |
8 | Alarm code 8 (Alarm code 8) |
STRING | RO | No | - | |
9 | Alarm code 9 (Alarm code 9) |
STRING | RO | No | - | |
10 | Alarm code 10 (Alarm code 10) |
STRING | RO | No | - | |
11 | Alarm code 11 (Alarm code 11) |
STRING | RO | No | - | |
12 | Alarm code 12 (Alarm code 12) |
STRING | RO | No | - | |
13 | Alarm code 13 (Alarm code 13) |
STRING | RO | No | - | |
14 | Alarm code 14 (Alarm code 14) |
STRING | RO | No | - | |
15 | Alarm code 15 (Alarm code 15) |
STRING | RO | No | - | |
16 | Alarm code 16 (Alarm code 16(Oldest)) |
STRING | RO | No | - |
8. Procedure Function
8-5
8.4 Auto Gain Tuning
For more information, refer to Section 7.1 Off-line Auto Gain Tuning.
8.5 Index Pulse Search
Index pulse search function is to find the Index (Z) pulse position of the encoder and stop. You can use
this function to locate a position roughly since it searches for a position using the speed operation
mode. You can locate the exact position of the index pulse using the homing operation.
The speed to search for the index pulse is set in 0x230C [rpm].
Before starting the index pulse search, make sure that:
the main power is turned on;
no alarms go off;
the servo is turned off;
the Safet Torque Off (STO) connector is installed; and
the operation speed is set with consideration to the operation range of the machine.
Related Objects
Index | Sub Index |
Name | Variable type | Accessibility | assignment PDO | Unit |
0x230C | - | Index Pulse Search Speed (Index Pulse Search Speed) |
INT | RW | No | rpm |
Intends to align the motor shaft to the
origin of the machine.
Coupling
Rotor
Servo Motor
Origin
8. Procedure Function
8-6
8.6 Absolute encoder reset
This function resets the absolute encoder. You need to reset the absolute encoder if:
you set up the apparatus for the first time;
there occurs an alarm for low voltage of encoder; or
you want to set multi-turn data of the absolute encoder to 0.
When the absolute encoder reset is completed, the multi-turn data (0x260A) and the single-turn data
(0x2607) are reset to 0. After the reset, turn on the power again to change the actual position value
(0x6064) to the reset position value.
After turning on the power again, the actual position value (0x6064) is displayed by reading the position
of the absolute encoder and applying the home offset (0x607C).
Then, the actual position value (0x6064) will not be changed even if you change the home offset
(0x607C) during operation.
Related Objects
Index | Sub Index |
Name | Variable type | Accessibility | assignment PDO | Unit |
0x2005 | - | Absolute Encoder Configuration (Absolute Encoder Configuration) |
UINT | RW | No | - |
0x260A | Multi-Turn Data (MultiTurn Data) |
DINT | RO | Yes | rev |
8.7 Instantaneous Maximum Torque Initialization
This function initializes the instantaneous maximum overload rate (0x2604) to 0. The instantaneous
maximum operation overload rate represents the maximum value of the operation overload rate output
instantaneously from the drive during the 15 seconds.
It displays the maximum (peak) load, during the 15 secconds, as a percentage of the rated output. The
unit is [0.1%]. Turning on the power again will reset it to 0.
In case that the current driving load factor is larger than the stored
instantaneous maximum driving overload factor, the renewal will be done; and
this value is displayed in 0x2604.
Torque
Instantaneous maximum
overload value
Renewed
Not renewed
8. Procedure Function
8-7
Related Objects
Index | Sub Index |
Name | Variable type | Accessibility | assignment PDO | Unit |
0x2604 | - | Instantaneous Maximum Operation Overload (Instantaneous Maximum Operation Overload) |
INT | RO | Yes | 0.1% |
8.8 Phase current offset tuning
This function is to automatically tune the current offset of U/V/W phases. Depending on the
environmental condition, you can tune the phase current offset for use. The offset is tuned by factory
default setting.
Measured U-/V-/W-phase offsets are individually stored in 0x2015, 0x2016, and 0x2017. If an offset is
too large, AL-15 will be generated.
Related Objects
Index | Sub Index |
Name | Variable type | Accessibility | assignment PDO | Unit |
0x2015 | - | Phase U Current Offset (U Phase Current Offset) |
INT | RW | No | 0.1% |
0x2016 | - | Phase V Current Offset (V Phase Current Offset) |
INT | RW | No | 0.1% |
0x2017 | - | Phase W Current Offset (W Phase Current Offset) |
INT | RW | No | 0.1% |
8. Procedure Function
8-8
8.9 Software reset
This function is to reset the servo drive by means of software. Software reset means a restart of the
drive program, resulting in an effect similar to recycling the power.
You can use this function if:
you changed parameter settings which require the power to be recycled; or
you have to restart the drive due to an alarm which cannot be reset.
8.10 Commutation
Commutation function is to get the information on the initial angle of motor. In case of using a motor
with hall sensor not installed, you have to get the information on the initial angle through commutation
prior to operation, in order to carry out normal operation.
Related Objects
Index | Sub Index |
Name | Variable type | Accessibility | assignment PDO | Unit |
0x2019 | - | Linear Scale Resolution (Linear Scale Resolution) |
UINT | RW | No | nm |
0x201A | - | Commutation Method (Commutation Method) |
UINT | RW | No | - |
0x201B | - | Commutation Current (Commutation Current) |
UINT | RW | No | 0.1% |
0x201C | - | Commutation Time (Commutation Time) |
UINT | RW | No | ms |
9. Object Dictionary
9-1
9. Object Dictionary
Object is a data structure including parameters, state variables, run commands (procedures), and etc.
within a drive.
Object can be mainly divided into general object (from 0x1000) for EtherCAT communication, CiA402
object (from 0x6000) for CAN application over EtherCAT (CoE), and manufacturer specific object (from
0x2000) exclusively provided by this drive.
9.1 General Objects
0x1000 | Device Type | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UDINT | - | 0x00020192 | - | RO | No | - | No |
The following table lists device types and their functions.
0x1001 | Error Register | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | assignment PDO | attribute Change | Storage |
USINT | - | 0x00 | - | RO | No | - | No |
The following table shows the error register values for each device. This value is stored in the
emergency message.
Bit | Setting details |
0 | 0 : No error |
1 : Error occurs | |
1 to 7 | Reserved |
0x1008 | Device Name | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | assignment PDO | attribute Change | Storage |
STRING | - | - | - | RO | No | - | No |
Represents the device name.
Servo Drive
9. Object Dictionary
9-2
0x1009 | Hardware Version | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | assignment PDO | attribute Change | Storage |
STRING | - | - | - | RO | No | - | No |
Represents the hardware version of the device.
0x100A | Software Version | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | assignment PDO | attribute Change | Storage |
STRING | - | - | - | RO | No | - | No |
Represents the software version of the device.
0x1010 | Store Parameters | ||||||
SubIndex 0 | Number of entries | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
USINT | - | 4 | - | RO | No | - | No |
SubIndex 1 | Store all parameters | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | 0 to 0xFFFFFFFF | 0 | - | RW | No | - | No |
SubIndex 2 | Store communication parameters | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | 0 to 0xFFFFFFFF | 0 | - | RW | No | - | No |
SubIndex 3 | Store CiA402 parameters | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | 0 to 0xFFFFFFFF | 0 | - | RW | No | - | No |
SubIndex 4 | Store drive specific parameters | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | 0 to 0xFFFFFFFF | 0 | - | RW | No | - | No |
Store the drive's parameters into the memory. To avoid any mistake, store the parameters if the ASCII
code value corresponding to 'save' is written to the relevant SubIndex value.
All parameters within the drive are stored when "save" is written to SubIndex 1.
Only communication parameters (from 0x1000) are stored when "save" is written to SubIndex 2.
ASC11 code
9. Object Dictionary
9-3
Only CiA402 parameters (from 0x6000) are stored when "save" is written to SubIndex 3.
Only drive-specific parameters (from 0x2000) are stored when "save" is written to SubIndex 4.
0x1011 | Restore Default Parameters | ||||||
SubIndex 0 | Number of entries | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | assignment PDO | attribute Change | Storage |
USINT | - | 4 | - | RO | No | - | No |
SubIndex 1 | Restore all parameters | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UDINT | 0 to 0xFFFFFFFF | 0 | - | RW | No | - | No |
SubIndex 2 | Restore communication parameters | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UDINT | 0 to 0xFFFFFFFF | 0 | - | RW | No | - | No |
SubIndex 3 | Restore CiA402 parameters | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UDINT | 0 to 0xFFFFFFFF | 0 | - | RW | No | - | No |
SubIndex 4 | Restore drive specific parameters | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UDINT | 0 to 0xFFFFFFFF | 0 | - | RW | No | - | No |
Initialize the drive's parameters. To avoid any mistake, initialize the parameters if the ASCII code value
corresponding to 'save' is written to the relevant SubIndex value.
All parameters within the drive are initialized when "load" is written to SubIndex 1.
Only communication parameters (from 0x1000) are initialized when "load" is written to SubIndex 2.
Only CiA402 parameters (from 0x6000) are initialized when "load" is written to SubIndex 3.
Only drive-specific parameters (from 0x2000) are initialized when "load" is written to SubIndex 4.
To apply the initialized value, you need to recycle the power of the drive.
0x1018 | Identity Object | ||||||
SubIndex 0 | Number of entries | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
USINT | - | 4 | - | RO | No | - | No |
SubIndex 1 | Vendor ID | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
ASC11 code
9. Object Dictionary
9-4
UDINT | - | 0x00007595 | - | RO | No | - | No |
SubIndex 2 | Product code | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | - | 0x00010001 | - | RO | No | - | No |
SubIndex 3 | Revision number | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | - | - | - | RO | No | - | No |
SubIndex 4 | Serial number | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | - | - | - | RO | No | - | No |
Represents the device information.
0x1600 | 1st Receive PDO Mapping | ||||||
SubIndex 0 | Number of entries | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
USINT | 0 to 10 | 5 | - | RW | No | PREOP | Yes |
SubIndex 1 | Mapping entry 1 | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | 0 to 0xFFFFFFFF | 0x60400010 | - | RW | No | PREOP | Yes |
SubIndex 2 | Mapping entry 2 | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | 0 to 0xFFFFFFFF | 0x60710010 | - | RW | No | PREOP | Yes |
SubIndex 3 | Mapping entry 3 | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | 0 to 0xFFFFFFFF | 0x607A0020 | - | RW | No | PREOP | Yes |
SubIndex 4 | Mapping entry 4 | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | 0 to 0xFFFFFFFF | 0x60600008 | - | RW | No | PREOP | Yes |
SubIndex 5 | Mapping entry 5 | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | 0 to 0xFFFFFFFF | 0x60B80010 | - | RW | No | PREOP | Yes |
SubIndex 6 | Mapping entry 6 | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | 0 to 0xFFFFFFFF | - | - | RW | No | PREOP | Yes |
SubIndex 7 | Mapping entry 7 |
9. Object Dictionary
9-5
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | 0 to 0xFFFFFFFF | - | - | RW | No | PREOP | Yes |
SubIndex 8 | Mapping entry 8 | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | 0 to 0xFFFFFFFF | - | - | RW | No | PREOP | Yes |
SubIndex 9 | Mapping entry 9 | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | 0 to 0xFFFFFFFF | - | - | RW | No | PREOP | Yes |
SubIndex 10 | Mapping entry 10 | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | 0 to 0xFFFFFFFF | - | - | RW | No | PREOP | Yes |
9. Object Dictionary
9-6
PDO Mapping :
Configure the Process Data Objects (PDO) to perform real-time data transfer through the CANopen
over EtherCAT protocol. This drive can freely map up to 10 objects of PDOs for transmission/reception,
respectively.
Use 0x1600 - 0x1603 to set the receiving PDO mapping, and 0x1A00 - 0x1A03 to set the transmitting
PDO mapping. Configure information on the objects below that you want to assign to items 1 to 10
(SubIndex 1 - 10). You have to set the number of the objects to be assigned for the number of items
(SubIndex 0).
Bit 0-7: Bit lengths of objects to be mapped (ex: displayed as 0x20 for 32-bit data)
Bit 8-15: SubIndex of objects to be mapped
Bit 16-31: Index of objects to be mapped
0x1601 | 2nd Receive PDO Mapping | ||||||
SubIndex 0 | Number of entries | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
USINT | 0 to 10 | 4 | - | RW | No | PREOP | Yes |
SubIndex 1 | Mapping entry 1 | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | 0 to 0xFFFFFFFF | 0x60400010 | - | RW | No | PREOP | Yes |
SubIndex 2 | Mapping entry 2 | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | 0 to 0xFFFFFFFF | 0x607A0020 | - | RW | No | PREOP | Yes |
SubIndex 3 | Mapping entry 3 | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | 0 to 0xFFFFFFFF | 0x60B80010 | - | RW | No | PREOP | Yes |
SubIndex 4 | Mapping entry 4 | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | 0 to 0xFFFFFFFF | 0x60FE0120 | - | RW | No | PREOP | Yes |
SubIndex 5 | Mapping entry 5 | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | 0 to 0xFFFFFFFF | - | - | RW | No | PREOP | Yes |
SubIndex 6 | Mapping entry 6 | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | 0 to 0xFFFFFFFF | - | - | RW | No | PREOP | Yes |
SubIndex 7 | Mapping entry 7 |
9. Object Dictionary
9-7
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | 0 to 0xFFFFFFFF | - | - | RW | No | PREOP | Yes |
SubIndex 8 | Mapping entry 8 | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | 0 to 0xFFFFFFFF | - | - | RW | No | PREOP | Yes |
SubIndex 9 | Mapping entry 9 | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | 0 to 0xFFFFFFFF | - | - | RW | No | PREOP | Yes |
SubIndex 10 | Mapping entry 10 | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | 0 to 0xFFFFFFFF | - | - | RW | No | PREOP | Yes |
Refer to the description of 0x1600.
0x1602 | 3rd Receive PDO Mapping | ||||||
SubIndex 0 | Number of entries | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
USINT | 0 to 10 | 4 | - | RW | No | PREOP | Yes |
SubIndex 1 | Mapping entry 1 | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | 0 to 0xFFFFFFFF | 0x60400010 | - | RW | No | PREOP | Yes |
SubIndex 2 | Mapping entry 2 | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | 0 to 0xFFFFFFFF | 0x60FF0020 | - | RW | No | PREOP | Yes |
SubIndex 3 | Mapping entry 3 | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | 0 to 0xFFFFFFFF | 0x60B80010 | - | RW | No | PREOP | Yes |
SubIndex 4 | Mapping entry 4 | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | 0 to 0xFFFFFFFF | 0x60FE0120 | - | RW | No | PREOP | Yes |
SubIndex 5 | Mapping entry 5 | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | 0 to 0xFFFFFFFF | - | - | RW | No | PREOP | Yes |
SubIndex 6 | Mapping entry 6 | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | 0 to 0xFFFFFFFF | - | - | RW | No | PREOP | Yes |
SubIndex 7 | Mapping entry 7 |
9. Object Dictionary
9-8
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | 0 to 0xFFFFFFFF | - | - | RW | No | PREOP | Yes |
SubIndex 8 | Mapping entry 8 | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | 0 to 0xFFFFFFFF | - | - | RW | No | PREOP | Yes |
SubIndex 9 | Mapping entry 9 | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | 0 to 0xFFFFFFFF | - | - | RW | No | PREOP | Yes |
SubIndex 10 | Mapping entry 10 | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | 0 to 0xFFFFFFFF | - | - | RW | No | PREOP | Yes |
Refer to the description of 0x1600.
0x1603 | 4th Receive PDO Mapping | ||||||
SubIndex 0 | Number of entries | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
USINT | 0 to 10 | 4 | - | RW | No | PREOP | Yes |
SubIndex 1 | Mapping entry 1 | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | 0 to 0xFFFFFFFF | 0x60400010 | - | RW | No | PREOP | Yes |
SubIndex 2 | Mapping entry 2 | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | 0 to 0xFFFFFFFF | 0x60710010 | - | RW | No | PREOP | Yes |
SubIndex 3 | Mapping entry 3 | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | 0 to 0xFFFFFFFF | 0x60B80010 | - | RW | No | PREOP | Yes |
SubIndex 4 | Mapping entry 4 | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | 0 to 0xFFFFFFFF | 0x60FE0120 | - | RW | No | PREOP | Yes |
SubIndex 5 | Mapping entry 5 | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | 0 to 0xFFFFFFFF | - | - | RW | No | PREOP | Yes |
SubIndex 6 | Mapping entry 6 | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | 0 to 0xFFFFFFFF | - | - | RW | No | PREOP | Yes |
9. Object Dictionary
9-9
SubIndex 7 | Mapping entry 7 | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | 0 to 0xFFFFFFFF | - | - | RW | No | PREOP | Yes |
SubIndex 8 | Mapping entry 8 | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | 0 to 0xFFFFFFFF | - | - | RW | No | PREOP | Yes |
SubIndex 9 | Mapping entry 9 | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | 0 to 0xFFFFFFFF | - | - | RW | No | PREOP | Yes |
SubIndex 10 | Mapping entry 10 | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | 0 to 0xFFFFFFFF | - | - | RW | No | PREOP | Yes |
Refer to the description of 0x1600.
0x1A00 | 1st Transmit PDO Mapping | ||||||
SubIndex 0 | Number of entries | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
USINT | 0 to 10 | 10 | - | RW | No | PREOP | Yes |
SubIndex 1 | Mapping entry 1 | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | 0 to 0xFFFFFFFF | 0x60410010 | - | RW | No | PREOP | Yes |
SubIndex 2 | Mapping entry 2 | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | 0 to 0xFFFFFFFF | 0x60770010 | - | RW | No | PREOP | Yes |
SubIndex 3 | Mapping entry 3 | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | 0 to 0xFFFFFFFF | 0x60640020 | - | RW | No | PREOP | Yes |
SubIndex 4 | Mapping entry 4 | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | 0 to 0xFFFFFFFF | 0x60F40020 | - | RW | No | PREOP | Yes |
SubIndex 5 | Mapping entry 5 | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | 0 to 0xFFFFFFFF | 0x60FD0020 | - | RW | No | PREOP | Yes |
SubIndex 6 | Mapping entry 6 | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
9. Object Dictionary
9-10
UDINT | 0 to 0xFFFFFFFF | 0x60610008 | - | RW | No | PREOP | Yes |
SubIndex 7 | Mapping entry 7 | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | 0 to 0xFFFFFFFF | 0x26010010 | - | RW | No | PREOP | Yes |
SubIndex 8 | Mapping entry 8 | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | 0 to 0xFFFFFFFF | 0x26000010 | - | RW | No | PREOP | Yes |
SubIndex 9 | Mapping entry 9 | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | 0 to 0xFFFFFFFF | 0x60B90010 | - | RW | No | PREOP | Yes |
SubIndex 10 | Mapping entry 10 | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | 0 to 0xFFFFFFFF | 0x60BA0020 | - | RW | No | PREOP | Yes |
Refer to the description of 0x1600.
0x1A01 | 2nd Transmit PDO Mapping | ||||||
SubIndex 0 | Number of entries | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
USINT | 0 to 10 | 6 | - | RW | No | PREOP | Yes |
SubIndex 1 | Mapping entry 1 | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | 0 to 0xFFFFFFFF | 0x60410010 | - | RW | No | PREOP | Yes |
SubIndex 2 | Mapping entry 2 | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | 0 to 0xFFFFFFFF | 0x60640020 | - | RW | No | PREOP | Yes |
SubIndex 3 | Mapping entry 3 | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | 0 to 0xFFFFFFFF | 0x60F40020 | - | RW | No | PREOP | Yes |
SubIndex 4 | Mapping entry 4 | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | 0 to 0xFFFFFFFF | 0x60B90010 | - | RW | No | PREOP | Yes |
SubIndex 5 | Mapping entry 5 | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | 0 to 0xFFFFFFFF | 0x60BA0020 | - | RW | No | PREOP | Yes |
SubIndex 6 | Mapping entry 6 | ||||||
Variable | Setting range | Initial value | Unit | Accessibility | PDO | Change | Storage |
9. Object Dictionary
9-11
type | assignment | attribute | |||||
UDINT | 0 to 0xFFFFFFFF | 0x60FD0020 | - | RW | No | PREOP | Yes |
SubIndex 7 | Mapping entry 7 | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | 0 to 0xFFFFFFFF | - | - | RW | No | PREOP | Yes |
SubIndex 8 | Mapping entry 8 | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | 0 to 0xFFFFFFFF | - | - | RW | No | PREOP | Yes |
SubIndex 9 | Mapping entry 9 | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | 0 to 0xFFFFFFFF | - | - | RW | No | PREOP | Yes |
SubIndex 10 | Mapping entry 10 | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | 0 to 0xFFFFFFFF | - | - | RW | No | PREOP | Yes |
Refer to the description of 0x1600.
0x1A02 | 3rd Transmit PDO Mapping | ||||||
SubIndex 0 | Number of entries | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
USINT | 0 to 10 | 5 | - | RW | No | PREOP | Yes |
SubIndex 1 | Mapping entry 1 | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | 0 to 0xFFFFFFFF | 0x60410010 | - | RW | No | PREOP | Yes |
SubIndex 2 | Mapping entry 2 | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | 0 to 0xFFFFFFFF | 0x60640020 | - | RW | No | PREOP | Yes |
SubIndex 3 | Mapping entry 3 | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | 0 to 0xFFFFFFFF | 0x60B90010 | - | RW | No | PREOP | Yes |
SubIndex 4 | Mapping entry 4 | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | 0 to 0xFFFFFFFF | 0x60BA0020 | - | RW | No | PREOP | Yes |
SubIndex 5 | Mapping entry 5 | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibil ity |
PDO assignment |
Change attribute |
Storage |
UDINT | 0 to 0xFFFFFFFF | 0x60FD0020 | - | RW | No | PREOP | Yes |
SubIndex 6 | Mapping entry 6 | ||||||
Variable | Setting range | Initial value | Unit | Accessibility | PDO | Change | Storage |
9. Object Dictionary
9-12
type | assignment | attribute | |||||
UDINT | 0 to 0xFFFFFFFF | - | - | RW | No | PREOP | Yes |
SubIndex 7 | Mapping entry 7 | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | 0 to 0xFFFFFFFF | - | - | RW | No | PREOP | Yes |
SubIndex 8 | Mapping entry 8 | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | 0 to 0xFFFFFFFF | - | - | RW | No | PREOP | Yes |
SubIndex 9 | Mapping entry 9 | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | 0 to 0xFFFFFFFF | - | - | RW | No | PREOP | Yes |
SubIndex 10 | Mapping entry 10 | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | 0 to 0xFFFFFFFF | - | - | RW | No | PREOP | Yes |
Refer to the description of 0x1600.
0x1A03 | 4th Transmit PDO Mapping | ||||||
SubIndex 0 | Number of entries | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
USINT | 0 to 10 | 5 | - | RW | No | PREOP | Yes |
SubIndex 1 | Mapping entry 1 | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | 0 to 0xFFFFFFFF | 0x60410010 | - | RW | No | PREOP | Yes |
SubIndex 2 | Mapping entry 2 | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | 0 to 0xFFFFFFFF | 0x60640020 | - | RW | No | PREOP | Yes |
SubIndex 3 | Mapping entry 3 | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | 0 to 0xFFFFFFFF | 0x60B90010 | - | RW | No | PREOP | Yes |
SubIndex 4 | Mapping entry 4 | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | 0 to 0xFFFFFFFF | 0x60BA0020 | - | RW | No | PREOP | Yes |
SubIndex 5 | Mapping entry 5 | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | 0 to 0xFFFFFFFF | 0x60FD0020 | - | RW | No | PREOP | Yes |
SubIndex 6 | Mapping entry 6 |
9. Object Dictionary
9-13
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | 0 to 0xFFFFFFFF | - | - | RW | No | PREOP | Yes |
SubIndex 7 | Mapping entry 7 | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | 0 to 0xFFFFFFFF | - | - | RW | No | PREOP | Yes |
SubIndex 8 | Mapping entry 8 | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | 0 to 0xFFFFFFFF | - | - | RW | No | PREOP | Yes |
SubIndex 9 | Mapping entry 9 | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | 0 to 0xFFFFFFFF | - | - | RW | No | PREOP | Yes |
SubIndex 10 | Mapping entry 10 | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | 0 to 0xFFFFFFFF | - | - | RW | No | PREOP | Yes |
Refer to the description of 0x1600.
0x1C00 | Sync Manager Communication Type | ||||||
SubIndex 0 | Number of entries | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
USINT | - | 4 | - | RO | No | - | No |
SubIndex 1 | Communication Type SM0 | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
USINT | - | 1 | - | RO | No | - | No |
SubIndex 2 | Communication Type SM1 | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
USINT | - | 2 | - | RO | No | - | No |
SubIndex 3 | Communication Type SM2 | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
USINT | - | 3 | - | RO | No | - | No |
SubIndex 4 | Communication Type SM3 | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
USINT | - | 4 | - | RO | No | - | No |
It represents the Sync Manager Communication Type assigned by default.
9. Object Dictionary
9-14
0x1C10 | Sync Manager 0 PDO Assignment | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | assignment PDO | attribute Change | Storage |
USINT | - | 0 | - | RO | No | - | No |
0x1C11 | Sync Manager 1 PDO Assignment | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | assignment PDO | attribute Change | Storage |
USINT | - | 0 | - | RO | No | - | No |
0x1C12 | Sync Manager 2 PDO Assignment | ||||||
SubIndex 0 | Number of entries | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
USINT | - | 1 | - | RW | No | - | No |
SubIndex 1 | Index of object assigned to PDO | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UINT | 0x1600 to 0x1603 | 0x1601 | - | RW | No | PREOP | No |
0x1C13 | Sync Manager 3 PDO Assignment | ||||||
SubIndex 0 | Number of entries | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
USINT | - | 1 | - | RW | No | - | No |
SubIndex 1 | Index of object assigned to PDO | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UINT | 0x1A00 to 0x1A03 | 0x1A01 | - | RW | No | PREOP | No |
0x1C32 | Output Sync Manager Parameter | ||||||
SubIndex 0 | Number of entries | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
USINT | - | 32 | - | RO | No | - | No |
SubIndex 1 | Sync mode | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UINT | - | - | - | RO | No | - | No |
SubIndex 2 | Cycle time | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | - | - | ns | RO | No | - | No |
SubIndex 3 | Shift time |
9. Object Dictionary
9-15
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | - | 0 | ns | RO | No | - | No |
SubIndex 4 | Sync modes supported | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UINT | - | 0x4007 | - | RO | No | - | No |
SubIndex 5 | Minimum cycle time | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | - | 250000 | ns | RO | No | - | No |
SubIndex 6 | Calc and copy time | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | - | 0 | ns | RO | No | - | No |
SubIndex 9 | Delay time | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | - | 0 | ns | RO | No | - | No |
SubIndex 10 | Sync0 time | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | - | 0 | ns | RO | No | - | No |
SubIndex 12 | SM event missed counter | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | - | 0 | - | RO | No | - | No |
SubIndex 13 | Shift too short counter | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | - | 0 | - | RO | No | - | No |
SubIndex 32 | Sync error | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
BOOL | - | 0 | - | RO | No | - | No |
0x1C33 | Input Sync Manager Parameter | ||||||
SubIndex 0 | Number of entries | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
USINT | - | 32 | - | RO | No | - | No |
SubIndex 1 | Sync mode | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UINT | - | - | - | RO | No | - | No |
SubIndex 2 | Cycle time |
9. Object Dictionary
9-16
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | - | - | ns | RO | No | - | No |
SubIndex 3 | Shift time | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | - | 0 | ns | RO | No | - | No |
SubIndex 4 | Sync modes supported | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UINT | - | 0x4007 | - | RO | No | - | No |
SubIndex 5 | Minimum cycle time | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | - | 250000 | ns | RO | No | - | No |
SubIndex 6 | Calc and copy time | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | - | 0 | ns | RO | No | - | No |
SubIndex 9 | Delay time | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | - | 0 | ns | RO | No | - | No |
SubIndex 10 | Sync0 time | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | - | 0 | ns | RO | No | - | No |
SubIndex 12 | SM event missed counter | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | - | 0 | - | RO | No | - | No |
SubIndex 13 | Shift too short counter | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UDINT | - | 0 | - | RO | No | - | No |
SubIndex 32 | Sync error | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
BOOL | - | 0 | - | RO | No | - | No |
9. Object Dictionary
9-17
9.2 Manufacturer Specific Objects
Basic Setting(0x2000~ )
0x2000 | Motor ID | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 1 to 9999 | 998 | - | RW | No | Power recycling |
Yes |
Set the motor ID. For the serial encoder provided by LSIS, it is automatically set. You can check the
automatically set IDs. You can check the motor ID on the motor nameplate.
Ex) The motor ID is 137 on the nameplate attached to the motor shown in the figure below:
0x2001 | Encoder Type | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 99 | 2 | - | RW | No | Power recycling |
Yes |
Set the encoder type. You have to set it correctly by referencing the table below. However, the serial
encoder provided by LSIS (4 in the table below) is automatically recognized and configured regardless
of these settings. Then, you can check the type of the encoder automatically recognized.
Setting values |
Encoder Type |
0 | Quadrature (incremental, A lead B) |
1 | Quadrature (incremental, B lead A) |
2 | BiSS Serial (single-turn only) |
3 | Reserved |
4 | BiSS Serial Absolute (multi-turn 16-bit) |
5~6 | Reserved |
7 | Sinusoidal(1Vpp) |
8 | Analog Hall |
9. Object Dictionary
9-18
9~10 | Reserved |
11 | Tamagawa Serial (single-turn only) |
12 | Tamagawa Serial Absolute (multi-turn 16-bit) |
13 | EnDat 2.2 Serial |
0x2002 | Encoder Pulse per Revolution | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UDINT | 0 to 1073741824 |
524288 | pulse | RW | No | recycling Power | Yes |
Set the encoder resolution in the unit of pulse (count) based on a multiple of 4. Generally, you can
check the encoder resolution on the nameplate (refer to the description of 0x2000). However, the serial
encoder provided by LSIS is automatically recognized and configured regardless of these settings.
Then, you can check the resolution of the encoder automatically recognized.
0x2003 | Node ID | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 65535 | - | - | RO | No | - | No |
Display the node ID configured for the node setting switch of the drive. The value of the node setting
switch is read just once when the power is turned on. Any set value modified subsequently will be in
effect only when the power is turned on again.
Ex) Example of setting the node ID to 10 (0x0A) and 15 (0x0F)
0 1 2
5 6
E F
8 9 A
7
ADDR
0x2004 | Rotation Direction Select | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 1 | 0 | - | RW | No | Power recycling |
Yes |
Set the rotation direction of the motor. You can change the rotation direction with this setting when the
direction is changed between positive and negative relative to the user at the final apparatus section.
Setting values |
Description |
0 | With a positive command, the motor rotates counterclockwise. Then, the position |
9. Object Dictionary
9-19
feedback value increases. | |
1 | With a positive command, the motor rotates clockwise. Then, the position feedback value increases. |
0x2005 | Absolute Encoder Configuration | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 1 | 1 | - | RW | No | Power recycling |
Yes |
Set the usage of the absolute encoder.
Setting values |
Description |
0 | Uses the absolute encoder as the absolute encoder. Uses the multi-turn data. |
1 | Uses the absolute encoder as the incremental encoder. Does not use the multi-turn data. Does not display any battery-related alarm/warning. |
0x2006 | Main Power Fail Check Mode | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 255 | 0 | - | RW | No | Always | Yes |
Specifies the main power input mode and the processing method if phase loss occurs.
Bit | Function | Value | Setting details |
3~0 | Sets the main power input. | 0 | Single-phase Power Input |
1 | 3-phase Power Input | ||
2 | DC power input | ||
7~4 | Processing method in case of main power phase loss |
0 | Processes the phase loss as alarm (AL-42) in case of main power phase loss. |
1 | Processes the phase loss as warning (W-01) in case of main power phase loss. |
0x2007 | Main Power Fail Check Time | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 5000 | 20 | ms | RW | No | Always | Yes |
(Reverse) (Forward)
9. Object Dictionary
9-20
This specifies the checking interval for main power phase loss. This function detects instantaneous
voltage drop or voltage sag, which may occur depending on the condition of external power input, to
check the main power phase loss. Set this function properly according to the condition of external
power input.
0x2008 | 7SEG Display Selection | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 100 | 0 | - | RW | Yes | Always | Yes |
This specifies items to display in the 7SEG window.
Setting values |
Displayed item | Unit | Description |
0 | Operation status | - | |
1 | Speed feedback | rpm, mm/s | |
2 | Speed command | rpm, mm/s | |
3 | Torque feedback | 0.1% | |
4 | Torque command | 0.1% | |
5 | Accumulated Operation Overload |
0.1% | |
6 | DC link voltage | V | |
7 | Accumulated Regeneration Overload |
0.1% | |
8 | Mechanical angle | 0.1deg | |
9 | Electrical angle | 0.1deg | |
10 | Inertia ratio | % | |
11 | Drive temperature 1 | °C | Temperature near the drive power element |
12 | Drive Temperature 2 | °C | Internal temperature of drive |
13 | Encoder temperature 1 | °C | Internal temperature of encoder |
14 | Node ID | - |
0x2009 | Regeneration Brake Resistor Configuration | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Stora ge |
UINT | 0 to 1 | 0 | - | RW | No | Always | Yes |
Perform regenerative resistance-related setting.
Setting values |
Description |
0 | Use the regenerative resistance installed in the drive. |
1 | Uses regenerative resistor separately installed outside the drive. Ensure that the value (0x200B) and capacity (0x200C) of the regenerative resistor are set correctly. For the wiring of the external regenerative resistor, refer to the wiring diagram of the power supply (2.3). |
9. Object Dictionary
9-21
0x200A | Regeneration Brake Resistor Derating Factor | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 200 | 100 | % | RW | No | Always | Yes |
This specifies the derating factor which checks for regenerative resistance overloads. When the
derating is set to a value no more than 100[%], regeneration overload alarm (AL-23) will be triggered
fast. On the other hand, when it is set to a value more than 100[%], the alarm will be triggered slowly.
Change the setting values according to the heat radiation condition of the regenerative resistor used.
Especially, when you set the derating to a value more than 100%, you have to consider the heat
radiation condition.
0x200B | Regeneration Brake Resistor Value | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 1000 | 0 | ohm | RW | No | Always | Yes |
When using an external regenerative resistor (0x2009=1), set the regenerative resistance in ohm.
When using an internal regenerative resistor (0x2009= 0), no setting values will be applied.
0x200C | Regeneration Brake Resistor Power | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 30000 | 0 | watt | RW | No | Always | Yes |
When using an external regenerative resistor (0x2009=1), set the regenerative resistance capacity in
watt. When using an internal regenerative resistor (0x2009= 0), no setting values will be applied.
0x200D | Peak Power of Regeneration Brake Resistor | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 1 to 50000 | 100 | watt | RW | No | Always | Yes |
When using an external regenerative resistor (0x2009=1), set the maximum allowable capacity of the
regenerative resistance in watt. When using an internal regenerative resistor (0x2009= 0), no setting
values will be applied.
0x200E | Duration Time @ Peak Power of Regeneration Brake Resistor | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 1 to 50000 | 5000 | ms | RW | No | Always | Yes |
When using an external regenerative resistor (0x2009=1), set the allowed time at the maximum
regenerative resistance capacity in watt. When using an internal regenerative resistor (0x2009= 0), no
setting values will be applied.
9. Object Dictionary
9-22
0x200F | Overload Check Base | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 10 to 120 | 100 | % | RW | No | Always | Yes |
This indicates the load factor at which operation overload starts to be accumulated. When this is set to
a value no more than 100, operation overload will start to be accumulated earlier at the set load factor
to result in early trigger of operation overload alarm (AL-21). If the heat radiation condition of the drive
is poor, configure the setting to no more than 100% to trigger an overload alarm earlier.
0x2010 | Overload Warning Level | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 10 to 100 | 50 | % | RW | No | Always | Yes |
This specifies the output level of accumulated operation overload warning (W10). When the
accumulated operation overload rate (0x2603) reaches the set value, a warning will be output. With this
setting, you can identify the time when you need to take an appropriate action before an accumulated
operation overload alarm occurs.
0x2011 | PWM Off Delay Time | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 1000 | 10 | ms | RW | No | Always | Yes |
This specifies the delay time until the PWM actually turns off after running servo off command. When
using a motor with a brake installed on the vertical axis, you can output the brake signal first, and then
turn off the PWM after this set time, in order to prevent it from running down along the axis.
0x2012 | Dynamic Brake Control Mode | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessi bility | assignment PDO | attribute Change | Storage |
UINT | 0 to 3 | 0 | - | RW | No | Always | Yes |
This specifies the control mode of the dynamic brake on servo off.
Setting values |
Description |
0 | Hold the dynamic brake after stopping the motor using the brake |
1 | Release the dynamic brake after stopping the motor using the brake |
2 | Release the dynamic brake after free-run stop |
3 | Hold the dynamic brake after free-run stop |
9. Object Dictionary
9-23
0x2013 | Emergency Stop Configuration | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 1 | 1 | - | RW | No | Always | Yes |
This specifies the method to do an emergency stop (when entering POT, NOT, or ESTOP) on the drive.
In the torque control mode, the decelerating to stop mode using the emergency stop torque is not
applied.
Setting values |
Description |
0 | The motor will stop according to the method set in the dynamic brake control mode (0x2012). It will stop using the dynamic brake, and then maintain the torque command at 0. |
1 | Decelerates to stop using the emergency stop torque (0x2113). |
0x2014 | Warning Mask Configuration | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to FFFFhex | 0 | - | RW | Yes | Always | Yes |
When a warning occurs, the warning masked by this setting will not be triggered.
Bit | Warning code |
Warning name/ Description |
0 | W01 | Main power phase loss |
1 | W02 | Low voltage of encoder battery |
Time
Time
Hold after a DB stop
Release after a DB stop Release after a free run stop
Hold after a free run stop
Time
Time
9. Object Dictionary
9-24
2 | W04 | Software Position Limit |
3 | W08 | - |
4 | W10 | Operation overload |
5 | W20 | Abnormal combination of drive and motor, abnormal I/O setting |
6 | W40 | Low voltage |
7 | W80 | Emergency signal input |
8~14 | - | - |
15 | STO | STO not connected Statusword fault bit set |
0x2015 | U Phase Current Offset | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
INT | -1000 to 1000 | 0 | 0.1% | RW | No | Always | Yes |
Manually set the U phase current offset. The configured offset value is subtracted from the measured
current value, and then applied as an actual current value. Do not manually set the offset if you do not
know the exact setting value. You can check the automatically-tuned value if you tune the current offset
with the procedure function (refer to the description of 0x2700).
0x2016 | V Phase Current Offset | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
INT | -1000 to 1000 | 0 | 0.1% | RW | No | Always | Yes |
Manually set the V phase current offset. The configured offset value is subtracted from the measured
current value, and then applied as an actual current value. Do not manually set the offset if you do not
know the exact setting value. You can check the automatically-tuned value if you tune the current offset
with the procedure function (refer to the description of 0x2700).
0x2017 | W Phase Current Offset | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
INT | -1000 to 1000 | 0 | 0.1% | RW | No | Always | Yes |
Manually set the W phase current offset. The configured offset value is subtracted from the measured
current value, and then applied as an actual current value. Do not manually set the offset if you do not
know the exact setting value. You can check the automatically-tuned value if you tune the current offset
with the procedure function (refer to the description of 0x2700).
For a drive with small to medium capacity (7.5 KW or less), this parameter is not used since the W
phase current is not separately measured.
9. Object Dictionary
9-25
0x2018 | Magnetic Pole Pitch | ALL | |||||
Variable type |
Setting range |
Initial value |
Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 1 to 65535 | 2400 | .01mm | RW | No | Power recycling |
Yes |
This specifies the pitch between the magnetic poles of the linear motor. The pole pitch refers to the
distance between the north poles or between the south poles of magnet, corresponding to 360˚ of
electrical angle.
0x2019 | Linear Scale Resolution | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 1 to 65535 | 1000 | nm | RW | No | Power recycling |
Yes |
Set Linear Scale Resolution in nm. For a linear scale with the resolution of 1 um, set it to 1000 (= 1 um
/ 1 nm).
0x201A | Commutation Method | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 2 | 0 | - | RW | No | Power recycling |
Yes |
This specifies the commutation method to get the information on the initial angle of motor.
Setting values | Description |
0 | Not necessary for separate commutation or carry out commutation using a hall sensor. |
1 | Carry out commutation when the servo is turned on for the first time. |
2 | Reserved |
0x201B | Commutation Current | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 1000 | 500 | 0.1% | RW | No | Always | Yes |
0x201C | Commutation Time | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 500 to 5000 | 1000 | ms | RW | No | Always | Yes |
9. Object Dictionary
9-26
0x201D | Grating Period of Sinusoidal Encoder | ALL | |||||
Variable type |
Setting range | Initial value |
Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UINT | 1 to 65535 | 40 | um | RW | No | Power recycling |
Yes |
Set grid of sinusoidal encoder
0x201E | Homing Done Behaviour | ALL | |||||
Variable type |
Setting range | Initial value |
Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UINT | 0 to 1 | 0 | - | RW | No | Always | Yes |
Set movement towards Zero position according to home offset [0x607C].
Setting values | Description |
0 | Motor will not move and home offset [0x607C] value will be zero position after homing by homing method [0x6098] |
1 | Motor will be rotate as much as home offset and zero offset will be 0, after homming by homing method [0x6098] |
0x201F | Velocity Function Select | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 2 | 0 | - | RW | No | Always | Yes |
Select the method to calculate feedback speed when encoder type is Quadrature.
Setting values | Description |
0 | MT Method + Speed Observer |
1 | MT Method |
2 | M Method |
9. Object Dictionary
9-27
0x2020 | Motor Hall Phase Config | ALL | |||||
Variable type |
Setting range | Initial value |
Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
UINT | 0 to 1 | 0 | - | RW | No | Power recycling |
Yes |
Checking the motor wiring and hall sensor wiring in case of 3rd party motor and Setting the
sequence of hall sensor UVW, polarity of hall sensor signal and motor rotation direction.
Setting values | Description |
0 | Setting direction of rotation of motor (0x2004’s setting values and Exclusive OR operation.) |
1~7 | Reserved |
8 | Hall U polarity reversal |
9 | Hall V polarity reversal |
10 | Hall W polarity reversal |
11 | Reserved |
12 | Hall U, Hall V replace |
13 | Hall V, Hall W replace |
14 | Hall W, Hall U replace |
15 | Reserved |
9. Object Dictionary
9-28
Gain Adjustment(0x2100~ )
0x2100 | Inertia Ratio | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 3000 | 100 | % | RW | No | Always | Yes |
This specifies the ratio of the load inertia to the motor's rotor inertia in %.
Inertia ratio = Load inertia / Motor's rotor inertia x 100
The inertia/load ratio is an important control parameter for the operation of the servo. It is crucial to
set the correct inertia ratio for optimal servo operation. You can estimate the inertia ratio by auto gain
tuning. The ratio will be continuously estimated during operation if you carry out real-time gain tuning.
0x2101 | Position Loop Gain 1 | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 1 to 500 | 50 | 1/s | RW | Yes | Always | Yes |
This specifies the whole responsiveness of the position controller. The larger the setting is configured,
the higher the responsiveness is. Too large setting value may cause vibration depending on the load.
0x2102 | Speed Loop Gain 1 | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 1 to 2000 | 75 | Hz | RW | Yes | Always | Yes |
This specifies the whole responsiveness of the speed controller. To make the whole responsiveness of
the system higher, you have to set the speed loop gain large as well, along with the position loop gain.
Too large setting value may cause vibration depending on the load.
0x2103 | Speed Loop Integral Time Constant 1 | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 1 to 1000 | 50 | ms | RW | Yes | Always | Yes |
This specifies the integral time constant of the speed controller. If you set a large value, error will be
reduced at a steady state (while stopped or driving at a constant speed), but vibration may occur at a
transient state (while accelerating or decelerating).
0x2104 | Torque Command Filter Time Constant 1 | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 1000 | 5 | 0.1ms | RW | Yes | Always | Yes |
This applies a low pass filter for torque command. You can improve the system stability by setting an
appropriate value to smoothen the torque command. If you set it too large, the delay for the torque
command will be longer, reducing the system responsiveness.
9. Object Dictionary
9-29
0x2105 | Position Loop Gain 2 | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 1 to 500 | 30 | /s | RW | Yes | Always | Yes |
This specifies the position loop gain used as gain group 2 for gain switching. For more information,
refer to the description of the Position Loop Gain 1 (0x2101).
0x2106 | Speed Loop Gain 2 | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 1 to 2000 | 50 | Hz | RW | Yes | Always | Yes |
This specifies the speed loop gain used as gain group 2 for gain switching. For more information, refer
to the description of the Speed Loop Gain 1 (0x2102).
0x2107 | Speed Loop Integral Time Constant 2 | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 1 to 1000 | 50 | ms | RW | Yes | Always | Yes |
This specifies the integral time constant of the speed loop used as gain group 2 for gain switching. For
more information, refer to the description of the Speed Loop Integral Time Constant 1 (0x2103).
0x2108 | Torque Command Filter Time Constant 2 | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 1000 | 0 | 0.1ms | RW | Yes | Always | Yes |
This specifies the time constant of the torque command filter used as gain group 2 for gain switching.
For more information, refer to the description of the Torque Command Filter Time Constant 1 (0x2104).
0x2109 | Position Command Filter Time Constant | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 10000 | 0 | 0.1ms | RW | Yes | Always | Yes |
This applies a low pass filter for position command to smoothen the position command. Especially, this
can be used for setting a higher gear ratio.
9. Object Dictionary
9-30
0x210A | Position Command Average Filter Time Constant | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 10000 | 0 | 0.1ms | RW | Yes | Always | Yes |
This applies a moving average filter for position command to smoothen the position command. The
value of Position Command Filter Time Constant (0x2109) is first applied. Position Command Average
Filter Time Constant (0x210A) is only applied if the value is 0.
0x210B | Speed Feedback Filter Time Constant | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 1000 | 5 | 0.1ms | RW | Yes | Always | Yes |
This applies a low pass filter to the speed feedback signal calculated from the encoder. In case that
system vibration occurs or vibration occurs when a gain load with too large of an inertia is applied, you
can suppress the vibration by setting appropriate value.
0x210C | Velocity Feed-forward Gain | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 100 | 0 | % | RW | Yes | Always | Yes |
This specifies the feedforward gain for the speed command during position control. The larger the
setting is, the less the positional error is. If you set a too large value depending on the load, vibration or
overshoot may occur. For gain tuning, increase the setting value gradually.
0x210D | Velocity Feed-forward Filter Time Constant | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 1000 | 10 | 0.1 ms |
RW | Yes | Always | Yes |
This applies low pass filter to the compensated amount added to the speed command by the speed
feedforward gain. You can enhance the system stability by using it when you set a large speed
feedforward gain or when there is excessive change in position command.
0x210E | Torque Feed-forward Gain | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 100 | 0 | % | RW | Yes | Always | Yes |
This specifies the feedforward gain for the torque command during speed control.
9. Object Dictionary
9-31
0x210F | Torque Feed-forward Filter Time Constant | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 1000 | 10 | 0.1 ms |
RW | Yes | Always | Yes |
This applies low pass filter to the compensated amount added to the torque command by the torque
feed-forward gain.
0x2110 | Torque Limit Function Select | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 4 | 2 | - | RW | Yes | Always | Yes |
This specifies the function to limit the output torque of the drive.
Setting values |
Description |
0 | Limits the torque using positive/negative torque limit value according to the driving direction; the maximum value is limited by the maximum torque (0x6072). - Forward: 0x60E0, Reverse: 0x60E1 |
1 | Limits the torque only by the maximum torque (0x6072) regardless of the driving direction. |
2 | Limits the torque using external positive/negative torque limit value according to the driving direction. - Forward: 0x2111, Reverse: 0x2112 |
3 | Limits the torque using internal and external torque limit value according to the driving direction and the torque limit signal. - Forward: 0x60E0(if P_CL signal is not input), 0x2111(if P_CL signal is input) - Reverse: 0x60E1(if N_CL signal is not input), 0x2112(if N_CL signal is input) |
4 | Limited by the analog input torque limit. - Refer to analog torque limit scale (0x221C) and offset (0x221D) |
0x2111 | External Positive Torque Limit Value | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 5000 | 3000 | 0.1% | RW | Yes | Always | Yes |
This specifies the external positive torque limit value according to the torque limit function setting
(0x2110).
9. Object Dictionary
9-32
0x2112 | External Negative Torque Limit Value | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 5000 | 3000 | 0.1% | RW | Yes | Always | Yes |
This specifies the external negative torque limit value according to the torque limit function setting
(0x2110).
0x2113 | Emergency Stop Torque | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 5000 | 1000 | 0.1% | RW | Yes | Always | Yes |
This specifies the stop torque on emergency stop (when entering POT, NOT, or ESTOP).
0x2114 | P/PI Control Conversion Mode | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 4 | 0 | - | RW | Yes | Always | Yes |
This specifies the switch mode between PI control and P control. Using this function, you can improve
the speed control characteristic to reduce the overshoot during speed operation and the positioning
time during position operation.
Setting values | Setting details |
0 | Always uses the PI control. |
1 | Switches to the P control if the command torque is larger than the P control switching torque (0x2115). |
2 | Switches to the P control if the command speed is larger than the P control switching speed (0x2116). |
3 | Switches to the P control if the acceleration command is larger than the P control switching acceleration (0x2117). |
4 | Switches to the P control if the position error is larger than the P control switching position error (0x2118). |
0x2115 | P Control Switch Torque | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 5000 | 500 | 0.1% | RW | Yes | Always | Yes |
Refer to the description of the P/PI control switching mode (0X2114).
9. Object Dictionary
9-33
0x2116 | P Control Switch Speed | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 6000 | 100 | rpm | RW | Yes | Always | Yes |
Refer to the description of the P/PI control switching mode (0X2114).
0x2117 | P Control Switch Acceleration | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 60000 | 1000 | rpm/s | RW | Yes | Always | Yes |
Refer to the description of the P/PI control switching mode (0X2114).
0x2118 | P Control Switch Following Error | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 60000 | 100 | pulse | RW | Yes | Always | Yes |
Refer to the description of the P/PI control switching mode (0X2114).
0x2119 | Gain Conversion Mode | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 7 | 0 | - | RW | Yes | Always | Yes |
You can enhance the performance of the entire system by switching between two gain groups.
According to the switching mode, manual switch or automatic switch can be done depending on the
external input or output signal, respectively.
Gain group 1 | Gain group 2 |
Position loop gain 1 (0x2101) Speed loop gain 1 (0x2102) Speed loop integral time constant 1 (x2103) Torque command filter time constant 1 (0x2104) |
Position loop gain 2 (0x2105) Speed loop gain 2 (0x2106) Speed loop integral time constant 2 (x2107) Torque command filter time constant 2(0x2108) |
Setting values | Setting details |
0 | Only the gain group 1 is used. |
1 | Only the gain group 2 is used. |
2 | Gain is switched according to the GAIN2 input status. - 0: Use gain group 1 |
9. Object Dictionary
9-34
- 1: Use gain group 2 | |
3 | Reserved |
4 | Reserved |
5 | Reserved |
6 | Gain is switched according to the ZSPD output status. - 0: Use gain group 1 - 1: Use gain group 2 |
7 | Gain is switched according to the INPOS1 output status. - 0: Use gain group 1 - 1: Use gain group 2 |
0x211A | Gain Conversion Time 1 | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 1000 | 2 | ms | RW | Yes | Always | Yes |
This specifies the time to switch from gain group 1 to gain group 2.
0x211B | Gain Conversion Time 2 | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 1000 | 2 | ms | RW | Yes | Always | Yes |
This specifies the time to switch from gain group 2 to gain group 1.
0x211C | Gain Conversion Waiting Time 1 | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 1000 | 0 | ms | RW | Yes | Always | Yes |
This specifies the waiting time before switching from gain group 1 to gain group 2.
0x211D | Gain Conversion Waiting Time 2 | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 1000 | 0 | ms | RW | Yes | Always | Yes |
This specifies the waiting time before switching from gain group 2 to gain group 1.
9. Object Dictionary
9-35
0x211E | Dead Band for Position Control | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 1000 | 0 | UU | RW | Yes | Always | Yes |
The position controller output is 0 if positional error for position control is below the setting.
0x211F | Drive Control Input 1 | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to FFFFhex | 0 | - | RW | Yes | Always | No |
You can input the signal required for drive control via the I/O. Using a remote I/O, you can indirectly
input the control input signal, inputted to the upper level controller, to the drive through this setting.
An applicable function will be performed by logical OR operation of the signal input through I/O and the
bit value of this setting.
Bit | Setting details |
0 | POT |
1 | NOT |
2 | HOME |
3 | STOP |
4 | PCON |
5 | GAIN2 |
6 | P_CL |
7 | N_CL |
8 | PROBE1 |
9 | PROBE2 |
10 | EMG |
11 | A_RST |
12 | SV_ON |
13 | LVSF1 |
14 | LVSF2 |
15 | Reserved |
0x2120 | Drive Control Input 2 | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to FFFFhex | 0 | - | RW | Yes | - | No |
Bit | Setting details |
15-0 | Reserved |
9. Object Dictionary
9-36
0x2121 | Drive Status Output 1 | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to FFFFhex | 0 | - | RW | Yes | Always | No |
You can assign the state of the drive output signal to the I/O output signal, in order to verify the
applicable bit of this output value, in addition to actual output.
Bit | Setting details |
0 | BRAKE |
1 | ALARM |
2 | READY |
3 | ZSPD |
4 | INPOS1 |
5 | TLMT |
6 | VLMT |
7 | INSPD |
8 | WARN |
9 | TGON |
10 | INPOS2 |
15-11 | Reserved |
0x2122 | Drive Status Output 2 | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to FFFFhex | 0 | - | RO | Yes | - | No |
Bit | Setting details |
15-0 | Reserved |
9. Object Dictionary
9-37
I/O Configuration (from 0x2200)
0x2200 | Digital Input Signal 1 Selection | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 0xFFFF | 0x0001 | - | RW | No | Always | Yes |
This specifies the functions of digital input signal 1 of the I/O and the input signal level.
Setting example) If the setting value is 0x006:
0 0 0 6
Contact A GAIN2 assigned
0x2201 | Digital Input Signal 2 Selection | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 0xFFFF | 0x0002 | - | RW | No | Power recycling |
Yes |
Setting values 0x00 0x01 0x02 0x03 0x04 0x05 0x06 0x07 0x08 0x09 0x0A 0x0B 0x0C |
Assigned signal Not assigned POT NOT HOME STOP PCON GAIN2 P_CL N_CL PROBE1 PROBE2 EMG A_RST |
This specifies the functions of digital input signal 2 of the I/O and the input signal level. For more
information, refer to the description of 0x2200.
0x2202 | Digital Input Signal 3 Selection | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 0xFFFF | 0x0003 | - | RW | No | Power recycling |
Yes |
This specifies the functions of digital input signal 3 of the I/O and the input signal level. For more
information, refer to the description of 0x2200.
Bit Setting details
15
Signal input level settings
(0: contact A, 1: contact B)
14~8 Reserved
7~0 Assign input signal.
9. Object Dictionary
9-38
0x2203 | Digital Input Signal 4 Selection | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 0xFFFF | 0x0004 | - | RW | No | Power recycling |
Yes |
This specifies the functions of digital input signal 4 of the I/O and the input signal level. For more
information, refer to the description of 0x2200.
0x2204 | Digital Input Signal 5 Selection | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 0xFFFF | 0x0005 | - | RW | No | Power recycling |
Yes |
This specifies the functions of digital input signal 5 of the I/O and the input signal level. For more
information, refer to the description of 0x2200.
0x2205 | Digital Input Signal 6 Selection | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 0xFFFF | 0x0006 | - | RW | No | Power recycling |
Yes |
This specifies the functions of digital input signal 6 of the I/O and the input signal level. For more
information, refer to the description of 0x2200.
0x2206 | Digital Input Signal 7 Selection | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 0xFFFF | 0x0007 | - | RW | No | Power recycling |
Yes |
This specifies the functions of digital input signal 7 of the I/O and the input signal level. For more
information, refer to the description of 0x2200.
0x2207 | Digital Input Signal 8 Selection | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 0xFFFF | 0x0008 | - | RW | No | Power recycling |
Yes |
This specifies the functions of digital input signal 8 of the I/O and the input signal level. For more
information, refer to the description of 0x2200.
9. Object Dictionary
9-39
0x2210 | Digital Output Signal 1 Selection | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 0xFFFF | 0x8001 | - | RW | No | Power recycling |
Yes |
Assign the functions of digital output signal 1 of I/O and set the output signal level.
Setting example) If the setting value is 0x8001:
8 0 0 1
Contact B Brake assigned
0x2211 | Digital Output Signal 2 Selection | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 0xFFFF | 0x8002 | - | RW | No | Power recycling |
Yes |
Setting values 0x00 0x01 0x02 0x03 0x04 0x05 0x06 0x07 0x08 0x09 0x0A 0x0B |
Assigned signal Not assigned BRAKE ALARM READY ZSPD INPOS1 TLMT VLMT INSPD WARN TGON INPOS2 |
Assign the functions of digital output signal 2 of I/O and set the output signal level. For more
information, refer to the description of 0x2210.
0x2212 | Digital Output Signal 3 Selection | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 0xFFFF | 0x0003x | - | RW | No | Power recycling |
Yes |
Assign the functions of digital output signal 3 of I/O and set the output signal level. For more
information, refer to the description of 0x2210.
0x2213 | Digital Output Signal 4 Selection | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 0xFFFF | 0x0004 | - | RW | No | Power recycling |
Yes |
Bit Setting details
15
Signal output level settings
(0: contact A, 1: contact B)
14~8 Reserved
7~0 Assign output signal
9. Object Dictionary
9-40
Assign the functions of digital output signal 4 of I/O and set the output signal level. For more
information, refer to the description of 0x2210.
0x221C | Analog Torque Limit Scale | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 0xFFFF | 300 | 0.1%/V | RW | No | Always | Yes |
If the value of torque limit function setting (0x2110) is 4 (analog torque limit), torque is limited by the
analog input torque limit. Set the scale of the analog input value at this time.
0x221D | Analog Torque Limit Offset | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
INT | -1000 to 1000 | 0 | mV | RW | No | Always | Yes |
This specifies the analogue voltage offset controlled by the analogue torque limit
0x2220 | Analog Monitor Output Mode | P | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 1 | 0 | - | RW | No | Always | Yes |
The output range of analog monitor is from -10 V to +10 V. If the setting is 1, take the absolute value of
the output to make the output value only be positive.
Setting values | Setting details |
0 | Output as negative/positive values |
1 | Output only as positive values |
0x2221 | Analog Monitor Channel 1 Select | P | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 65535 | 0 | - | RW | No | Always | Yes |
Configure the monitoring variables to be output to the analog monitor output channel 1.
Setting values | Displayed item | Unit |
0 | Speed feedback | rpm |
1 | Speed command | rpm |
2 | Speed error | rpm |
9. Object Dictionary
9-41
3 | Torque feedback | % |
4 | Torque command | % |
5 | Positional Error | pulse |
6 | Accumulated Operation Overload | % |
7 | DC link voltage | V |
8 | Accumulated Regeneration Overload | % |
9 | Encoder single-turn data | pulse |
10 | Inertia Ratio | % |
11 | Full-Closed positional error | UU |
12 | Drive Temperature 1 | °C |
13 | Drive Temperature 2 | °C |
14 | Encoder temperature 1 | °C |
0x2222 | Analog Monitor Channel 2 Select | P | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 65535 | 1 | - | RW | No | Always | Yes |
Configure the monitoring variables to be output to the analog monitor output channel 2.
0x2223 | Analog Monitor Channel 1 Offset | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
DINT | 0 to 0x40000000 | 0 | - | RW | No | Always | Yes |
Subtract the offset value from the monitoring variable of the analog monitor output channel 1 to
determine the final output. The unit will be that of the variable configured in the Analog Monitor Channel
1 Setting (0x2221).
0x2224 | Analog Monitor Channel 2 Offset | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
DINT | 0 to 0x40000000 |
0 | - | RW | No | Always | Yes |
Subtract the offset value from the monitoring variable of the analog monitor output channel 2 to
determine the final output. The unit will be that of the variable configured in the Analog Monitor Channel
2 Setting (0x2222).
9. Object Dictionary
9-42
0x2225 | Analog Monitor Channel 1 Scale | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UDINT | 0 to 0x40000000 |
500 | - | RW | No | Always | Yes |
This specifies the scaling of the variable to be output per 1 V when outputting the monitoring variable
configured as the analog output channel 1. The unit will be that of the variable configured in the Analog
Monitor Channel 1 Setting (0x2221) per 1 V.
For example, if you set the speed feedback to the channel 1 and the scale to 500, up to +/-5000 rpm
can be output as +/-10 V.
0x2226 | Analog Monitor Channel 2 Scale | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UDINT | 0 to 0x40000000 |
500 | - | RW | No | Always | Yes |
This specifies the scaling of the variable to be output per 1 V when outputting the monitoring variable
configured as the analog output channel 2. The unit will be that of the variable configured in the Analog
Monitor Channel 2 Setting (0x2222) per 1 V.
9. Object Dictionary
9-43
Velocity Control(0x2300~ )
0x2300 | Jog Operation Speed | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
INT | -6000 to 6000 | 500 | rpm, | RW | No | Always | Yes |
This specifies the jog operation speed.
0x2301 | Speed Command Acceleration Time | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 10000 | 200 | ms | RW | No | Always | Yes |
Specifies the time required, in ms, for the motor to reach the rated motor speed from zero speed.
0x2302 | Speed Command Deceleration Time | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 10000 | 200 | ms | RW | No | Always | Yes |
This specifies the time, in ms, required for the motor to decelerate from the rated motor speed to the
stop.
0x2303 | Speed Command S-curve Time | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 1000 | 0 | ms | RW | No | Always | Yes |
You can configure the speed command in an S-curve pattern for smooth acceleration/deceleration. If it
is set to 0, the drive will be operated in a trapezoidal pattern by default.
0x2304 | Program Jog Operation Speed 1 | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
INT | -6000 to 6000 | 0 | rpm | RW | No | Always | Yes |
For programmed jog operation, you can set the operation speed 1 to 4 and the operation time 1 to 4 as
follows:
9. Object Dictionary
9-44
0x2305 | Program Jog Operation Speed 2 | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
INT | -6000 to 6000 | 500 | rpm | RW | No | Always | Yes |
Refer to the description of Programmed Jog Operation Speed 1 (0x2304).
0x2306 | Program Jog Operation Speed 3 | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
INT | -6000 to 6000 | 0 | rpm | RW | No | Always | Yes |
Refer to the description of Programmed Jog Operation Speed 1 (0x2304).
0x2307 | Program Jog Operation Speed 4 | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
INT | -6000 to 6000 | -500 | rpm | RW | No | Always | Yes |
Refer to the description of Programmed Jog Operation Speed 1 (0x2304).
0x2308 | Program Jog Operation Time 1 | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 10000 | 500 | ms | RW | No | Always | Yes |
Refer to the description of Programmed Jog Operation Speed 1 (0x2304).
0x2309 | Program Jog Operation Time 2 | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 10000 | 5000 | ms | RW | No | Always | Yes |
Refer to the description of Programmed Jog Operation Speed 1 (0x2304).
9. Object Dictionary
9-45
0x230A | Program Jog Operation Time 3 | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 10000 | 500 | ms | RW | No | Always | Yes |
Refer to the description of Programmed Jog Operation Speed 1 (0x2304).
0x230B | Program Jog Operation Time 4 | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 10000 | 5000 | ms | RW | No | Always | Yes |
Refer to the description of Programmed Jog Operation Speed 1 (0x2304).
0x230C | Index Pulse Search Speed | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
INT | -1000 to 1000 | 20 | rpm | RW | No | Always | Yes |
This specifies the speed for index pulse search.
0x230D | Speed Limit Function Select | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 3 | 0 | - | RW | No | Always | Yes |
This specifies the speed limit function for torque control.
Setting values | Setting details |
0 | Limited by speed limit value (0x230E) |
1 | Limited by the maximum motor speed |
0x230E | Speed Limit Value at Torque Control Mode | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 6000 | 1000 | rpm | RW | Yes | Always | Yes |
This specifies the speed limit value for torque control. This setting is applied only when the Speed Limit
Function Setting (0x230D) is set to 0.
9. Object Dictionary
9-46
0x230F | Over Speed Detection Level | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 10000 | 6000 | rpm | RW | No | Always | Yes |
This specifies the level to detect overspeed alarms (AL-50). If the setting is larger than the maximum
motor speed, the detection level will be set by the maximum motor speed.
0x2310 | Excessive Speed Error Detection Level | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 10000 | 5000 | rpm | RW | No | Always | Yes |
This specifies the level to detect excessive speed error alarms (AL-53). If the difference between the
speed command and the speed feedback exceeds the setting value, an excessive speed error alarm is
generated.
0x2311 | Servo-Lock Function Select | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 1 | 0 | - | RW | No | Always | Yes |
This specifies the servo-lock function to fix the motor position with a position value when the speed
command is input as 0 for speed control.
Setting values | Setting details |
0 | Servo-lock function disabled |
1 | Servo-lock function enabled |
9. Object Dictionary
9-47
Miscellaneous Setting(0x2400~ )
0x2400 | Software Position Limit Function Select | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 3 | 0 | - | RW | No | Always | Yes |
This specifies the software position limit function for position control. When using the position limit
function, the upper and the lower limit values will be limited to the values configured in (0x670D:02)
and (0x670D:01), respectively. The software position limit function will not be activated prior to the
homing operation. In addition, when the upper limit value is less than the lower limit value, this function
will not be activated.
Setting values | Setting details |
0 | None of positive and negative software position limits are used. |
1 | Only positive software position limit value is used. It is not limited for the reverse direction. |
2 | Only negative software position limit value is used. It is not limited for the forward direction. |
3 | Both of the positive and the negative software position limits are used. |
0x2401 | INPOS1 Output Range | P | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 60000 | 100 | UU | RW | Yes | Always | Yes |
With the position command not newly updated, if the positional error is retained within the INPOS1
output range for the INPOS1 output time, the INPOS1 signal is output.
0x2402 | INPOS1 Output Time | P | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 1000 | 0 | ms | RW | Yes | Always | Yes |
Refer to the description of 0x2401.
0x2403 | INPOS2 Output Range | P | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 60000 | 100 | UU | RW | Yes | Always | Yes |
This outputs the INPOS2 signal where the positional error is less than the setting value. Unlike the
INPOS1, the INPOS2 signal is output by calculating only the positional error value.
9. Object Dictionary
9-48
0x2404 | ZSPD Output Range | P | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 6000 | 10 | rpm | RW | Yes | Always | Yes |
When the current speed is less than the setting value, the ZSPD signal is output.
0x2405 | TGON Output Range | P | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 6000 | 100 | rpm | RW | Yes | Always | Yes |
When the current speed is more than the setting value, the TGON signal is output.
0x2406 | INSPD Output Range | P | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 6000 | 100 | rpm | RW | Yes | Always | Yes |
When the speed error is less than the setting value, the INSPD signal is output.
0x2407 | BRAKE Output Speed | P | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 6000 | 100 | rpm | RW | No | Always | Yes |
If the motor stops due to servo OFF or servo alarm during rotation, you can set the speed (0x2407) and
delay time (0x2408) for brake signal output, in order to configure the output timing. The brake signal
will be output if the motor rotation speed goes below the set speed (0x2407) or the output delay time
(0x2408) has elapsed after the servo OFF command.
0x2408 | BRAKE Output Delay Time | P | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 1000 | 100 | ms | RW | No | Always | Yes |
Refer to the description of 0x2407.
9. Object Dictionary
9-49
0x2409 | Torque Limit for Homing Using Stopper | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 2000 | 250 | 0.1% | RW | No | Always | Yes |
This specifies the torque limit value for homing using a stopper. With too large of a value configured,
the machine may collide with the stopper. So be careful.
0x240A | Duration Time for Homing Using Stopper | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 1000 | 50 | ms | RW | No | Always | Yes |
This specifies the time to detect the stopper for homing using a stopper. Set an appropriate value,
depending on the machine.
0x240B | Modulo Mode | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 3 | 0 | - | RW | No | Power recycling |
Yes |
This specifies whether to use the Modulo function.
Setting values | Setting details |
0 | Does not use the Modulo function. |
1 | Uses the Modulo function to move forward. |
2 | Uses the Modulo function to move backward. |
3 | Uses the Modulo function to move via the possible shortest distance. |
4 | Uses the Modulo function to move to the absolute position. |
5 | Uses the Modulo function to move to the relative position. |
0x240C | Modulo Factor | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
DINT | 1 to 0x3FFFFFFF |
3600 | UU | RW | No | recycling Power | Yes |
This specifies the factor for using the Modulo function.
9. Object Dictionary
9-50
0x240D | User Drive Name | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
STRING | - | ‘Drive’ | UU | RW | No | Always | Yes |
The user can customize the drive name. Up to 16 characters can be used to define the name.
0x240E | Individual Parameter Storage | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
DINT | 0 to 1 | 0 | - | RW | No | Always | No |
This specifies whether to save parameters individually. This parameter is not saved and initialized to 0
during power ON.
Setting values | Setting details |
0 | Parameters are not saved individually. For details on storing a parameter, refer to Storing Parameters (0x1010). |
1 | Save the parameters individually. When a parameter is written, it is immediately stored in the memory. |
9. Object Dictionary
9-51
Enhanced Control(0x2500~ )
0x2500 | Adaptive Filter Function Select | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 5 | 0 | - | RW | No | Always | Yes |
This specifies the adaptive filter function.
Setting values | Setting details |
0 | Adaptive filter is not used. |
1 | Only one adaptive filter is used. You can check the settings configured automatically in the Notch Filter 4 Settings (0x250A and 0x250B). |
2 | Only two adaptive filters are used. You can check the settings configured automatically in the Notch Filter 3 (0x2507 and 0x2508) and 4 Settings (0x250A and 0x250B). |
3~5 | Reserved |
0x2501 | Notch Filter 1 Frequency | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 50 to 5000 | 5000 | Hz | RW | No | Servo off | Yes |
This specifies the frequency of the notch filter 1.
0x2502 | Notch Filter 1 Width | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 1 to 100 | 1 | Hz | RW | No | Servo off | Yes |
This specifies the width of the notch filter 1.
0x2503 | Notch Filter 1 Depth | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 1 to 5 | 1 | - | RW | No | Servo off | Yes |
This specifies the depth of the notch filter 1.
9. Object Dictionary
9-52
0x2504 | Notch Filter 2 Frequency | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 50 to 5000 | 5000 | Hz | RW | No | Servo off | Yes |
0x2505 | Notch Filter 2 Width | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 1 to 100 | 1 | Hz | RW | No | Servo off | Yes |
0x2506 | Notch Filter 2 Depth | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 1 to 5 | 1 | - | RW | No | Servo off | Yes |
0x2507 | Notch Filter 3 Frequency | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 50 to 5000 | 5000 | Hz | RW | No | Servo off | Yes |
0x2508 | Notch Filter 3 Width | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 1 to 100 | 1 | Hz | RW | No | Servo off | Yes |
0x2509 | Notch Filter 3 Depth | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 1 to 5 | 1 | - | RW | No | Servo off | Yes |
0x250A | Notch Filter 4 Frequency | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 50 to 5000 | 5000 | Hz | RW | No | Servo off | Yes |
9. Object Dictionary
9-53
0x250B | Notch Filter 4 Width | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 1 to 100 | 1 | Hz | RW | No | Servo off | Yes |
0x250C | Notch Filter 4 Depth | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 1 to 5 | 1 | - | RW | No | Servo off | Yes |
0x250D | On-line Gain Tuning Mode | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 1 | 0 | - | RW | No | Servo off | Yes |
This specifies the On-line Gain Tuning Mode.
Setting values | Setting details |
0 | On-line Gain Tuning not used |
1 | On-line Gain Tuning used |
0x250E | System Rigidity for Gain Tuning | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 1 to 20 | 5 | - | RW | No | Servo off | Yes |
This specifies the system rigidity applied for gain tuning. After the gain tuning according to the setting,
the overall gain will be set higher or lower. If the gain of the maximum setting value is not enough, carry
out the tuning manually. After the gain tuning, the following gains will be automatically changed:
Inertia ratio (0x2100), position loop gain 1 (0x2001), speed loop gain 1 (0x2102), speed integral time
constant 1 (0x2103), torque command filter time constant 1 (0x2104), notch filter 3 frequency (0x2507,
TBD), and notch filter 4 frequency (0x250A, TBD).
0x250F | On-line Gain Tuning Adaptation Speed | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 1 to 5 | 1 | - | RW | No | Servo off | Yes |
This specifies the speed reflecting the change of gain when performing on-line gain tuning. The larger
the setting value is, the faster the change of gain is reflected.
9. Object Dictionary
9-54
0x2510 | Off-line Gain Tuning Direction | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 1 | 0 | - | RW | No | Servo off | Yes |
This specifies the movement direction when performing the Off-line Gain Tuning. Set the function
properly according to the condition of the apparatus section.
Setting values | Setting details |
0 | Drive in the forward direction |
1 | Drive in the reverse direction |
0x2511 | Off-line Gain Tuning Distance | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 1 to 10 | 5 | - | RW | No | Servo off | Yes |
It specifies the distance when performing the off-line gain tuning. The larger the setting value is, the
longer the movement distance becomes. Set the distance properly according to the condition of the
apparatus section. Make sure to secure enough distance (more than one revolution of motor) prior to
gain tuning.
0x2512 | Disturbance Observer Gain | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 100 | 50 | % | RW | No | Servo off | Yes |
(It will be supported later)
0x2513 | Disturbance Observer Filter Time Constant | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 1000 | 10 | 0.1 ms |
RW | No | Servo off | Yes |
(It will be supported later)
0x2514 | Current Controller Gain | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 1 to 150 | 100 | % | RW | No | Servo off | Yes |
This specifies the current controller gain. Lowering the setting value will reduce the noise, but the
drive's responsiveness decreases as well.
9. Object Dictionary
9-55
0x2515 | Vibration Suppression Filter Configuration | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 5 | 0 | - | RW | No | Servo off | Yes |
(Description will be added later)
0x2516 | Vibration Suppression Filter 1 Frequency | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 2000 | 0 | 0.1Hz | RW | No | Servo off | Yes |
0x2517 | Vibration Suppression Filter 1 Damping | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 5 | 0 | - | RW | No | Servo off | Yes |
0x2518 | Vibration Suppression Filter 2 Frequency | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 2000 | 0 | 0.1Hz | RW | No | Servo off | Yes |
0x2519 | Vibration Suppression Filter 2 Damping | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 5 | 0 | - | RW | No | Servo off | Yes |
9. Object Dictionary
9-56
Monitoring (from 0x2600)
0x2600 | Feedback Speed | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
INT | - | - | rpm | RO | Yes | - | No |
This represents the current rotation speed of the motor.
0x2601 | Command Speed | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
INT | - | - | rpm | RO | Yes | - | No |
This represents the speed command input to the speed control loop of the drive.
0x2602 | Following Error | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
DINT | - | - | pulse | RO | Yes | - | No |
This represents the positional error of position control.
0x2603 | Accumulated Operation Overload | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
INT | - | - | 0.1% | RO | No | - | No |
This represents the accumulated operation overload rate. When the value of the accumulated
operation overload rate reaches the overload warning level setting (0x2010), the operation overload
warning (W10) will occur; when it reaches 100%, the operation overload alarm (AL-21) will occur.
0x2604 | Instantaneous Maximum Operation Overload | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
INT | - | - | 0.1% | RO | Yes | - | No |
This represents the maximum value of the operation overload rate output instantaneously from the
drive. This value can be initialized by the initialization of the instantaneous maximum operation
overload.
9. Object Dictionary
9-57
0x2605 | DC-Link Voltage | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | - | - | Volt | RO | Yes | - | No |
This represents the DC link voltage by the main power input.
0x2606 | Accumulated Regeneration Overload | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
INT | - | - | 0.1% | RO | No | - | No |
This represents the accumulated overload rate of the regenerative resistor due to regenerative
operation. In case that the value of the accumulated regenerative overload rate reaches 100%, a
regenerative overload alarm (AL-23) will be generated.
0x2607 | SingleTurn Data | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UDINT | - | - | pulse | RO | Yes | - | No |
This represents the single-turn data of the motor. Values ranging from 0 to (encoder resolution-1) are
displayed.
0x2608 | Mechanical Angle | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | - | - | 0.1deg | RO | Yes | - | No |
This represents the single-turn data of the motor, ranging from 0.0 to 359.9.
0x2609 | Electrical Angle | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
INT | - | - | 0.1deg | RO | Yes | - | No |
This represents the electrical angle of the motor, ranging from -180.0 to 180.0.
9. Object Dictionary
9-58
0x260A | MultiTurn Data | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
DINT | - | - | rev. | RO | Yes | - | No |
This represents the multi-turn data of multi-turn encoder.
0x260B | Drive Temperature 1 | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
INT | - | - | oC | RO | No | - | No |
It is the temperature measured by the temperature sensor integrated onto the drive power board. If the
measurement is higher than 95℃, the drive overheat alarm 1 (AL-22) will be generated.
0x260C | Drive Temperature 2 | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
INT | - | - | oC | RO | No | - | No |
This represents the temperature measured by the temperature sensor integrated onto the drive control
board. If the measured temperature is higher than 90℃, the drive overheat alarm 2 (AL-25) will be
generated.
0x260D | Encoder Temperature | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
INT | - | - | oC | RO | No | - | No |
This represents the temperature measured by the temperature sensor integrated into serial encoder
provided by LSIS (if the setting values of the encoder type (0x2001) are 3, 4, 5, and 6). If the measured
temperature is higher than 90℃, the encoder overheat alarm (AL-26) will be generated.
0x260E | Motor Rated Speed | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | - | - | rpm | RO | No | - | No |
This represents the rated speed of the driving motor.
9. Object Dictionary
9-59
0x260F | Motor Maximum Speed | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | - | - | rpm | RO | No | - | No |
This represents the maximum speed of the driving motor.
0x2610 | Drive Rated Current | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | - | - | 0.1A | RO | No | - | No |
This represents the rated current of the drive.
0x2611 | FPGA Version | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
STRING | - | - | - | RO | No | - | No |
This represents the version of the FPGA within the drive.
0x2612 | Hall Signal Display | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | - | - | - | RO | No | - | No |
This represents the signal of the hall sensor installed in the encoder (or motor). This can be used to
verify the connection status of the hall sensor signal or compare the U-/V-/W-phases of the motor with
the direction of the hall sensor signal.
The signal value is repeated in the order of 546231 for a forward movement, while it is
repeated in the order of 132645 for a reverse movement.
Bit | Setting details |
0 | W-phase hall sensor signal |
1 | V-phase hall sensor signal |
2 | U-phase hall sensor signal |
0x2613 | Bootloader Version | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
STRING | - | - | - | RO | No | - | No |
9. Object Dictionary
9-60
This represents the bootloader version of the drive.
0x2614 | Warning Code | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | - | - | - | RO | Yes | - | No |
This represents a warning code which has occurred in the drive.
0x2615 | Analog Input Channel 1 Value | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
INT | - | - | mV | RO | No | - | No |
This indicates the voltage in mV, which is inputted to the analogue input channel 1.
9. Object Dictionary
9-61
Procedure and Alarm history(0x2700~ )
0x2700 | Procedure Command Code | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 0xFFFF | 0 | - | RW | No | - | No |
You can run various procedures with the following procedure command codes and command
arguments. Make sure to enter correct value of command argument prior to entering command code
because the drive refers to the command argument at the moment of entering the command code.
Command code | Command argument |
Run procedure |
Manual Jog (0x0001) |
1 | Servo on |
2 | Servo off | |
3 | Positive (+) driving (0x2300) | |
4 | Negative (-) driving (0x2300) | |
5 | Stop to zero speed | |
Programmed Jog (0x0002) |
1 | Servo on |
2 | Servo off | |
3 | Operation start | |
4 | Stop to zero speed (server on maintained) | |
Servo Alarm History Initialization(0x0003) |
1 | |
Off-line Auto Tuning (0x0004) |
1 | Start auto tuning |
Index Pulse Search (0x0005) |
1 | Servo on |
2 | Servo off | |
3 | Positive (+) search (0x230C) | |
4 | Negative (-) search (0x230C) | |
5 | Stop to zero speed | |
Absolute encoder reset (0x0006) |
1 | Absolute encoder reset |
Instantaneous Maximum Operation Overload Reset (0x0007) |
1 | Resets instantaneous maximum operation overload (0x2604) value |
Phase current offset tuning (0x0008) |
1 | Phase current offset tuning (The U-/V-/W-phase offsets are stored in 0x2015 - 7, respectively. If the offset is abnormally large, AL-15 will be generated.) |
Software reset (0x0009) |
1 | Software reset |
Commutation (0x000A) |
1 | Commutation is performed |
0x2701 | Procedure Command Argument | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to FFFFhex | 0 | - | RW | No | - | No |
9. Object Dictionary
9-62
0x2702 | Servo Alarm History | ALL | |||||
SubIndex 0 | Number of entries | ||||||
Variable type |
Setting range | Initial value |
Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
STRING | - | 16 | - | RO | No | - | No |
SubIndex 1 | Alarm code 1 (Newest) | ||||||
Variable type |
Setting range | Initial value |
Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
STRING | - | - | - | RO | No | - | No |
SubIndex 2 | Alarm code 2 | ||||||
Variable type |
Setting range | Initial value |
Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
STRING | - | - | - | RO | No | - | No |
SubIndex 3 | Alarm code 3 | ||||||
Variable type |
Setting range | Initial value |
Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
STRING | - | - | - | RO | No | - | No |
SubIndex 4 | Alarm code 4 | ||||||
Variable type |
Setting range | Initial value |
Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
STRING | - | - | - | RO | No | - | No |
SubIndex 5 | Alarm code 5 | ||||||
Variable type |
Setting range | Initial value |
Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
STRING | - | - | - | RO | No | - | No |
SubIndex 6 | Alarm code 6 | ||||||
Variable type |
Setting range | Initial value |
Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
STRING | - | - | - | RO | No | - | No |
SubIndex 7 | Alarm code 7 | ||||||
Variable type |
Setting range | Initial value |
Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
STRING | - | - | - | RO | No | - | No |
SubIndex 8 | Alarm code 8 | ||||||
Variable type |
Setting range | Initial value |
Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
STRING | - | - | - | RO | No | - | No |
9. Object Dictionary
9-63
SubIndex 9 | Alarm code 9 | ||||||
Variable type |
Setting range | Initial value |
Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
STRING | - | - | - | RO | No | - | No |
SubIndex 10 | Alarm code 10 | ||||||
Variable type |
Setting range | Initial value |
Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
STRING | - | - | - | RO | No | - | No |
SubIndex 11 | Alarm code 11 | ||||||
Variable type |
Setting range | Initial value |
Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
STRING | - | - | - | RO | No | - | No |
SubIndex 12 | Alarm code 12 | ||||||
Variable type |
Setting range | Initial value |
Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
STRING | - | - | - | RO | No | - | No |
SubIndex 13 | Alarm code 13 | ||||||
Variable type |
Setting range | Initial value |
Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
STRING | - | - | - | RO | No | - | No |
SubIndex 14 | Alarm code 14 | ||||||
Variable type |
Setting range | Initial value |
Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
STRING | - | - | - | RO | No | - | No |
SubIndex 15 | Alarm code 15 | ||||||
Variable type |
Setting range | Initial value |
Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
STRING | - | - | - | RO | No | - | No |
SubIndex 16 | Alarm code 16 (Oldest) | ||||||
Variable type |
Setting range | Initial value |
Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
STRING | - | - | - | RO | No | - | No |
This represents the history of servo alarm generated from the drive. Up to 16 servo alarms recently
generated are stored. The SubIndex 1 is the latest alarm while the SubIndex 16 is the oldest one out of
the recently generated alarms. The servo alarm history can be reset by procedure command.
9. Object Dictionary
9-64
Third Party Motor Support(0x2800~ )
The following motor parameters are provided to drive a motor manufactured by a third party in addition
to our motor. To drive a third party's motor through our drive, you have to enter correct parameters. In
this case, however, our company neither has performed any test for the combination of our drive and
the third party motor, nor gives any warranty for the motor characteristic.
0x2800 | [Third Party Motor] Type | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 1 | 0 | - | RW | No | Power recycling |
Yes |
This specifies the motor type.
Setting values | Setting details |
0 | Rotary motor |
1 | Linear motor |
0x2801 | [Third Party Motor] Number of Poles | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 2 to 1000 | 8 | - | RW | No | Power recycling |
Yes |
This specifies the number of motor poles. For linear motor, set it to 2.
0x2802 | [Third Party Motor] Rated Current | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
FP32 | - | 2.89 | Arms | RW | No | Power recycling |
Yes |
This specifies the rated current of the motor.
0x2803 | [Third Party Motor] Maximum Current | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
FP32 | - | 8.67 | Arms | RW | No | Power recycling |
Yes |
This specifies the maximum current of the motor.
9. Object Dictionary
9-65
0x2804 | [Third Party Motor] Rated Speed | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 1 to 60000 | 3000 | rpm | RW | No | Power recycling |
Yes |
This specifies the rated speed of the motor. For a linear motor, the unit is mm/s.
0x2805 | [Third Party Motor] Maximum Speed | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 1 to 60000 | 5000 | rpm | RW | No | Power recycling |
Yes |
This specifies the maximum speed of the motor. For a linear motor, the unit is mm/s.
0x2806 | [Third Party Motor] Inertia | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
FP32 | - | 0.321 | Kg.m2. 10-4 |
RW | No | Power recycling |
Yes |
This specifies the motor inertia. For a linear motor, set the weight of rotor. The unit is Kg.
0x2807 | [Third Party Motor] Torque Constant | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
FP32 | - | 0.46 | Nm/A | RW | No | Power recycling |
Yes |
This specifies the torque constant of a motor. For a linear motor, set the force constant. The unit is N/A.
0x2808 | [Third Party Motor] Phase Resistance | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
FP32 | - | 0.82 | ohm | RW | No | Power recycling |
Yes |
This specifies the phase resistance (= resistance between lines ÷ 2) of the motor.
9. Object Dictionary
9-66
0x2809 | [Third Party Motor] Phase Inductance | ALL | |||||
Variable type |
Setting range | Initial value |
Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
FP32 | 0 to 1000 | 3.66 | mH | RW | No | Power recycling |
Yes |
This specifies the phase inductance (= inductance between lines ÷ 2) of the motor.
0x280A | [Third Party Motor] TN Curve Data 1 | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 1 to 60000 | 3000 | rpm | RW | No | Power recycling |
Yes |
This specifies the data of the motor speed/torque curve. Enter the maximum speed at the time when
the maximum torque (for a linear motor, the maximum thrust) is output. For a linear motor, the unit is
mm/s.
0x280B | [Third Party Motor] TN Curve Data 2 | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
FP32 | - | 100.0 | % | RW | No | Power recycling |
Yes |
This specifies the data of the motor speed/torque curve. Enter the torque (thrust for a linear motor)
which can be output at the maximum speed in percentage (%) relative to the maximum torque.
9. Object Dictionary
9-67
0x280C | [Third Party Motor] Hall Offset | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 360 | 0 | deg | RW | No | Power recycling |
Yes |
The offset of the hall sensor attached for initial angle of a 3rd party motor may vary depending on
manufacturer. For this case, the hall sensor offset must be checked and correctly set.
9. Object Dictionary
9-68
9.3 CiA402 Objects
0x603F | Error Code | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | - | 0 | - | RO | Yes | - | No |
The alarm code which has last occurred in Servo Drive is displayed.
0x6040 | Controlword | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | 0 to 0xFFFF | 0 | - | RW | Yes | Always | No |
This is composed of bits which control the drive state, the operation mode, and manufacturer-specific
options.
Bit | Function | Description |
0 | Switch on | Refer to the section concerning Bits 0 to 3. |
1 | Enable Voltage | |
2 | Quick stop | |
3 | Enable operation | |
4 to 6 | Settings by operation mode |
Refer to the section concerning bits 4 to 9. |
7 | Fault reset | 01: Alarm/warning reset |
8 | Halt | Refer to the section concerning Bits 4 to 9. |
9 | Settings by operation mode |
|
10 | – | - |
11 to 15 | – | - |
<Description on Bits 0 to 3>
• Bits 0 to 3: Drive state control
Command | Controlword Bit | ||||
Bit 7 | Bit 3 | Bit 2 | Bit 1 | Bit 0 | |
Shutdown | 0 | – | 1 | 1 | 0 |
Switch on | 0 | 0 | 1 | 1 | 1 |
Switch on + Enable operation | 0 | 1 | 1 | 1 | 1 |
Disable voltage | 0 | – | – | 0 | – |
Quick stop | 0 | – | 0 | 1 | – |
Disable operation | 0 | 0 | 1 | 1 | 1 |
9. Object Dictionary
9-69
Enable operation | 0 | 1 | 1 | 1 | 1 |
<Description on Bits 4 to 9>
• Bits 4, 5 and 9: For PP mode operation
Bit 9 | Bit 5 | Bit 4 | Details |
0 | 0 | 0 → 1 | It proceeds to the next position when the operation at the current position is complete. |
– | 1 | 0 → 1 | It drives to the next position immediately. |
1 | 0 | 0 → 1 | It drives from the current position to the profile position at the profile speed before it applies the next position. |
• Bits 6 and 8: For PP mode operation
Bit | Function | Value | Details |
6 | Abs/rel | 0 | This sets the target position to an absolute value. |
1 | This sets the target position to a relative value. | ||
8 | Halt | 0 | Runs an operation or continues an operation. |
1 | Halts the operation according to the Halt Option code (0x605D). |
• Bits 4, 5, 6, 8 and 9: For HM mode operation
Bit | Function | Value | Details |
4 | Homing Start | 0 | Does not perform the homing operation. |
1 | Performs or is performing the homing operation. | ||
5 | – | 0 | - |
6 | – | 0 | - |
8 | Halt | 0 | Runs the bit 4 command. |
1 | Halts the operation according to the Halt Option code (0x605D). | ||
9 | – | 0 | Reserved |
• Bits 4, 5, 6, 8 and 9: For CSP, CSV, or CST mode operation
Bit | Function | Value | Details |
4 | – | 0 | - |
5 | – | 0 | - |
6 | – | 0 | - |
8 | Halt | 0 | Continues to perform the operation. |
1 | Halts the operation according to the Halt Option code (0x605D). | ||
9 | – | 0 | - |
9. Object Dictionary
9-70
• Bits 4, 5, 6, 8 and 9: For IP mode operation
Bit | Function | Value | Details |
4 | Use of Interpolation |
0 | Interpolation disabled |
1 | Interpolation enabled | ||
5 | – | 0 | - |
6 | – | 0 | - |
8 | Halt | 0 | Runs the bit 4 command. |
1 | Halts the operation according to the Halt Option code (0x605D). | ||
9 | – | 0 | Reserved |
• Bits 4, 5, 6, 8 and 9: For PV and PT mode operation
Bit | Function | Value | Details |
4 | – | 0 | Reserved |
5 | – | 0 | Reserved |
6 | – | 0 | Reserved |
8 | Halt | 0 | Continues to perform the operation. |
1 | Halts the operation according to the Halt Option code (0x605D). | ||
9 | – | 0 | Reserved |
0x6041 | Statusword | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UINT | - | - | - | RO | Yes | - | No |
The Statusword indicates the current state of the drive. It consists of bits that indicate the state
according to the drive and operation mode.
Bit | Function | Description |
0 | Ready to switch on | Refer to the section concerning Bits 0 to 7. |
1 | Switched on | |
2 | Operation enabled | |
3 | Fault | |
4 | Voltage enabled | |
5 | Quick stop | |
6 | Switch on disabled | |
7 | Warning | |
8 | – | Reserved |
9 | Remote | Processed as a Controlword (0x6040) |
9. Object Dictionary
9-71
10 | Operation mode specific |
Refer to the sections concerning bits 10, 12 and 13. |
11 | Internal limit active | Refer to the section concerning bit 11. |
12 to 13 | Operation mode specific |
Refer to the sections concerning bits 10, 12 and 13. |
14 | Torque limit active | 0: no torque limit active 1: torque limit active |
15 | – | Reserved |
<Description on Bits 0 to 7>
• Bits 0 to 7:: For the current state of the drive
Bit 7 | Bit 6 | Bit 5 | Bit 4 | Bit 3 | Bit 2 | Bit 1 | Bit 0 | Drive State |
– | 0 | – | – | 0 | 0 | 0 | 0 | Not ready to switch on |
– | 1 | – | – | 0 | 0 | 0 | 0 | Switch on disabled |
– | 0 | 1 | – | 0 | 0 | 0 | 1 | Ready to switch on |
– | 0 | 1 | – | 0 | 0 | 1 | 1 | Switched on |
– | 0 | 1 | – | 0 | 1 | 1 | 1 | Operation enabled |
– | 0 | 0 | – | 0 | 1 | 1 | 1 | Quick stop active |
– | 0 | – | – | 1 | 1 | 1 | 1 | Fault reaction active |
– | 0 | – | – | 1 | 0 | 0 | 0 | Fault |
– | – | – | 1 | – | – | – | – | Main Power On |
1 | – | – | – | – | – | – | – | Warning is occurred |
<Description on Bit 11>
• Bit 11: Indicates whether to use an internal limit
Use of an internal limit: Both the software position limit and internal limit are applied to the target position.
Use N-OT/P-OT contacts
Interpolation speed exceeded (used only in the IP or CSP mode)
<Description on Bits 10, 12 and 13>
• Bits 10, 12 and 13: For PP mode operation
Bit | State | Value | Details |
10 | Target reached | 0 | Halt (0x6040.8) = 0: Unable to reach the target position Halt (0x6040.8) = 1: deceleration |
1 | Halt (0x6040.8) = 0: Reached the target position Halt (0x6040.8) = 1: Speed is 0 |
||
12 | Set-point acknowledge |
0 | Prepares the previous set point and waits for a new set point |
1 | Changed from the previous set point to the new set point |
9. Object Dictionary
9-72
13 | Following error | 0 | No positional error |
1 | Positional error |
• Bits 10, 12 and 13: For homing mode operation
Bit 13 | Bit 12 | Bit 10 | Details |
Homing error |
Homing attained |
Target reached |
|
0 | 0 | 0 | Homing in progress |
0 | 0 | 1 | Homing stopped or not started |
0 | 1 | 0 | Performed homing operation, but the not reach the target |
0 | 1 | 1 | Homing completed |
1 | 0 | 0 | Homing error; speed not equal to 0 |
1 | 0 | 1 | Homing error; speed equal to 0 |
• Bits 10, 12 and 13: For CSP, CSV, or CST mode operation
Bit | State | Value | Details |
10 | Target reached | 0 | Unable to reach the target (position/velocity/torque) |
1 | Reached the target (position/velocity/torque) | ||
12 | Target value ignored |
0 | Ignores the target value (position/velocity/torque) |
1 | Uses the target value as the position control input | ||
13 | Following error | 0 | No positional error (always 0 in Csv/Torque Mode) |
1 | Positional error |
• Bits 10, 12 and 13: For IP mode operation
Bit | State | Value | Details |
10 | Target reached | 0 | Halt (0x6040.8) = 0: Unable to reach the target position Halt (0x6040.8) = 1: deceleration |
1 | Halt (0x6040.8) = 0: Reached the target position Halt (0x6040.8) = 1: Speed is 0 |
||
12 | IP mode active | 0 | Interpolation deactivated |
1 | Interpolation activated | ||
13 | – | 0 | - |
10 | Target reached | 0 | Halt (0x6040.8) = 0: Unable to reach the target position Halt (0x6040.8) = 1: deceleration |
9. Object Dictionary
9-73
• Bits 10, 12 and 13: For PV mode operation
Bit | State | Value | Details |
10 | Target reached | 0 | Halt (0x6040.8) = 0: Unable to reach the target position Halt (0x6040.8) = 1: deceleration |
1 | Halt (0x6040.8) = 0: Reached the target position Halt (0x6040.8) = 1: Speed is 0 |
||
12 | Speed | 0 | Not in a zero speed state |
1 | In zero a speed state | ||
13 | – | 0 | - |
• Bits 10, 12 and 13: For PT mode operation
Bit | State | Value | Details |
10 | Target reached | 0 | Halt (0x6040.8) = 0: Unable to reach the target position Halt (0x6040.8) = 1: deceleration |
1 | Halt (0x6040.8) = 0: Reached the target position Halt (0x6040.8) = 1: Speed is 0 |
||
12 | – | 0 | Reserved |
13 | – | 0 | Reserved |
0x605A | Quick Stop Option Code | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
INT | 0 to 4 | 2 | - | RW | No | Always | Yes |
This sets the Quick Stop option code.
Setting values | Description |
0 | Not used (transits into Switch On Disabled). |
1 | Slowly decelerates and then stops the drive according to the quick stop deceleration (0x6085) setting (Switch On Disabled). |
2 | Slowly decelerates and then stops the drive according to the quick stop deceleration (0x6085) setting (Switch On Disabled). |
3 | Stops using the torque limit value (Switch On Disabled). |
0x605B | Shutdown Option Code | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
INT | 0 to 1 | 0 | - | RW | No | Always | Yes |
This specifies the operation to shut down the servo drive (Operation Enabled state -> Ready to Switch
On state).
9. Object Dictionary
9-74
Setting values | Description |
0 | Not used |
1 | Decelerates to a stop; enters the Switch On Disabled state; enters the Ready state |
0x605C | Disable Operation Option Code | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
INT | 0 to 1 | 1 | - | RW | No | Always | Yes |
This specifies the Disable Operation state (Operation Enabled state Switched On state) option code.
Setting values | Description |
0 | Does not use the drive function |
1 | Decelerates to a stop; moves to the Switch On Disabled state; moves to the Not Ready state |
0x605D | Halt Option Code | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
INT | 0 to 4 | 0 | - | RW | No | Always | Yes |
The Halt option code sets the operation method used to move from the Operation Enabled state to the
Switched On state.
Setting values | Description |
1 | Decelerates to a stop; moves to the Operation Enabled state |
2 | Decelerates to a stop based on the quick stop deceleration time; move to the Operation Enabled state |
3 | Decelerates to a stop based on the torque limit; moves to the Operation Enabled state |
0x605E | Fault Reaction Option Code | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Storage |
INT | 0 | 0 | - | RW | No | Always | Yes |
This sets the operation method which protects the drive system during fault reactions.
Setting values | Description |
0 | Does not use the servo drive function. The motor will retain the free run state. |
9. Object Dictionary
9-75
0x6060 | Modes of Operation | ALL | |||||
Variable type |
Setting range |
Initial value |
Unit | Accessibility | assignment PDO | attribute Change | Storage |
SINT | 0 to 10 | 0 | - | RW | Yes | Always | No |
This sets the servo drive operation mode. The master sets the operation mode when the power is
turned on.
This drive provides the following operation modes:
Setting values | name | Details |
0 | - | Mode not assigned |
1 | PP | Profile Position mode |
2 | - | Reserved |
3 | PV | Profile Velocity mode |
4 | PT | Profile Torque mode |
6 | HM | Homing mode |
7 | - | Reserved |
8 | CSP | Cyclic Synchronous Position mode |
9 | CSV | Cyclic Synchronous Velocity mode |
10 | CST | Cyclic Synchronous Torque mode |
Other | - | Reserved |
0x6061 | Modes of Operation Display | ALL | |||||
Variable type |
Setting range |
Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
SINT | - | - | - | RO | Yes | - | No |
This displays the operation mode of the current drive.
0x6062 | Position Demand Value | ALL | |||||
Variable type |
Setting range |
Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Storage |
DINT | - | - | UU | RO | Yes | - | No |
This displays the position demand value in the position units (UU) specified by the user.
0x6063 | Position Actual Internal Value | ALL | |||||
Variable type |
Setting range |
Initial value |
Unit | Accessibility | assignment PDO | attribute Change | Storage |
9. Object Dictionary
9-76
DINT | - | - | pulse | RO | Yes | - | No |
This displays the actual internal position value in encoder pulses.
0x6064 | Position Actual Value | ALL | |||||
Variable type |
Setting range |
Initial value |
Unit | Accessibility | assignment PDO | attribute Change | Stora ge |
DINT | - | - | UU | RO | Yes | - | No |
This displays the actual position value in user-defined position units (UU).
0x6065 | Following Error Window | ALL | |||||
Variable type |
Setting range |
Initial value |
Unit | Accessibility | assignment PDO | attribute Change | Stora ge |
UDINT | 0 to 0x3FFFFFFF |
600000 | UU | RW | No | Always | Yes |
This specifies the positional error range to check the Positional Error (Statusword, 0x6041.13).
0x6066 | Following Error Timeout | ALL | |||||
Variable type |
Setting range |
Initial value |
Unit | Accessibility | assignment PDO | attribute Change | Stora ge |
UINT | 0 to 65535 | 0 | ms | RW | No | Always | Yes |
This specifies the timeout for when checking the Positional Error (Statusword, 0x6041.13).
0x6067 | Position Window | ALL | |||||
Variable type |
Setting range |
Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Stora ge |
UDINT | 0 to 0x3FFFFFFF |
100 | UU | RW | No | Always | Yes |
This specifies the position window for the target. If the drive remains within the position window
(0x6067) for the position window time (0x6068), then it sets bit 10 of the Statusword (0x6041.10) to 1.
0x6068 | Position Window Time | ALL | |||||
Variable type |
Setting range |
Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Stora ge |
UINT | 0 to 65535 | 0 | ms | RW | No | Always | Yes |
This sets the time it takes to reach the target position. If the drive remains within the position window
(0x6067) for the position window time (0x6068), then it sets bit 10 of the Statusword (0x6041.10) to 1.
9. Object Dictionary
9-77
0x606B | Velocity Demand Value | ALL | |||||
Variable type |
Setting range |
Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Stora ge |
DINT | - | - | UU/s | RO | Yes | - | No |
This displays the output speed of the position controller or the command speed input to the speed
controller.
0x606C | Velocity Actual Value | ALL | |||||
Variable type |
Setting range |
Initial value | Unit | Accessibility | PDO assignment |
Change attribute |
Stora ge |
DINT | - | - | UU/s | RO | Yes | - | No |
This displays the actual velocity value in user-defined position unit.
0x606D | Velocity Window | ALL | |||||
Variable type |
Setting range |
Initial value |
Unit | Accessibility | assignment PDO | attribute Change | Stora ge |
UINT | 0 to 65535 | 20000 | UU/s | RW | No | Always | Yes |
This specifies the velocity window. If the difference between the target speed and the actual speed
remains within the velocity window (0x606D) for the velocity window time (0x606E), then it sets bit 10
of the Statusword (0x6041.10) to 1.
0x606E | Velocity Window Time Velocity Window Time |
ALL | |||||
Variable type |
Setting range |
Initial value |
Unit | Accessibility | assignment PDO | attribute Change | Stora ge |
UINT | 0 to 65535 | 0 | ms | RW | No | Always | Yes |
This specifies the velocity window time. If the difference between the target speed and the actual speed
remains within the velocity window (0x606D) for the velocity window time (0x606E), then it sets bit 10
of the Statusword (0x6041.10) to 1.
0x6071 | Target Torque | ALL | |||||
Variable type |
Setting range |
Initial value |
Unit | Accessibility | assignment PDO | attribute Change | Stora ge |
INT | -5000 to 5000 |
0 | 0.1% | RW | Yes | Always | No |
This specifies the target torque for the motor in 0.1% increments of the rated torque during torque
control.
9. Object Dictionary
9-78
0x6072 | Maximum Torque | ALL | |||||
Variable type |
Setting range |
Initial value |
Unit | Accessibility | assignment PDO | attribute Change | Stora ge |
UINT | 0 to 5000 | 3000 | 0.1% | RW | Yes | Always | No |
This sets the maximum torque that the motor can output in 0.1% increments of the rated torque.
0x6074 | Torque Demand Value | ALL | |||||
Variable type |
Setting range |
Initial value |
Unit | Accessibility | assignment PDO | attribute Change | Stora ge |
INT | - | - | 0.1% | RO | Yes | - | No |
This displays the current torque demand value in 0.1% increments of the rated torque.
0x6077 | Torque Actual Value | ALL | |||||
Variable type |
Setting range |
Initial value |
Unit | Accessibility | assignment PDO | attribute Change | Stora ge |
INT | - | - | 0.1% | RO | Yes | - | No |
This displays the actual torque value generated by the drive in 0.1% increments of the rated torque.
0x607A | Target Position | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Stora ge |
DINT | –2147483648 to 2147483647 |
0 | UU | RW | Yes | Always | No |
This specifies the target position in Profile Position (PP) mode and Cyclic Synchronous Position (CSP)
mode.
It is used as absolute coordinate or relative coordinate depending on the Bit 4 (0x6040.4) setting of the
Controlword in the PP mode, and is always used as absolute value in the CSP mode.
0x607C | Home Offset | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Stora ge |
DINT | –536870912 to 536870911 |
0 | UU | RW | No | Always | Yes |
This sets the offset value for the origin of the absolute encoder or absolute external scale and the zero
position of the actual position value (0x6064).
• Incremental Encoder
If it finds the home position or it is at the home position, then the position moved by the home offset
value becomes the zero position.
9. Object Dictionary
9-79
• Absolute Encoder
If the absolute encoder is connected, then the home offset value is added to the absolute position (the
actual position value).
0x607D | Software Position Limit | ||||||
SubIndex 0 | Number of entries | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibil ity | assignment PDO | attribute Change | Storage |
USINT | - | 2 | - | RO | No | - | No |
SubIndex 1 | Min. position limit | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibil ity | assignment PDO | attribute Change | Storage |
DINT | -1073741824 to 1073741823 |
-2000000000 | UU | RW | No | Always | Yes |
SubIndex 2 | Max. position limit | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibil ity | assignment PDO | attribute Change | Storage |
DINT | -1073741824 to 1073741823 |
2000000000 | UU | RW | No | Always | Yes |
This specifies the software position limit value. It limits the range of the position demand value (0x6062)
and actual position value (0x6064) and checks the new target positions for the setting value at every
cycle.
The minimum software limit value is the reverse rotation limit. The maximum software limit value is the
forward rotation limit.
0x607F | Max Profile Velocity | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Stora ge |
UDINT | 0 to 0x7FFFFFFF |
0x7FFFF FFF |
UU/s | RW | Yes | Always | Yes |
This specifies the maximum profile speed for the PP mode operation.
0x6081 | Profile Velocity | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Stora ge |
UDINT | 0 to 0x7FFFFFFF |
200000 | UU/s | RW | Yes | Always | Yes |
This specifies the profile speed for the PP mode operation.
9. Object Dictionary
9-80
0x6083 | Profile Acceleration | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibilit y | assignment PDO | attribute Change | Stora ge |
UDINT | 0 to 0x7FFFFFFF |
200000 | UU/s2 | RW | No | Always | Yes |
This specifies the profile acceleration for the PP mode operation.
0x6084 | Profile Deceleration | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibilit y | assignment PDO | attribute Change | Stora ge |
UDINT | 0 to 0x7FFFFFFF |
200000 | UU/s2 | RW | No | Always | Yes |
This specifies the profile deceleration for the PP mode operation.
0x6085 | Quick Stop Deceleration | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibilit y | assignment PDO | attribute Change | Stora ge |
UDINT | 0 to 0x7FFFFFFF |
2000 | UU/s2 | RW | No | Always | Yes |
The system uses quick stop deceleration if the quick stop option code (0x605A) is set to 2.
0x6087 | Torque Slope | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibilit y | assignment PDO | attribute Change | Stora ge |
UDINT | 0 to 0x7FFFFFFF |
1000 | 0.1%/s | RW | Yes | Always | Yes |
This specifies the torque slope for the PT mode operation.
0x6091 | Gear Ratio | ||||||
SubIndex 0 | Number of entries | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibil ity | assignment PDO | attribute Change | Storage |
USINT | - | 2 | - | RO | No | - | No |
SubIndex 1 | Motor revolutions | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibil ity | assignment PDO | attribute Change | Storage |
DINT | 0 to 0x40000000 | 1 | - | RW | No | Power | Yes |
9. Object Dictionary
9-81
recycling | |||||||
SubIndex 2 | Shaft revolutions | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibil ity | assignment PDO | attribute Change | Storage |
DINT | 0 to 0x40000000 | 1 | - | RW | No | Power recycling |
Yes |
For more information, refer to Section 5.3 Electric Gear Setup.
0x6098 | Homing Method | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Stora ge |
SINT | -128 to 127 | 34 | - | RW | No | Always | Yes |
This sets the homing method. For more information, refer to 4.6 Homing.
Setting values | Details |
0 | Disabled |
1 | Homing using the index pulse and reverse limit contact |
2 | Homing using the index pulse and forward limit contact |
7 to 14 | Homing using the index pulse and home contact |
24 | Same as method 8 (does not use the index pulse) |
28 | Same as method 12 (does not use the index pulse) |
33, 34 | Homing to the index pulse |
35 | Homing to the current position |
-1 | Homing using the negative stopper and index pulse |
-2 | Homing using the positive stopper and index pulse |
-3 | Homing using the negative stopper only |
-4 | Homing using the positive stopper only |
9. Object Dictionary
9-82
0x6099 | Homing Speeds | ||||||
SubIndex 0 | Number of entries(Number of entries) | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibil ity | assignment PDO | attribute Change | Storage |
USINT | - | 2 | - | RO | No | - | No |
SubIndex 1 | Switch search speed(Speed during search for switch) | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibil ity | assignment PDO | attribute Change | Storage |
DINT | 0 to 0x40000000 | 500000 | UU/s | RW | No | Always | Yes |
SubIndex 2 | Zero search speed(Speed during search for zero) | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibil ity | assignment PDO | attribute Change | Storage |
DINT | 0 to 0x40000000 | 100000 | UU/s | RW | No | Always | Yes |
This specifies the operation speed for homing.
0x609A | Homing Acceleration | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibilit y | assignment PDO | attribute Change | Stora ge |
UDINT | 0 to 0x40000000 | 200000 | UU/s2 | RW | No | Always | Yes |
This specifies the operation acceleration for homing.
0x60B0 | Position Offset | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibilit y | assignment PDO | attribute Change | Stora ge |
DINT | -2147483648 to 2147483647 |
0 | UU | RW | Yes | Always | No |
In the CSP mode, this specifies the offset value added to the position command.
0x60B1 | Velocity Offset | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibilit y | assignment PDO | attribute Change | Stora ge |
DINT | -2147483648 to 2147483647 |
0 | UU/s | RW | Yes | Always | No |
In the CSP mode, this corresponds to the speed feedforward value.
In the CSV mode, this specifies the offset value added to the speed command value.
9. Object Dictionary
9-83
0x60B2 | Torque Offset | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibilit y | assignment PDO | attribute Change | Stora ge |
INT | -5000 to 5000 | 0 | 0.1% | RW | Yes | Always | No |
In the CSP and CSV modes, this corresponds to the torque feedforward value.
In the CST mode, this specifies the offset value added to the torque command value.
0x60B8 | Touch Probe Function | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibilit y | assignment PDO | attribute Change | Stora ge |
UINT | 0 to 0xFFFF | 0x0033 | - | RW | Yes | Always | Yes |
This sets the touch probe function.
Bit | Value | Description |
0 | 0 | Does not use the touch probe 1. |
1 | Uses the touch probe 1. | |
1 | 0 | Single trigger mode |
1 | Continuous trigger mode | |
2 | 0 | Triggered by the input of the touch probe 1. |
1 | Triggered by the Index pulse signal. | |
3 | – | Reserved |
4 | 0 | Does not capture the rising edge position value of the touch probe 1. |
1 | Captures the rising edge position value of the touch probe 1. | |
5 | 0 | Does not capture the falling edge position value of the touch probe 1. |
1 | Captures the falling edge position value of the touch probe 1. | |
6 to 7 | – | Reserved |
8 | 0 | Does not use the touch probe 2. |
1 | Uses the touch probe 2. | |
9 | 0 | Single trigger mode |
1 | Continuous trigger mode | |
10 | 0 | Triggered by the input of the touch probe 2. |
1 | Triggered by the Index pulse signal. | |
11 | – | Reserved |
12 | 0 | Does not capture the rising edge position value of the touch probe 2. |
1 | Captures the rising edge position value of the touch probe 2. | |
13 | 0 | Does not capture the falling edge position value of the touch probe 2. |
9. Object Dictionary
9-84
1 | Captures the falling edge position value of the touch probe 2. | |
14 to 15 | – | Reserved |
0x60B9 | Touch Probe Status | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Stora ge |
UINT | - | - | - | RO | Yes | - | No |
This displays the status of the touch probe.
Bit | Value | Description |
0 | 0 | Does not use the touch probe 1. |
1 | Uses the touch probe 1. | |
1 | 0 | Does not store the rising edge position value of the touch probe 1. |
1 | Stores the rising edge position value of the touch probe 1. | |
2 | 0 | Does not store the falling edge position value of the touch probe 1. |
1 | Stores the falling edge position value of the touch probe 1. | |
3 to 5 | – | Reserved |
6 | 0, 1 | Toggles when the rising edge position value of the touch probe 1 is updated. |
7 | 0, 1 | Toggles when the falling edge position value of the touch probe 1 is updated. |
8 | 0 | Does not use the touch probe 2. |
1 | Uses the touch probe 2. | |
9 | 0 | Does not store the rising edge position value of the touch probe 2. |
1 | Stores the rising edge position value of the touch probe 2. | |
10 | 0 | Does not store the falling edge position value of the touch probe 2. |
1 | Stores the falling edge position value of the touch probe 2. | |
11 to 13 | – | Reserved |
14 | 0, 1 | Toggles when the rising edge position value of the touch probe 2 is updated. |
15 | 0, 1 | Toggles when the falling edge position value of the touch probe 2 is updated. |
In continuous trigger mode, you can toggle whether to save all update values for 6, 7, 14 and 15 bits on
the rising/falling edge of the touch probe.
To disable bits 1, 2, 9 and 10 (saving the position values on the rising/falling edges of touch probes 1
and 2) of the touch probe state (0x60B9), disable bits 4, 5, 12 and 13 (using sampling on the
rising/falling edges of touch probes 1 and 2) of the touch probe function (0x60B8) and enable them.
9. Object Dictionary
9-85
0x60BA | Touch Probe 1 Positive Edge Position Value | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Stora ge |
DINT | - | - | UU | RO | Yes | - | No |
This represents the rising edge position value of the touch probe 1.
0x60BB | Touch Probe 1 Negative Edge Position Value | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Stora ge |
DINT | - | - | UU | RO | Yes | - | No |
This represents the falling edge position value of the touch probe 1.
0x60BC | Touch Probe 2 Positive Edge Position Value | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Stora ge |
DINT | - | - | UU | RO | Yes | - | No |
This represents the rising edge position value of the touch probe 2.
0x60BD | Touch Probe 2 Negative Edge Position Value | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Stora ge |
DINT | - | - | UU | RO | Yes | - | No |
This represents the falling edge position value of the touch probe 2.
0x60E0 | Positive Torque Limit Value | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Stora ge |
UINT | 0 to 5000 | 3000 | 0.1% | RW | Yes | Always | Yes |
This sets the limit of positive torque values.
0x60E1 | Negative Torque Limit Value | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Stora ge |
UINT | 0 to 5000 | 3000 | 0.1% | RW | Yes | Always | Yes |
This sets the limit of negative torque values.
9. Object Dictionary
9-86
0x60F4 | Following Error Actual Value | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Stora ge |
DINT | - | - | UU | RO | Yes | - | No |
This displays the actual position error during position control.
0x60FC | Position Demand Internal Value | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Stora ge |
DINT | - | - | pulse | RO | Yes | - | No |
This represents the value entered as the command during the position control.
0x60FD | Digital Inputs | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Stora ge |
UDINT | - | - | - | RO | Yes | - | No |
They indicate the status of digital inputs.
Bit | Description |
0 | NOT (negative limit switch) |
1 | POT (positive limit switch) |
2 | HOME (origin sensor input) |
3 to 15 | Reserved |
16 | DI #1(I/O pin 11), 0:Open, 1:Close |
17 | DI #2(I/O pin 12), 0:Open, 1:Close |
18 | DI #3(I/O pin 7), 0:Open, 1:Close |
19 | DI #4(I/O pin 8), 0:Open, 1:Close |
20 | DI #5(I/O pin 13), 0:Open, 1:Close |
21 | DI #6(I/O pin 14), 0:Open, 1:Close |
22 | DI #7(I/O pin 9), 0:Open, 1:Close |
23 | DI #8(I/O pin 10), 0:Open, 1:Close |
24~30 | Reserved |
31 | STO(Safe Torque Off), 0:Close, 1:Open |
9. Object Dictionary
9-87
0x60FE | Digital Outputs | ||||||
SubIndex 0 | Number of entries | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibil ity |
PDO assignment |
Change attribute |
Storage |
USINT | - | 2 | - | RO | No | - | No |
SubIndex 1 | Physical outputs | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibil ity |
PDO assignment |
Change attribute |
Storage |
UDINT | 0 to 0xFFFFFFFF | 0 | - | RW | Yes | Always | No |
SubIndex 2 | Bit mask | ||||||
Variable type |
Setting range | Initial value | Unit | Accessibil ity |
PDO assignment |
Change attribute |
Storage |
UDINT | 0 to 0xFFFFFFFF | 0 | - | RW | Yes | Always | Yes |
They indicate the status of digital outputs.
Description of physical outputs
Bit | Description |
0 to 15 | Reserved |
16 | Forced output (0: OFF, 1: ON) of DO #1 (I/O pins 3 and 4) Provided that the relevant bit mask (0x60FE:02.16) is set to 1. |
17 | Forced output (0: OFF, 1: ON) of DO #2 (I/O pins 23 and 24) Provided that the relevant bit mask (0x60FE:02.17) is set to 1. |
18 | Forced output (0: OFF, 1: ON) of DO #3 (I/O pins 25 and 26) Provided that the relevant bit mask (0x60FE:02.18) is set to 1. |
19 | Forced output (0: OFF, 1: ON) of DO #4 (I/O pins 1 and 2) Provided that the relevant bit mask (0x60FE:02.19) is set to 1. |
20 to 23 | Reserved |
24 | Output status of DO #1 (0: OFF, 1: ON) |
25 | Output status of DO #2 (0: OFF, 1: ON) |
26 | Output status of DO #3 (0: OFF, 1: ON) |
27 | Output status of DO #4 (0: OFF, 1: ON) |
28 to 31 | Reserved |
Description of bit mask
Bit | Description |
9. Object Dictionary
9-88
0 to 15 | Reserved |
16 | Forced output setting (0: Disable, 1: Enable) of DO #1 (I/O pins 3 and 4) |
17 | Forced output setting (0: Disable, 1: Enable) of DO #2 (I/O pins 23 and 24) |
18 | Forced output setting (0: Disable, 1: Enable) of DO #3 (I/O pins 25 and 26) |
19 | Forced output setting (0: Disable, 1: Enable) of DO #4 (I/O pins 1 and 2) |
20 to 31 | Reserved |
0x60FF | Target Velocity | ALL | |||||
Variable type |
Setting range | value Initial | Unit | Accessibility | assignment PDO | attribute Change | Stora ge |
DINT | –2147483648 to 2147483647 |
0 | UU/s | RW | Yes | Always | No |
This specifies the target velocity in the PV mode and the CSV mode.
0x6502 | Supported Drive Modes | ALL | |||||
Variable type |
Setting range | Initial value | Unit | Accessibility | assignment PDO | attribute Change | Storage |
UDINT | - | 0x000003AD | - | RO | No | - | No |
This displays the mode(s) supported by the drive.
Bit | Supported modes | Details |
0 | PP (Profile Position) | 1: Supported |
1 | Vl (Velocity) | 0: Not supported |
2 | PV (Profile Velocity) | 1: Supported |
3 | PT (Torque Profile) | 1: Supported |
4 | Reserved | 0 |
5 | HM (Homing) | 1: Supported |
6 | IP (Interpolated Position) | 0: Not Supported |
7 | CSP (Cyclic Synchronous Position) | 1: Supported |
8 | CSV (Cyclic Synchronous Velocity) | 1: Supported |
9 | CST (Cyclic Synchronous Torque) | 1: Supported |
10 to 31 | Reserved | 0 |
10. Product Specifications
10-1
10. Product Specifications
10.1 Servo Motor
10.1.1 Product Characteristcs
Servo Motor Type (APM-) | SEP09A | SEP15A | SEP22A | SEP30A | SEP06D | SEP11D | |
Applicable Drive (L7B) | L7□B010□ | L7□B020□ | L7□B035□ | L7□B010□ | |||
Rated Output | [kW] | 0.9 | 1.5 | 2.2 | 3.0 | 0.6 | 1.1 |
Rated torque | [Nm] | 2.86 | 4.77 | 7.0 | 9.55 | 2.86 | 5.25 |
[kgfcm] | 29.23 | 48.72 | 71.46 | 97.44 | 29.23 | 53.59 | |
Maximum instantaneous torque |
[Nm] | 8.59 | 14.32 | 21.01 | 28.65 | 8.59 | 15.76 |
[kgfcm] | 87.7 | 146.16 | 214.37 | 292.33 | 87.7 | 160.78 | |
Rated Current | [A] | 2.97 | 4.89 | 7.17 | 9.78 | 3.57 | 3.27 |
Max. Current | [A] | 8.91 | 14.67 | 21.51 | 29.34 | 10.71 | 9.81 |
Rated rotation speed |
[r/min] | 3000 | 2000 | ||||
Maximum rotation speed |
[r/min] | 5000 | 3000 | ||||
Inertia moment | [kgm2x10-4] | 6.659 | 11.999 | 17.339 | 22.679 | 6.659 | 11.999 |
[gfcms2] | 6.795 | 12.244 | 17.693 | 23.142 | 6.795 | 12.244 | |
Permitted load inertia | Motor inertia x10 | ||||||
Rated power rate | [kW/s] | 12.32 | 19.00 | 28.28 | 40.21 | 12.32 | 22.99 |
Speed and position detector |
Standard | Quadrature Type Incremental 3000[P/R] | |||||
Option | Serial type 19[Bit] | ||||||
Specifications and features |
Protection method |
Fully enclosedself-cooling IP65 (excluding axis penetration) | |||||
Time rating | Continuous | ||||||
Ambient temperature |
0-40 °C | ||||||
Ambient humidity |
20-80% RH (no condensation) | ||||||
Atmosphere | No direct sunlight, corrosive gas, or combustible gas. | ||||||
Anti-vibration | Vibration acceleration of 49 m/s2 (5G) |
10. Product Specifications
10-2
Rotational speed-Torque Characteristics
Servo Motor Type (APM-) | SEP16D | SEP22D | SEP05G | SEP09G | SEP13G | SEP17G |
Applicable Drive (L7B) | L7□B020□ | L7□B010□ | L7□B020□ |
10. Product Specifications
10-3
Rated Output | [kW] | 1.6 | 2.2 | 0.45 | 0.85 | 1.3 | 1.7 |
Rated torque | [Nm] | 7.64 | 10.5 | 2.86 | 5.41 | 8.28 | 10.82 |
[kgfcm] | 77.95 | 107.19 | 29.23 | 55.22 | 84.45 | 110.43 | |
Maximum instantaneous torque |
[Nm] | 22.92 | 31.51 | 8.59 | 16.23 | 24.83 | 32.47 |
[kgfcm] | 233.86 | 321.56 | 87.70 | 165.65 | 253.35 | 331.30 | |
Rated Current | [A] | 4.79 | 6.54 | 3.57 | 3.37 | 5.19 | 6.74 |
Max. Current | [A] | 14.37 | 19.62 | 10.71 | 10.11 | 15.57 | 20.22 |
Rated rotation speed |
[r/min] | 2000 | 1500 | ||||
Maximum rotation speed |
[r/min] | 3000 | 3000 | ||||
Inertia moment | [kgm2x10-4] | 17.339 | 22.679 | 6.659 | 11.999 | 17.339 | 22.679 |
[gfcms2] | 17.693 | 23.142 | 6.795 | 12.244 | 17.693 | 23.142 | |
Permitted load inertia | Motor inertia x10 | ||||||
Rated power rate | [kW/s] | 48.64 | 91.96 | 12.32 | 24.4 | 57.08 | 97.61 |
Speed and position detector |
Standard | Quadrature Type Incremental 3000[P/R] | |||||
Option | Serial type 19[Bit] | ||||||
Specifications and features |
Protection method |
Fully enclosedself-cooling IP65 (excluding axis penetration) | |||||
Time rating | Continuous | ||||||
Ambient temperature |
0-40 °C | ||||||
Ambient humidity |
20-80% RH (no condensation) | ||||||
Atmosphere | No direct sunlight, corrosive gas, or combustible gas. | ||||||
Anti-vibration | Vibration acceleration of 49 m/s2 (5G) |
Rotational speed-Torque Characteristics
Servo Motor Type (APM-) | SEP03M | SEP06M | SEP09M | SEP12M | SFP30A | SFP50A |
Applicable Drive (L7B) | L7□B010□ | L7□B020□ | L7□B035□ | L7□B050□ |
10. Product Specifications
10-4
Rated Output | [kW] | 0.3 | 0.6 | 0.9 | 1.2 | 3.0 | 5.0 |
Rated torque | [Nm] | 2.86 | 5.73 | 8.59 | 11.46 | 9.55 | 15.92 |
[kgfcm] | 29.23 | 58.47 | 87.70 | 116.93 | 97.44 | 162.40 | |
Maximum instantaneous torque |
[Nm] | 8.59 | 17.19 | 25.78 | 34.38 | 28.65 | 39.79 |
[kgfcm] | 87.70 | 175.40 | 263.09 | 350.79 | 292.33 | 406.01 | |
Rated Current | [A] | 2.52 | 2.42 | 3.62 | 4.80 | 9.37 | 15.49 |
Max. Current | [A] | 7.56 | 7.26 | 10.86 | 14.40 | 28.11 | 38.73 |
Rated rotation speed |
[r/min] | 1000 | 3000 | ||||
Maximum rotation speed |
[r/min] | 2000 | 5000 | ||||
Inertia moment | [kgm2x10-4] | 6.659 | 11.999 | 17.339 | 22.679 | 30.740 | 52.130 |
[gfcms2] | 6.795 | 12.244 | 17.693 | 23.142 | 31.367 | 53.194 | |
Permitted load inertia | Motor inertia x10 | Motor inertia x5 | |||||
Rated power rate | [kW/s] | 12.32 | 27.36 | 42.60 | 57.90 | 29.66 | 48.59 |
Speed and position detector |
Standard | Quadrature Type Incremental 3000[P/R] | |||||
Option | Serial type 19[Bit] | ||||||
Specifications and features |
Protection method |
Fully enclosedself-cooling IP65 (excluding axis penetration) | |||||
Time rating | Continuous | ||||||
Ambient temperature |
0-40 °C | ||||||
Ambient humidity |
20-80% RH (no condensation) | ||||||
Atmosphere | No direct sunlight, corrosive gas, or combustible gas. | ||||||
Anti-vibration | Vibration acceleration of 49 m/s2 (5G) |
Rotational speed-Torque Characteristics
Servo Motor Type (APM-) | SFP22D | SFP35D | SFP55D | SFP75D | SFP20G | SFP30G |
10. Product Specifications
10-5
Applicable Drive (L7B) | L7□B020□ | L7□B035□ | L7□B050□ | L7□B075□ | L7□B020□ | L7□B050□ | |
Rated Output | [kW] | 2.2 | 3.5 | 5.5 | 7.5 | 1.8 | 2.9 |
Rated torque | [Nm] | 10.50 | 16.71 | 26.26 | 35.81 | 11.46 | 18.46 |
[kgfcm] | 107.19 | 170.52 | 267.96 | 365.41 | 116.93 | 188.39 | |
Maximum instantaneous torque |
[Nm] | 31.51 | 50.13 | 65.65 | 89.52 | 34.38 | 55.39 |
[kgfcm] | 321.56 | 511.57 | 669.91 | 913.52 | 350.79 | 565.16 | |
Rated Current | [A] | 6.56 | 10.07 | 15.82 | 21.36 | 7.15 | 11.12 |
Max. Current | [A] | 19.68 | 30.21 | 39.55 | 53.4 | 21.45 | 33.36 |
Rated rotation speed |
[r/min] | 2000 | 1500 | ||||
Maximum rotation speed |
[r/min] | 3000 | 3000 | ||||
Inertia moment | [kgm2x10-4] | 30.740 | 52.130 | 83.600 | 121.350 | 30.740 | 52.130 |
[gfcms2] | 31.367 | 53.194 | 85.306 | 123.827 | 31.367 | 53.194 | |
Permitted load inertia | Motor inertia x5 | ||||||
Rated power rate | [kW/s] | 35.89 | 53.57 | 82.49 | 105.67 | 42.72 | 65.38 |
Speed and position detector |
Standard | Quadrature Type Incremental 3000[P/R] | |||||
Option | Serial type 19[Bit] | ||||||
Specifications and features |
Protection method |
Fully enclosedself-cooling IP65 (excluding axis penetration) | |||||
Time rating | Continuous | ||||||
Ambient temperature |
0-40 °C | ||||||
Ambient humidity |
20-80% RH (no condensation) | ||||||
Atmosphere | No direct sunlight, corrosive gas, or combustible gas. | ||||||
Anti-vibration | Vibration acceleration of 49 m/s2 (5G) |
Rotational speed-Torque Characteristics
Servo Motor Type (APM-) | SFP44G | SFP60G | SFP75G | SFP12M | SFP20M | SFP30M |
10. Product Specifications
10-6
Applicable Drive (L7B) | L7□B050□ | L7□B075□ | L7□B150□ | L7□B020□ | L7□B050□ | ||
Rated Output | [kW] | 4.4 | 6.0 | 7.5 | 1.2 | 2.0 | 3.0 |
Rated torque | [Nm] | 28.01 | 38.20 | 47.75 | 11.46 | 19.10 | 28.65 |
[kgfcm] | 285.83 | 389.77 | 487.21 | 116.93 | 194.88 | 292.33 | |
Maximum instantaneous torque |
[Nm] | 70.03 | 95.49 | 119.37 | 34.38 | 57.30 | 71.62 |
[kgfcm] | 714.57 | 974.42 | 1,218.02 | 350.79 | 584.65 | 730.81 | |
Rated Current | [A] | 16.87 | 22.78 | 25.96 | 4.77 | 7.88 | 11.92 |
Max. Current | [A] | 42.18 | 56.95 | 64.90 | 14.31 | 23.64 | 29.80 |
Rated rotation speed |
[r/min] | 1500 | 1000 | ||||
Maximum rotation speed |
[r/min] | 3000 | 2500 | 2000 | |||
Inertia moment | [kgm2x10-4] | 83.600 | 121.350 | 143.820 | 30.740 | 52.130 | 83.600 |
[gfcms2] | 85.306 | 123.827 | 146.755 | 31.367 | 53.194 | 85.306 | |
Permitted load inertia | Motor inertia x5 | ||||||
Rated power rate | [kW/s] | 93.86 | 120.23 | 158.51 | 42.72 | 69.97 | 98.17 |
Speed and position detector |
Standard | Quadrature Type Incremental 3000[P/R] | |||||
Option | Serial type 19[Bit] | ||||||
Specifications and features |
Protection method |
Fully enclosedself-cooling IP65 (excluding axis penetration) | |||||
Time rating | Continuous | ||||||
Ambient temperature |
0-40 °C | ||||||
Ambient humidity |
20-80% RH (no condensation) | ||||||
Atmosphere | No direct sunlight, corrosive gas, or combustible gas. | ||||||
Anti-vibration | Vibration acceleration of 49 m/s2 (5G) |
Rotational speed-Torque Characteristics
Servo Motor Type (APM-) | SF44M | SGP22D | SGP35D | SGP55D | SGP75D | SGP110D |
10. Product Specifications
10-7
Applicable Drive (L7B) | L7□B050□ | L7□B020□ | L7□B035□ | L7□B050□ | L7□B075□ | L7□B150□ | |
Rated Output | [kW] | 4.4 | 2.2 | 3.5 | 5.5 | 7.5 | 11.0 |
Rated torque | [Nm] | 42.02 | 10.50 | 16.71 | 26.26 | 35.81 | 52.52 |
[kgfcm] | 428.74 | 107.19 | 170.52 | 267.96 | 365.41 | 535.93 | |
Maximum instantaneous torque |
[Nm] | 105.04 | 31.51 | 50.13 | 78.78 | 89.52 | 131.30 |
[kgfcm] | 1,071.86 | 321.56 | 511.57 | 803.89 | 913.52 | 1,339.82 | |
Rated Current | [A] | 17.15 | 6.27 | 10.03 | 15.66 | 18.42 | 27.41 |
Max. Current | [A] | 42.88 | 18.81 | 30.09 | 46.98 | 46.05 | 68.53 |
Rated rotation speed |
[r/min] | 1,000 | 2000 | ||||
Maximum rotation speed |
[r/min] | 2,000 | 3000 | 2500 | |||
Inertia moment | [kgm2x10-4] | 121.350 | 51.42 | 80.35 | 132.41 | 172.91 | 291.36 |
[gfcms2] | 123.827 | 52.47 | 81.99 | 135.11 | 176.44 | 297.31 | |
Permitted load inertia | Motor inertia x5 | ||||||
Rated power rate | [kW/s] | 145.48 | 21.46 | 34.76 | 52.08 | 74.16 | 94.65 |
Speed and position detector |
Standard | Quadrature Type Incremental 3000[P/R] | |||||
Option | Serial type 19[Bit] | ||||||
Specifications and features |
Protection method |
Fully enclosedself-cooling IP65 (excluding axis penetration) | |||||
Time rating | Continuous | ||||||
Ambient temperature |
0-40 °C | ||||||
Ambient humidity |
20-80% RH (no condensation) | ||||||
Atmosphere | No direct sunlight, corrosive gas, or combustible gas. | ||||||
Anti-vibration | Vibration acceleration of 49 m/s2 (5G) |
Rotational speed-Torque Characteristics
Servo Motor Type (APM-) | SGP20G | SGP30G | SGP44G | SGP60G | SGP85G | SGP110G |
10. Product Specifications
10-8
Applicable Drive (L7B) | L7□B020□ | L7□B050□ | L7□B050□ | L7□B075□ | L7□B150□ | ||
Rated Output | [kW] | 1.8 | 2.9 | 4.4 | 6.0 | 8.5 | 11.0 |
Rated torque | [Nm] | 11.46 | 18.46 | 28.01 | 38.20 | 54.11 | 70.03 |
[kgfcm] | 116.93 | 188.39 | 285.83 | 389.77 | 552.17 | 714.57 | |
Maximum instantaneous torque |
[Nm] | 34.38 | 55.39 | 70.03 | 95.49 | 135.28 | 175.07 |
[kgfcm] | 350.79 | 565.16 | 714.57 | 974.42 | 1,380.43 | 1,786.43 | |
Rated Current | [A] | 6.83 | 11.08 | 16.71 | 19.65 | 28.24 | 28.02 |
Max. Current | [A] | 20.49 | 33.24 | 41.78 | 49.13 | 70.60 | 70.05 |
Rated rotation speed |
[r/min] | 1500 | |||||
Maximum rotation speed |
[r/min] | 3000 | 2500 | 2000 | |||
Inertia moment | [kgm2x10-4] | 51.42 | 80.35 | 132.41 | 172.91 | 291.36 | 291.36 |
[gfcms2] | 52.47 | 81.99 | 135.11 | 176.44 | 297.31 | 297.31 | |
Permitted load inertia | Motor inertia x5 | ||||||
Rated power rate | [kW/s] | 25.531 | 42.41 | 59.25 | 84.36 | 100.5 | 168.3 |
Speed and position detector |
Standard | Quadrature Type Incremental 3000[P/R] | |||||
Option | Serial type 19[Bit] | ||||||
Specifications and features |
Protection method |
Fully enclosedself-cooling IP65 (excluding axis penetration) | |||||
Time rating | Continuous | ||||||
Ambient temperature |
0-40 °C | ||||||
Ambient humidity |
20-80% RH (no condensation) | ||||||
Atmosphere | No direct sunlight, corrosive gas, or combustible gas. | ||||||
Anti-vibration | Vibration acceleration of 49 m/s2 (5G) |
Rotational speed-Torque Characteristics
Servo Motor Type (APM-) | SGP150G | SGP12M | SGP20M | SGP30M | SGP44M | SGP60M |
10. Product Specifications
10-9
Applicable Drive (L7B) | L7□B150□ | L7□B020□ | L7□B050□ | L7□B150□ | |||
Rated Output | [kW] | 15.0 | 1.2 | 2.0 | 3.0 | 4.4 | 6.0 |
Rated torque | [Nm] | 95.49 | 11.46 | 19.10 | 28.65 | 42.02 | 57.30 |
[kgfcm] | 974.42 | 116.93 | 194.88 | 292.33 | 428.74 | 584.65 | |
Maximum instantaneous torque |
[Nm] | 238.73 | 34.38 | 57.30 | 85.94 | 105.04 | 143.24 |
[kgfcm] | 2,436.05 | 350.79 | 584.65 | 876.98 | 1,071.86 | 1,461.63 | |
Rated Current | [A] | 35.70 | 4.72 | 7.84 | 11.73 | 17.29 | 22.93 |
Max. Current | [A] | 89.25 | 11.80 | 23.52 | 35.19 | 43.23 | 57.33 |
Rated rotation speed |
[r/min] | 1,500 | 1000 | ||||
Maximum rotation speed |
[r/min] | 2,000 | 2000 | ||||
Inertia moment | [kgm2x10-4] | 424.5 | 51.42 | 80.35 | 132.41 | 172.91 | 291.36 |
[gfcms2] | 433.2 | 52.47 | 81.99 | 135.11 | 176.44 | 297.31 | |
Permitted load inertia | Motor inertia x5 | ||||||
Rated power rate | [kW/s] | 214.8 | 25.53 | 45.39 | 61.97 | 102.08 | 112.64 |
Speed and position detector |
Standard | Quadrature Type Incremental 3000[P/R] | |||||
Option | Serial type 19[Bit] | ||||||
Specifications and features |
Protection method |
Fully enclosedself-cooling IP65 (excluding axis penetration) | |||||
Time rating | Continuous | ||||||
Ambient temperature |
0-40 °C | ||||||
Ambient humidity |
20-80% RH (no condensation) | ||||||
Atmosphere | No direct sunlight, corrosive gas, or combustible gas. | ||||||
Anti-vibration | Vibration acceleration of 49 m/s2 (5G) |
Rotational speed-Torque Characteristics
Servo Motor Type (APM-) | FEP09A | FEP15A | FEP22A | FEP30A | FEP06D | FEP11D |
10. Product Specifications
10-10
Applicable Drive (L7B) | L7□B010□ | L7□B020□ | L7□B035□ | L7□B010□ | |||
Rated Output | [kW] | 0.9 | 1.5 | 2.2 | 3.0 | 0.6 | 1.1 |
Rated torque | [Nm] | 2.86 | 4.77 | 7.00 | 9.55 | 2.86 | 5.25 |
[kgfcm] | 29.23 | 48.72 | 71.46 | 97.44 | 29.23 | 53.59 | |
Maximum instantaneous torque |
[Nm] | 8.59 | 14.32 | 21.01 | 28.65 | 8.59 | 15.76 |
[kgfcm] | 87.7 | 146.16 | 214.37 | 292.33 | 87.7 | 160.78 | |
Rated Current | [A] | 3.47 | 6.68 | 9.12 | 9.94 | 3.28 | 3.40 |
Max. Current | [A] | 10.40 | 20.03 | 27.35 | 29.81 | 9.83 | 10.19 |
Rated rotation speed |
[r/min] | 3000 | 2000 | ||||
Maximum rotation speed |
[r/min] | 5000 | 3000 | ||||
Inertia moment | [kgm2x10-4] | 6.659 | 11.999 | 17.339 | 22.679 | 6.659 | 11.999 |
[gfcms2] | 6.795 | 12.244 | 17.693 | 23.142 | 6.795 | 12.244 | |
Permitted load inertia | Motor inertia x 10 | ||||||
Rated power rate | [kW/s] | 12.32 | 19.00 | 28.28 | 40.21 | 12.32 | 22.99 |
Speed and position detector |
Standard | Serial type 19[Bit] | |||||
Specifications and features |
Protection method |
Fully enclosedself-cooling IP65 (excluding axis penetration) | |||||
Time rating | Continuous | ||||||
Ambient temperature |
0-40 °C | ||||||
Ambient humidity |
20-80% RH (no condensation) | ||||||
Atmosphere | No direct sunlight, corrosive gas, or combustible gas. | ||||||
Anti-vibration | Vibration acceleration of 49 m/s2 (5G) |
Rotational speed-Torque Characteristics
Servo Motor Type (APM-) | FEP16D | FEP22D | FEP05G | FEP09G | FEP13G | FEP17G |
10. Product Specifications
10-11
Applicable Drive (L7B) | L7□B020□ | L7□B010□ | L7□B020□ | ||||
Rated Output | [kW] | 1.6 | 2.2 | 0.45 | 0.85 | 1.3 | 1.7 |
Rated torque | [Nm] | 7.64 | 10.5 | 2.86 | 5.41 | 8.28 | 10.82 |
[kgfcm] | 77.95 | 107.19 | 29.23 | 55.22 | 84.45 | 110.43 | |
Maximum instantaneous torque |
[Nm] | 22.92 | 31.51 | 8.59 | 16.23 | 24.83 | 32.47 |
[kgfcm] | 233.86 | 321.56 | 87.70 | 165.65 | 253.35 | 331.30 | |
Rated Current | [A] | 4.97 | 6.80 | 3.28 | 3.50 | 5.39 | 7.01 |
Max. Current | [A] | 14.92 | 20.04 | 9.83 | 10.50 | 16.16 | 21.02 |
Rated rotation speed |
[r/min] | 2000 | 1500 | ||||
Maximum rotation speed |
[r/min] | 3000 | 3000 | ||||
Inertia moment | [kgm2x10-4] | 14.619 | 19.040 | 5.659 | 10.179 | 14.619 | 19.040 |
[gfcms2] | 14.917 | 19.429 | 5.774 | 10.387 | 14.917 | 19.429 | |
Permitted load inertia | Motor inertia x 10 | ||||||
Rated power rate | [kW/s] | 39.92 | 57.95 | 14.50 | 28.77 | 46.85 | 61.52 |
Speed and position detector |
Standard | Serial type 19[Bit] | |||||
Specifications and features |
Protection method |
Fully enclosedself-cooling IP65 (excluding axis penetration) | |||||
Time rating | Continuous | ||||||
Ambient temperature |
0-40 °C | ||||||
Ambient humidity |
20-80% RH (no condensation) | ||||||
Atmosphere | No direct sunlight, corrosive gas, or combustible gas. | ||||||
Anti-vibration | Vibration acceleration of 49 m/s2 (5G) |
Rotational speed-Torque Characteristics
Servo Motor Type (APM-) | FEP03M | FEP06M | FEP09M | FEP12M | FFP30A | FFP50A |
Applicable Drive (L7B) | L7□B010□ | L7□B035□ | L7□B075□ |
10. Product Specifications
10-12
Rated Output | [kW] | 0.3 | 0.6 | 0.9 | 1.2 | 3.0 | 5.0 |
Rated torque | [Nm] | 2.86 | 5.73 | 8.59 | 11.46 | 9.55 | 15.92 |
[kgfcm] | 29.23 | 58.47 | 87.70 | 116.93 | 97.44 | 162.40 | |
Maximum instantaneous torque |
[Nm] | 8.59 | 17.19 | 25.78 | 34.38 | 28.65 | 39.79 |
[kgfcm] | 87.70 | 175.40 | 263.09 | 350.79 | 292.33 | 406.01 | |
Rated Current | [A] | 3.28 | 3.28 | 3.33 | 4.87 | 9.79 | 16.07 |
Max. Current | [A] | 9.83 | 9.83 | 9.99 | 14.60 | 29.38 | 48.22 |
Rated rotation speed |
[r/min] | 1000 | 3000 | ||||
Maximum rotation speed |
[r/min] | 2000 | 5000 | ||||
Inertia moment | [kgm2x10-4] | 5.659 | 10.179 | 14.619 | 19.040 | 27.960 | 46.560 |
[gfcms2] | 5.774 | 10.387 | 14.917 | 19.429 | 28.531 | 47.510 | |
Permitted load inertia | Motor inertia x 10 | Motor inertia x 5 | |||||
Rated power rate | [kW/s] | 14.50 | 32.25 | 50.53 | 68.97 | 32.61 | 54.40 |
Speed and position detector |
Standard | Serial type 19[Bit] | |||||
Specifications and features |
Protection method |
Fully enclosedself-cooling IP65 (excluding axis penetration) | |||||
Time rating | Continuous | ||||||
Ambient temperature |
0-40 °C | ||||||
Ambient humidity |
20-80% RH (no condensation) | ||||||
Atmosphere | No direct sunlight, corrosive gas, or combustible gas. | ||||||
Anti-vibration | Vibration acceleration of 49 m/s2 (5G) |
Rotational speed-Torque Characteristics
Servo Motor Type (APM-) | FFP22D | FFP35D | FFP55D | FFP75D | FFP20G | FFP30G |
10. Product Specifications
10-13
Applicable Drive (L7B) | L7□B020□ | L7□B035□ | L7□B050□ | L7□B075□ | L7□B020□ | L7□B035□ | |
Rated Output | [kW] | 2.2 | 3.5 | 5.5 | 7.5 | 1.8 | 2.9 |
Rated torque | [Nm] | 10.50 | 16.71 | 26.26 | 35.81 | 11.46 | 18.46 |
[kgfcm] | 107.19 | 170.52 | 267.96 | 365.41 | 116.93 | 188.39 | |
Maximum instantaneous torque |
[Nm] | 31.51 | 50.13 | 78.78 | 89.52 | 34.38 | 55.39 |
[kgfcm] | 321.56 | 511.57 | 803.89 | 913.52 | 350.79 | 565.16 | |
Rated Current | [A] | 6.93 | 9.09 | 14.70 | 18.97 | 7.56 | 10.04 |
Max. Current | [A] | 20.80 | 27.26 | 44.10 | 47.42 | 22.69 | 30.12 |
Rated rotation speed |
[r/min] | 2000 | 1500 | ||||
Maximum rotation speed |
[r/min] | 3000 | 2500 | 3000 | 2700 | ||
Inertia moment | [kgm2x10-4] | 27.960 | 46.560 | 73.850 | 106.730 | 27.960 | 46.560 |
[gfcms2] | 28.531 | 47.510 | 75.357 | 108.908 | 28.531 | 47.510 | |
Permitted load inertia | Motor inertia x 5 | ||||||
Rated power rate | [kW/s] | 39.46 | 59.98 | 93.38 | 120.15 | 46.96 | 73.21 |
Speed and position detector |
Standard | Serial type 19[Bit] | |||||
Specifications and features |
Protection method |
Fully enclosedself-cooling IP65 (excluding axis penetration) | |||||
Time rating | Continuous | ||||||
Ambient temperature |
0-40 °C | ||||||
Ambient humidity |
20-80% RH (no condensation) | ||||||
Atmosphere | No direct sunlight, corrosive gas, or combustible gas. | ||||||
Anti-vibration | Vibration acceleration of 49 m/s2 (5G) |
Rotational speed-Torque Characteristics
Servo Motor Type (APM-) | FFP44G | FFP60G | FFP75G | FFP12M | FFP20M | FFP30M |
10. Product Specifications
10-14
Applicable Drive (L7B) | L7□B050□ | L7□B075□ | L7□B020□ | L7□B050□ | |||
Rated Output | [kW] | 4.4 | 6.0 | 7.5 | 1.2 | 2.0 | 3.0 |
Rated torque | [Nm] | 28.01 | 38.20 | 47.75 | 11.46 | 19.10 | 28.65 |
[kgfcm] | 285.83 | 389.77 | 487.21 | 116.93 | 194.88 | 292.33 | |
Maximum instantaneous torque |
[Nm] | 84.034 | 95.49 | 119.37 | 34.38 | 57.30 | 71.62 |
[kgfcm] | 857.48 | 974.42 | 1,218.02 | 350.79 | 584.65 | 730.81 | |
Rated Current | [A] | 15.68 | 20.23 | 20.01 | 4.83 | 7.94 | 11.90 |
Max. Current | [A] | 47.04 | 50.58 | 50.03 | 14.50 | 23.83 | 35.70 |
Rated rotation speed |
[r/min] | 1500 | 1000 | ||||
Maximum rotation speed |
[r/min] | 3000 | 2500 | 2200 | 2000 | 1700 | |
Inertia moment | [kgm2x10-4] | 73.850 | 106.730 | 131.290 | 27.960 | 46.560 | 73.850 |
[gfcms2] | 85.306 | 108.908 | 133.969 | 28.531 | 47.510 | 75.357 | |
Permitted load inertia | Motor inertia x 5 | ||||||
Rated power rate | [kW/s] | 106.25 | 136.70 | 173.64 | 46.96 | 78.34 | 111.13 |
Speed and position detector |
Standard | Serial type 19[Bit] | |||||
Specifications and features |
Protection method |
Fully enclosedself-cooling IP65 (excluding axis penetration) | |||||
Time rating | Continuous | ||||||
Ambient temperature |
0-40 °C | ||||||
Ambient humidity |
20-80% RH (no condensation) | ||||||
Atmosphere | No direct sunlight, corrosive gas, or combustible gas. | ||||||
Anti-vibration | Vibration acceleration of 49 m/s2 (5G) |
Rotational speed-Torque Characteristics
Servo Motor Type (APM-) | FFP44M | FGP22D | FGP35D | FGP55D | FGP75D | FGP110D |
10. Product Specifications
10-15
Applicable Drive (L7B) | L7□B050□ | L7□B020□ | L7□B035□ | L7□B050□ | L7□B075□ | L7□B150□ | |
Rated Output | [kW] | 4.4 | 2.2 | 3.5 | 5.5 | 7.5 | 11.0 |
Rated torque | [Nm] | 42.02 | 10.50 | 16.71 | 26.26 | 35.81 | 16.71 |
[kgfcm] | 428.74 | 107.19 | 170.52 | 267.96 | 365.41 | 170.52 | |
Maximum instantaneous torque |
[Nm] | 117.65 | 31.51 | 50.13 | 78.78 | 89.52 | 50.13 |
[kgfcm] | 1200.47 | 321.56 | 511.57 | 803.89 | 913.52 | 511.57 | |
Rated Current | [A] | 16.69 | 7.12 | 8.73 | 16.04 | 19.10 | 27.41 |
Max. Current | [A] | 46.73 | 21.35 | 26.20 | 48.11 | 47.76 | 68.52 |
Rated rotation speed |
[r/min] | 1,000 | 2000 | ||||
Maximum rotation speed |
[r/min] | 2,000 | 3000 | 2700 | 3000 | 2500 | |
Inertia moment | [kgm2x10-4] | 106.730 | 41.130 | 71.530 | 117.720 | 149.400 | 291.36 |
[gfcms2] | 108.908 | 41.969 | 72.990 | 120.122 | 152.449 | 297.31 | |
Permitted load inertia | Motor inertia x 5 | ||||||
Rated power rate | [kW/s] | 145.48 | 26.83 | 39.04 | 58.58 | 85.83 | 94.68 |
Speed and position detector |
Standard | Serial type 19[Bit] | |||||
Specifications and features |
Protection method |
Fully enclosedself-cooling IP65 (excluding axis penetration) | |||||
Time rating | Continuous | ||||||
Ambient temperature |
0-40 °C | ||||||
Ambient humidity |
20-80% RH (no condensation) | ||||||
Atmosphere | No direct sunlight, corrosive gas, or combustible gas. | ||||||
Anti-vibration | Vibration acceleration of 49 m/s2 (5G) |
Rotational speed-Torque Characteristics
Servo Motor Type (APM-) | FGP20G | FGP30G | FGP44G | FGP60G | FGP85G | FGP110G |
10. Product Specifications
10-16
Applicable Drive (L7B) | L7□B020□ | L7□B035□ | L7□B050□ | L7□B075□ | L7□B150□ | ||
Rated Output | [kW] | 1.8 | 2.9 | 4.4 | 6.0 | 8.5 | 11.0 |
Rated torque | [Nm] | 11.46 | 18.46 | 28.01 | 38.20 | 54.11 | 70.03 |
[kgfcm] | 116.93 | 188.39 | 285.83 | 389.77 | 552.17 | 714.57 | |
Maximum instantaneous torque |
[Nm] | 34.38 | 55.39 | 84.03 | 95.49 | 135.28 | 175.07 |
[kgfcm] | 350.79 | 565.16 | 857.49 | 974.42 | 1,380.43 | 1,786.43 | |
Rated Current | [A] | 7.76 | 9.65 | 17.11 | 20.38 | 28.24 | 28.02 |
Max. Current | [A] | 23.29 | 28.95 | 46.19 | 50.95 | 70.60 | 70.05 |
Rated rotation speed |
[r/min] | 1500 | |||||
Maximum rotation speed |
[r/min] | 3000 | 2700 | 3000 | 2500 | 2500 | 2000 |
Inertia moment | [kgm2x10-4] | 41.130 | 71.530 | 117.720 | 149.400 | 291.36 | 291.36 |
[gfcms2] | 41.969 | 72.990 | 120.122 | 152.449 | 297.31 | 297.31 | |
Permitted load inertia | Motor inertia x 5 | ||||||
Rated power rate | [kW/s] | 25.531 | 42.41 | 59.25 | 84.36 | 100.5 | 168.3 |
Speed and position detector |
Standard | Serial type 19[Bit] | |||||
Specifications and features |
Protection method |
Fully enclosedself-cooling IP65 (excluding axis penetration) | |||||
Time rating | Continuous | ||||||
Ambient temperature |
0-40 °C | ||||||
Ambient humidity |
20-80% RH (no condensation) | ||||||
Atmosphere | No direct sunlight, corrosive gas, or combustible gas. | ||||||
Anti-vibration | Vibration acceleration of 49 m/s2 (5G) |
Rotational speed-Torque Characteristics
Servo Motor Type (APM-) | FGP150G | FGP12M | FGP20M | FGP30M | FGP44M | FGP60M |
Applicable Drive (L7B) | L7□B150□ | L7□B020□ | L7□B075□ | L7□B150□ |
10. Product Specifications
10-17
Rated Output | [kW] | 15.0 | 1.2 | 2.0 | 3.0 | 4.4 | 6.0 |
Rated torque | [Nm] | 95.49 | 11.46 | 19.10 | 28.65 | 42.02 | 57.30 |
[kgfcm] | 974.42 | 116.93 | 194.88 | 292.33 | 428.74 | 584.65 | |
Maximum instantaneous torque |
[Nm] | 238.73 | 34.38 | 57.30 | 85.94 | 113.45 | 143.24 |
[kgfcm] | 2,436.05 | 350.79 | 584.65 | 876.98 | 1157.59 | 1,461.63 | |
Rated Current | [A] | 35.70 | 4.75 | 7.88 | 11.74 | 17.39 | 22.93 |
Max. Current | [A] | 89.25 | 14.24 | 23.64 | 35.22 | 46.95 | 57.32 |
Rated rotation speed |
[r/min] | 1,500 | 1000 | ||||
Maximum rotation speed |
[r/min] | 2,000 | 2000 | ||||
Inertia moment | [kgm2x10-4] | 385.05 | 41.130 | 71.530 | 117.720 | 149.400 | 291.36 |
[gfcms2] | 392.90 | 41.969 | 72.990 | 120.122 | 152.449 | 297.31 | |
Permitted load inertia | Motor inertia x 5 | ||||||
Rated power rate | [kW/s] | 236.82 | 31.93 | 50.99 | 54.93 | 118.17 | 112.64 |
Speed and position detector |
Standard | Serial type 19[Bit] | |||||
Specifications and features |
Protection method |
Fully enclosedself-cooling IP65 (excluding axis penetration) | |||||
Time rating | Continuous | ||||||
Ambient temperature |
0-40 °C | ||||||
Ambient humidity |
20-80% RH (no condensation) | ||||||
Atmosphere | No direct sunlight, corrosive gas, or combustible gas. | ||||||
Anti-vibration | Vibration acceleration of 49 m/s2 (5G) |
Rotational speed-Torque Characteristics
10. Product Specifications
10-18
Electric Brake Specifications
Applicable Motor Series | SEP/FEP | SFP/FFP | SGP/FGP |
Purpose | Maintenance | Maintenance | Maintenance |
Input voltage (V) | DC 24V | DC 24V | DC 90V |
Static friction torque (N•m) | 10.4 | 40 | 74 |
Capacity (W) | 19.4 | 25 | 32 |
Coil resistance (Ω) | 29.6 | 23 | 327 |
Rated current (A) | 0.81 | 1.04 | 0.28 |
Braking mechanism | Spring brake | Spring brake | Spring brake |
Insulation class | Grade F | Grade F | Grade F |
Note 1) DO NOT apply DC24V power (for interface only) to electronic brake.
You MUST use power source only for electronic brake.
Note 2) Electronic brake installed in our servo motor applies same specifications for each series.
Note 3) Electric brakes are designed to maintain a stop. Never use them for absolute braking.
Note 4) The characteristics of the electric brakes were measured at 20°C.
Note 5) These brake specifications are subject to change. Check the voltage specifications on your specific
motor.
■ Heat Sink
Classification | Standard (mm) | Classification |
AP13 | 350x350x20 | |
AP18 | 550x550x30 | |
AP22 | 650x650x35 |
Note 1) The data on the product features is measured when those heat sinks were applied.
※ Exculding axis penetration in the IP grade
※ When you attach reducer to the motor, we don’t guarantee IP for reducer.
※ If you bend over specification designated in cable standard, it is difficult to guarantee IP marked
※ It can be satisfied Prtotection grade when you use private cable only.
10. Product Specifications
10-19
10.1.2 Outline Diagram
SEP Series | APM-SEP09A,SEP06D,SEP05G,SEP03M,
SEP15A,SEP11D,SEP09G,SEP06M,SEP22A,SEP16D,
SEP13G,SEP09M, SEP30A,SEP22D,SEP17G,SEP12M
10. Product Specifications
10-20
External Dimensions | Key Dimensions |
Weight (Kg) |
||||||
L | LM | LC | S | T | W | U | ||
SEP09A,SEP06D,SEP05G,SEP03M | 201.3(239.3) | 143.3(181.3) | 93.8(93.6) | 19 | 5 | 5 | 3 | 5.5(7.04) |
SEP15A,SEP11D,SEP09G,SEP06M | 225.3(263.3) | 167.3(205.3) | 117.8(117.6) | 19 | 5 | 5 | 3 | 7.54(9.08) |
SEP22A,SEP16D,SEP13G,SEP09M | 249.3(287.3) | 191.3(229.3) | 141.8(141.6) | 22 | 6 | 6 | 3.5 | 9.68(11.22) |
SEP30A,SEP22D,SEP17G,SEP12M | 273.3(311.3) | 215.3(253.3) | 165.8(165.6) | 22 | 6 | 6 | 3.5 | 11.78(13.32) |
Note 1) Use DC power (24 V) to operate the brake.
Note 2) The sizes in parentheses apply when attached to the brakes.
SFP Series | APM-SFP30A,SFP22D,SFP20G,SFP12M,
SFP50A,SFP35D,SFP30G,SFP20M, SFP55D,SFP44G,
SFP30M, SFP75D,SFP60G,SFP44M,SFP75G
Model | External Dimensions | Key Dimensions | Eye Bolt |
Weight (Kg) |
||||
L | LM | LC | LR | S | QW | T | W | U |
10. Product Specifications
10-21
SFP30A, SFP22D, SFP20G, SFP12M | 261.5(312.9) | 182.5(233.9) | 133(132.7) | 79 | 60 | 8 | 10 | 5 | X | 12.4(19.2) |
SFP50A, SFP35D, SFP30G, SFP20M | 295.5(346.9) | 216.5(267.9) | 167(166.7) | 17.7(24.9) | ||||||
SFP55D, SFP44G SFP30M | 345.5(396.9) | 266.5(317.9) | 217(216.7) | O | 26.3(33.4) | |||||
SFP75D, SFP60G, SFP44M | 405.5(456.9) | 326.5(377.9) | 277(276.7) | 35.6(42.8) | ||||||
SFP75G(주 3) | 457.5 | 344.5 | 295 | 113 | 96 | 8 | 12 | 5 | 39.4 |
Note 1) LF30M or higher-end models have eye bolts.
Note 2) Use DC power (24 V) to operate the brake.
Note 3) The sizes in parentheses apply when attached to the brakes.
10. Product Specifications
10-22
SGP Series | APM-SGP22D,SGP20G,SGP12M,SGP35D,
SGP30G,SGP20M, SGP55D,SGP44G,SGP30M,SGP75D,
SGP60G,SGP44M,SGP110D,SG85G,SG60M
Model | External Dimensions | Power Connector |
Weight (Kg) |
||||
L | LM | LC | LF | LQ | S | ||
SGP22D, SGP20G, SGP12M | 236.5(302.7) | 171.5(237.7) | 122(121.2) | 19 | 56.4(122.6) | MS3102A 22-22P | 16.95(30.76) |
SGP35D,SGP30G, SGP20M | 256.5(322.7) | 191.5(257.7) | 142(142.2) | 21.95(35.7) | |||
SGP55D, SGP44G, SGP30M | 292.5(358.7) | 227.5(293.7) | 178(177.2) | 30.8(44.94) | |||
SGP75D, SGP60G, SGP44M, | 320.5(386.7) | 255.5(321.7) | 206(205.2) | 37.52(50.94) | |||
SGP110D, SGP85G, SG60M | 418.5(484.7) | 353.5(419.7) | 304(303.2) | 21 | 66(132.2) | MS3102A 32-17P | 66.2(82.6) |
Note 4) Use DC power (90 V) to operate the brake.
Note 5) The sizes in parentheses apply when attached to the brakes.
10. Product Specifications
10-23
■ SGP Series | APMSGP110G
10. Product Specifications
10-24
■ SGP Series | APM-SGP150G
10. Product Specifications
10-25
■FEP Series | APM-FEP09A, FEP06D, FEP05G, FEP03M
APM-FEP15A, FEP11D, FEP09G, FEP06M
APM-FEP22A, FEP16D, FEP13G, FEP09M
APM-FEP30A, FEP22D, FEP17G, FEP12M
Model | External Dimensions | Key Dimensions |
Weight (Kg) |
|||||
L | LM | LC | S | T | W | U | ||
FEP09A,FEP06D,FEP05G,FEP03M | 197.3(235.3) | 139.3(177.3) | 89.8(89.6) | 19 | 5 | 5 | 3 | 5.04(6.58) |
FEP15A,FEP11D,FEP09G,FEP06M | 217.3(255.3) | 159.3(197.3) | 109.8(109.6) | 19 | 5 | 5 | 3 | 6.74(8.28) |
FEP22A,FEP16D,FEP13G,FEP09M | 237.3(275.3) | 179.3(217.3) | 129.8(129.6) | 22 | 6 | 6 | 3.5 | 8.48(10.02) |
FEP30A,FEP22D,FEP17G,FEP12M | 255.3(293.3) | 197.3(235.3) | 147.8(147.6) | 24 | 7 | 8 | 4 | 10.05(11.59) |
Note 1) Note 2) |
Use DC power (24 V) to operate the brake. The sizes in parentheses apply when attached to the brakes. |
10. Product Specifications
10-26
■ FFP Series | APM-FFP30A, FFP22D, FFP20G, FFP12M
APM-FFP50A, FFP35D, FFP30G, FFP20M
APM-FFP55D, FFP44G, FFP30M
APM-FPF75D, FPF60G, FFP44M
APM-FFP75G
Model | External Dimensions | Key Dimensions | Eye Bolt |
Weight (Kg) |
||||||
L | LM | LC | LR | S | QW | T | W | U | ||
FFP30A, FFP22D, FFP20G, FFP12M | 257.5(308.9) | 178.5(229.9) | 129(128.7) | 79 | 60 | 8 | 10 | 5 | X | 12.5(19.7) |
FFP50A, FFP35D, FFP30G, FFP20M | 287.5(338.9) | 208.5(259.9) | 159(158.7) | 17.4(24.6) | ||||||
FFP55D, FFP44G FFP30M | 331.5(382.9) | 252.5(303.9) | 203(202.7) | O | 25.2(32.4) | |||||
FFP75D, FFP60G, FFP44M | 384.5(435.9) | 305.5(356.9) | 256(255.7) | 12 | 33.8(41.0) | |||||
FFP75G(주 3) | 439.5 | 326.5 | 277 | 113 | 96 | 38.5 |
Note 3) Note 4) Note 5) |
Use DC power (24 V) to operate the brake. The sizes in parentheses apply when attached to the brakes. Using MS3102A 32-17P Connector for SFP75G |
10. Product Specifications
10-27
■ FGP Series | APM-FGP22D, FGP20G, FGP12M
APM-FGP35D, FGP30G, FGP20M
APM-FGP55D, FGP44G, FGP30M
APM-FGP75D, FGP60G, FGP44M
APM-FGP110D, FGP85G, FGP60M
Model | External Dimensions | Power Connector |
Weight (Kg) |
||||
L | LM | LC | LF | LQ | S | ||
FGP22D, FGP20G, FGP12M | 229.5(295.7) | 164.5(230.7) | 115(114.2) | 19 | 56.4(122.6) | MS3102A 22-22P | 15.42(29.23) |
FGP35D, FGP30G, FGP20M | 250.5(316.7) | 185.5(251.7) | 136(135.2) | 20.22(34.03) | |||
FGP55D, FGP44G, FGP30M | 282.5(348.7) | 217.5(283.7) | 168(167.2) | 28.02(41.83) | |||
FGP75D, FGP60G, FGP44M, | 304.5(370.7) | 239.5(305.7) | 190(189.2) | 33.45(47.26) | |||
FGP110D, FGP85G, FG60M | 418.5(484.7) | 353.5(419.7) | 304(303.2) | 21 | 66(132.2) | MS3102A 32-17P | 66.2(82.6) |
Note 6) Note 7) |
Use DC power (90 V) to operate the brake. The sizes in parentheses apply when attached to the brakes. |
10. Product Specifications
10-28
■ FGP Series | APM-FGP110G
10. Product Specifications
10-29
10.2 Servo Drive
10.2.1 Product Characteristics
Name Item |
XDL-L7NHB 010U |
XDL-L7NHB 020U |
XDL-L7NHB 035U |
XDL-L7NHB 050U |
XDL-L7NHB 075U |
XDL-L7NHB 150U |
Input Power | Main power | Three-phase AC 380-480 V (-15-10%), 50-60 Hz | ||||
Control power | Single-phase AC 380-480 V (-15-10%), 50-60 Hz | |||||
Rated current (A) | 3.7 | 8 | 10.1 | 17.5 | 22.8 | 39 |
Peak current (A) | 11.1 | 24 | 30.3 | 47.25 | 57 | 97.5 |
Encoder Type | Quadrature(Incremental) BiSS-B, BiSS-C(Absolute, Incremental) Tamagawa Serial(Absolute, Incremental) EnDat 2.2 |
|||||
Control performance |
Speed control range |
Maximum 1 : 5000 | ||||
Frequency response |
Maximum 1 kHz or above (when the 19-bit serial encoder is applied). | |||||
Speed regulation |
±0.01% or lower (when the load changes between 0 and 100%) ±0.1% or less (temperature of 25℃ (±10)) |
|||||
Torque control repeatability |
Within ±1% | |||||
EtherCAT Communication Specification |
Communication Specification |
FoE (Firmware download) EoE (Parameter setting, adjustment, auxiliary functions, and parameter copy through UDP) CoE (IEC 61158 Type12, IEC 61800-7 CiA 402 drive profile) |
||||
Physical layer | 100BASE-TX(IEEE802.3) | |||||
Connector | RJ45 x 2 | |||||
Distance | Within 100 m between nodes | |||||
DC (Distributed Clock) |
Sync by DC mode Minimum DC cycle: 250[us] | |||||
LED display | LinkAct IN, LinkAct OUT, RUN, ERR | |||||
Cia402 drive profile |
Profile Position Mode Profile Velocity Mode |
10. Product Specifications
10-30
Profile Torque Mode Cyclic Synchronous Position Mode Cyclic Synchronous Velocity Mode Cyclic Synchronous Torque Mode Homing Mode |
||
Digital Input/Output |
Digital Input | Input voltage range: DC 12[V] ~ DC 24[V] A total of 8 input channels (allocable) You can selectively allocate a total of 12 functions. (*POT, *NOT, *HOME, *STOP, *PCON, *GAIN2, *P_CL, *N_CL, PROBE1, PROBE2, EMG, A_RST) 주) * Default allocation signal. |
Digital Output | Rated voltage and current: DC 24 V ± 10%, 120 ㎃ A total of 4 input channels (allocable) You can selectively allocate a total of 11 kinds of output. (*BRAKE±, *ALARM±, *READY±, *ZSPD±, INPOS±, TLMT±, VLMT±, INSPD±, WARN±, TGON±, INPOS2±) 주) * Default allocation signal. |
|
Analog Monitor | A total of 2 input channels (allocable) You can selectively allocate a total of 15 kinds of output. |
|
Safety Functions | 2 input channels (STO1, STO2), 1 output channel (EDM±) | |
USB communication |
Function | Firmware download, parameter setting, adjustment, auxiliary functions, and parameter copy function. |
Communication standard |
Conform to the USB 2.0 Full Speed Standard. | |
Connecting device |
PC or USB storage medium | |
Built-in functions | Dynamic braking | Standard built-in (activated when the servo alarm goes off or when the servo is off) Note) If excessive DB(Dynamic Brake) or more than allowable inertia is used, the DB resistor may be burnt. |
Regenerative braking |
Both the default built-in brake and an externally installed brake are possible. Note) For L7□B150U, regenerative braking is installed externally as standard. |
|
Display function | Seven segments (5 DIGIT) | |
Self-Setting Function |
Possible to set the drive node address by using Rotary Switch | |
Add-on functions | Gain adjustment, alarm history, JOG operation, origin search | |
Protection | Overcurrent, overload, excessive current limit, overheat, overvoltage, |
10. Product Specifications
10-31
functions | undervoltage, overspeed, encoder error, position following error, current sensing error, etc. |
|
Use environment |
Use temperature /Storage temperature |
0 ~ 50[℃], -20 ~ 65[℃] |
Use humidity /Storage humidity |
90% RH or less (no condensation) | |
Other | Indoors in an area free from corrosive or combustible gases, liquids, or dust. |
10. Product Specifications
10-32
10.2.2 Outline Diagram
XDL-L7NHB010U
*Weight : 1.5 kg (including the cooling fan)
XDL-L7NHB020U / XDL-L7NHB035U
*Weight : 2.5 kg (including the cooling fan)
10. Product Specifications
10-33
XDL-L7NHB050U
*Weight : 5.5 kg (including the cooling fan)
XDL-L7NHB075U
*Weight : 8.5 kg (including the cooling fan)
10. Product Specifications
10-34
XDL-L7NHB150U
*Weight : 15.5 kg (including the cooling fan)
10. Product Specifications
10-35
10.3 Options and Peripheral Devices
■ Option (Incremental encoder cable)
Category | Product Name |
Name (Note 1) |
Applicable Motors |
Specifications |
For signaling |
S Series Motor INC. Encoder cable (Midium capacity) |
APCS E□□□BS |
APM-SEP APM-SFP APM-SGP SERIES All model |
1. Motor connection (MS:Military Standard) a. PLUG specifications : MS3108B 20-29S 2. Drive connection (CN2) a. Case specifications: 10314-52A0-008(3M) or SM-14J(Suntone 사) b. CONNECTOR specifications : 10114-3000VE(3M) or SM-14J(Suntone) 3. Cable specifications: 7Px0.2SQ or 7Px24AWG Motor connection Drive connection (ENCODER) |
Note 1) The in the name indicates the type and length of each cable. Refer to the following table for this information.
Cable length (m) | 3 | 5 | 10 | 20 |
Robot cable | F03 | F05 | F10 | F20 |
Regular cable | N03 | N05 | N10 | N20 |
■ Option (serial encoder cable)
Category | Product Name |
Name (Note 1) |
Applicable Motors |
Specifications |
For signaling |
S/Flat Series motor S-turn Encoder cable (medium capacity) |
APCS E□□□DS |
APM-SEP APM-SFP APM-SGP APM-FEP APM-FFP APM-FGP SERIES All models |
1. Motor connection a. PLUG specifications : MS3108A 20-29S 2. Drive connection (CN2) a. CASE specifications : 10314-52A0-008(3M) or SM-14J(Suntone) Motor connection Drive connection (ENCODER) |
10. Product Specifications
10-36
b. CONNECTOR specifications : 10114-3000VE(3M) or SM-14J(Suntone) 3. Cable specifications: 3Px0.2SQ or 3Px24AWG |
||||
For signaling |
S/Flat Series motor M-turn Encoder cable (medium capacity) |
APCS EDS1 |
APM-SEP APM-SFP APM-SGP APM-FEP APM-FFP APM-FGP SERIES All models |
1. Motor connection a. PLUGspecifications: MS3108A 20-29S 2. Drive connection (CN2) a. CASE specifications : 10314-52A0-008(3M) or SM-14J(Suntone) b. CONNECTOR specifications : 10114-3000VE(3M) or SM-14J(Suntone) 3. Cable specifications: 4Px0.2SQ or 4Px24AWG 4. Battery connection a. CONNECTOR specification : 5267-02A(Molex) b. Battery specification : ER6V(TOSHIBA, 3.6V, 2000mAh) Motor connection Drive connection |
Note 1) The in the name indicates the type and length of each cable. Refer to the following table for this information.
Cable length (m) | 3 | 5 | 10 | 20 |
Robot cable | F03 | F05 | F10 | F20 |
Regular cable | N03 | N05 | N10 | N20 |
■ Option [Medium capacity power cable]
Category | Product Name |
Name (Note 1) |
Applicable Motors |
Specifications |
10. Product Specifications
10-37
For power | Power cable (400V/Mediu m capacity 130Flange) |
APCF PHS |
APM-SEP APM-FEP SERIES All models |
1. Motor connection a. PLUG specifications : MS3108A 20-4S 2. Drive connection (U,V,W,FG) a. U,V,W pin specifications: 1512(Ferrule) b. FG pin specifications: 1.5x4(Ring Terminal) 3. Cable specifications: 4Cx1.5SQ or 4Cx15AWG <Motor side Connector> Motor connection Drive connection |
For power | Power cable (Brake type) (400V//Mediu m capacity 130Flange) |
APCF PNB |
APM-SEP APM-FEP SERIES All models |
1. Motor connection a. PLUGspecifications : MS3108A 20-15S 2. Drive connection a. U, V, W pin specifications: 1512(Ferrule) b. FG pin specifications: 1.5 x 4(Ring Terminal) 3. Power cable specifications : 4Cx1.5SQ or 4Cx15AWG 4. Brake power cable connection a. Connection terminal specifications: 1.5 x 3(Ring Terminal) 5. Brake cable specifications : 2Cx0.75SQ or 2Cx19AWG <Motor side Connector> Motor connection Drive connection |
Note 1) The in the name indicates the type and length of each cable. Refer to the following table for this information.
Cable length (m) | 3 | 5 | 10 | 20 |
Robot cable | F03 | F05 | F10 | F20 |
Regular cable | N03 | N05 | N10 | N20 |
Category | Product Name |
Name (Note 1) |
Applicable Motors |
Specifications |
10. Product Specifications
10-38
For power | Power cable (400V/Medium capacity below3.5kW 180Flange) |
APCF PIS |
SFP30A SFP22D SFP35D SFP20G SFP12M SFP20M SGP22D SGP35D SGP20G SGP12M SGP20M FFP30A FFP22D FFP35D FFP20G FFP30G FFP12M FFP20M FGP22D FGP35D FGP20G FGP30G FGP12M FGP20M |
1. Motor connection a. PLUG specification : MS3108A 22-22S 2. Drive connection (U,V,W,FG) a. U,V,W pin specification: 2512(Ferrule) b. FG pin specification : 2.5x4 (Ring Terminal) 3. Cable specifications: 4Cx1.5SQ or 4Cx15AWG <Motor side Connector> Motor connection Drive connection(CN2) |
For power | Power cable (For brake) (400V/Medium capacity below3.5kW 180Flange) |
APCF PPB |
SFP30A SFP22D SFP35D SFP20G SFP12M SFP20M FFP30A FFP22D FFP35D FFP20G FFP30G FFP12M FFP20M |
1. Motor connection a. PLUG specification : MS3108A 24-10S 2. Drive connection a. U, V, W pin specification: 2512(Ferrule) b. FG pin specification: 2.5 x 4(Ring Terminal) 3. Power Cable specifications:: 4Cx1.5SQ or 4Cx15AWG 4. Brake power connection a. Connection terminal specifications: 1.5 x 3(Ring Terminal) 5. Brake cable specifications : 2Cx0.75SQ or 2Cx19AWG <Motor side Connector> Motor connection Drive connection |
Note 1) The in the name indicates the type and length of each cable. Refer to the following table for this information.
Cable length (m) | 3 | 5 | 10 | 20 |
10. Product Specifications
10-39
Robot cable | F03 | F05 | F10 | F20 |
Regular cable | N03 | N05 | N10 | N20 |
Category | Product Name |
Name (Note 1) |
Applicable Motors |
Specifications |
For power | Power cable (400V/Mediu m capacity below7.5kW 180/220Flan ge) |
APCF PJS |
SFP50A, SFP55D, SFP75D, SFP30G SFP44G, SFP60G, SFP30M, SFP44M SGP55D, SGP75D, SGP30G, SGP44G, SGP60G, SGP30M, SGP44M FFP50A, FFP55D, FFP75D, FFP44G, FFP60G, FFP30M, FFP44M FGP55D, FGP75D, FGP44G, FGP60G, FGP30M, FGP44M |
1. Motor connection (MS : Military Standard) a. PLUG specification : MS3108A 22-22S 2. Drive connection (U,V,W,FG) a. U,V,W,FG 핀 specification : 4.0x 5(Ring Terminal) 3. Cable specification: 4Cx4.0SQ or 4Cx11AWG Drive connection (CN2) <Motor측 Connector> Motor connection |
For power | Power cable (400V/Mediu m capacity below7.5kW 180/Flange) |
APCF PLB |
SFP50A, SFP55D, SFP75D, SFP44G, SFP60G, SFP30M, SFP44M FFP50A, FFP55D, FFP75D, FFP44G, FFP60G, FFP75G FFP30M, FFP44M |
1. Motor connection a. PLUGspecification : MS3108A 24-10S 2. Drive connection a. U, V, W,FG pin specification : 4.0X5 (Ring Terminal) 3. Power cable specification : 4Cx4.0SQ or 4Cx11AWG 4. Brake power cable connection a. Connection terminal specifications: 1.5 x 3(Ring Terminal) 5. Brake cable specification : 2Cx0.75SQ or 2Cx19AWG Drive connection (CN2) Motor connection |
10. Product Specifications
10-40
Note 1) The in the name indicates the type and length of each cable. Refer to the following table for this information.
Cable length (m) | 3 | 5 | 10 | 20 |
Robot cable | F03 | F05 | F10 | F20 |
Category | Product Name |
Name (Note 1) |
Applicable Motors |
Specifications |
For power | Power cable (400V/Mediu m capacity below15kW 180/220 Flange) |
APCF PMS |
SFP75G, SGP110D, SGP85G, SGP110G, SGP150G, SGP60M FGP110D, FGP85G, FGP110G, FGP150G, FGP60M |
1. Motor connection a. PLUG specification : MS3108A 32-17S 2. Drive connection (U,V,W,FG) a. U,V,W,FG pin specification: 10x5 (Ring Termianl) 3. Cable specification: 4Cx10SQ or 4Cx7AWG Motor connection Drive connection(CN2) |
For power | Brake cable (200/400V 220 Flange) |
APCS PSB |
SGP22D SGP35D SGP55D SGP75D SGP12M SGP20M SGP30M SGP44M SGP20G SGP30G SGP44G SGP60G FGP22D FGP35D FGP55D FGP75D FGP20G FGP30G FGP30G FGP44G FGP60G FGP12M FGP20M FGP30M FGP44M |
1. Motor connection a. PLUG specifications : MS3108B 14-7S(MS) 2. For Brake power a. Connection terminal specifications : 1.5x3(Ring Terminal) 3. cable specification : 2Cx0.75SQ or 2Cx19AWG Motor connection Power connection |
Note 1) The in the name indicates the type and length of each cable. Refer to the following table for this information.
Cable length (m) | 3 | 5 | 10 | 20 |
Robot cable | F03 | F05 | F10 | F20 |
10. Product Specifications
10-41
■ Optional cables
Categ ory |
Product Name |
Name (Note 1) | Applicable Drive |
Specifications |
For signali ng |
I/O cable | APCS-CN1A | XDL-L7NH SERIES |
1. Drive connection (I/O) a. Case specifications: 10320-52A0-008 (3M) b. Connector specifications: 10120-3000VE (3M) c. Cable specifications: ROW-SB0.1Cx20C(AWG 28) [Upper level controller] [Drive connection] Pin number [Upper level controller] Pin number display |
For signali ng |
Communicatio n cable |
APCS-CM5L7U | XDL-L7NH SERIES | [PC - USB port] [Servo drive – USB] 1. PC connection: USB A Plug 2. Drive connection (USB): Mini USB 5P plug 3. Electrical requirements: Double shielded, twisted pair, EMI filter installation (similar product: SANWA 사 KU-AMB518) |
CN | I/O Connector | APC-CN2NNA | XDL-L7N SERIES | 1. Case specifications: 10320-52A0-008 (3M) 2. Connector specifications: 10120-3000VE (3M) 11 20 1 10 |
CN | STO Connector |
APCS-CN6J | XDL-L7N SERIES | 1. Case specifications: 2069577-1 (Tyco) |
CN | ECAT In/Out Connector |
APCS CN4NNA |
XDL-L7N SERIES | 1. Case specifications: 10320-52A0-008 (3M) PIN Signal Name Line color |
Note 1) The in the name indicates the length of each cable. Refer to the following table for this information.
Cable length (m) | 1 | 2 | 3 | 5 |
Written as | 01 | 02 | 03 | 05 |
■ Optional braking resistance
Categ ory |
Product Name |
Name | Applicable Drive |
Specifications |
10. Product Specifications
10-42
Resist ance |
Braking resistance |
IRV300-82Ω 82[Ω] (300W) |
L7□B010U |
Resist ance |
Braking resistance |
IRV600-140Ω 70Ω] (600W*2P) - Making under review |
L7□B020U /L7□B035U (2P) |
Resist ance |
Braking resistance |
IRV600-75Ω 25[Ω] (600W*3P) |
L7□B050U /L7□B075U (3P) |
Resist ance |
Braking resistance |
IRM2000- 13.4Ω 13.4[Ω] (2000W) |
L7□B150U |
11. Maintenance and Inspection
11-43
11. Maintenance and Inspection
11.1 Maintenance and Inspection
This chapter explains how to perform basic maintenance and inspection tasks as well as diagnose and
troubleshoot the servo motor and drive.
11.1.1 Precautions
1. Measuring the motor voltage: The PWM controls the voltage output from the servo amp to the motor.
Because of this, the waves take the form of pulses. Use a rectifier voltmeter for accurate
measurements because different meters may produce different results.
2. Measuring the motor current: Use a moving iron ammeter and wait for the motor's reactance to
smooth the pulse waveform into sine waves.
3. Measuring the electric power: Use an electrodynamometer based on the 3 power meter method.
4. Other gauges: When using an oscilloscope or digital voltmeter, do not allow them to touch the
ground. Use a 1 mA or less input current gauge.
11.1.2 What to Inspect
Wait at least 10 minutes after turning off the power before beginning the inspection because the
condenser can hold enough voltage to cause an electrical accident.
(1) Inspecting the Servo Motor
Caution |
Wait at least 10 minutes after turning off the power before beginning the inspection because the condenser can hold enough voltage to cause an electrical accident. |
Inspection Item |
Inspection Period | Inspection and Handling | Notes |
Vibration and sound check |
Monthly | Touch the motor and listen for sounds. | The feel and sounds should be the same as usual. |
Inspect the exterior of the motor |
Depends on the amount of contamination or damage. |
Clean the motor with a cloth or air pressure. |
- |
Measure the insulation resistance |
At least once a year | Disconnect the motor from the drive and measure the insulation resistance. A normal resistance level is 10 ㏁ or higher. Note 1) |
Contact our service center if the resistance is lower than 10 ㏁. |
Replace the oil seal |
At least once every 5,000 hours |
Remove the oil seal from the motor and replace it. |
This only applies to motors with an oil seal. |
General inspection |
At least once every 20,000 hours or after 5 years. |
Contact our service center. | Do not disassemble the servo motor yourself. |
Note 6) Measure the resistance between the FG and one of the U, V, and W power lines on the servo motor.
11. Maintenance and Inspection
11-44
(2) Inspecting the Servo Drive
Inspection Item |
Inspection Period |
Inspection process | What to do if you find an abnormality |
Clean the main body and control board |
At least once a year |
Check if there is any dust or oil | Clean it with air pressure or cloth. |
Check for loose screws |
At least once a year |
Check if terminal block or connector tightening screws, etc. are not loose. |
Tighten the screws. |
Check for defective parts on the main body or the control board |
At least once a year |
Check for discoloration, damage, or disconnection caused by heat. |
Contact our company. |
11.1.3 Replacing Parts
Mechanical friction and aging may deteriorate the following parts or even cause them to malfunction.
This makes it important to conduct regular maintenance checks and replace worn parts.
5. Smoothing condensers: Ripple currents and other factors can cause this part to wear. The
lifespan of this part depends on the operating temperature and environment. It normally lasts for 10
years if used continuously in a normal air-conditioned environment. Inspect the condenser at least
once each year because it can rapidly age over a short period of time once it starts to deteriorate
(inspect it more frequently as it approaches obsolescence).
※ Visual inspection criteria:
a. The condition of the case: Check for deformations on the sides and bottom.
b. The condition of the lid: Check for notable expansion, severe cracks, or broken parts.
c. The relief valve: Check for notable valve expansion and operation.
d. Also regularly check whether the exterior is cracked, discolored, or leaking and whether there
are any broken parts. The condenser is obsolete when its capacity degrades to less than 85% of
the rated capacity.
6. The relays: Check for bad connections and wear and tear on the contacts caused by switching
currents. A relay is obsolete when its accumulated number of switches reaches 100,000,
depending on the power capacity.
7. Motor bearings: Replace the bearings after 20,000 to 30,000 hours of operation at the rated speed
under the rated load. Replace the bearings if abnormal sounds or vibrations are detected during
inspection, depending on the operating conditions.
[The Standard Part Replacement Cycle]
Part Name | Standard Replacement Cycle |
Method |
Smoothing condenser | 7-8 years | Replace (determine after inspection). |
Relays | - | Determine after inspection |
Fuses | 10 years | Replace |
Aluminium electrolytic condensers on PCB |
5 years | Replace with new boards (determined after inspection) |
Cooling fans | 4-5 years | Replace |
Motor bearings | - | Determine after inspection |
Motor oil seal | 5,000 hours | Replace |
11. Maintenance and Inspection
11-45
11.2 Diagnosing and Troubleshooting Abnormalities
Alarm or warning will be generated if a problem occurs during operation. If this happens, check the
applicable code and take a proper action. If the problem persists, contact our service center.
11.2.1 Servo Motor
[Cause of abnormalities, inspection procedure, and troubleshooting methods]
Symptoms | Cause | Inspection process | Remedies |
The motor does not move. |
The P-OT and N-OT inputs are off. |
Refer to section 3.6, "Signals." | Turn on the P-OT and N-OT inputs. |
The motor has defects. | Use a resistance tester to measure the resistance to the motor lead terminal (resistance between phases: several ohms). |
Replace the motor. | |
The locking screws are loose. | Check the locking screws. | Tighten any loose screws. | |
The external wiring is incorrect or the cables are disconnected. |
Check the wires to the motor and the encoder. |
Redo the wiring. Replace the cables. |
|
The encoder has defects. | Check the output waves. | Replace the encoder. (Contact our service center.) |
|
Motor rotation is unstable. |
The connection is bad. | Check the connection of the motor lead terminal. |
Fix any bad connections. |
The input voltage is low. | Check the input voltage of the drive. | Change the power source. | |
Overloads occur. | Check the condition of the machine. | Remove any foreign substances from the rotating unit and grease or lubricate it. |
|
The motor overheats. |
The ambient temperature is too high. |
Check the temperature around the motor. 40[℃] or less |
Change heat transfer structure. Install a cooling fan. |
The surface of the motor is contaminated. |
Check whether there are any foreign substances on the surface of the motor. |
Clean the surface of the motor. | |
Overloads occur. | Check the load on the drive. Check the acceleration/deceleration time. |
Reduce the load. Increase the acceleration/deceleration time. Use a motor with a greater capacity. |
|
The magnetic power of the magnets is reduced. |
Check the counter voltage and voltage waveforms. |
Replace the motor. | |
The device is making a strange sound. |
Coupling is bad. | Tighten the coupling screws and measure the concentricity of the connection. |
Readjust the coupling. |
The bearings are abnormal. | Check the bearings for vibrations and sounds. |
Contact us. | |
The parameters are set incorrectly (the inertia, gain, and time constants). |
Check the parameters. | Refer to Chapter 9, "Object Dictionary." |
11. Maintenance and Inspection
11-46
11.2.2 Servo Drive
Servo Alarm
If the drive detects a problem, it will trigger a servo alarm and transition to the servo off state to stop. In this
case, the value of the emergency stop setting (0x2013) is used to stop the drive.
Alarm Code | Causes | Details | What to check |
IPM fault Over current Current limit exceeded |
Motor cable error |
Wiring is incorrect and check short | Replace motor cable |
Encoder cable error |
Wiring is incorrect and check short | Replace encoder cable | |
Parameter cable error |
Motor ID [0x2000], encoder type[0x2001], encoder form[0x2002] setting vaule should be same with applied to motor label. |
Modifty motor label and parameter concordantly |
|
Check motor phase resistor |
Check if U/V/W phase currentffset(0x2015~0x2017) is 5% or above of the rated current, Replace drive |
Replace motor | |
Machine part has problem |
Determine whether there is a conflict or binding in the equipment. |
Check machine part | |
Drive error | If alarm continue after servo on again, Replace drive. Because drive may have problem. |
||
Error by noize | Check method to improve noise of wiring, install. |
Please check condition of wiring for FG. Match wire size of FG with wire size of drive main circuit. |
|
IPM temperature | surroundings temperature |
Check wherther surrounding temperature is over 50 [℃] |
Lower surrounding temperature |
Continuous Overload alram |
Accumulated operate overload percentage [0x2603] Checking the load percentage is under 100% |
Change drive and motor capacitiy, Please tune gain. |
|
Motor cable open |
Check accumulated regenerative overload[0x2606] |
Adjust regenerarion resistor setting[0x2009] Use external regenerarion resistor. |
|
Drive setting direction |
Check drive setting status | Refer “2. Wiring and Joint | |
Drive error | If alarm continue after servo on again, Replace drive. Because drive may have problem. |
||
Current offset | Motor U/V/W phase current offset oversetting |
Check whether the U/V/W phase current offset [0x2015~0x2017] are 5% of the rated current or highter. |
Rerun adjusting phase current offset |
Drive error | If alarm occurs continually after adjusting offset of phase current, please replace new drive because drive has problem. |
||
Continuous overload | In case of sequent operating that exceed rated |
Check if load which is accumulating driving load rate[0x2603] is below 100% when it is in constant |
Change drive and motor capacitiy, Please tune gain. |
11. Maintenance and Inspection
11-47
Alarm Code | Causes | Details | What to check |
load | speed section and stop | ||
Motor brake error |
Checking whether the motor brake is not holding |
Provide power to motor brake | |
Parameter setting error |
Motor ID[0x2000], Encoder type[0x2001], Check the label of application motor and Encoder form[0x2002] setting value. |
Modify the parameter as same as motor label information. |
|
Over load detected standard load rate setting [0x200F] Value checking |
Set as proper value | ||
Machine part has problem |
there is no problem for running | Check machine part. | |
Motor cable error |
Wiring is incorrect and check short | Replace motor cable. | |
Encoder cable error |
Wiring is incorrect and check short | Replace encoer cable. | |
Drive temperature 1 | surrounding temerature |
Check wherther surrounding temperature is over 50 [℃] |
Lower surrounding temperature of drive. |
Drive error | Check if displayed value 1 [0x260B] of drive temperature is much different with surrounding temperature when it is normal condition. |
Replace the drive | |
Regeneration overload | Capacity excess by high frequency operationg or continue regenerative operating |
Checking overload rate accumulated regeneration on 0x2606 |
Adjust value on 0x2009. Use braking resistor |
Parameter setting error |
Check setting value[0x2009] ~ [0x200E] |
Set as proper value | |
Main power input voltage error |
Check whether Main power (544[Vac]) has problem or not. |
Recheck the power supply | |
Drive error | Checking the temperature of regenerative resistance on Servo-off status |
Replace the drive | |
Motor cable open | Parameter setting error |
Check [0x2015], [0x2015], [0x2015] Check value offset current |
Process the Phase current offset control procedure command |
Motor cable error |
Check whether cable is disconnected. | Replace the motor cable. | |
Motor error | Check short circuit of U,V,W in Motor (U-V, V-W, W-U) |
Replace the motor | |
Drive error | If specific alarm signal is persistently occurred, It is highly possible to have fault, so Kindly recommend you to change the servo drive. |
11. Maintenance and Inspection
11-48
Alarm Code | Causes | Details | What to check |
Drive temperature 2 | Surrounding temperature |
Check whether surrounding temperature is over 50[℃] |
Lower the surrondng termpertaure of drive |
Drive error | Comparing displayed drive temperature 2 [0x260C] in normal status and the surrounding temperature. |
Replace the drive | |
Encoder temperature | Reserved | ||
Encoder communication Encoder cable open Encoder data |
Encoder cable error |
Disconnect, wiring is incorrect and check Short. |
Replace encoder cable. |
Parameter setting error |
Value of [0x2001], [0x2002] is same with application motor label. |
Modify the parameter as same as motor label information. If modified value is not applied to parameter, it is highly possible to have fault, So Kindly recommend you to change the servo motor. |
|
Encoder error | If alarm continue after servo on again, Replace drive. Because drive may have problem. |
||
Drive error | If alarm continue after servo on again, Replace drive. Because drive may have problem. |
||
Motor setting | Setting Motor ID | Value of [0x2000] is same with application motor label. |
Revise it with motor label information equally. It is possible to release alarm when power off/on after adjusting parameter. |
Drive error | If alarm continue after servo on again, Replace drive. Because drive may have problem. |
||
Z Phase open | Encoder cable error |
Wiring is incorrect and check Short. | Replace encoder cable. |
Encoder error | If alarm continue after servo on again, Replace drive. Because drive may have problem. |
||
Drive error | If alarm continue after servo on again, Replace drive. Because drive may have problem. |
||
Low battery | Parameter setting error |
Check setting value [0x2005] | It will be no alarm to set as 1 when you use absolute encoder as the incremental encoder. |
Bad connection of battery No connected. |
Check status of battery access | Connect battery rightly. | |
When battery voltage is low |
Check whether voltage is over 3.3v. | Replace bettery | |
Sinusoidal ENC | Encoder cable error |
Wiring is incorrect and check short Check shield and FG disconnect |
Replace encoder cable. |
11. Maintenance and Inspection
11-49
Alarm Code | Causes | Details | What to check |
amplitude Sinusoidal ENC frequncy |
Parameter setting error |
Check setting valud of encoder type [0x2001] |
Check setting encoder type. Check speed command.(Maximum:250kHz) |
Drive error | If alarm continue after servo on again, Replace drive. Because drive may have problem. |
||
resolver error | If alarm continue after servo on again, Replace drive. Because drive may have problem. |
||
Encoder error | If alarm continue after servo on again, Replace drive. Because drive may have problem. |
||
Encoder setting error | Drive / Motor combination error |
Check brand label code of motor and drive. |
Use motor and drive of same brand label. |
Encoder cable error |
Wiring is incorrect and check Short | Replace encoder cable. | |
Encoder error | If alarm continue after servo on again, Replace drive. Because drive may have problem. |
||
Drive error | If alarm continue after servo on again, Replace drive. Because drive may have problem. |
||
Under voltage | Main power input voltage error |
Check the main power voltage is over 3phase 219[Vac] |
Recheck the power supply. |
Check [0x2605] value is over 310 [Vdc] when main power is accordingly input |
Replace the drive. | ||
running when power voltage is low |
Check wiring of main power supply | Use 3 phase as supply voltage. | |
Over voltage | Main power input voltage error |
Check whether the main power voltage is below 572[Vac] |
Recheck the power supply. |
Check [0x2605] value is below 810[Vdc] when main power is accordingly input. |
Replace the drive. | ||
When braking resistor is high |
Check operating condition regenerative resistance. |
Review the regenerative resistance consider the operating condition and load. |
|
Setting value of | In case of many time for acceleration / deceleration |
Set longer acceleration / deceleration time |
11. Maintenance and Inspection
11-50
Alarm Code | Causes | Details | What to check |
acceleration/ deceleration |
|||
Drive error | If alarm continue after servo on again, Replace drive. Because drive may have problem. |
||
Main power fail | Main power input voltage error |
check voltage between phase 380- 480[Vac] of L1, L2, L3. |
Recheck power supply. |
Parameter setting error |
Check setting value arroding to state of main power [0x2006] |
Wire or set parameter as input power on (possible 3 phase) |
|
momentary power failure |
Check setting value [0x2007] | check main power source or reduce value of [0x2007] | |
Drive error | If alarm continue after servo on again, Replace drive. Because drive may have problem. |
||
Control power fail | Voltage between phase of C1, C2 error |
Voltage between phase of C1, C2 is within 380-480[Vac]. |
Recheck power supply of drive |
Drive error | If alarm continue after servo on again, Replace drive. Because drive may have problem. |
||
Over speed limit | Motor Encoder error |
Wiring is incorrect and check Short. | Replace motor cable. |
Encoder cable error |
Wiring is incorrect and check Short. | Replace encoder cable. | |
Parameter setting error |
Value of [0x2000], [0x2001], [0x2002] is same with application motor label. |
Modify the parameter as sams as motor label information. |
|
Check setting value [0x6091] | Set Electronic gear ratio low. | ||
Check setting value[0x2100] ~ [0x211F] |
Readjust gain according to operating condtion. |
||
Encoder error | If alarm continue after servo on again, Replace drive. Because drive may have problem. |
||
Drive error | If alarm continue after servo on again, Replace drive. Because drive may have problem. |
||
POS following | Parameter setting error |
Check setting value [0x3000], [0x3003], [0x3004]. |
Set up correct parameter according to operating method. |
Check [0x6091] Setting value | Set Electronic gear ratio low. | ||
Check setting value on 0x6066 of position error excess time, 0x6065 of position error range |
Set up correct parameter according to operating method. |
||
Machine part has problem |
Checking it was forced by drive part | Check Machine part has problem | |
Drive error | If alarm continue after servo on again, Replace drive. Because drive may have problem. |
||
Excessive SPD deviation |
Motor cable error |
Disconnect, wiring is incorrect and check Short. |
Replace motor cable |
Encoder cable error |
Disconnect, wiring is incorrect and check Short. |
Replace encoder cable |
11. Maintenance and Inspection
11-51
Alarm Code | Causes | Details | What to check |
Parameter setting |
Value of [0x2000], [0x2001], [0x2002] is same with application motor label. |
Modify the parameter as sams as motor label information. |
|
Check setting value [0x6091] | Set Electronic gear ratio low.. | ||
Machine part has problem |
Checking it was forced by drive part operating condition of limit contact point sensor |
Check Machine part. | |
Encoder error | If alarm continue after servo on again, Replace drive. Because drive may have problem. |
||
Drive error | If alarm continue after servo on again, Replace drive. Because drive may have problem. |
||
Parameter checksum | When O/S is changed |
Check parameter that parameter setting value was set as maximum value of variable form |
Restore initial parameter (0x1011). If you restore it, setting up parameter would be changed into initial value. So set up parameter before operating |
Drive error | If alarm continue after servo on again, Replace drive. Because drive may have problem. |
||
Factory setting | Parameter setting error |
Contact our service center Check [0x1008] DeviceName |
Please download OS or set capacity of drive again. If alarm continue after servo on again, Replace drive. Because drive may have problem. |
11. Maintenance and Inspection
11-52
Servo Warning
If the drive detects an error classified as a servo warning, it will trigger a warning. In this case, the drive will
maintain normal operation condition. After the cause of the warning is eliminated, the warning will be
automatically cleared. In case of a warning, take an appropriate action. You can specify if each warning is
checked with warning mask configuration (0x2014).
Bit | Warning code |
Warning name |
0 | W01 | Main power phase loss |
1 | W02 | Low voltage of encoder battery |
2 | W04 | Software Position Limit |
3 | - | - |
4 | W10 | Operation overload |
5 | W20 | Abnormal combination of Drive and Motor, abnormal I/O setting |
6 | W40 | Low voltage |
7 | W80 | Emergency signal input |
Alarm Code | Causes | Detail | What to check |
PWR_FAIL | Main power input voltage error |
Check voltage between phase 380- 480[Vac] of L1, L2, L3 |
Recheck power supply. |
Parameter setting error |
Check value of main power input mode set[0x2006] arroding to state of main power input. |
Wire or set parameter as input power on(possible 3 phase) |
|
Momentary power failure |
Check value of main power input mode set[0x2006] arroding to state of main power input. |
Check actual main power or increase value of checking time of loss of main power. |
|
Drive error | If alarm continue after servo on again, Replace drive. Because drive may have problem. |
||
LOW_BATT | Parameter setting error |
Check setting value of absolute encoder [0x2005] |
Alarm will be disappeared if you set “1” when using ABS encoder as incremental encoder. |
Bad conection of battery, No connected. |
Check the status of battery | Connect battery rightly. | |
When battery voltage is low. |
Check whether battery voltage is over 3.3V |
Replace battery. | |
SW_POS_LMT | Parameter setting error |
Setting function of software restriction on location [0x2400], Check value of software restriction on location[0x607D] |
Change value of software position limit function[0x2400] or change the set of limit value of maximum postion and minimum position of software position limit[0x607D] |
OV_LOAD | In case of sequent |
Check overload warning level setting[0x2010] and constant speed section or accumulated operation |
Change drive and motor capacitiy, Please tune gain. |
11. Maintenance and Inspection
11-53
Alarm Code | Causes | Detail | What to check |
operating that exceed rated load |
overload rate[0x2603] | Adjust the setting value overload warning level[0x2010]. |
|
Motor brake error |
Checking the motor brake is not holding |
Provide supply power to motor brake. | |
Parameter setting error |
Motor ID[0x2000], Encoder type[0x2001], Encoder form [0x2002] vaule is same with motor label. |
Modify the parameter as sams as motor label information. |
|
Check value of set of overload detecting basic load rate[0x200F] |
Set as proper value. | ||
Machine part has problem |
There is no problem for running | Check machine part has problem | |
Motor cable error |
Wiring is incorrect and check Short. | Replace motor cable | |
Emcoder cable error |
Wiring is incorrect and check Short. | Replace encoder cable | |
SETUP | Drive / Motor Combination error |
Check whether capacity of current of motor is bigger than capacity of current of drive or not. |
reduce value of torque limit or use the motor which capacity is lower than capacity of current of drive |
IO setting error | Check whether one signal is assigned more than 2 in digital input signal assignment[0x2200] ~ [0x2208] and digital output signal assignment[0x2210]~[0x2213]. |
Set up correct parameter according to operating method. |
|
UD_VTG | Main power input voltage error |
Check if main power has problem or not |
Recheck the power supply. |
Check that DC link voltage [0X2605] is between 190~405 [Vdc] when main power is supplied correctly. |
Replace the drive | ||
Running when power voltage is low |
Check wiring status of main power | Use 3 phase as supply voltage | |
EMG | EMG contact error |
It is state of EMG Wiring or drive parameter(drivecontrol input1[0x211F], digital input signal1 set[0x2200]~digital input Check sinal 16 setting[0x220F] |
Set up correct parameter according to operating method. |
Drive error | If alarm continue after servo on again, Replace drive. Because drive may have problem. |
11. Maintenance and Inspection
11-54
11.3 Overload Operating Characteristic Curve
Overload Operating Characteristic Curve (1kW)
Overload(%) | AL-21 occurred time (sec) | Overload(%) | AL-21 occurred time (sec) | ||
Operation | Stop | Operation | Stop | ||
Below 100 | Infinite | Infinite | |||
110 | 55776.0 | 37937.7 | 210 | 100.0 | 50.1 |
120 | 13944.0 | 9483.9 | 220 | 60.0 | 38.5 |
130 | 6197.3 | 4215.1 | 230 | 40.0 | 30.3 |
140 | 3486.0 | 2371.0 | 240 | 30.3 | 9.7 |
150 | 1183.0 | 926.0 | 250 | 24.2 | 8.3 |
160 | 566.0 | 470.0 | 260 | 7.0 | 3.8 |
170 | 318.0 | 273.0 | 270 | 6.4 | 3.4 |
180 | 198.0 | 173.0 | 280 | 5.7 | 3.1 |
190 | 160.0 | 117.0 | 290 | 4.0 | 2.7 |
200 | 130.0 | 66.0 | 300 | 3.0 | 2.0 |
1
10
100
1000
10000
100000
t i m e( s e c)
11. Maintenance and Inspection
11-55
Overload Operating Characteristic Curve (2kW, 3.5kW)
Overload(%) | AL-21 occurred time (sec) | Overload(%) | AL-21 occurred time (sec) | ||
Operation | Stop | Operation | Stop | ||
Below 100 | Infinite | Infinite | |||
110 | 4602.0 | 4600.0 | 210 | 85.0 | 40.0 |
120 | 1208.0 | 1208.0 | 220 | 54.0 | 36.0 |
130 | 500.0 | 500.0 | 230 | 33.0 | 25.0 |
140 | 323.0 | 303.0 | 240 | 25.0 | 10.0 |
150 | 250.0 | 150.0 | 250 | 20.0 | 7.5 |
160 | 231.0 | 100.0 | 260 | 18.0 | 3.5 |
170 | 180.0 | 80.0 | 270 | 16.0 | 3.1 |
180 | 164.0 | 69.0 | 280 | 12.0 | 2.9 |
190 | 120.0 | 58.0 | 290 | 3.5 | 2.5 |
200 | 100.0 | 52.0 | 300 | 2.5 | 2.3 |
1
10
100
1000
10000
T i m e( S e c)
11. Maintenance and Inspection
11-56
Overload Operating Characteristic Curve (5kW, 7.5kW)
Overload(%) | AL-21 occurred time (sec) | Overload(%) | AL-21 occurred time (sec) | ||
Operation | Stop | Operation | Stop | ||
Below 100 | Infinite | Infinite | |||
110 | 5760.0 | 420.0 | 210 | 120.0 | 16.0 |
120 | 550.0 | 300.0 | 220 | 60.0 | 8.0 |
130 | 440.0 | 250.0 | 230 | 40.0 | 4.0 |
140 | 360.0 | 200.0 | 240 | 30.0 | 1.8 |
150 | 300.0 | 150.0 | 250 | 20.0 | 1.2 |
160 | 270.0 | 120.0 | 260 | 18.0 | 1.0 |
170 | 240.0 | 100.0 | 270 | 16.0 | 1.0 |
180 | 210.0 | 60.0 | 280 | 14.0 | 1.0 |
190 | 180.0 | 45.0 | 290 | 6.0 | 1.0 |
200 | 150.0 | 35.0 | 300 | 5.0 | 1.0 |
1.
11-57
Overload Operating Characteristic Curve (15kW)
Overload(%) | AL-21 occurred time (sec) | Overload(%) | AL-21 occurred time (sec) | ||
Operation | Stop | Operation | Stop | ||
Below 100 | Infinite | Infinite | |||
110 | 5760.0 | 704.0 | 210 | 49.0 | 16.4 |
120 | 1998.0 | 698.4 | 220 | 42.0 | 13.5 |
130 | 630.0 | 524.2 | 230 | 27.0 | 3.8 |
140 | 540.0 | 350.1 | 240 | 19.6 | 2.8 |
150 | 324.0 | 176.0 | 250 | 12.0 | 2.0 |
160 | 271.8 | 135.0 | 260 | 10.2 | 1.0 |
170 | 210.6 | 94.0 | 270 | 6.8 | 1.0 |
180 | 162.9 | 60.0 | 280 | 3.4 | 1.0 |
190 | 111.0 | 32.8 | 290 | 3.0 | 1.0 |
200 | 56.0 | 19.3 | 300 | 2.7 | 1.0 |
12. Test Drive
12-2
12. Test Drive
For safe and proper test drive, make sure to check the following prior to test drive. If there is a problem,
take an appropriate measure before the test drive.
Servo Motor State
Is the motor correctly installed and wired?
Is each connecting part correctly tightened without loosening?
For a motor with oil seal fitted, is there any damage on the oil seal?
Is oil properly applied?
If you perform test drive of a servo motor having been stored for an extended period, make sure to
check the motor according to the maintenance and inspection method for servo motor. For more
information on maintenance and inspection, refer to 11. Maintenance and Inspection.
Servo Drive State
Is the drive correctly installed, wired, and connected?
Is the supply voltage for the servo drive correct?
12. Test Drive
12-3
12.1 Preparation for Operation
Carry out test drive in the following order:
Verify that, before the test drive, the upper level controller and the servo drive are correctly wired, and
the objects of the servo drive are correctly configured.
Order | Handling | Notes |
1 | Connect the power connector and safety function connector of Servo Drive. | Refer to Section 2.5 Wiring for Input/Output Signals. |
2 | Connect motor and encoder cables to the servo drive. | Refer to Section 2.5 Wiring for Input/Output Signals. |
3 | If you use the safety function, connect the STO safety device connector. (Note) If you do not use the safety function, insert safety jumper connector, an accessory of the servo drive, into the STO. If you do not install the connector, neither motor current will be supplied nor torque output from the motor. In this case, the panel monitor state at the power ON will be "Sto." (Note) When removing the safety jumper connector attached to the STO, pull out the motor main circuit connector first, and then the connector body while pressing the lock ejector on the jumper connector side towards the servo drive side. The connector may be damaged if you pull it out without the lock released. Please be careful. Lock ejector |
Refer to Section 2.5 Wiring for Input/Output Signals. |
4 | Connect ECAT IN and OUT of the EtherCAT communication connector between the upper level device and Servo Drive. (Note) Please use the CAT5 and SFTP cables. |
Refer to Section 2.5 Wiring for Input/Output Signals. |
Actual operation
Conform to the checklist and precautions before test drive. |
Check input/output signals and connection to the upper level controller. |
Carry out test drive of the servo drive using the TwinCAT System Manager. |
Carry out test drive of the servo drive using the XGT PLC + PN8B. |
Carry out test drive with the combination of machine and servo motor. |
12. Test Drive
12-4
5 | Turn on the servo drive. The servo drive communication is in the Safe OP state. Make sure that the state of the servo drive panel monitor is as the figure below: The Link/Activity LED is flickering. The RUN LED is in "Single Flash." (Note) If the Error LED is flickering or on, and the monitor panel state is AL-xx, refer to Manual Maintenance and Inspection. (Note) If the Link/Activity LED is not flickering, the communication is not established. |
Refer to Section 11 Maintenance and Inspection. |
6 | Now, we finished checking the connection and state of input signal circuits to prepare for test drive. |
Refer to Section 11 Maintenance and Inspection. |
12.2 Test Drive Using TwinCAT System Manager
Test Drive Procedure
Order | Handling | Notes |
1 | Before launching the TwinCAT System Manager, copy the servo drive XML file into the schema folder (C:TwinCATIoEtherCAT). |
|
2 | Launch the TwinCAT System Manager. | |
3 | Select the target system. When carrying out the test drive using a remote system, select its device. |
|
4 | Restart the TwinCAT System with the "Config Mode." Using the "Set/Reset TwinCAT to Config Mode" icon under the TwinCat System Manager, you can restart the system with the Config Mode. |
|
5 | Search for the EtherCAT communication based devices connected to the system. Right-click the I/O Devices in the Work Space pane of the TwinCAT system to select "Scan Devices." |
12. Test Drive
12-5
If the dialog window below pops up in the TwinCAT System Manager, select "OK". If the "new I/O devices found" dialog window pops up, select any device or servo drive required to be driven for test and select the "OK" button. If the dialog window below pops up, select the "Yes" button. |
|
6 | Add the NC Task of the servo drive to the NC-Configuration. If the dialog window below pops up, select "Yes." |
12. Test Drive
12-6
7 | Switch the TwinCAT System Manager to Free Run state, allowing it to control devices independently of the TwinCAT PLC and so on. If the dialog window below pops up, select "Yes." |
8 | Make sure that the NC Task is added to the NC-Configuration tree in the workspace on the left, and the servo drive is registered to the "I/O Configuration" tree. If the connected servo drive is registered, select it. Click the "Online" tab on the right side to verify that the "Current State" and the "Requested State" are in the "SAFEOP" state. |
9 | Switch the EtherCAT communication state from the SafeOP state to the OP state, enabling the MailBox Communication and the Process Data Communication. Click the Generate Mappings icon on the menu bar. Map the images defined in the NC Task and the I/O Device. Click the Check Configuration icon on the menu bar. Check if the configuration currently set is valid. Click the Activate Configuration icon on the menu bar. Save the Project Configuration in the Windows Registry. |
10 | Verify if the EtherCAT communication state is switched from the SafeOP state to the OP state. Verify if the states of the servo drive panel monitor and the I/O device (servo drive) of the TwinCAT system are in online state as shown in the figure below. Check the panel monitor status. |
12. Test Drive
12-7
Check the communication LED. The Link/Activity LED is flickering. The RUN LED is on. Check the online state of the I/O device of the TwinCAT system. In the I/O-Configuration tree of the workspace, select the servo drive under the test drive, and then the "Online" tab, to check to see if the "Current State" and the "Requested State" are in the OP state. Verify if the state displayed on the bottom right of the TwinCAT System Manager menu window is in the Run state. |
|
11 | We finished adding the NC-Task and I/O Devices (servo drive) to the TwinCAT System Manager. |
Setting NC-Task Axis Parameters
Order | Handling | Notes |
1 | Set the unit of display of the relevant axis. Select the "Axis1." Select the "Settings" tab. Select the unit of display for position and speed. |
12. Test Drive
12-8
(Note) Note that the actual unit will not be converted even when the unit shown in the figure above was converted to mm or degree. (Note) Change the unit and tune the Axis Scaling Factor below. |
|
2 | Set the Axis Scaling Factor. The Axis Scaling Factor determines the distance of the axial load movement while the motor shaft makes one revolution. Select the "Axis1." Select the "Parameter" tab. Set "Scale Factor." Then, download the settings. (Note) The default is 0.0001 if the scaling factor is not set. (Note) After the setting, download the settings. |
3 | Set the speed parameter of the test drive axis. Select "Axis 1." Select the "Parameter" tab. Set the "Maximum Velocity", the "Manual Velocity (Fast)", and the "Manual Velocity (Slow)." Then, download the settings. |
4 | Set the speed, acceleration, and jerk of the test drive axis. Set the acceleration, deceleration, and jerk directly for the test drive axis; the TwinCAT NC can calculate the acceleration based on the configured profile timing. Select the Axis 1. Select the "Dynamics" tab. Set the acceleration, deceleration, and jerk directly. Select the "Direct" radio button. |
12. Test Drive
12-9
Set the acceleration, deceleration, and jerk. Download the settings. Set the acceleration, deceleration, and jerk indirectly. Set the acceleration, deceleration, and jerk indirectly by setting the acceleration time. If you change the acceleration time, the acceleration value will be automatically changed. Select the "Indirect by Acceleration Time" radio button. Set the acceleration, deceleration, and jerk. Download the settings. |
|
5 | Set the Position Lag Monitoring (Positional Error). Select "Axis 1." Select the "Parameter" tab. Set the Position Lag Monitoring. Set the Position Lag Filter Time. Download the settings. |
12. Test Drive
12-10
(Note) The Position Lag Monitoring is the difference between the position reference and the actual position at a given cycle time. When the Position Lag Monitoring is enabled, the TwinCAT NC generates an alarm if the positional error exceeds the settings. |
Test Drive of Servo Drive Using TwinCAT NC Axis
Order | Handling | Notes |
1 | Make sure that the TwinCAT NC axis is "Servo On." Select "Axis 1." Select the "Online" tab. Click the "Set" button. Select "Controller", "Feed Fw", and "Feed Bw." Set the Override to 100%. |
12. Test Drive
12-11
Click the "OK" button. Make sure that the state of the servo drive panel monitor is as the figure below: |
|
2 | Use the buttons shown below to manually perform the drive test (JOG). |
Make a reverse rotation at the specified Manual Velocity (Fast). |
|
Make a reverse rotation at the specified Manual Velocity (Slow). |
|
Make a forward rotation at the specified Manual Velocity (Slow). |
|
Make a forward rotation at the specified Manual Velocity (Fast). |
|
3 | Carry out the test drive with a relative coordinate. Set the "Target Position." Set the “Target Velocity.” Click “F5.” Move it to the Target Position from the current position, decelerating to stop. After moving it to the Target Position, verify if the Set Position is identical to the Target Position. Click "F6" to stop during the relative coordinate driving. When the alarm goes off, click "F8" to reset the alarm. (Note) If the position limit is enabled, set the Target Position within the limit. |
4 | Make sure that the TwinCAT NC axis is "Servo Off." Click "Set." Deselect "Controller", "Feed Fw", and "Feed Bw." Click "OK". |
12. Test Drive
12-12
5 | The test drive of servo drive using the TwinCAT NC axis is completed. |
12.3 Test Drive Using LSIS PLC (XGT + PN8B)
Test Drive Procedure
Order | Handling | Notes |
1 | Launch the XG-PM. | |
2 | Create a new project. On the menu bar, click Project New Project. |
|
3 | Name the new project. Select the PLC series and the CPU type. Select the module type (XGF-PN8B), and click OK. |
12. Test Drive
12-13
4 | The PC and the PLC are connected for communication. On the menu bar, click Online Connection. When the PC and the PLC are connected, the connection between the PLC and the servo drive will be enabled as shown in the figure below: |
5 | Connect PLC with Servo Drive. For the first connection, enable the network parameters and the servo |
12. Test Drive
12-14
parameters in the workspace on the left through "Connect Network Servo Automatically." After the servo drive and the PLC are connected, the servo parameters and the motor test drive function will be enabled. Connecting multiple shafts enables the servo parameters as many as the number of the connected shafts. Make sure that the state of the servo drive panel monitor is as the figure below: Check the state of the status LEDs. The Link/Activity LED is flickering. The RUN LED is on. (Note) The automatic connection of network servo registers the device connected to the XGT, and initializes the parameters of the connected device. (Note) For subsequent connections, connect or disconnect the XGT and the servo drive by connecting the entire servos or disconnecting them respectively, since the device has been registered and its parameters initialized through automatic servo connection. (Note) In case that there is any change in the connected device of the XGT, initialize the parameters of the device connected by the automatic servo connection. |
12. Test Drive
12-15
6 | Set the Driving Parameters of Test Drive Axis Basic Parameters. Enter the number of encoder pulses per motor revolution. Encoder resolution of 19 bits = 524288 Check the motor specifications, and then configure appropriate settings. Set the unit of the speed command. It can be set as rpm or mm/s. Set the speed limit. Check the motor specifications, and then configure appropriate settings. |
7 | Set the Driving Parameters of Test Drive Axis Manual Operation (Jog) Parameters. |
8 | Set the servo parameters of the test drive axis. |
12. Test Drive
12-16
Select parameters that you want to change, and then change them. To change any parameter during operation, check the "Allow to Modify Servo Parameters During Operation" checkbox at the top center. You can display a parameter value as a decimal or hexadecimal. |
|
9 | Save the configured parameters. On the menu bar, click Online Write. With the Write Project dialog window enabled, check the Operation Data of Test Drive Axis, the Operation Parameters, and the Servo Parameters checkboxes, and then click OK to save the configured parameters. |
10 | Turn on the servo. On the menu bar, click the Servo ON icon to turn on the servo of the servo drive of the test drive axis. |
12. Test Drive
12-17
11 | Save the configured parameters. Select the "System View" and the "Basic Command" tabs in the workspace to check the state of the servo drive as shown in the figure below: Make sure that the state of the servo drive panel monitor is as the figure below: Check the state of the status LEDs. The Link/Activity LED is flickering. The RUN LED is on. |
12 | Test drive using jog operation and inching operation |
12. Test Drive
12-18
For the "Jog Operation," the motor is driven with the settings of the operation parameters. For the "Inching Operation," the motor moves to the entered position. After entering the position value, click the "Run" button to carry out the test drive. |
|
13 | Point to Point Test Drive Select Workspace Command Tool Point Command tab. Set the operation data. On the "Point Command" tab in the workspace, specify the number and the rank of point operations. On the menu bar, click Online Write to store the operation data. On the Point Command tab, click the "Run" button to carry out the test drive. |
14 | The test drive of serve drive using the XGT is completed. |
13. Appendix
13-19
13. Appendix
13.1 Firmware Update
13.1.1 Use of USB OTG
The drive performs USB host function to search for firmware files in the USB memory and download
them to flash memory inside the drive. You can easily update the firmware using the USB memory and
OTG cable without a PC. The update procedure is as follows:
(1) Prepare a download cable (USB OTG cable) and a USB memory.
Use a USB OTG cable, consisting of USB Female Plug Type A and USB Mini B 5 pins, as the
download cable.
+
(2) Copy the firmware file (L7NH_FW.bin) to update to the USB memory.
*Caution
1. The L7NH_FW.bin file should be placed in the root directory of the USB memory, and the full
file name including the extension should match.
2. The formatting type of the USB memory has to be set to FAT32 (default).
(3) After connecting the USB memory to the USB OTG cable, connect it to the USB terminal and
power on the drive.
(4) When 7-Segment for servo status display shows ‘boot’ and then ‘otg’, it indicates that update is in
progress. Three horizontal bars of FND Digit5 are sequentially turned on from bottom to top, it
indicates that download is complete. At the time, remove the USB OTG cable and USB memory.
(7-segments display a message when downloading the firmware using the OTG)
13. Appendix
13-20
(5) Turn on the power again, and verify if the firmware is updated.
13. Appendix
13-21
13.1.2 Use of FoE (File access over EtherCAT)
FoE is a simple file transfer protocol using the EtherCAT, enabling firmware update. When the drive
and the upper level controller (e.g.: TwinCAT) are connected, you can simply update the firmware
remotely via FoE. The update procedure is as follows:
(1) Establish communication between the drive and the TwinCAT.
(2) I/O Configuration of TwinCAT - On the Online tab of the drive connected to the I/O, click Bootstrap
in the State Machine menu.
13. Appendix
13-22
(3) After the current state is changed to BOOT and you check the drive status (7-segments display
boot), wait for approx. 10 seconds until the internal flash memory of the drive is cleared.
(7-segments display a message when downloading the firmware using the FoE)
13. Appendix
13-23
(7-segments display a message when Flash deletion is complete while downloading the firmware using
the FoE)
*Caution
The following error occurs if you try to download before the required 10 seconds pass for the
flash memory to be cleared. Two error windows shown below may indicate that the flash
memory is not deleted completely, or the file name does not match. Check the file name, wait
for 10 seconds until the flash memory is cleared, and then try it again.
(4) Click Download in the File Access over EtherCAT menu at the bottom of the Online tab.
(5) Select the path of the file to be downloaded (L7NH_FW.efw or L7NH_FW.bin) and the file. If the
file name does not match, download will not start and the following error will occur:
(6) Enter the password for file download and click OK to start the download. (Password: 00000000)
(7) If "Downloading..." is displayed as shown in the following figure, the download is in progress. If the
progress bar at the bottom is full, it indicates the download is completed. After completing the
download, be sure to click Init in the State Machine menu to switch it to the Init status.
13. Appendix
13-24
(7-segments display a message when you finished downloading the firmware using the FoE)
*Caution
If you do not change the communication state to Init and turn on the power again according
to the upper level controller, the state will be automatically changed to BOOT and the flash
memory may be cleared. In this case, you have to download the firmware again according
to this procedure.
(8) After the download is completed, turn on the power again and verify if the firmware is updated.
13. Appendix
13-25
13.1.3 Use of Drive CM
Drive CM allows the firmware upgrade through the PC's USB port. The transmission time
depends on the PC performance, but it usually takes from scores of seconds to several
minutes.
Select Setup Firmware Update from the top main menu or click on the corresponding
shortcut icon.
Precautions for Firmware Upgrade
Do not turn off the PC or drive during transmission.
Do not unplug the USB cable or close the firmware program during transmission.
Do not run other applications on the PC during transmission.
Before upgrade drive’s parameter(object), Please same predetermined value since the
value can be re-set.
Operation of OS Download
1) Click the “Open Firmware Downloader” button
13. Appendix
13-26
2) To load the appropriate firmware file, click the "Load" button..
3) Select the BIN file of the firmware to transmit and press the Open button.
13. Appendix
13-27
4) “Total Length" and "Total Packet" of the loaded firmware are displayed.
5) Press the "Start" button to start transmission. 10 seconds are counted down to clear the
internal memory in the drive. (For L7NH and L7P, the segment 7 should display "USB". For
PEGASUS, a red "ERR" LED should be illuminated.)
6) After clearing, the firmware is transmitted automatically and the progress bar and "Current
Packet" display the current transmission status. (The transmission time depends on the PC
performance, but it usually takes from scores of seconds to several minutes.)
13. Appendix
13-28
7) When transmission is completed, a popup saying "Transmission completed" is displayed.
(When transmission to the PC is completed, turn off and on the drive for rebooting.)
An Error Occurs During Transmission
■ Turn off and on the drive and repeat the above process from (2) to (7)
■ Check firmware drive type and capacity to transmit.
13. Appendix
13-29
■ Check firmware version. The firmware version is lower than current one can’t be
downloaded
User Manual Revision History
Number | Date issued | Revised content | Version number |
Notes |
1 | 2014.09.24 | Added functions and precautions | 1.1 | |
2 | 2014.11.06 | Added New Model(XDL-L7NHB050U) | 1.2 | |
3 | 2015.05.15 | Added functions and modified typing error | 1.4 | |
4 | ||||
5 | ||||
6 | ||||
7 | ||||
8 | ||||
9 |
Green Management
LS Mecapion considers protecting the
environment a high priority. We work hard to
protect the Earth.
Product Disposal
The LS Mecapion servo drive is
environmentally friendly.
You can disassemble the drive and recycle the
iron, aluminum, bronze, and synthetic resin
(cover) components.
http://www.lsis.com
LSIS values every single customers.
Quality and service come first at LSIS.
Always at your service, standing for our customers.
■ HEAD OFFICE
LS Tower, 127, LS-ro, Dongan-gu, Anyang-si,Gyeonggi-do, 431-848
Korea http://eng.lsis.com
Tel : (82-2)2034-4870/Fax : 82-2-2034-4648 e-mail : cshwang@lsis.com
■ LSIS Tokyo Office _ Tokyo, Japan
Address: 16FL. Higashi-Kan. Akasaka Twin Tower 17-22,
Akasaka.Monato-ku Tokyo 107-8470. Japan
Tel : 81-3-3582-9128/Fax : 81-3-3582-2667 e-mail : jschuna@lsis.com
■ LSIS (ME) FZE _ Dubai, U.A.E.
Address : Jafza View Tower Lob 19, Room 205 Along Sheikh Zayed
Road Jebel Aali Free Zone Dubai, United Arab Emirates
Tel : 971-4-886-5360/Fax : 971-4-886-5361 e-mail : jungyongl@lsis.com
■ LSIS Shanghai Office _ Shanghai, China
Address : Room E-G. 12FL Hiamin Empire Plaza. No.726. West.
Yan'an Road Shanghai 200050. P.R. China e-mail : liyong@lsis.com.cn
Tel : 86-21-5237-9977(609)/Fax : 89-21-5237-7189
■ LSIS Beijing Office _ Beijing, China
Address : B-Tower 17FL. Beijing Global Trade Center B/D. No. 36.
East BeisanHuan-Road. DongCheng-District. Beijing 100013. P.R. China
Tel : 86-10-5825-6027(666)/Fax : 86-10-5825-6028 e-mail : xunmj@lsis.com.cn
■ LSIS Guangzhou Office _ Guangzhou, China
Address : Room 1403.14FL. New Poly Tower.
2 Zhongshan Liu Road.Guangzhou.P.R China
Tel : 86-20-8328-6754/Fax : 86-20-8326-6287 e-mail : chenxs@lsis.com.cn
■ LSIS Chengdu Office _ Chengdu, China
Address : 12FL. Guodong Buiding. No.52 Jindun
Road Chengdu.610041. P.R. China
Tel : 86-28-8612-9151(9226)/Fax : 86-28-8612-9236 e-mail : comysb@lsis.com
■ LSIS Qingdao Office _ Qingdao, China
Address : YinHe Bldg. 402 Room No. 2P Shandong Road,
Qingdao-City,Shandong-province 266071, P.R. China
Tel : 86-532-8501-6068/Fax : 86-532-8501-6057 e-mail : wangzy@lsis.com.cn
■ LSIS Europe B.V. , Netherlands
Address : 1st. Floor, Tupolevlaan 48, 1119NZ, Schiphol-Rijk, The Netherlands
Tel : +31 (0)20 654 1420/Fax : +31 (0)20 654 1429 e-mail : junshickp@lsis.com
■ Wuxi LSIS Co., Ltd _ Wuxi, China
Address : 102-A. National High & New Tech Industrial Development Area.
Wuxi. Jiangsu. 214028. P.R. China
Tel : 86-510-8534-6666/Fax : 86-510-8534-4078 e-mail : caidx@lsis.com.cn
■ Dalian LSIS Co., Ltd. _ Dalian, China
Address : No. 15. Liaohexi 3-Road. Economic and Technical Development zone.
Dalian 116600. China
Tel : 86-411-273-7777/Fax : 86-411-8730-7560 e-mail : cuibx@lsis.com.cn
※ LSIS constantly endeavors to improve its product so that
information in this manual is subject to change without notice.
ⓒ LSIS Co., Ltd 2014 All Rights Reserved.
2015. 6